51 resultados para Percentagem de 18F


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our aim was to evaluate the role of forced diuresis in improving the diagnostic accuracy of abdominopelvic (18)F-FDG PET. METHODS: Thirty-two patients were enrolled. Besides the presence of known intravesical tumors or undefined renal lesions on the initial PET scan, the inclusion criterion was the appearance of indeterminate or equivocal (18)F-FDG foci that extended along the course of the urinary tract and could not confidently be separated from urinary activity. For each patient, a second abdominopelvic PET study was performed after intravenous injection of 0.5 mg of furosemide per kilogram of body weight (maximum, 40 mg) coupled with parenteral infusion of physiologic saline. RESULTS: Forced diuresis coupled with parenteral hydration eliminated any significant (18)F-FDG activity from the lower urinary tract in 31 (97%) of 32 patients after the bladder had been voided 3 successive times. Twelve intravesical lesions were visualized with outstanding clarity, whereas radiologic suspicion of locally recurrent bladder tumors was ruled out in 3 patients. Among 14 indeterminate or equivocal extravesical foci, 7 were deemed of no clinical value because they disappeared after furosemide challenge, whereas 7 persisting foci were proven to be true-positive PET findings. The performance of (18)F-FDG PET in characterizing 3 renal-space-occupying lesions could not be improved by our protocol. CONCLUSION: Furosemide challenge has the potential to noninvasively resolve the inherent (18)F-FDG contrast handicap in the lower urinary tract.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: 5-fluoro-2'-deoxyuridine (FdUrd) depletes the endogenous 5'-deoxythymidine triphosphate (dTTP) pool. We hypothesized whether uptake of exogenous dThd analogues could be favoured through a feedback enhanced salvage pathway and studied the FdUrd effect on cellular uptake of 3'-deoxy-3'-18F-fluorothymidine (18F-FLT) and 5-125I-iodo-2'-deoxyuridine (125I-IdUrd) in different cancer cell lines in parallel. Methods: Cell uptake of 18F-FLT and 125I-IdUrd was studied in 2 human breast, 2 colon cancer and 2 glioblastoma lines. Cells were incubated with/without 1 µmol/l FdUrd for 1 h and, after washing, with 1.2 MBq 18F-FLT or 125I-IdUrd for 0.3 to 2 h. Cell bound 18F-FLT and 125I-IdUrd was counted and expressed in % incubated activity (%IA). Kinetics of 18F-FLT cell uptake and release were studied with/without FdUrd modulation. 2'-3H-methyl-fluorothymidine (2'-3H-FLT) uptake with/without FdUrd pretreatment was tested on U87 spheroids and monolayer cells. Results: Basal uptake at 2 h of 18F-FLT and 125I-IdUrd was in the range of 0.8-1.0 and 0.4-0.6 Bq/cell, respectively. FdUrd pretreatment enhanced 18F-FLT and 125I-IdUrd uptake 1.2-2.1 and 1.7-4.4 fold, respectively, while co-incubation with excess thymidine abrogated all 18F-FLT uptake. FdUrd enhanced 18F-FLT cellular inflow in 2 breast cancer lines by factors of 1.8 and 1.6, respectively, while outflow persisted at a slightly lower rate. 2'-3H-FLT basal uptake was very low while uptake increase after FdUrd was similar in U87 monolayer cells and spheroids. Conclusions: Basal uptake of 18F-FLT was frequently higher than that of 125I-IdUrd but FdUrd induced uptake enhancement was stronger for 125I-IdUrd in five of six cell lines. 18F-FLT outflow from cells might be an explanation for the observed difference with 125I-IdUrd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Toperform a meta-analysis of FDG-PET performances in the diagnosis of largevessels vasculitis (Giant Cell Arteritis (GCA) associated or not withPolymyalgia Rheumatica(PMR), Takayasu). Materials and methods : The MEDLINE,Cochrane Library, Embase were searched for relevant original articlesdescribing FDG-PET for vasculitis assessment, using MesH terms ("GiantCell Arteritis or Vasculitis" AND "PET"). Criteria for inclusionwere:(1)FDG-PET for diagnosis of vasculitis(2)American College of Rheumatologycriteria as reference standard(3)control group. After data extraction, analyseswere performed using a random-effects model. Results : Of 184 citations(database search and references screening),70 articles were reviewed of which12 eligible studies were extracted (sensitivity range from 32% to 97%). 7studies fulfilled all inclusion criteria. Owing to overlapping population, 1study was excluded. Statistical heterogeneity justified the random-effectsmodel. Pooled 6 studies analysis(116 vasculitis,224 controls) showed a 81%sensitivity (95%CI:70-89%);a 89% specificity (95%CI:77-95%);a 85%PPV(95%CI:63-95%); a 90% NPV(95%CI:79-95%);a 7.1 positive LR(95%CI:3.4-14.9); a0.2 negative LR(95%CI:0.14-0.35) and 90.1 DOR(95%CI: 18.6-437). Conclusion :FDG-PET has good diagnostic performances in the detection of large vesselsvasculitis. Its promising role could be extended to follow up patients undertreatment, but further studies are needed to confirm this possibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The activity of radiopharmaceuticals in nuclear medicine is measured before patient injection with radionuclide calibrators. In Switzerland, the general requirements for quality controls are defined in a federal ordinance and a directive of the Federal Office of Metrology (METAS) which require each instrument to be verified. A set of three gamma sources (Co-57, Cs-137 and Co-60) is used to verify the response of radionuclide calibrators in the gamma energy range of their use. A beta source, a mixture of (90)Sr and (90)Y in secular equilibrium, is used as well. Manufacturers are responsible for the calibration factors. The main goal of the study was to monitor the validity of the calibration factors by using two sources: a (90)Sr/(90)Y source and a (18)F source. The three types of commercial radionuclide calibrators tested do not have a calibration factor for the mixture but only for (90)Y. Activity measurements of a (90)Sr/(90)Y source with the (90)Y calibration factor are performed in order to correct for the extra-contribution of (90)Sr. The value of the correction factor was found to be 1.113 whereas Monte Carlo simulations of the radionuclide calibrators estimate the correction factor to be 1.117. Measurements with (18)F sources in a specific geometry are also performed. Since this radionuclide is widely used in Swiss hospitals equipped with PET and PET-CT, the metrology of the (18)F is very important. The (18)F response normalized to the (137)Cs response shows that the difference with a reference value does not exceed 3% for the three types of radionuclide calibrators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contexte : La stimulation du nerf vague est une technique neurochirurgicale qui consiste en l'implantation d'une électrode envoyant des impulsions autours de celui-ci. Depuis l'approbation de la FDA en 1997 aux Etats-Unis, elle est utilisée chez certains patients épileptiques pharmaco-résistants et dont la chirurgie classique n'est pas envisageable [1], Par exemple lorsque qu'aucun foyer épileptique n'est identifiable, qu'une zone éloquente du cortex est atteinte ou encore qu'il y a de multiples points de départ. On parle généralement de patient « répondeur » lorsqu'une diminution de plus de 50% des crises est observée après l'opération. La proportion de patients répondeurs est estimée entre 20 à 50% [2], avec une action positive sur l'éveil [3]. Le mécanisme d'action de cette thérapie reste largement inconnu même si quelques ébauches d'hypothèses ont été formulées, notamment une action inhibitrice sur le noyau solitaire du nerf vague qui pourrait avoir comme effet de moduler des projections ascendantes diffuses via le locus coeruleus [3, 4]. Objectifs : Le but de ce travail est d'observer les effets de la stimulation du nerf vague sur le métabolisme cérébral et potentiellement d'élaborer des hypothèses sur le mécanisme d'action de ce traitement. Il faudra plus précisément s'intéresser au tronc cérébral, contenant le locus coeruleus (métabolisme de la noradrénaline) et aux noyaux du raphé (métabolisme de la sérotonine), deux neurotransmetteurs avec effet antiépileptique [5]. Le but sera également d'établir des facteurs prédictifs sur la façon de répondre d'un patient à partir d'une imagerie cérébrale fonctionnelle avant implantation, notamment au niveau du métabolisme cortical, particulièrement frontal (éveil) sera intéressant à étudier. Méthodes : Un formulaire d'information ainsi que de consentement éclairé sera remis à chaque patient avant inclusion dans l'étude. Les informations de chaque patient seront également inscrites dans un cahier d'observation (Case Report Form, CRF). Le travail s'organisera essentiellement sur deux populations. Premièrement, chez les patients déjà opérés avec un stimulateur en marche, nous réaliserons qu'une imagerie PET au F-18-fluorodeoxyglucose (FDG) post-opératoire qui seront comparés à une base de données de patients normaux (collaboration Dr E. Guedj, AP-HM, La Timone, Marseille). Nous confronterons également les images de ces patients entre elles, en opposant les répondeurs (diminution des crises de ≥50%) aux non-répondeurs. Deuxièmement, les patients non encore opérés auront un examen PET basal avant implantation et 3-6 mois après la mise en marche du stimulateur. Nous évaluerons alors les éventuelles modifications entre ces deux imageries PET, à la recherche de différences entre les répondeurs et non-répondeurs, ainsi que de facteurs prédictifs de bonne réponse dans l'imagerie de base. Toutes les comparaisons d'images seront effectuées grâce avec le programme d'analyse SPM08. Résultats escomptés : Nous espérons pouvoir mettre en évidence des modifications du métabolisme cérébral au FDG sur la base de ces différentes images. Ces constatations pourraient nous permettre de confirmer ou d'élargir les hypothèses physiologiques quant aux effets du traitement par stimulation vagale. Nous aimerions, de plus, amener à définir des facteurs prédictifs sur la façon de répondre d'un patient au traitement à l'aide du PET au F-18-FDG de départ avant implantation. Plus value escomptée : Ces résultats pourront donner des pistes supplémentaires quant au fonctionnement de la stimulation vagale chez les patients avec épilepsie réfractaire et servir de base à de nouvelles recherches dans ce domaine. Ils pourraient aussi donner des éléments pronostics avant l'implantation pour aider la sélection des patients pouvant bénéficier de ce type de thérapie.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Pleural effusion is common in cancer patients and to determine its malignant origin is of huge clinical significance. PET/CT with 18F-FDG is of diagnostic value in staging and follow-up, but its ability to differentiate between malignant and benign effusions is not precisely known. Patients, methods: We examined 50 PET/CT from 47 patients (29 men, 18 women, 60±16 years) with pleural effusion and known cancer (24 NSCLC, 7 lymphomas, 5 breasts, 4 GIST, 3 mesotheliomas, 2 head and neck, 2 malignant teratoma, 1 colorectal, 1 oesophageal, 1 melanoma) for FDG uptake in the effusions using SUVmax. This was correlated to cytopathology performed after a median of 21 days (interquartile range -3 to 23), which included pH, relative distribution (macrophages, neutrophils, eosinophils, basophils, lymphocytes, plasmocytes), and absolute cell count. Results: Malignant cells were found in 17 effusions (34%) (6 NSCLC, 5 lymphomas, 2 breasts, 2 mesotheliomas, 2 malignant teratomas). SUV in malignant effusions were higher than in benign ones [3.7 (95%CI 1.8-5.6) vs. 1.7 g/ml (1.5-1.9), p = 0.001], with a correlation between malignant effusion and SUV (Spearman coefficient r = 0.50, p = 0.001), but not with other cytopathological or radiological parameters (ROC area 0.83±0.06). Using a 2.2-mg/l SUV threshold, 12 PET/CT studies were positive and 38 negative with sensitivity, specificity, positive and negative predictive values of 53%, 91%, 75% and 79%, respectively. For NSCLC only (n = 24), ROC area was 0.95±0.04, 7 studies were positive and 17 negative with a sensitivity, specificity, positive and negative predictive values of 83%, 89%, 71 and 94%, respectively. Conclusion: PET/CT may help to differentiate the malignant or benign origin of a pleural effusion with a high specificity in patients with known cancer, in particular NSCLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare MDCT, MRI and 18F-FDG PET/CT for the detection of peritoneal carcinomatosis due to ovarian cancerMethods and Materials: Fifteen women (mean age 65±) with clinical suspicion of ovarian cancer and peritoneal carcinomatosis underwent MDCT, MRI and 18F-FDG PET/CT, simultaneously and shortly performed before surgery (delay 8.1± days). According to the peritoneal cancer index nine abdominopelvic regions were defined. We applied four scores of lesion size on MDCT and MR images, while the maximal standard uptake value (SUVmax) was measured on 18F-FDG PET/CT. Three sites of lymphadenopathy and posterobasal pleural carcinomatosis were also analyzed. First, one radiologist blindly and separately read MDCT and MR images, while one nuclear physician blindly read PET/CT images grading each lesion according to four diagnostic certitudes. Secondly, all the images were reviewed jointly and compared with histopathology. Receiver operating characteristics (ROC) analysis was performed.Results: Peritoneal implants were proven in ten women (75%). Altogether, 228 abdominopelvic sites were compared. Sensitivity and specificity for MDCT was 90.2% and 90.6%, for MRI 93.5% and 86.3%, and for 18F-FDG PET/CT 92.7% and 95.7%, respectively. ROC area under the curve were 0.93 for MDCT and MRI, and 0.96 for 18F-FDG PET/CT respectively. No significant differences (p=0.11) were found between the three modalities.Conclusion: Although MRI revealed to be the most sensitive and 18F-FDG PET/CT the most specific modality, no significant differences were shown between the three techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In oncology, positron emission computed tomography (PET/CT) has become an essential tool for initial staging, response evaluation and follow-up of cancer patients. Most of the frequent tumors (lung, breast, esophagus, and lymphomas) are highly avid for (18)F-fluorodeoxyglucose ((18)FDG), but prostate cancer has not demonstrated significant uptake of FDG. The development of new tracers labeled with (18)F such as choline analogs allowed already to obtain interesting results particularly in patients with biological relapse and inconclusive conventional imaging workup. The impact of (18)F-flurocholine PET/CT on patient management needs to be validated in large studies, but many centers use already this examination in order to guide further management, including radiotherapy planning. (C) 2011 Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Positron emission tomography with (18)F-fluorodeoxyglucose (FDG-PET) was used to evaluate treatment response in patients with gastrointestinal stromal tumors (GIST) after administration of sunitinib, a multitargeted tyrosine kinase inhibitor, after imatinib failure. PATIENTS AND METHODS: Tumor metabolism was assessed with FDG-PET before and after the first 4 weeks of sunitinib therapy in 23 patients who received one to 12 cycles of sunitinib therapy (4 weeks of 50 mg/d, 2 weeks off). Treatment response was expressed as the percent change in maximal standardized uptake values (SUV). The primary end point of time to tumor progression was compared with early PET results on the basis of traditional Response Evaluation Criteria in Solid Tumors (RECIST) criteria. RESULTS: Progression-free survival (PFS) was correlated with early FDG-PET metabolic response (P < .0001). Using -25% and +25% thresholds for SUV variations from baseline, early FDG-PET response was stratified in metabolic partial response, metabolically stable disease, or metabolically progressive disease; median PFS rates were 29, 16, and 4 weeks, respectively. Similarly, when a single FDG-PET positive/negative was considered after 4 weeks of sunitinib, the median PFS was 29 weeks for SUVs less than 8 g/mL versus 4 weeks for SUVs of 8 g/mL or greater (P < .0001). None of the patients with metabolically progressive disease subsequently responded according to RECIST criteria. Multivariate analysis showed shorter PFS in patients who had higher residual SUVs (P < .0001), primary resistance to imatinib (P = .024), or nongastric GIST (P = .002), regardless of the mutational status of the KIT and PDGFRA genes. CONCLUSION: Week 4 FDG-PET is useful for early assessment of treatment response and for the prediction of clinical outcome. Thus, it offers opportunities to individualize and optimize patient therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contexte Lié au vieillissement et à la sédentarisation de la population, ainsi qu'à la chronicisation du cancer, l'emploi de cathéters veineux centraux permanents (CVCP) n'a cessé d'augmenter. La complication majeure de ces dispositifs, induisant de forts taux de morbi-mortalité, est l'infection. Actuellement, le diagnostic de ces infections reste surtout basé sur la clinique et les hémocultures. Lorsque le doute persiste, une ablation chirurgicale suivie de la mise en culture des prélèvements chirurgicaux et du cathéter permettent de poser le diagnostic. En clinique, après ces examens, nous constatons que seule la moitié des cathéters retirés étaient réellement infectés. Alors que la tomographie par émission de positons fusionnée à la tomographie (PET/CT) a montré de bons résultats dans la détection des infections chroniques, la valeur diagnostique du PET/CT au fluorodeoxyglucose marqué au 18F (18F-FDG) pour les infections de CVCP n'a encore jamais été déterminée dans une étude prospective. Objectifs Au travers de cette étude prospective, ouverte et monocentrique, nous chercherons à connaître la valeur diagnostique du PET/CT au 18F-FDG dans la détection d'infections de CVCP et ainsi d'en déterminer son utilité. Nous essaierons aussi de déterminer la différence de valeur diagnostique du PET/CT au 18F-FDG par rapport aux méthodes conventionnelles (paramètres cliniques et culture du liquide d'aspiration), afin de se déterminer sur l'éventuelle utilité diagnostique de celui-ci. Méthodes Cadre : Etude prospective d'au moins 20 patients, avec 2 groupes contrôles d'au moins 10 patients ayant chacun respectivement une faible et une forte probabilité d'infection, soit au moins 40 patients au total. Population : patients adultes avec CVCP devant être retiré. Cette étude prévoit un examen PET/CT au 18F-FDG effectué auprès de patients nécessitant une ablation de CVCP sur suspicion d'infection, sans confirmation possible par les moyens diagnostiques non chirurgicaux. Deux acquisitions seront réalisées 45 et 70 minutes après l'injection de 5,5MBq/Kg de 18F-FDG. Le groupe contrôle à faible probabilité d'infection, sera formé de patients bénéficiant de l'ablation définitive d'un CVCP pour fin de traitement durant le laps de temps de l'étude, et ayant bénéficié au préalable d'un examen PET/CT pour raison X. Après avoir retiré chirurgicalement le CVCP, nous utiliserons la culture microbiologique des deux extrémités du CVCP comme étalon d'or (gold standard) de l'infection. Le groupe contrôle à forte probabilité d'infection sera formé de patients nécessitant une ablation de CVCP sur infection de CVCP confirmée par les moyens diagnostiques non chirurgicaux (culture positive du liquide de l'aspiration). Lors de l'examen PET/CT, ces patients auront aussi deux acquisitions réalisées 45 et 70 minutes après l'injection de 5,5MBq/Kg de 18F-FDG. Les résultats de ces examens seront évalués par deux spécialistes en médecine nucléaire qui détermineront le niveau de suspicion de l'infection sur une échelle de Likert allant de I à V, sur la base du nombre de foyers, de la localisation du foyer, de l'intensité de la captation de 18F-FDG au voisinage du cathéter et du rapport tissu/arrière-plan. Par la suite, nous retirerons chirurgicalement le CVCP. Nous utiliserons la culture microbiologique du pus (si présent), des deux extrémités du CVCP ainsi que l'histologie des tissus formant un tunnel autour du cathéter comme étalon d'or de l'infection. Les résultats seront analysés à l'aide de courbes ROC (Receiver Operating Characteristic) afin de déterminer la valeur diagnostique du PET/CT dans l'infection de CVCP. Les résultats des examens des patients avec suspicion clinique d'infection seront ensuite analysés séparément, afin de déterminer la différence de valeur diagnostique du PET/CT au 18F-FDG par rapport aux méthodes conventionnelles. Résultats escomptés Ce projet veut chercher à savoir si le PET/CT au 18F-FDG peut être un moyen diagnostique valide dans les infections de CVCP, s'avérer utile lorsque les autres moyens diagnostiques sont non conclusifs. Plus-value escomptée Actuellement, lors d'incertitude sur le diagnostic d'infection de CVCP, une opération chirurgicale est effectuée à titre préventif afin d'enlever le cathéter en cause, cependant seulement la moitié de ces cathéters sont réellement infectés en pratique. Le PET/CT au 18F-FDG, grâce à sa sensibilité élevée et probablement une bonne valeur prédictive négative, pourrait éviter à une partie des patients un retrait inutile du cathéter, diminuant ainsi les risques chirurgicaux et les coûts liés à de telles opérations, tout en préservant le capital d'accès vasculaire futur.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to compare multidetector CT (MDCT), MRI, and FDG PET/CT imaging for the detection of peritoneal carcinomatosis (PC) in ovarian cancer. PATIENTS AND METHODS: Fifteen women with ovarian cancer and suspected PC underwent MDCT, MRI, and FDG PET/CT, shortly before surgery. Nine abdominopelvic regions were defined according to the peritoneal cancer index. We applied lesion size scores on MDCT and MR and measured FDG PET/CT standard uptake. We blindly read MDCT, MR, and PET/CT before joint review and comparison with histopathology. Receiver operating characteristics analysis was performed. RESULTS: Ten women had PC (67%). Altogether, 135 abdominopelvic sites were compared. Multidetector CT, MRI, and FDG PET/CT had a sensitivity of 96%, 98%, and 95%, and specificity was 92%, 84%, and 96%, respectively. Corresponding receiver operating characteristics area was 0.94, 0.90, and 0.96, respectively, without any significant differences between them (P = 0.12). FDG PET/CT detected supradiaphragmatic disease in 3 women (20%) not seen by MDCT or MRI. CONCLUSIONS: Although MRI had the highest sensitivity and FDG PET/CT had the highest specificity, no significant differences were found between the 3 techniques. Thus, MDCT, as the fastest, most economical, and most widely available modality, is the examination of choice, if a stand-alone technique is required. If inconclusive, PET/CT or MRI may offer additional insights. Whole-body FDG PET/CT may be more accurate for supradiaphragmatic metastatic extension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: For the past decade (18)F-fluoro-ethyl-l-tyrosine (FET) and (18)F-fluoro-deoxy-glucose (FDG) positron emission tomography (PET) have been used for the assessment of patients with brain tumor. However, direct comparison studies reported only limited numbers of patients. Our purpose was to compare the diagnostic performance of FET and FDG-PET. METHODS: We examined studies published between January 1995 and January 2015 in the PubMed database. To be included the study should: (i) use FET and FDG-PET for the assessment of patients with isolated brain lesion and (ii) use histology as the gold standard. Analysis was performed on a per patient basis. Study quality was assessed with STARD and QUADAS criteria. RESULTS: Five studies (119 patients) were included. For the diagnosis of brain tumor, FET-PET demonstrated a pooled sensitivity of 0.94 (95% CI: 0.79-0.98) and pooled specificity of 0.88 (95% CI: 0.37-0.99), with an area under the curve of 0.96 (95% CI: 0.94-0.97), a positive likelihood ratio (LR+) of 8.1 (95% CI: 0.8-80.6), and a negative likelihood ratio (LR-) of 0.07 (95% CI: 0.02-0.30), while FDG-PET demonstrated a sensitivity of 0.38 (95% CI: 0.27-0.50) and specificity of 0.86 (95% CI: 0.31-0.99), with an area under the curve of 0.40 (95% CI: 0.36-0.44), an LR+ of 2.7 (95% CI: 0.3-27.8), and an LR- of 0.72 (95% CI: 0.47-1.11). Target-to-background ratios of either FDG or FET, however, allow distinction between low- and high-grade gliomas (P > .11). CONCLUSIONS: For brain tumor diagnosis, FET-PET performed much better than FDG and should be preferred when assessing a new isolated brain tumor. For glioma grading, however, both tracers showed similar performances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hypoxia, a condition of insufficient oxygen availability to support metabolism, occurs when the vascular supply is interrupted, as in stroke. The identification of the hypoxic and viable tissue in stroke as compared with irreversible lesions (necrosis) has relevant implications for the treatment of ischemic stroke. Traditionally, imaging by positron emission tomography (PET), using 15O-based radiotracers, allowed the measurement of perfusion and oxygen extraction in stroke, providing important insights in its pathophysiology. However, these multitracer evaluations are of limited applicability in clinical settings. More recently, specific tracers have been developed, which accumulate with an inverse relationship to oxygen concentration and thus allow visualizing the hypoxic tissue non invasively. These belong to two main groups: nitroimidazoles, and among these the 18F-Fluoroimidazole (18F-FMISO) is the most widely used, and the copper-based tracers, represented mainly by Cu-ATSM. While these tracers have been at first developed and tested in order to image hypoxia in tumors, they have also shown promising results in stroke models and preliminary clinical studies in patients with cardiovascular disorders, allowing the detection of hypoxic tissue and the prediction of the extent of subsequent ischemia and clinical outcome. These tracers have therefore the potential to select an appropriate subgroup of patients who could benefit from a hypoxia-directed treatment and provide prognosis relevant imaging. The molecular imaging of hypoxia made important progress over the last decade and has a potential for integration into the diagnostic and therapeutic workup of patients with ischemic stroke.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Smart canula concept allows for collapsed cannula insertion, and self-expansion within a vein of the body. (A) Computational fluid dynamics, and (B) bovine experiments (76+/-3.8 kg) were performed for comparative analyses, prior to (C) the first clinical application. For an 18F access, a given flow of 4 l/min (A) resulted in a pressure drop of 49 mmHg for smart cannula versus 140 mmHg for control. The corresponding Reynolds numbers are 680 versus 1170, respectively. (B) For an access of 28F, the maximal flow for smart cannula was 5.8+/-0.5 l/min versus 4.0+/-0.1 l/min for standard (P<0.0001), for 24F 5.5+/-0.6 l/min versus 3.2+/-0.4 l/min (P<0.0001), and for 20F 4.1+/-0.3 l/min versus 1.6+/-0.3 l/min (P<0.0001). The flow obtained with the smart cannula was 270+/-45% (20F), 172+/-26% (24F), and 134+/-13% (28F) of standard (one-way ANOVA, P=0.014). (C) First clinical application (1.42 m2) with a smart cannula showed 3.55 l/min (100% predicted) without additional fluids. All three assessment steps confirm the superior performance of the smart cannula design.