58 resultados para NSM FRP CFRP continuous quality control monitoring bond EMM-ARM
Resumo:
A simple and sensitive liquid chromatography-electrospray ionization mass spectrometry method was developed for the simultaneous quantification in human plasma of all selective serotonin reuptake inhibitors (citalopram, fluoxetine, fluvoxamine, paroxetine and sertraline) and their main active metabolites (desmethyl-citalopram and norfluoxetine). A stable isotope-labeled internal standard was used for each analyte to compensate for the global method variability, including extraction and ionization variations. After sample (250μl) pre-treatment with acetonitrile (500μl) to precipitate proteins, a fast solid-phase extraction procedure was performed using mixed mode Oasis MCX 96-well plate. Chromatographic separation was achieved in less than 9.0min on a XBridge C18 column (2.1×100mm; 3.5μm) using a gradient of ammonium acetate (pH 8.1; 50mM) and acetonitrile as mobile phase at a flow rate of 0.3ml/min. The method was fully validated according to Société Française des Sciences et Techniques Pharmaceutiques protocols and the latest Food and Drug Administration guidelines. Six point calibration curves were used to cover a large concentration range of 1-500ng/ml for citalopram, desmethyl-citalopram, paroxetine and sertraline, 1-1000ng/ml for fluoxetine and fluvoxamine, and 2-1000ng/ml for norfluoxetine. Good quantitative performances were achieved in terms of trueness (84.2-109.6%), repeatability (0.9-14.6%) and intermediate precision (1.8-18.0%) in the entire assay range including the lower limit of quantification. Internal standard-normalized matrix effects were lower than 13%. The accuracy profiles (total error) were mainly included in the acceptance limits of ±30% for biological samples. The method was successfully applied for routine therapeutic drug monitoring of more than 1600 patient plasma samples over 9 months. The β-expectation tolerance intervals determined during the validation phase were coherent with the results of quality control samples analyzed during routine use. This method is therefore precise and suitable both for therapeutic drug monitoring and pharmacokinetic studies in most clinical laboratories.
Resumo:
BACKGROUND: Six pioneer physicians-pharmacists quality circles (PPQCs) located in the Swiss canton of Fribourg (administratively corresponding to a state in the US) were under the responsibility of 6 trained community pharmacists moderating the prescribing process of 24 general practitioners (GPs). PPQCs are based on a multifaceted collaborative process mediated by community pharmacists for improving compliance with clinical guidelines within GPs' prescribing practices. OBJECTIVE: To assess, over a 9-year period (1999-2007), the cost-containment impact of the PPQCs. METHODS: The key elements of PPQCs are a structured continuous quality improvement and education process; local networking; feedback of comparative and detailed data regarding costs, drug choice, and frequency of prescribed drugs; and structured independent literature review for interdisciplinary continuing education. The data are issued from the community pharmacy invoices to the health insurance companies. The study analyzed the cost-containment impact of the PPQCs in comparison with GPs working in similar conditions of care without particular collaboration with pharmacists, the percentage of generic prescriptions for specific cardiovascular drug classes, and the percentage of drug costs or units prescribed for specific cardiovascular drugs. RESULTS: For the 9-year period, there was a 42% decrease in the drug costs in the PPQC group as compared to the control group, representing a $225,000 (USD) savings per GP only in 2007. These results are explained by better compliance with clinical and pharmacovigilance guidelines, larger distribution of generic drugs, a more balanced attitude toward marketing strategies, and interdisciplinary continuing education on the rational use of drugs. CONCLUSIONS: The PPQC work process has yielded sustainable results, such as significant cost savings, higher penetration of generics and reflection on patient safety, and the place of "new" drugs in therapy. The PPQCs may also constitute a solid basis for implementing more comprehensive collaborative programs, such as medication reviews, adherence-enhancing interventions, or disease management approaches.
Resumo:
Human biomonitoring (HBM) is an effective tool for assessing actual exposure to chemicals that takes into account all routes of intake. Although hair analysis is considered to be an optimal biomarker for assessing mercury exposure, the lack of harmonization as regards sampling and analytical procedures has often limited the comparison of data at national and international level. The European-funded projects COPHES and DEMOCOPHES developed and tested a harmonized European approach to Human Biomonitoring in response to the European Environment and Health Action Plan. Herein we describe the quality assurance program (QAP) for assessing mercury levels in hair samples from more than 1800 mother-child pairs recruited in 17 European countries. To ensure the comparability of the results, standard operating procedures (SOPs) for sampling and for mercury analysis were drafted and distributed to participating laboratories. Training sessions were organized for field workers and four external quality-assessment exercises (ICI/EQUAS), followed by the corresponding web conferences, were organized between March 2011 and February 2012. ICI/EQUAS used native hair samples at two mercury concentration ranges (0.20-0.71 and 0.80-1.63) per exercise. The results revealed relative standard deviations of 7.87-13.55% and 4.04-11.31% for the low and high mercury concentration ranges, respectively. A total of 16 out of 18 participating laboratories the QAP requirements and were allowed to analyze samples from the DEMOCOPHES pilot study. Web conferences after each ICI/EQUAS revealed this to be a new and effective tool for improving analytical performance and increasing capacity building. The procedure developed and tested in COPHES/DEMOCOPHES would be optimal for application on a global scale as regards implementation of the Minamata Convention on Mercury.
Resumo:
Type 2 diabetes mellitus (T2DM) is a major disease affecting nearly 280 million people worldwide. Whilst the pathophysiological mechanisms leading to disease are poorly understood, dysfunction of the insulin-producing pancreatic beta-cells is key event for disease development. Monitoring the gene expression profiles of pancreatic beta-cells under several genetic or chemical perturbations has shed light on genes and pathways involved in T2DM. The EuroDia database has been established to build a unique collection of gene expression measurements performed on beta-cells of three organisms, namely human, mouse and rat. The Gene Expression Data Analysis Interface (GEDAI) has been developed to support this database. The quality of each dataset is assessed by a series of quality control procedures to detect putative hybridization outliers. The system integrates a web interface to several standard analysis functions from R/Bioconductor to identify differentially expressed genes and pathways. It also allows the combination of multiple experiments performed on different array platforms of the same technology. The design of this system enables each user to rapidly design a custom analysis pipeline and thus produce their own list of genes and pathways. Raw and normalized data can be downloaded for each experiment. The flexible engine of this database (GEDAI) is currently used to handle gene expression data from several laboratory-run projects dealing with different organisms and platforms. Database URL: http://eurodia.vital-it.ch.
Resumo:
Images obtained from high-throughput mass spectrometry (MS) contain information that remains hidden when looking at a single spectrum at a time. Image processing of liquid chromatography-MS datasets can be extremely useful for quality control, experimental monitoring and knowledge extraction. The importance of imaging in differential analysis of proteomic experiments has already been established through two-dimensional gels and can now be foreseen with MS images. We present MSight, a new software designed to construct and manipulate MS images, as well as to facilitate their analysis and comparison.
Resumo:
Introduction: Electroconvulsive therapy (ECT) may be used to treat severe depression and needs a specific general anaesthesia. Important cardiovascular changes occur during the ECT with a parasympathetic induced bradycardia followed by a sympathetic response. A dedicated protocol was designed 6 years ago. The goal of this study was to analyse the management of anaesthesia for ECT in our institution, the adherence to the protocol and the occurrence of adverse events during anaesthesia. Methods: After Institutional Ethics Committee approval, we conducted a retrospective analysis of our anaesthesia protocol for patients scheduled for electroshock therapy during a five years period (2004- 2008). The protocol includes administration of atropine subcutaneously 30 minutes before the procedure, followed by general anaesthesia induced with etomidate (0.2 mg/kg). Suxamethonium (1 mg/kg) is administered after the inflation of a pneumatic tourniquet on the opposite arm, in order to observe the electroshocks convulsive effects. The psychiatrist initiates the convulsive crisis once curarisation is achieved. Face mask ventilation is then applied during the post-ictal phase with closed blood pressure monitoring. : 228 ECT were performed in 25 patients. The median dosage of etomidate was 0.37 mg/kg and suxamethonium 1.20 mg/kg. Hypertension during the ECT procedure was present in 62.7% of cases, tachycardia 23.2% and bradycardia 10.5%. Esmolol was administered in 73.4% of hypertensive patients in a range of 0 to 30 mg. The protocol was followed in half of the cases in regards to atropine administration (50.4%). We observed a significant increase of hypertension (73.9%, p = 0.001) after atropine administration, without effect on heart rate. Conclusions: The management of anaesthesia for ECT is specific and follows a predefined protocol in our institution. Adherence to our protocol was poor. Adverse events are frequent and significant association between the administration of atropine and the incidence of hypertension as well as poor protocol adherence implies reconsideration of our anaesthesia protocol for electroconvulsive therapy and better quality control of the clinical practice.
Resumo:
The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.
Resumo:
Swiss laboratories performing toxicological road traffic analyses have been authorized for many years by the Swiss Federal Roads Office (FEDRO). In 2003 FEDRO signed a contract with the Swiss Society of Legal Medicine (SSLM) to organize the complete quality management concerning road traffic analyses. For this purpose a multidisciplinary working group was established under the name of "road traffic commission (RTC)". RTC has to organize external quality control, to interpret the results of these controls, to perform audits in the laboratories and to report all results to FEDRO. Furthermore the working group can be mandated for special tasks by FEDRO. As an independent organization the Swiss Center for Quality Control (CSCQ) in Geneva manages the external quality controls in the laboratory over the past years. All tested drugs and psychoactive substances are listed in a federal instruction. The so-called 'zero tolerance substances' (THC, morphine, cocaine, amphetamine, methamphetamine, MDMA and MDEA) and their metabolites have to be tested once a year, all other substances (benzodiazepines, zolpidem, phenobarbital, etc.) periodically. Results over the last years show that all laboratories are generally within the confidence interval of +/-30% of the mean value. In cases of non-conformities measures have to be taken immediately and reported to the working group. External audits are performed triennially but accredited laboratories can combine this audit with the approval of the Swiss Accreditation Service (SAS). During the audits a special checklist filled in by the laboratory director is assessed. Non-conformities have to be corrected. During the process of establishing a new legislation, RTC had an opportunity of advising FEDRO. In collaboration with FEDRO, RTC and hence SSLM can work actively on improving of quality assurance in road traffic toxicological analyses, and has an opportunity to bring its professional requests to the federal authorities.
Resumo:
Quality assurance programmes are becoming a common practice in the field of mammography. At the present time several recommendations exist and different test objects are used to optimize this radiological procedure. The goal of this study was to check if geographically distant centres using different quality control procedures were comparable when using a common objective way of assessing image quality. The results show that consensus still needs to be found among radiologists to reach a satisfactory level of harmony between patient doses and image quality in Europe.
Resumo:
The comparative analysis of air quality control policies provides an interesting field for studies of comparative policy analysis including program formulation and implementation processes. In European countries, the problem is comparable, whereas implementation structures, programs and policy impacts vary to a considerable extent. Analysis testing possibilities and constraints of air control policies under varying conditions are likely to contribute to a further development of a theory of policy analysis. This paper presents the analytical framework applied in a continuing empirical study explaining program formulation and implementation processes with respect to the different actors involved. Concrete emitter behavior can be explained by interaction processes at the very local level, by program elements of national legislation, and by structural constraints under which such programs are produced.
Resumo:
Quality control (QuaCo) in urology is mandatory to standardize or even increase the level of care. While QuaCo is undertaken at every step in the clinical pathway, it should focus on the patient's comorbidities and on the urologist and its complication rate. Resulting from political and economical pressures, comparing QuaCo and outcomes between urologists and institutions is nowadays often performed. However, careful interpretation of these comparisons is mandatory to avoid potential discriminations. Indeed, the reader has to make sure that patients groups and surgical techniques are comparable, definitions of complications are similar, classification of complications is standardized, and finally that the methodology in collecting data is irreproachable.
Resumo:
Background and objective: Patients in the ICU often get many intravenous (iv) drugs at the same time. Even with three-lumen central venous catheters, the administration of more than one drug in the same iv line (IVL) is frequently necessary. The objective of this study was to observe how nurses managed to administer these many medications and to evaluate the proportion of two-drugs associations (TDA) that are compatible or not, based on known compatibility data. Design: Observational prospective study over 4 consecutive months. All patients receiving simultaneously more than one drugs in the same IVL (Y-site injection or mixed in the same container) were included. For each patient, all iv drugs were recorded, as well as concentration, infusion solution, location on the IVL system, time, rate and duration of administration. For each association of two or more drugs, compatibility of each drug was checked with each other. Compatibilities between these pairs of drugs were assessed using published data (mainly Trissel LA. Handbook on Injectable Drugs and Trissel's Tables of Physical Compatibility) and visual tests performed in our quality control laboratory. Setting: 34 beds university hospital adult ICU. Main outcome measures: Percentage of compatibilities and incompatibilities between drugs administered in the same IVL. Results: We observed 1,913 associations of drugs administered together in the same IVL, 783 implying only two drugs. The average number of drugs per IVL was 3.1 ± 0.8 (range: 2-9). 83.2% of the drugs were given by continuous infusion, 14.3% by intermittent infusion and 2.5% in bolus. The associations observed allowed to form 8,421 pairs of drugs (71.7% drug-drug and 28.3% drug-solute). According to literature data, 80.2% of the association were considered as compatible and 4.4% incompatible. 15.4% were not interpretable because of different conditions between local practices and those described in the literature (drug concentration, solute, etc.) or because of a lack of data. After laboratory tests performed on the most used drugs (furosemide, KH2PO4, morphine HCl, etc.), the proportion of compatible TDA raised to 85.7%, the incompatible stayed at 4.6% and only 9.7% remain unknown or not interpretable. Conclusions: Nurses managed the administration of iv medications quite well, as only less than 5% of observed TDA were considered as incompatible. But the 10% of TDA with unavailable compatibility data should have been avoided too, since the consequences of their concomitant administration cannot be predictable. For practical reasons, drugs were analysed only by pairs, which constitutes the main limit of this work. The average number of drugs in the same association being three, laboratory tests are currently performed to evaluate some of the most observed three-drugs associations.