48 resultados para Pacemaker


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Within the ORAMED project a coordinated measurement program for occupationally exposed medical staff was performed in different hospitals in Europe. The main objectives of ORAMED were to obtain a set of standardized data on doses for staff in interventional cardiology and radiology and to optimize staff protection. Doses were measured with thermoluminescent dosemeters on the ring finger and wrist of both hands, on legs and at the level of the eyes of the main operator performing interventional procedures. In this paper an overview of the doses per procedure measured during 646 interventional cardiology procedures is given for cardiac angiographies and angioplasties (CA/PTCA), radiofrequency ablations (RFA) and pacemaker and defibrillator implantations (PM/ICD). 31% of the monitored procedures were associated with no collective protective equipment, whereas 44% involved a ceiling screen and a table curtain. Although associated with the smallest air kerma - area product (KAP), PM/ICD procedures led to the highest doses. As expected, KAP and doses values exhibited a very large variability. The left side of the operator, most frequently the closest to the X-ray scattering region, was more exposed than his right side. An analysis of the effect of parameters influencing the doses, namely collective protective equipment, X-ray tube configuration and catheter access route, was performed on the doses normalized to KAP. Ceiling screen and table curtain were observed to reduce normalized doses by atmost a factor 4, much smaller than theoretical attenuation factors typical for such protections, i.e. from 10 to 100. This observation was understood as their inappropriate use by the operators and their non-optimized design. Configurations with tube above the patient led to higher normalized doses to the operator than tube below, but the effect of using a biplane X-ray suite was more complex to analyze. For CA/PTCA procedures, the upper part of the operator's body received higher normalized doses for radial than for femoral catheter access, by atmost a factor 5. This could be seen for cases with no collective protection. The eyes were observed to receive the maximum fraction of the annual dose limit almost as frequently as legs and hands, and clearly the most frequently, if the former 150 mSv and new 20 mSv recommended limits for the lens of the eye are considered, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiac arrhythmias are very frequent in fetuses and newborns. The prognosis depends on the nature of the arrhythmias but is most often either spontaneously benign or following short-term medication administration. A correct diagnosis is essential for both management and prognosis. It is based on echocardiography during the fetal period and mainly on history, physical exam, and electrocardiogram after birth, but other modalities are available to record transient arrhythmic events. Irregular rhythms are mostly benign and rarely require therapy. In most fetuses and infants, tachyarrhythmias resolve spontaneously or require short-term administration of antiarrhythmics. Approximately one third of these may recur later on, especially during adolescence. Persistent bradyarrhythmias might require pacemaker implantation when associated with failure to thrive or with risk of sudden death. CONCLUSION: Arrhythmias in fetuses and infants are very common and mostly benign. History, physical exam, and recording of the arrhythmia are essential to make a correct diagnosis and establish an appropriate management for the rare potentially harmful arrhythmias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electromagnetic fields arising from magnetic resonance imaging (MRI) can cause various clinically relevant functional disturbances in patients with cardiac pacemakers. Consequently, an implanted pacemaker is generally considered a contraindication for an MRI scan. With approximately 60 million MRI scans performed worldwide per year, MRI may be indicated for an estimated majority of pacemaker patients during the lifetime of their pacemakers. The availability of MR conditional pacemakers with CE labelling is of particular advantage since they allow the safe use of pacemakers in MRI. In this article the current state of knowledge on pacemakers and MR imaging is discussed. We present the results of a survey conducted among Swiss radiologists to assess current practice in patients with pacemakers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Atripump is a motorless, volume displacement pump based on artificial muscle technology that could reproduce the pump function of normal atrium. It could help prevent blood clots due to blood stagnation and eventually avoid anticoagulation therapy in atrial fibrillation (AF). An animal study has been designed to assess mechanical effects of this pump on fibrillating atrium. The Atripump is a dome shaped silicone coated nitinol actuator. A pacemaker like control unit drives the actuator. In five adult sheep, the right atrium (RA) was exposed and dome sutured onto the epicardium. Atrial fibrillation was induced using rapid epicardial pacing (600 beats/min). Ejection fraction of the RA was obtained with intracardiac ultrasound in baseline, AF and Atripump assisted AF conditions. The dome's contraction rate was 60/min with power supply of 12V, 400 mA for 200 ms and ran for 2 hours in total. Mean temperature on the RA was 39+/-1.5 degrees C. Right atrium ejection fraction was 31% in baseline conditions, 5% and 20% in AF and assisted AF, respectively. In two animals a thrombus appeared in the right appendix and washed out once the pump was turned on. The Atripump washes blood out the RA acting as an anticoagulant device. Possible clinical implications in patients with chronic AF are prevention of embolism of cardiac origin and avoidance of hemorrhagic complication due to chronic anticoagulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONTEXT: Infection of implantable cardiac devices is an emerging disease with significant morbidity, mortality, and health care costs. OBJECTIVES: To describe the clinical characteristics and outcome of cardiac device infective endocarditis (CDIE) with attention to its health care association and to evaluate the association between device removal during index hospitalization and outcome. DESIGN, SETTING, AND PATIENTS: Prospective cohort study using data from the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), conducted June 2000 through August 2006 in 61 centers in 28 countries. Patients were hospitalized adults with definite endocarditis as defined by modified Duke endocarditis criteria. MAIN OUTCOME MEASURES: In-hospital and 1-year mortality. RESULTS: CDIE was diagnosed in 177 (6.4% [95% CI, 5.5%-7.4%]) of a total cohort of 2760 patients with definite infective endocarditis. The clinical profile of CDIE included advanced patient age (median, 71.2 years [interquartile range, 59.8-77.6]); causation by staphylococci (62 [35.0% {95% CI, 28.0%-42.5%}] Staphylococcus aureus and 56 [31.6% {95% CI, 24.9%-39.0%}] coagulase-negative staphylococci); and a high prevalence of health care-associated infection (81 [45.8% {95% CI, 38.3%-53.4%}]). There was coexisting valve involvement in 66 (37.3% [95% CI, 30.2%-44.9%]) patients, predominantly tricuspid valve infection (43/177 [24.3%]), with associated higher mortality. In-hospital and 1-year mortality rates were 14.7% (26/177 [95% CI, 9.8%-20.8%]) and 23.2% (41/177 [95% CI, 17.2%-30.1%]), respectively. Proportional hazards regression analysis showed a survival benefit at 1 year for device removal during the initial hospitalization (28/141 patients [19.9%] who underwent device removal during the index hospitalization had died at 1 year, vs 13/34 [38.2%] who did not undergo device removal; hazard ratio, 0.42 [95% CI, 0.22-0.82]). CONCLUSIONS: Among patients with CDIE, the rate of concomitant valve infection is high, as is mortality, particularly if there is valve involvement. Early device removal is associated with improved survival at 1 year.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Résumé Introduction : La chirurgie de la maladie de Hirschsprung est fréquemment compliquée d'une atteinte post-opératoire de la motilité intestinale. Des anomalies du système nerveux entérique (SNE) telles que la dysplasie neuronale intestinale de type B, l'hypoganglionose ou l'aganglionose, présents dans le segment abaissé, peuvent être la cause de certaines de ces complications mais aucune information n'est disponible quant au rôle des cellules interstitielles de Cajal (CIC) sur la motilité intestinale dans la phase post-opératoire. Ces cellules sont considérées avoir un rôle de pacemaker dans le tractus gastro-intestinal. L'objectif de cette étude était de décrire la distribution des CIC dans le segment proximal du côlon réséqué lors de cures chirurgicales de maladie de Hirschsprung et de confronter ces observations à l'évolution clinique post-opératoire. Matériel et Méthodes : L'incidence des complications post-opératoires a été déterminée par une revue rétrospective des dossiers de 48 patients opérés pour maladie de Hirschspung entre 1977 et 1999 et par l'étude histologique et immuno-histochimique des pièces réséquées chez ces patients. Nous avons comparé la distribution des CIC dans le segment proximal du côlon avec celle du côlon sain de 16 enfants contrôles par microscopie optique. L'immunohistochimie au c-Kit a été utilisée pour marquer spécifiquement les CIC sur échantillons paraffinés. Ces résultats ont ensuite été corrélés avec l'étude du SNE de ces mêmes segments, déterminée par immunohistochimie au CD56 et au protein gene product 9.5. Résultats Les complications post-opératoires suivantes furent identifiées : constipation 46%, constipation avec incontinence 15%, entérocolite 8%, décès 4% (probablement sur entérocolite). La distribution des CIC dans les segments proximaux réséqués chez les enfants avec maladie de Hirschsprung était identique à celle observée dans les segments de côlon sain, et ce indépendamment de la distribution normale ou anormale du SNE. Chez les enfants opérés pour maladie de Hirschsprung les segments réséqués présentaient les anomalies d'innervation suivantes : aganglionose 10.4%, hypoganglionose 12.5%, dysplasie neuronale intestinale de type B 6.3%, autres dysganglionoses 14.6%. Aucune relation entre ces anomalies d'innervation et les complications post-opératoires n'a été mise en évidence. Conclusion : La distribution des CIC est normale chez les patient opérés pour maladie de Hirschsprung, et ne contribue donc pas aux atteintes post-opératoires de la motilité intestinale. Cela signifie aussi que le réseau de CIC se développe noinialement dans le côlon humain, même en présence d'une innervation colique anormale ou absente. Abstract: Surgery for Hirschsprung's disease is often complicated by post-operative bowel motility disorders. The impact of intestinal neural histology on the surgical outcome has been previously studied, but no information is available concerning the influence of the distribution of interstitial cells of Cajal (ICC) on these complications. These cells are considered to be pacemakers in the gastrointestinal tract. The aim of this study was to assess the distribution of ICC in the proximal segment of resected bowel in Hirschsprung's disease and confront these results with the clinical outcome. Using immunohistochemistry for light microscopy, we compared the pattern of distribution of ICC in the proximal segment of resected bowel in Hirschsprung's disease with that in normal colon. We correlated these results with the corresponding neural intestinal histology determined by CD56 and the protein gene product 9.5 immunohistochemistry. The distribution of ICC in the proximal segment of resected bowel is identical to that of normal colon, regardless of normal or abnormal colon innervation. ICC distribution does not seem to contribute to post-operative bowel motility disorders in patients operated for Hirschsprung's disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Isolated congenital atrioventricular block (CAVB) diagnosed in utero is associated with a high morbidity and mortality. Prognosis is especially poor when heart rate drops below 55 beats per minute (bpm) and when fetal hydrops develops. We describe the natural history and outcome of 24 infants with isolated CAVB diagnosed in utero, review the literature, and assess the risk factors that could predict outcome. METHODS: This was a retrospective multicenter study of 24 patients with isolated CAVB diagnosed in utero. RESULTS: CAVB was detected at a mean gestational age (GA) of 24.7 +/- 5.1 weeks. Ten fetuses initially presented with complete heart block. Low heart rate or incomplete heart block was the first documentation of bradyarrhythmia in the other 14 fetuses. In 11 of them, CAVB developed during pregnancy after a median time of 3 (range 1-16) weeks. Fetal hydrops developed in 10 of 24 (42%) fetuses at a mean GA of 27.6 +/- 5.1 weeks. Hydropic fetuses showed lower heart rates during pregnancy (47 +/- 10 bpm) than non-hydropic fetuses (57 +/- 10 bpm). There were three intrauterine deaths; all were hydropic and female. Nine viable females and 12 males were born at a mean GA of 37.1 +/- 6.1 weeks with an average birth weight of 3097 +/- 852 g. Fifteen CAVB patients required pacemaker (PM) intervention, 10 of them immediately after birth. Dilated cardiomyopathy (DCM) developed in three infants of whom two died of congestive heart failure, shortly after the diagnosis was made; one is still alive. Mortality before or after birth was 21%, and was associated with heart rates below 50 bpm and development of fetal hydrops. Poor outcome, defined as death, PM implantation, or development of DCM, occurred in 83% of cases and was associated with heart rates below 60 bpm during pregnancy. CONCLUSIONS: Isolated CAVB diagnosed in utero is associated with high morbidity and mortality. Patients who develop fetal hydrops show lower heart rates during pregnancy than patients who do not. A fetal heart rate below 50 bpm and development of fetal hydrops is associated with increased mortality. Rates below 60 bpm are associated with PM requirement and/or DCM.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mammalian circadian timing system consists of a master pacemaker in the suprachiasmatic nucleus (SCN) in the hypothalamus, which is thought to set the phase of slave oscillators in virtually all body cells. However, due to the lack of appropriate in vivo recording technologies, it has been difficult to study how the SCN synchronizes oscillators in peripheral tissues. Here we describe the real-time recording of bioluminescence emitted by hepatocytes expressing circadian luciferase reporter genes in freely moving mice. The technology employs a device dubbed RT-Biolumicorder, which consists of a cylindrical cage with reflecting conical walls that channel photons toward a photomultiplier tube. The monitoring of circadian liver gene expression revealed that hepatocyte oscillators of SCN-lesioned mice synchronized more rapidly to feeding cycles than hepatocyte clocks of intact mice. Hence, the SCN uses signaling pathways that counteract those of feeding rhythms when their phase is in conflict with its own phase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrical pacing at physiological rate induces myocardial remodeling associated with regional changes in workload, blood flow and oxygen consumption. However, to what extent energy-producing pathways are also modified within the paced heart remains to be investigated. Pacing could particularly affect glycogen metabolism since hypertrophy stimulates glycolysis and increased workload favors glucose over fat oxidation. In order to test this hypothesis, we used the embryonic chick heart model in which ventricular pacing rapidly resulted in thinning of the ventricle wall and thickening of the atrial wall. Hearts of stage 22HH chick embryos were submitted in ovo to asynchronous and intermittent ventricular pacing delivered at physiological rate during 24 h. The resulting alterations of glycogen content were determined in atrium, ventricle and conotruncus of paced and sham-operated hearts. Hemodynamic parameters of the paced and spontaneously beating hearts were derived from computerized image analysis of video recordings. With respect to sham, paced hearts showed a significant decrease in glycogen content (nmoles glucose units/microg protein; mean+/-S.D.) only in atrium (1.48+/-0.40 v 0.84+/-0.34, n=8) and conotruncus (0.75+/-0.28 v 0.42+/-0.23, n=8). Pacing decreased the end diastolic and stroke volumes by 34 and 44%, respectively. Thus, the rapid glycogen depletion in regions remote from the stimulation site appears to be associated with regional changes in workload and remodeling. These findings underscore the importance of the coupling mechanisms between metabolic pathways and myocardial remodeling in the ectopically paced heart.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Circadian and sleep-homeostatic processes both contribute to sleep timing and sleep structure. Elimination of circadian rhythms through lesions of the suprachiasmatic nuclei (SCN), the master circadian pacemaker, leads to fragmentation of wakefulness and sleep but does not eliminate the homeostatic response to sleep loss as indexed by the increase in EEG delta power. In humans, EEG delta power declines during sleep episodes nearly independently of circadian phase. Such observations have contributed to the prevailing notion that circadian and homeostatic processes are separate but recent data imply that this segregation may not extend to the molecular level. Here we summarize the criteria and evidence for a role for clock genes in sleep homeostasis. Studies in mice with targeted disruption for core circadian clock genes have revealed alterations in circadian rhythmicity as well as changes in sleep duration, sleep structure and EEG delta power. Clock-gene expression in brain areas outside the SCN, in particular the cerebral cortex, depends to a large extent on prior sleep-wake history. Evidence for effects of clock genes on sleep homeostasis has also been obtained in Drosophila and humans, pointing to a phylogenetically preserved pathway. These findings suggest that, while within the SCN clock genes are utilized to set internal time-of-day, in the forebrain the same feedback circuitry may be utilized to track time spent awake and asleep. The mechanisms by which clock-gene expression is coupled to the sleep-wake distribution could be through cellular energy charge whereby clock genes act as energy sensors. The data underscore the interrelationships between energy metabolism, circadian rhythmicity, and sleep regulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modern urban lifestyle encourages the prolongation of wakefulness, leaving less and less time for sleep. Although the exact functions of sleep remain one of the biggest mysteries in neuroscience, the society is well aware of the negative consequences of sleep loss on human physical and mental health and performance. Enhancing sleep's recuperative functions might allow shortening sleep duration while preserving the beneficial effects of sleep. During sleep, brain activity oscillates across a continuum of frequencies. Individual oscillations have been suggested to underlie distinct functions for sleep and cognition. Gaining control about individual oscillations might allow boosting their specific functions. Sleep spindles are 11 - 15 Hz oscillations characteristic for light non-rapid-eye-movement sleep (NREMS) and have been proposed to play a role in memory consolidation and sleep protection against environmental stimuli. The reticular thalamic nucleus (nRt) has been identified as the major pacemaker of spindles. Intrinsic oscillatory burst discharge in nRt neurons, arising from the interplay of low-threshold (T-type) Ca2+ channels (T channels) and small conductance type 2 (SK2) K+ channels (SK2 channels), underlies this pacemaking function. In the present work we investigated the impact of altered nRt bursting on spindle generation during sleep by studying mutant mice for SK2 channels and for CaV3.3 channels, a subtype of T channels. Using in vitro electrophysiology I showed that nRt bursting was abolished in CaV3.3 knock out (CaV3.3 KO) mice. In contrast, in SK2 channel over-expressing (SK2-OE) nRt cells, intrinsic repetitive bursting was prolonged. Compared to wildtype (WT) littermates, altered nRt burst discharge lead to weakened thalamic network oscillations in vitro in CaV3.3 KO mice, while oscillatory activity was prolonged in SK2-OE mice. Sleep electroencephalographic recordings in CaV3.3 KO and SK2-OE mice revealed that reduced or potentiated nRt bursting respectively weakened or prolonged sleep spindle activity at the NREMS - REMS transition. Furthermore, SK2-OE mice showed more consolidated NREMS and increased arousal thresholds, two correlates of good sleep quality. This thesis work suggests that CaV3.3 and SK2 channels may be targeted in order to modulate sleep spindle activity. Furthermore, it proposes a novel function for spindles in NREMS consolidation. Finally, it provides evidence that sleep quality may be improved by promoting spindle activity, thereby supporting the hypothesis that sleep quality can be enhanced by modulating oscillatory activity in the brain. Le style de vie moderne favorise la prolongation de l'éveil, laissant de moins en moins de temps pour le sommeil. Même si le rôle exact du sommeil reste un des plus grands mystères des neurosciences, la société est bien consciente des conséquences négatives que provoque un manque de sommeil, à la fois sur le plan de la santé physique et mentale ainsi qu'au niveau des performances cognitives. Augmenter les fonctions récupératrices du sommeil pourrait permettre de raccourcir la durée du sommeil tout en en conservant les effets bénéfiques. Durant le sommeil, on observe des oscillations à travers un continuum de fréquences. Il a été proposé que chaque oscillation pourrait être à l'origine de fonctions spécifiques pour le sommeil et la cognition. Pouvoir de contrôler les oscillations individuelles permettrait d'augmenter leurs fonctions respectives. Les fuseaux sont des oscillations de 11 à 15 Hz caractéristiques du sommeil à ondes lentes léger et il a été suggéré qu'elles jouent un rôle majeur pour la consolidation de la mémoire ainsi que dans la protection du sommeil contre les stimuli environnementaux. Le nucleus réticulaire du thalamus (nRt) a été identifié en tant que générateur de rythme des fuseaux. Les bouffées oscillatoires intrinsèques des neurones du nRt, provenant de l'interaction de canaux calciques à bas seuil de type T (canaux T) et de canaux potassiques à faible conductance de type 2 (canaux SK2), sont à l'origine de la fonction de générateur de rythme. Dans ce travail, j'ai étudié l'impact de la modulation de bouffées de nRT sur la génération des fuseaux pendant le sommeil en investiguant des souris génétiquement modifiées pour les canaux SK2 et les canaux CaV3.3, un sous-type de canaux T. En utilisant l'électrophysiologie in vitro j'ai démontré que les bouffées du nRT étaient abolies dans les souris knock-out du type CaV3.3 (CaV3.3 KO). D'autre part, dans les cellules nRT sur-exprimant les canaux SK2 (SK2-OE), les bouffées oscillatoires intrinsèques étaient prolongées. Par rapport aux souris wild type, les souris CaV3.3 KO ont montré un affaiblissement des oscillations thalamiques en réponse à un changement des bouffées de nRT, alors que l'activité oscillatoire était prolongée dans les souris SK2-OE. Des enregistrements EEG du sommeil dans des souris de type CaV3.3 KO et SK2-OE ont révélé qu'une réduction ou augmentation des bouffées nRT ont respectivement affaibli ou prolongé l'activité des fuseaux durant les transitions du sommeil à ondes lentes au sommeil paradoxal. De plus, les souris SK2-OE ont montré des signes de consolidation du sommeil à ondes lentes et un seuil augmenté pour le réveil, deux mesures qui corrèlent avec une bonne qualité du sommeil. Le travail de cette thèse propose que les canaux CaV3.3 et SK2 pourrait être ciblés pour moduler l'activité des fuseaux. De plus, je propose une fonction nouvelle pour les fuseaux dans la consolidation du sommeil à ondes lentes. Finalement je suggère que la qualité du sommeil peut être améliorée en promouvant l'activité des fuseaux, soutenant ainsi l'idée que la qualité du sommeil peut être améliorée en modulant l'activité oscillatoire dans le cerveau.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Experimental models have reported conflicting results regarding the role of dispersion of repolarization in promoting atrial fibrillation (AF). Repolarization alternans, a beat-to-beat alternation in action potential duration, enhances dispersion of repolarization when propagation velocity is involved. METHODS AND RESULTS: In this work, original electrophysiological parameters were analysed to study AF susceptibility in a chronic sheep model of pacing-induced AF. Two pacemakers were implanted, each with a single right atrial lead. Right atrial depolarization and repolarization waves were documented at 2-week intervals. A significant and gradual decrease in the propagation velocity at all pacing rates and in the right atrial effective refractory period (ERP) was observed during the weeks of burst pacing before sustained AF developed when compared with baseline conditions. Right atrial repolarization alternans was observed, but because of the development of 2/1 atrioventricular block with far-field ventricular interference, its threshold could not be precisely measured. Non-sustained AF was not observed at baseline, but appeared during the electrical remodelling in association with a decrease in both ERP and propagation velocity. CONCLUSION: We report here on the feasibility of measuring ERP, atrial repolarization alternans, and propagation velocity kinetics and their potential in predicting susceptibility to AF in a free-behaving model of pacing-induced AF using the standard pacemaker technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to evaluate the risk factors associated with Contegra graft (Medtronic Minneapolis, MN, USA) infection after reconstruction of the right ventricular outflow tract. METHODS: One hundred and six Contegra grafts were implanted between April 1999 and April 2010 for the Ross procedure (n = 46), isolated pulmonary valve replacement (n = 32), tetralogy of Fallot (n = 24), double-outlet right ventricle (n = 7), troncus arteriosus (n = 4), switch operation (n = 1) and redo of pulmonary valve replacement (n = 2). The median age of the patients was 13 years (range 0-54 years). A follow-up was completed in all cases with a median duration of 7.6 years (range 1.7-12.7 years). RESULTS: There were 3 cases of in-hospital mortality. The survival rate during 7 years was 95.7%. Despite the lifelong endocarditis prophylaxis, Contegra graft infection was diagnosed in 12 (11.3%) patients at a median time of 4.4 years (ranging from 0.4 to 8.7 years). Univariate analysis of preoperative, perioperative and postoperative variables was performed and the following risk factors for time to infection were identified: female gender with a hazard ratio (HR) of 0.19 (P = 0.042), systemic-to-pulmonary shunt (HR 6.46, P < 0.01), hypothermia (HR 0.79, P = 0.014), postoperative renal insufficiency (HR 11.97, P = 0.015) and implantation of permanent pacemaker during hospitalization (HR 5.29, P = 0.075). In 2 cases, conservative therapy was successful and, in 10 patients, replacement of the infected valve was performed. The Contegra graft was replaced by a homograft in 2 cases and by a new Contegra graft in 8 cases. Cox's proportional hazard model indicated that time to graft infection was significantly associated with tetralogy of Fallot (HR 0.06, P = 0.01), systemic-to-pulmonary shunt (HR 64.71, P < 0.01) and hypothermia (HR 0.77, P < 0.01). CONCLUSION: Contegra graft infection affected 11.3% of cases in our cohort, and thus may be considered as a frequent entity that can be predicted by both intraoperative and early postoperative factors. After the diagnosis of infection associated with the Contegra graft was confirmed, surgical treatment was the therapy of choice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Atrial fibrillation is a very common heart arrhythmia, associated with a five-fold increase in the risk of embolic strokes. Treatment strategies encompass palliative drugs or surgical procedures all of which can restore sinus rhythm. Unfortunately, atria often fail to recover their mechanical function and patients therefore require lifelong anticoagulation therapy. A motorless volume displacing device (Atripump) based on artificial muscle technology, positioned on the external surface of atrium could avoid the need of oral anticoagulation and its haemorrhagic complications. An animal study was conducted in order to assess the haemodynamic effects that such a pump could provide. METHODS: Atripump is a dome-shape siliconecoated nitinol actuator sewn on the external surface of the atrium. It is driven by a pacemaker-like control unit. Five non-anticoagulated sheep were selected for this experiment. The right atrium was surgically exposed, the device sutured and connected. Haemodynamic parameters and intracardiac ultrasound (ICUS) data were recorded in each animal and under three conditions; baseline; atrial fibrillation (AF); atripump assisted AF (aaAF). RESULTS: In two animals, after 20 min of AF, small thrombi appeared in the right atrial appendix and were washed out once the pump was turned on. Assistance also enhanced atrial ejection fraction. 31% baseline; 5% during AF; 20% under aaAF. Right atrial systolic surfaces (cm2) were; 5.2 +/- 0.3 baseline; 6.2 +/- 0.1 AF; 5.4 +/- 0.3 aaAF. CONCLUSION: This compact and reliable pump seems to restore the atrial "kick" and prevents embolic events. It could avoid long-term anticoagulation therapy and open new hopes in the care of end-stage heart failure.