68 resultados para Program Optimization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objective: Therapeutic Drug Monitoring (TDM) has been introduced early 1970 in our hospital (CHUV). It represents nowadays an important routine activity of the Division of Clinical Pharmacology and Toxicology (PCL), and its impact and utility for clinicians required assessment. This study thus evaluated the impact of TDM recommendations in terms of dosage regimen adaptation. Design: A prospective observational study was conducted over 5 weeks. The primary objective was to evaluate the application of our TDM recommendations and to identify potential factors associated to variations in their implementation. The secondary objective was to identify pre-analytical problems linked to the collection and processing of blood samples. Setting: Four representative clinical units at CHUV. Main outcome measure: Clinical data, drug related data (intake, collection and processing) and all information regarding the implementation of clinical recommendations were collected and analyzed by descriptive statistics. Results: A total of 241 blood measurement requests were collected, among which 105 triggered a recommendation. 37% of the recommendations delivered were applied, 25 % partially applied and 34% not applied. In 4% it was not applicable. The factors determinant for implementation were the clinical unit and the mode of transmission of the recommendation (written vs oral). No clear difference between types of drugs could be detected. Pre-analytical problems were not uncommon, mostly related to completion of request forms and delays in blood sampling (equilibration or steady-state not reached). We have identified 6% of inappropriate and unusable drug level measurements that could cause a substantial cost for the hospital. Conclusion: This survey highlighted a better implementation of TDM recommendations in clinical units where this routine is well integrated and understood by the medical staff. Our results emphasize the importance of communication with the nurse or the physician in charge, either to transmit clinical recommendations or to establish consensual therapeutic targets in specific conditions. Development of strong partnerships between clinical pharmacists or pharmacologists and clinical units would be beneficial to improve the impact of this clinical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND/AIMS: One of the causes of uncontrolled secondary hyperparathyroidism (sHPT) is patient's poor drug adherence. We evaluated the clinical benefits of an integrated care approach on the control of sHPT by cinacalcet. METHODS: Prospective, randomized, controlled, multicenter, open-label study. Fifty hemodialysis patients on a stable dose of cinacalcet were randomized to an integrated care approach (IC) or usual care approach (UC). In the IC group, cinacalcet adherence was monitored using an electronic system. Results were discussed with the patients in motivational interviews, and drug prescription adapted accordingly. In the UC group, drug adherence was monitored, but results were not available. RESULTS: At six months, 84% of patients in the IC group achieved recommended iPTH targets versus 55% in the UC group (P = 0.04). The mean cinacalcet taking adherence improved by 10.8% in the IC group and declined by 5.3% in the UC group (P = 0.02). Concomitantly, the mean dose of cinacalcet was reduced by 7.2 mg/day in the IC group and increased by 6.4 mg/day in the UC group (P = 0.03). CONCLUSIONS: The use of a drug adherence monitoring program in the management of sHPT in hemodialysis patients receiving cinacalcet improves drug adherence and iPTH control and allows a reduction in the dose of cinacalcet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the Juste-Neige system for predicting the snow height on the ski runs of a resort using a multi-agent simulation software. Its aim is to facilitate snow cover management in order to i) reduce the production cost of artificial snow and to improve the profit margin for the companies managing the ski resorts; and ii) to reduce the water and energy consumption, and thus to reduce the environmental impact, by producing only the snow needed for a good skiing experience. The software provides maps with the predicted snow heights for up to 13 days. On these maps, the areas most exposed to snow erosion are highlighted. The software proceeds in three steps: i) interpolation of snow height measurements with a neural network; ii) local meteorological forecasts for every ski resort; iii) simulation of the impact caused by skiers using a multi-agent system. The software has been evaluated in the Swiss ski resort of Verbier and provides useful predictions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Failure to detect a species in an area where it is present is a major source of error in biological surveys. We assessed whether it is possible to optimize single-visit biological monitoring surveys of highly dynamic freshwater ecosystems by framing them a priori within a particular period of time. Alternatively, we also searched for the optimal number of visits and when they should be conducted. We developed single-species occupancy models to estimate the monthly probability of detection of pond-breeding amphibians during a four-year monitoring program. Our results revealed that detection probability was species-specific and changed among sampling visits within a breeding season and also among breeding seasons. Thereby, the optimization of biological surveys with minimal survey effort (a single visit) is not feasible as it proves impossible to select a priori an adequate sampling period that remains robust across years. Alternatively, a two-survey combination at the beginning of the sampling season yielded optimal results and constituted an acceptable compromise between sampling efficacy and survey effort. Our study provides evidence of the variability and uncertainty that likely affects the efficacy of monitoring surveys, highlighting the need of repeated sampling in both ecological studies and conservation management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To determine optimum spatial resolution when imaging peripheral arteries with magnetic resonance angiography (MRA). MATERIALS AND METHODS: Eight vessel diameters ranging from 1.0 to 8.0 mm were simulated in a vascular phantom. A total of 40 three-dimensional flash MRA sequences were acquired with incremental variations of fields of view, matrix size, and slice thickness. The accurately known eight diameters were combined pairwise to generate 22 "exact" degrees of stenosis ranging from 42% to 87%. Then, the diameters were measured in the MRA images by three independent observers and with quantitative angiography (QA) software and used to compute the degrees of stenosis corresponding to the 22 "exact" ones. The accuracy and reproducibility of vessel diameter measurements and stenosis calculations were assessed for vessel size ranging from 6 to 8 mm (iliac artery), 4 to 5 mm (femoro-popliteal arteries), and 1 to 3 mm (infrapopliteal arteries). Maximum pixel dimension and slice thickness to obtain a mean error in stenosis evaluation of less than 10% were determined by linear regression analysis. RESULTS: Mean errors on stenosis quantification were 8.8% +/- 6.3% for 6- to 8-mm vessels, 15.5% +/- 8.2% for 4- to 5-mm vessels, and 18.9% +/- 7.5% for 1- to 3-mm vessels. Mean errors on stenosis calculation were 12.3% +/- 8.2% for observers and 11.4% +/- 15.1% for QA software (P = .0342). To evaluate stenosis with a mean error of less than 10%, maximum pixel surface, the pixel size in the phase direction, and the slice thickness should be less than 1.56 mm2, 1.34 mm, 1.70 mm, respectively (voxel size 2.65 mm3) for 6- to 8-mm vessels; 1.31 mm2, 1.10 mm, 1.34 mm (voxel size 1.76 mm3), for 4- to 5-mm vessels; and 1.17 mm2, 0.90 mm, 0.9 mm (voxel size 1.05 mm3) for 1- to 3-mm vessels. CONCLUSION: Higher spatial resolution than currently used should be selected for imaging peripheral vessels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hidden Markov models (HMMs) are probabilistic models that are well adapted to many tasks in bioinformatics, for example, for predicting the occurrence of specific motifs in biological sequences. MAMOT is a command-line program for Unix-like operating systems, including MacOS X, that we developed to allow scientists to apply HMMs more easily in their research. One can define the architecture and initial parameters of the model in a text file and then use MAMOT for parameter optimization on example data, decoding (like predicting motif occurrence in sequences) and the production of stochastic sequences generated according to the probabilistic model. Two examples for which models are provided are coiled-coil domains in protein sequences and protein binding sites in DNA. A wealth of useful features include the use of pseudocounts, state tying and fixing of selected parameters in learning, and the inclusion of prior probabilities in decoding. AVAILABILITY: MAMOT is implemented in C++, and is distributed under the GNU General Public Licence (GPL). The software, documentation, and example model files can be found at http://bcf.isb-sib.ch/mamot

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Integrating and expressing stably a transgene into the cellular genome remain major challenges for gene-based therapies and for bioproduction purposes. While transposon vectors mediate efficient transgene integration, expression may be limited by epigenetic silencing, and persistent transposase expression may mediate multiple transposition cycles. Here, we evaluated the delivery of the piggyBac transposase messenger RNA combined with genetically insulated transposons to isolate the transgene from neighboring regulatory elements and stabilize expression. A comparison of piggyBac transposase expression from messenger RNA and DNA vectors was carried out in terms of expression levels, transposition efficiency, transgene expression and genotoxic effects, in order to calibrate and secure the transposition-based delivery system. Messenger RNA reduced the persistence of the transposase to a narrow window, thus decreasing side effects such as superfluous genomic DNA cleavage. Both the CTF/NF1 and the D4Z4 insulators were found to mediate more efficient expression from a few transposition events. We conclude that the use of engineered piggyBac transposase mRNA and insulated transposons offer promising ways of improving the quality of the integration process and sustaining the expression of transposon vectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reducing comparative optimism regarding risk perceptions in traffic accidents has been proven to be particularly difficult (Delhomme, 2000). This is unfortunate because comparative optimism is assumed to impede preventive action. The present study tested whether a road safety training course could reduce drivers' comparative optimism in high control situations. Results show that the training course efficiently reduced comparative optimism in high control, but not in low control situations. Mechanisms underlying this finding and implications for the design of road safety training courses are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within the ORAMED project a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe. The main objectives of ORAMED were to obtain a set of standardized data on doses for staff in interventional cardiology and radiology and to optimize staff protection. Doses were measured with thermoluminescent dosemeters on the ring finger and wrist of both hands, on legs and at the level of the eyes of the main operator performing interventional procedures. In this paper an overview of the doses per procedure measured during 646 interventional cardiology procedures is given for cardiac angiographies and angioplasties (CA/PTCA), radiofrequency ablations (RFA) and pacemaker and defibrillator implantations (PM/ICD). 31% of the monitored procedures were associated with no collective protective equipment, whereas 44% involved a ceiling screen and a table curtain. Although associated with the smallest air kerma - area product (KAP), PM/ICD procedures led to the highest doses. As expected, KAP and doses values exhibited a very large variability. The left side of the operator, most frequently the closest to the X-ray scattering region, was more exposed than his right side. An analysis of the effect of parameters influencing the doses, namely collective protective equipment, X-ray tube configuration and catheter access route, was performed on the doses normalized to KAP. Ceiling screen and table curtain were observed to reduce normalized doses by atmost a factor 4, much smaller than theoretical attenuation factors typical for such protections, i.e. from 10 to 100. This observation was understood as their inappropriate use by the operators and their non-optimized design. Configurations with tube above the patient led to higher normalized doses to the operator than tube below, but the effect of using a biplane X-ray suite was more complex to analyze. For CA/PTCA procedures, the upper part of the operator's body received higher normalized doses for radial than for femoral catheter access, by atmost a factor 5. This could be seen for cases with no collective protection. The eyes were observed to receive the maximum fraction of the annual dose limit almost as frequently as legs and hands, and clearly the most frequently, if the former 150 mSv and new 20 mSv recommended limits for the lens of the eye are considered, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tractography is a class of algorithms aiming at in vivo mapping the major neuronal pathways in the white matter from diffusion magnetic resonance imaging (MRI) data. These techniques offer a powerful tool to noninvasively investigate at the macroscopic scale the architecture of the neuronal connections of the brain. However, unfortunately, the reconstructions recovered with existing tractography algorithms are not really quantitative even though diffusion MRI is a quantitative modality by nature. As a matter of fact, several techniques have been proposed in recent years to estimate, at the voxel level, intrinsic microstructural features of the tissue, such as axonal density and diameter, by using multicompartment models. In this paper, we present a novel framework to reestablish the link between tractography and tissue microstructure. Starting from an input set of candidate fiber-tracts, which are estimated from the data using standard fiber-tracking techniques, we model the diffusion MRI signal in each voxel of the image as a linear combination of the restricted and hindered contributions generated in every location of the brain by these candidate tracts. Then, we seek for the global weight of each of them, i.e., the effective contribution or volume, such that they globally fit the measured signal at best. We demonstrate that these weights can be easily recovered by solving a global convex optimization problem and using efficient algorithms. The effectiveness of our approach has been evaluated both on a realistic phantom with known ground-truth and in vivo brain data. Results clearly demonstrate the benefits of the proposed formulation, opening new perspectives for a more quantitative and biologically plausible assessment of the structural connectivity of the brain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Undernutrition is a widespread problem in intensive care unit and is associated with a worse clinical outcome. A state of negative energy balance increases stress catabolism and is associated with increased morbidity and mortality in ICU patients. Undernutrition-related increased morbidity is correlated with an increase in the length of hospital stay and health care costs. Enteral nutrition is the recommended feeding route in critically ill patients, but it is often insufficient to cover the nutritional needs. The initiation of supplemental parenteral nutrition, when enteral nutrition is insufficient, could optimize the nutritional therapy by preventing the onset of early energy deficiency, and thus, could allow to reduce morbidity, length of stay and costs, shorten recovery period and, finally, improve quality of life. (C) 2009 Elsevier Masson SAS. All rights reserved.