65 resultados para POLYETHYLENE
Resumo:
Vaniprevir (MK-7009) is a macrocyclic hepatitis C virus (HCV) nonstructural protein 3/4A protease inhibitor. The aim of the present phase II study was to examine virologic response rates with vaniprevir in combination with pegylated interferon alpha-2a (Peg-IFN-α-2a) plus ribavirin (RBV). In this double-blind, placebo-controlled, dose-ranging study, treatment-naïve patients with HCV genotype 1 infection (n = 94) were randomized to receive open-label Peg-IFN-α-2a (180 μg/week) and RBV (1,000-1,200 mg/day) in combination with blinded placebo or vaniprevir (300 mg twice-daily [BID], 600 mg BID, 600 mg once-daily [QD], or 800 mg QD) for 28 days, then open-label Peg-IFN-α-2a and RBV for an additional 44 weeks. The primary efficacy endpoint was rapid viral response (RVR), defined as undetectable plasma HCV RNA at week 4. Across all doses, vaniprevir was associated with a rapid two-phase decline in viral load, with HCV RNA levels approximately 3 log(10) IU/mL lower in vaniprevir-treated patients, compared to placebo recipients. Rates of RVR were significantly higher in each of the vaniprevir dose groups, compared to the control regimen (68.8%-83.3% versus 5.6%; P < 0.001 for all comparisons). There were numerically higher, but not statistically significant, early and sustained virologic response rates with vaniprevir, as compared to placebo. Resistance profile was predictable, with variants at R155 and D168 detected in a small number of patients. No relationship between interleukin-28B genotype and treatment outcomes was demonstrated in this study. The incidence of adverse events was generally comparable between vaniprevir and placebo recipients; however, vomiting appeared to be more common at higher vaniprevir doses. CONCLUSION: Vaniprevir is a potent HCV protease inhibitor with a predictable resistance profile and favorable safety profile that is suitable for QD or BID administration.
Resumo:
Background: Switzerland was the first country to approve certolizumab pegol (Cimzia, CZP) for the treatment of patients with moderate to severe Crohn's disease (CD) in September 2007. This phase IV study aimed to evaluate the efficacy and safety of CZP in a Swiss multicenter cohort of practice-based patients. Methods: Baseline and Week 6 evaluation questionnaires were sent to all Swiss gastroenterologists in hospitals and private practices. Disease activity was assessed with the Harvey-Bradshaw Index (HBI) and adverse events were evaluated according to WHO guidelines. Results: Fifty patients (31 women, 19 men) were included; 56% had complicated disease (stricture or fistula) and 52% had undergone prior CD-related surgery. All patients. had prior exposure to systemic steroids, 96% to immunomodulators, 78% to infliximab, and 50% to adalimumab. A significant decrease in HBI was observed at Week 6 (versus Week 0) following induction therapy with CZP 400 mg subcutaneously at Weeks 0, 2, and 4 (12.6 +/- 4.7 Week 0 versus 6.2 +/- 4.4 Week 6, P < 0.001). Response and remission rates at Week 6 were 54% and 40%, respectively. We identified 8/11 CD patients undergoing a 50% fistula response (P = 0.021). The frequency of adverse drug reactions attributed to CZP was 6%. CZP was continued in 80% of patients beyond Week 6. Conclusions: In a population of CD patients with complicated disease behavior, CZP induced a response and remission in 54% and 40% of patients, respectively. This series provides the first evidence of the effectiveness of CZP in perianal fistulizing CD.
Resumo:
BACKGROUND: Certolizumab pegol (Cimzia, CZP) was approved for the treatment of Crohn's disease (CD) patients in 2007 in Switzerland as the first country worldwide. This prospective phase IV study aimed to evaluate the efficacy and safety of CZP over 26 weeks in a multicenter cohort of practice-based patients. METHODS: Evaluation questionnaires at baseline, week 6, and week 26 were completed by gastroenterologists in hospitals and private practices. Adverse events were evaluated according to World Health Organization (WHO) guidelines. RESULTS: Sixty patients (38F/22M) were included; 53% had complicated disease (stricturing or penetrating), 45% had undergone prior CD-related surgery. All patients had prior exposure to systemic steroids, 96% to immunomodulators, 73% to infliximab, and 43% to adalimumab. A significant decrease of the Harvey-Bradshaw Index (HBI) was observed under CZP therapy (12.2 ± 4.9 at week 0 versus 6.3 ± 4.7 at week 6 and 6.7 ± 5.3 at week 26, both P < 0.001). Response and remission rates were 70% and 40% (week 6) and 67% and 36%, respectively (week 26). The complete perianal fistula closure rate was 36% at week 6 and 55% at week 26. The frequency of adverse drug reactions attributed to CZP was 5%. CZP was continued in 88% of patients beyond week 6 and in 67% beyond week 26. CONCLUSIONS: In a population of CD patients with predominantly complicated disease behavior, CZP proved to be effective in induction and maintenance of response and remission. This series provides the first evidence of CZP's effectiveness in perianal fistulizing CD in clinical practice.
Resumo:
Due to the eye's specific anatomical and physiological conformation, the treatment of eye diseases is a real challenge for pharmaceutical therapy. The presence of efficient protective barriers (i.e., the conjunctival and corneal membranes) and protective mechanisms (i.e., blinking and nasolachrymal drainage) makes this organ particularly impervious to local drug therapy. To overcome these issues, numerous strategies have been envisioned using pharmaceutical technology. Many formulations currently on the market or still under development are emulsions or colloidal systems intended to enhance precorneal residence time and corneal penetration, causing a consequent increase in drug bioavailability after instillation. After a review of some recent developments in the field of cyclosporin A formulations for the eye, a novel micellar formulation of cyclosporine A based on a diblock methoxy-poly(ethylene glycol)-hexysubstituted poly(lactides) (MPEG-hexPLA) is described.
Resumo:
OBJECTIVES: Tissue engineering methods can be applied to regenerate diseased, or congenitally missing, urinary tract tissues. Urinary tract tissue cell cultures must be established in vitro and adequate matrices, acting as cell carriers, must be developed. Although degradable and nondegradable polymer matrices offer adequate mechanical stability, they are not optimal for cell adherence and growth. To overcome this problem, extracellular matrix proteins, permitting cell adhesion and regulation of cell proliferation and differentiation, can be adsorbed to the surface-modified polymer. METHODS: In this study, nondegradable polymer films, poly(ethylene terephthalate), were used as an experimental model. Films were modified by graft polymerization of acrylic acid to subsequently allow collagen type I and III immobilization. The following adhesion, proliferation of human urothelial cells, and induction of their stratification were analyzed. RESULTS: Collagen adsorption on 0.2 microg/cm2 poly(acrylic acid)-grafted polymer films rendered the matrix apt for human urothelial cell adhesion and proliferation. Furthermore, stratification of urothelial cells was demonstrated on these surface-modified matrices. CONCLUSIONS: These results have shown that surface-modified polymer matrices can be used to act as cell carriers for cultured human urothelial cells. Such a cell-matrix construct could be applied in reparative surgery of the urinary tract.
Resumo:
This study shows the efficiency of passive sampling to reveal industrial and agricultural pollution trends. Two practical applications for nonpolar and polar contaminants are presented. Low-density polyethylene (LDPE) samplers were deployed for one year in the Venoge River (VD) to monitor indicator PCBs (iPCBs, IUPAC nos. 28, 52, 101, 138, 153 and 180). The results showed that the impact of PCB emissions into the river is higher in summer than in other seasons due to the low flow rate of the river during this period. P,olar organic chemical integrative samplers (POCIS) were deployed for 4 months in the Sion-Riddes canal (VS) to investigate herbicides (terbuthylazine, diuron and linuron). Desisopropylatrazine-d5 (DIA-d5) was tested as a performance reference compound (PRC) to estimate aqueous concentration. The results showed an increase of water contamination due to the studied agricultural area. The maximal contamination was observed in April and corresponds to the period of herbicide application on the crops.
Resumo:
In Switzerland, individuals exposed to the risk of activity intake are required to perform regular monitoring. Monitoring consists in a screening measurement and is meant to be performed using commonly available laboratory instruments. More particularly, iodine intake is measured using a surface contamination monitor. The goal of the present paper is to report the calibration method developed for thyroid screening instruments. It consists of measuring the instrument response to a known activity located in the thyroid gland of a standard neck phantom. One issue of this procedure remains that the iodine radioisotopes have a short half-life. Therefore, the adequacy and limitations to simulate the short-lived radionuclides with so-called mock radionuclides of longer half-life were also evaluated. In light of the results, it has been decided to use only the appropriate iodine sources to perform the calibration.
Resumo:
Purpose Third generation anatomic total shoulder prostheses offer a wide range of adaptability (size, thickness, retroversion and offset of the humeral head, cervico-diaphyseal angle) in order to reproduce anatomy and biomechanics of the shoulder as normal as possible. The large variability of the implants may also induce malposition. Our goal was to analyse the consequences of a humeral head malposition, which is one of the most frequent placement errors. Material and Methods A 3D finite element model of the glenohumeral joint, including the rotator cuff muscles and the deltoid, was used with the Aequalis anatomic prosthesis. Active abduction was simulated. Three humeral head placements were compared : anatomic positioning (A), 5 mm inferior positioning (B), 5 mm superior positioning (C). The effect of humeral head malposition was evaluated through the following quantities : the range of motion free of impingements, the glenohumeral contact pattern, and the stress within the polyethylene and the cement. Results Inferior positioning (B) of the humeral head produced a superior impingement before 90° of abduction, an inferior eccentric contact point on the glenoid, and 165% increase of cement stress. Superior positioning (C) of the humeral head produced a postero-superior eccentric contact point on the glenoid, 300% increase of glenohumeral contact pressure, 450% increase of polyethylene stress, and 207% increase of cement stress. Conclusion Malposition of the humeral head of anatomic prostheses induces biomechanical consequences that may preclude the glenoid survival. Particular attention must be paid to reproduce the humeral anatomy as normal as possible.
Resumo:
Hepatitis D virus (HDV) is a subviral agent which depends on the envelope proteins (HBsAg) of hepatitis B virus (HBV). Therefore, hepatitis D is observed only in patients infected with HBV. Chronic hepatitis D is the least frequent albeit most severe form of chronic viral hepatitis. A resurgence of chronic hepatitis D has been observed in Northern and Central Europe, mainly due to immigration of patients from regions with high prevalence. Every HBsAg-positive patient should be screened for concurrent HDV infection. Standard treatment consists of pegylated interferon-alpha for at least one year. Sustained virological response rates are approximately 20%. Liver transplantation should be considered in patients with advanced cirrhosis or limited hepatocellular carcinoma. Preventive measures for hepatitis D are the same as for hepatitis B.
Resumo:
A new and original reagent based on the use of highly fluorescent cadmium telluride (CdTe) quantum dots (QDs) in aqueous solution is proposed to detect weak fingermarks in blood on non-porous surfaces. To assess the efficiency of this approach, comparisons were performed with one of the most efficient blood reagents on non-porous surfaces, Acid Yellow 7 (AY7). To this end, four non-porous surfaces were studied, i.e. glass, transparent polypropylene, black polyethylene, and aluminium foil. To evaluate the sensitivity of both reagents, sets of depleted fingermarks were prepared, using the same finger, initially soaked with blood, which was then successively applied on the same surface without recharging it with blood or latent secretions. The successive marks were then cut in halves and the halves treated separately with each reagent. The results showed that QDs were equally efficient to AY7 on glass, polyethylene and polypropylene surfaces, and were superior to AY7 on aluminium. The use of QDs in new, sensitive and highly efficient latent and blood mark detection techniques appears highly promising. Health and safety issues related to the use of cadmium are also discussed. It is suggested that applying QDs in aqueous solution (and not as a dry dusting powder) considerably lowers the toxicity risks.
Resumo:
Total shoulder arthroplasty (TSA) is an accepted and most successfully used treatment for different shoulder pathologies. Different risk factors for the failure of the prosthesis are known. A pathological scapular orientation, observed in elderly people or in patients suffering from neuromuscular diseases, could be a cause of failure, which has not been investigated yet. To test this hypothesis, a numerical musculoskeletal model of the glenohumeral joint was used to compare two TSA cases: a reference normal case and a case with a pathological anterior tilt of the scapula. An active abduction of 150° was simulated. Joint force, contact pattern, polyethylene and cement stress were evaluated for both cases. The pathological tilt slightly increased the joint force and the contact pressure, but also shifted the contact pattern. This eccentric contact increased the stress level within the polyethylene of the glenoid component and within the surrounding cement layer. This adverse effect occurred mainly during the first 60° of abduction. Therefore, a pathological orientation of the scapula may increase the risk of a failure of the cement layer around the glenoid component. These preliminary numerical results should be confirmed by a clinical study.
Resumo:
BACKGROUND/AIMS: Treatment of chronic HCV infection has become a priority in HIV+ patients, given the faster progression to end-stage liver disease. The primary endpoint of this study was to evaluate and compare antiviral efficacy of Peginterferon alpha 2a plus ribavirin in HIV-HCV co-infected and HCV mono-infected patients, and to examine whether 6 months of therapy would have the same efficacy in HIV patients with favourable genotypes 2 and 3 as in mono-infected patients, to minimise HCV-therapy-related toxicities. Secondary endpoints were to evaluate predictors of sustained virological response (SVR) and frequency of side-effects. METHODS: Patients with genotypes 1 and 4 were treated for 48 weeks with Pegasys 180 microg/week plus Copegus 1000-1200 mg/day according to body weight; patients with genotypes 2 and 3 for 24 weeks with Pegasys 180 microg/week plus Copegus 800 mg/day. RESULTS: 132 patients were enrolled in the study: 85 HCV mono-infected (38: genotypes 1 and 4; 47: genotypes 2 and 3), 47 HIV-HCV co-infected patients (23: genotypes 1 and 4; 24: genotypes 2 and 3). In an intention-to-treat analysis, SVR for genotypes 1 and 4 was observed in 58% of HCV mono-infected and in 13% of HIV-HCV co-infected patients (P = 0.001). For genotypes 2 and 3, SVR was observed in 70% of HCV mono-infected and in 67% of HIV-HCV co-infected patients (P = 0.973). Undetectable HCV-RNA at week 4 had a positive predictive value for SVR for mono-infected patients with genotypes 1 and 4 of 0.78 (95% CI: 0.54-0.93) and of 0.81 (95% CI: 0.64-0.92) for genotypes 2 and 3. For co-infected patients with genotypes 2 and 3, the positive predictive value of SVR of undetectable HCV-RNA at week 4 was 0.76 (95%CI, 0.50-0.93). Study not completed by 22 patients (36%): genotypes 1 and 4 and by 12 patients (17%): genotypes 2 and 3. CONCLUSION: Genotypes 2 or 3 predict the likelihood of SVR in HCV mono-infected and in HIV-HCV co-infected patients. A 6-month treatment with Peginterferon alpha 2a plus ribavirin has the same efficacy in HIV-HCV co-infected patients with genotypes 2 and 3 as in mono-infected patients. HCV-RNA negativity at 4 weeks has a positive predictive value for SVR. Aggressive treatment of adverse effects to avoid dose reduction, consent withdrawal or drop-out is crucial to increase the rate of SVR, especially when duration of treatment is 48 weeks. Sixty-one percent of HIV-HCV co-infected patients with genotypes 1 and 4 did not complete the study against 4% with genotypes 2 and 3.
Resumo:
Introduction: Several studies have reported significant alteration of the scapula-humeral rythm after total shoulder arthroplasty. However, the biomechanical and clinical effects, particularly on implants lifespan, are still unknown. The goal of this study was to evaluate the biomechanical consequences of an altered scapula-humeral rhythm. Methods: A numerical musculoskeletal model of the shoulder was used. The model included the scapula, the humerus and 6 scapulohumeral muscles: middle, anterior, and posterior deltoid, supraspinatus, subscapularis and infraspinatus combined with teres minor. Arm motion and joint stability were achieved by muscles. The reverse and anatomic Aequalis prostheses (Tornier Inc) were inserted. Two scapula-humeral rhythms were considered for each prosthesis: a normal 2:1 rhythm, and an altered 1:2 rhythm. For the 4 configurations, a movement of abduction in the scapular plane was simulated. The gleno-humeral force and contact pattern, but also the stress in the polyethylene and cement were evaluated. Results: With the anatomical prosthesis, the gleno-humeral force increased of 23% for the altered rhythm, with a more eccentric (posterior and superior) contact. The contact pressure, polyethylene stress, and cement stress increased respectively by 20%, 48% and 64%. With the reverse prosthesis, the gleno-humeral force increased of 11% for an altered rhythm. There was nearly no effect on the contact pattern on the polyethylene component surface. Conclusion: The present study showed that alteration oft the scapula-humeral rythm induced biomechanical consequences which could preclude the long term survival of the glenoid implant of anatomic prostheses. However,an altered scapula-humeral rhythm, even severe, should not be a contra indication for the use of a reverse prosthesis.