165 resultados para Optimal values


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cost effective means of assessing the levels of risk factors in the population have to be defined in order to monitor these factors over time and across populations. This study is aimed at analyzing the difference in population estimates of the mean levels of body mass index (BMI) and the prevalences of overweight, between health examination survey and telephone survey. METHODS: The study compares the results of two health surveys, one by telephone (N=820) and the other by physical examination (N=1318). The two surveys, based on independent random samples of the population, were carried out over the same period (1992-1993) in the same population (canton of Vaud, Switzerland). RESULTS: Overall participation rates were 67% and 53% for the health interview survey (HIS) and the health examination survey (HES) respectively. In the HIS, the reporting rate was over 98% for weight and height values. Self-reported weight was on average lower than measured weight, by 2.2 kg in men and 3.5 kg in women, while self-reported height was on average greater than measured height, by 1.2 cm in men and 1.9 cm in women. As a result, in comparison to HES, HIS led to substantially lower mean levels of BMI, and to a reduction of the prevalence rates of obesity (BMI>30 kg/m(2)) by more than a half. These differences are larger for women than for men. CONCLUSION: The two surveys were based on different sampling procedures. However, this difference in design is unlikely to explain the systematic bias observed between self-reported and measured values for height and weight. This bias entails the overall validity of BMI assessment from telephone surveys.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Imatinib has been increasingly proposed for therapeutic drug monitoring (TDM), as trough concentrations (Cmin) correlate with response rates in CML patients. This analysis aimed to evaluate the impact of imatinib exposure on optimal molecular response rates in a large European cohort of patients followed by centralized TDM.¦Methods: Sequential PK/PD analysis was performed in NONMEM 7 on 2230 plasma (PK) samples obtained along with molecular response (PD) data from 1299 CML patients. Model-based individual Bayesian estimates of exposure, parameterized as to initial dose adjusted and log-normalized Cmin (log-Cmin) or clearance (CL), were investigated as potential predictors of optimal molecular response, while accounting for time under treatment (stratified at 3 years), gender, CML phase, age, potentially interacting comedication, and TDM frequency. PK/PD analysis used mixed-effect logistic regression (iterative two-stage method) to account for intra-patient correlation.¦Results: In univariate analyses, CL, log-Cmin, time under treatment, TDM frequency, gender (all p<0.01) and CML phase (p=0.02) were significant predictors of the outcome. In multivariate analyses, all but log-Cmin remained significant (p<0.05). Our model estimates a 54.1% probability of optimal molecular response in a female patient with a median CL of 14.4 L/h, increasing by 4.7% with a 35% decrease in CL (percentile 10 of CL distribution), and decreasing by 6% with a 45% increased CL (percentile 90), respectively. Male patients were less likely than female to be in optimal response (odds ratio: 0.62, p<0.001), with an estimated probability of 42.3%.¦Conclusions: Beyond CML phase and time on treatment, expectedly correlated to the outcome, an effect of initial imatinib exposure on the probability of achieving optimal molecular response was confirmed in field-conditions by this multivariate analysis. Interestingly, male patients had a higher risk of suboptimal response, which might not exclusively derive from their 18.5% higher CL, but also from reported lower adherence to the treatment. A prospective longitudinal study would be desirable to confirm the clinical importance of identified covariates and to exclude biases possibly affecting this observational survey.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Isotopic, geochemical and bulk mineralogical analyses in the Trabakua and Ermua sections, Basque Basin, reveal major changes across the Paleocene-Eocene transition. Expanded sedimentary records exhibit a gradual decrease of 1.0 parts per thousand in delta(13)C values in the lower part of Zone P5 followed by a more rapid 3 parts per thousand negative excursion. The 3 parts per thousand delta(13)C excursion is associated with an abrupt decrease in carbonate sedimentation, increased detrital flux and decreased grain size which suggest changes in marine/atmospheric currents and/or size and structure of the ocean carbon reservoir. The clays recognized at Trabakua record a deep burial diagenesis as indicated by two generations of chlorite, the presence of mixed-layers chlorite-smectite and illite-smectite, the absence of smectite and the near absence of kaolinite. The very low delta(18)O values (<-3.5 parts per thousand) throughout the Trabakua and Ermua sections reflect diagenetic alteration rather than paleotemperatures. Because of deep burial diagenesis and very poorly preserved microfossils, the Trabakua Pass and Ermua sections are not optimal potential stratotypes for the Paleocene-Eocene boundary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aging process is associated with gradual and progressive loss of muscle mass along with lowered strength and physical endurance. This condition, sarcopenia, has been widely observed with aging in sedentary adults. Regular aerobic and resistance exercise programs have been shown to counteract most aspects of sarcopenia. In addition, good nutrition, especially adequate protein and energy intake, can help limit and treat age-related declines in muscle mass, strength, and functional abilities. Protein nutrition in combination with exercise is considered optimal for maintaining muscle function. With the goal of providing recommendations for health care professionals to help older adults sustain muscle strength and function into older age, the European Society for Clinical Nutrition and Metabolism (ESPEN) hosted a Workshop on Protein Requirements in the Elderly, held in Dubrovnik on November 24 and 25, 2013. Based on the evidence presented and discussed, the following recommendations are made (a) for healthy older people, the diet should provide at least 1.0-1.2 g protein/kg body weight/day, (b) for older people who are malnourished or at risk of malnutrition because they have acute or chronic illness, the diet should provide 1.2-1.5 g protein/kg body weight/day, with even higher intake for individuals with severe illness or injury, and (c) daily physical activity or exercise (resistance training, aerobic exercise) should be undertaken by all older people, for as long as possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Intraoperative EMG based neurophysiological monitoring is increasingly used to assist pedicle screw insertion. We carried out a study comparing the final screw position in the pedicle measured on CT images in relation to its corresponding intraoperative muscle compound action potential (CMAP) values. Material and methods: A total of 189 screws were inserted in thoracolumbar spines of 31 patients during instrumented fusion under EMG control. An observer, blinded to the CMAP value, assessed the horizontal and vertical 'screw edge to pedicle edge' distance perpendicular to the longitudinal axis of the screw on reformatted CT reconstructions using OsiriX software. These distances were analysed with their corresponding CMAP values. Data from 62 thoracic and 127 lumbar screws were processed separately. Interobserver reliability of distance measurements was assessed. Results: No patient suffered neurological injury secondary to screw insertion. Distance measurements were reliable (paired t-test, P = 0.13/0.98 horizontal/vertical). Two screws had their position altered due to low CMAP values suggesting close proximity of nerve tissue. Seventy five percent of screws had CMAP results above 10mA and had an average distance of 0.35cm (SD 0.23) horizontally and 0.46cm (SD 0.26) vertically from the pedicle edge. Additional 12% had a distance from the edge of the pedicle less than 0mm indicating cortical breach but had CMAP values above 10mA. A poor correlation between CMAP values and screw position was found. Discussion: In this study CMAP values above 10mA indicated correct screw position in the majority of cases. The zone of 10-20mA CMAP carries highest risk of a misplaced screw despite high CMAP value (17% of screws this CMAP range). In order to improve accuracy of EMG predictive value further research is warranted including improvement of probing techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare three spin-echo sequences, transverse T1-weighted (T1WI), transverse fat-saturated (FS) T2-weighted (T2WI), and transverse gadolinium-enhanced (Gd) FS T1WI, for the visualisation of normal and abnormal finger A2 pulley with magnetic resonance (MR) imaging at 3 tesla (T). MATERIALS AND METHODS: Sixty-three fingers from 21 patients were consecutively investigated. Two musculoskeletal radiologists retrospectively compared all sequences to assess the visibility of normal and abnormal A2 pulleys and the presence of motion or ghost artefacts. RESULTS: Normal and abnormal A2 pulleys were visible in 94% (59/63) and 95% (60/63) on T1WI sequences, in 63% (40/63) and 60% (38/63) on FS T2WI sequences, and in 87% (55/63) and 73% (46/63) on Gd FS T1WI sequences when read by the first and second observer, respectively. Motion and ghost artefacts were higher on FS T2WI sequences. Seven among eight abnormal A2 pulleys were detected, and were best depicted with Gd FS T1WI sequences in 71% (5/7) and 86% (6/7) by the first and the second observer, respectively. CONCLUSION: In 3-T MRI, the comparison between transverse T1WI, FS T2WI, and Gd FS T1WI sequences shows that transverse T1WI allows excellent depiction of the A2 pulley, that FS T2WI suffers from a higher rate of motion and ghost artefacts, and transverse Gd FS T1WI is the best sequence for the depiction of abnormal A2 pulley.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Lesion detection in multiple sclerosis (MS) is an essential part of its clinical diagnosis. In addition, radiological characterisation of MS lesions is an important research field that aims at distinguishing different MS types, monitoring drug response and prognosis. To date, various MR protocols have been proposed to obtain optimal lesion contrast for early and comprehensive diagnosis of the MS disease. In this study, we compare the sensitivity of five different MR contrasts for lesion detection: (i) the DIR sequence (Double Inversion Recovery, [4]), (ii) the Dark-fluid SPACE acquisition schemes, a 3D variant of a 2D FLAIR sequence [1], (iii) the MP2RAGE [2], an MP-RAGE variant that provides homogeneous T1 contrast and quantitative T1-values, and the sequences currently used for clinical MS diagnosis (2D FLAIR, MP-RAGE). Furthermore, we investigate the T1 relaxation times of cortical and sub-cortical regions in the brain hemispheres and the cerebellum at 3T. Methods 10 early-stage female MS patients (age: 31.64.7y; disease duration: 3.81.9y; disability score, EDSS: 1.80.4) and 10 healthy controls (age and gender-matched: 31.25.8y) were included in the study after obtaining informed written consent according to the local ethic protocol. All experiments were performed at 3T (Magnetom Trio a Tim System, Siemens, Germany) using a 32-channel head coil [5]. The imaging protocol included the following sequences, (all except for axial FLAIR 2D with 1x1x1.2 mm3 voxel and 256x256x160 matrix): DIR (TI1/TI2/TR XX/3652/10000 ms, iPAT=2, TA 12:02 min), MP-RAGE (TI/TR 900/2300 ms, iPAT=3, TA 3:47 min); MP2RAGE (TI1/TI2/TR 700/2500/5000 ms, iPAT=3, TA 8:22 min, cf. [2]); 3D FLAIR SPACE (only for patient 4-6, TI/TR 1800/5000 ms, iPAT=2, TA=5;52 min, cf. [1]); Axial FLAIR (0.9x0.9x2.5 mm3, 256x256x44 matrix, TI/TR 2500/9000 ms, iPAT=2, TA 4:05 min). Lesions were identified by two experienced neurologist and radiologist, manually contoured and assigned to regional locations (s. table 1). Regional lesion masks (RLM) from each contrast were compared for number and volumes of lesions. In addition, RLM were merged in a single "master" mask, which represented the sum of the lesions of all contrasts. T1 values were derived for each location from this mask for patients 5-10 (3D FLAIR contrast was missing for patient 1-4). Results & Discussion The DIR sequence appears the most sensitive for total lesions count, followed by the MP2RAGE (table 1). The 3D FLAIR SPACE sequence turns out to be more sensitive than the 2D FLAIR, presumably due to reduced partial volume effects. Looking for sub-cortical hemispheric lesions, the DIR contrast appears to be equally sensitive to the MP2RAGE and SPACE, but most sensitive for cerebellar MS plaques. The DIR sequence is also the one that reveals cortical hemispheric lesions best. T1 relaxation times at 3T in the WM and GM of the hemispheres and the cerebellum, as obtained with the MP2RAGE sequence, are shown in table 2. Extending previous studies, we confirm overall longer T1-values in lesion tissue and higher standard deviations compared to the non-lesion tissue and control tissue in healthy controls. We hypothesize a biological (different degree of axonal loss and demyelination) rather than technical origin. Conclusion In this study, we applied 5 MR contrasts including two novel sequences to investigate the contrast of highest sensitivity for early MS diagnosis. In addition, we characterized for the first time the T1 relaxation time in cortical and sub-cortical regions of the hemispheres and the cerebellum. Results are in agreement with previous publications and meaningful biological interpretation of the data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research aims toward a better understanding of the organizational culture(s) of the judiciary in Switzerland by analysing what 'good justice' means nowadays in this country. It seeks to clarify whether, and to what extent, expectations of 'good justice' of judicial actors (judges without managerial experience) and of managerial actors (court managers) are similar and to describe possible managerial implications that may result from this. As judges are at the heart of the judicial organization and exert a strong influence on other groups of actors (Sullivan, Warren et al. 1994), the congruence of their expectations with those of court managers will be at the centre of the analysis. Additionally, referring to the conceptual worlds of Boltanski and Thévenaut (1991), we analyze how closely these expectations are to management-oriented values. We found that almost half of expectations are common to the two groups examined and the main quoted ones are compatible to new public management (NPM) concepts. On the other hand, those expectations shared exclusively by judges relate to the human side of justice, whereas those specific to court managers focus on the way justice functions.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.