74 resultados para Mobile Robot Navigation
Resumo:
PURPOSE: Respiratory motion correction remains a challenge in coronary magnetic resonance imaging (MRI) and current techniques, such as navigator gating, suffer from sub-optimal scan efficiency and ease-of-use. To overcome these limitations, an image-based self-navigation technique is proposed that uses "sub-images" and compressed sensing (CS) to obtain translational motion correction in 2D. The method was preliminarily implemented as a 2D technique and tested for feasibility for targeted coronary imaging. METHODS: During a 2D segmented radial k-space data acquisition, heavily undersampled sub-images were reconstructed from the readouts collected during each cardiac cycle. These sub-images may then be used for respiratory self-navigation. Alternatively, a CS reconstruction may be used to create these sub-images, so as to partially compensate for the heavy undersampling. Both approaches were quantitatively assessed using simulations and in vivo studies, and the resulting self-navigation strategies were then compared to conventional navigator gating. RESULTS: Sub-images reconstructed using CS showed a lower artifact level than sub-images reconstructed without CS. As a result, the final image quality was significantly better when using CS-assisted self-navigation as opposed to the non-CS approach. Moreover, while both self-navigation techniques led to a 69% scan time reduction (as compared to navigator gating), there was no significant difference in image quality between the CS-assisted self-navigation technique and conventional navigator gating, despite the significant decrease in scan time. CONCLUSIONS: CS-assisted self-navigation using 2D translational motion correction demonstrated feasibility of producing coronary MRA data with image quality comparable to that obtained with conventional navigator gating, and does so without the use of additional acquisitions or motion modeling, while still allowing for 100% scan efficiency and an improved ease-of-use. In conclusion, compressed sensing may become a critical adjunct for 2D translational motion correction in free-breathing cardiac imaging with high spatial resolution. An expansion to modern 3D approaches is now warranted.
Resumo:
OBJECTIVE: The occurrence of the 2003 G8 summit in Evian and the threat of major civil riots or even terrorist attacks in the Swiss neighbourhood forced us to imagine a new system of rescue and medical care in case of numerous victims. Previous occurrences of the G8 in Europe or America have demonstrated the need of flexible and mobile structures, able to respond quickly to crowd movements, unlike the usual static structure of rescue systems designed for major accidents. METHODS: We developed a new concept of Mobile Medical Squadrons (MMS) consisting of several vehicles and medical care and rescue human resources. In our concept, each MMS consisted of 3 emergency doctors, 5 paramedics and 9 first-aid workers. They were designed to handle 15 patients, with a large autonomy in terms of rescue, medical care, evacuation and medical authority. The equipment included medical, resuscitation, simple decontamination, evacuation and communication materials. RESULTS: The MMS were dispatched four times during the G8 summit following civil riots. They took care of 12 injured patients. CONCLUSION: The concept of MMS as a reinforcement of the existing rescue and health care resources appears as a new flexible, a modular and useful concept for the medical management of collective prehospital emergency situations. Its use is suggested instead of the traditional static concept of rescue systems designed for major accidents.
Resumo:
Un protocole de tests sur labyrinthe radial permettant d'évaluer la navigation spatial chez l'homme a été réalisé. Ces tests sur labyrinthe radial sont basés sur le protocole utilisé sur l'animal modèle de schizophrénie dans le CNP (Centre de neuroscience psychiatrique) de Lausanne. Les recherches actuelles du CNP ont montré un déficit dans les capacités d'orientation spatiale de ces animaux [13]. Ainsi notre méthodologie consistera à tester des sujets humains dans des tâches de labyrinthe afin d'étudier de la manière la plus équivalente les différents déficits observés dans la pathologie humaine et dans le rat modèle. Cette démarche est à la base d'une approche translationnelle qui combine recherches cliniques et expérimentales. Le travail expérimental a été mené sur deux dispositifs analogues. a) «radial au doigt», ensemble de petits canaux qui peuvent être explorés par le doigt, yeux ouverts ou fermés et dans lesquels des textures différentes tapissent chaque bras. b) «radial sur écran tactile», deux labyrinthes qui comparent deux types d'indice locale, couleurs différentes ou patrons noir-blanc. Dans les deux dispositifs a été prévu une série de tests permettant d'évaluer la mémorisation des indices utilisés en les supprimant temporairement où en les mettant en contradiction. La première perturbation a pour but de tester l'importance du référentiel locale par une rotation de 90° du labyrinthe. La permutation des bras lors d'un dernier essai permet d'induire une situation ou les informations ont été soit correctes spatialement mais incorrectes localement (texture) soit inversement. Ces perturbations des informations sensorielles qui sont fournies au sujet, permettent d'observer les systèmes de repérage et leur poids relatif dans la construction d'un système de référence durant la navigation spatiale. Les résultats du labyrinthe radial au doigt montrent que dans les conditions utilisant les informations visuelles les participants sont sensiblement plus performants. Il est apparu que les informations visuelles prédominent sur les informations proprioceptives et tactiles. Ainsi dans la condition intégrant informations visuospatiales, proprioceptives et tactiles, les sujets basent plus fortement leur navigation spatiale sur les indices visuelles soit locale soit spatiale. Dans cette condition une différence significative de stratégie entre hommes et femmes est apparue. Les hommes se basent majoritairement sur des indices spatiaux tandis que les femmes préfèrent les indices locaux. En présence d'informations tactiles et proprioceptives mais en absence de la vision, les participants utilisent les références spatiale et locale complémentairement sans avoir un système prédominant. Alors que si uniquement les informations proprioceptives sont présentes, les sujets utilisent un système de référence spatiale (globale). Le labyrinthe radial sur écran tactile indique une différence de système de référence selon l'indice local employé. Les couleurs, étant des forts indices locaux, vont favoriser un système de référence local. Au contraire les patrons noirs-blancs sont des indices visiblement très complexes et difficiles à mémoriser qui vont pousser les sujets à utiliser une stratégie de référence spatiale.
Resumo:
Background: Integrative and conjugative elements (ICE) form a diverse group of DNA elements that are integrated in the chromosome of the bacterial host, but can occasionally excise and horizontally transfer to a new host cell. ICE come in different families, typically with a conserved core for functions controlling the element's behavior and a variable region providing auxiliary functions to the host. The ICEclc element of Pseudomonas knackmussii strain B13 is representative for a large family of chromosomal islands detected by genome sequencing approaches. It provides the host with the capacity to degrade chloroaromatics and 2-aminophenol. Results: Here we study the transcriptional organization of the ICEclc core region. By northern hybridizations, reverse-transcriptase polymerase chain reaction (RT-PCR) and Rapid Amplification of cDNA Ends (5'-RACE) fifteen transcripts were mapped in the core region. The occurrence and location of those transcripts were further confirmed by hybridizing labeled cDNA to a semi-tiling micro-array probing both strands of the ICEclc core region. Dot blot and semi-tiling array hybridizations demonstrated most of the core transcripts to be upregulated during stationary phase on 3-chlorobenzoate, but not on succinate or glucose. Conclusions: The transcription analysis of the ICEclc core region provides detailed insights in the mode of regulatory organization and will help to further understand the complex mode of behavior of this class of mobile elements. We conclude that ICEclc core transcription is concerted at a global level, more reminiscent of a phage program than of plasmid conjugation.
Resumo:
Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. This randomized controlled double-blind study included to date 14 patients: the gait signatures of four patients with mobile-bearing were compared to the gait signatures of nine patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.
Resumo:
BACKGROUND: There is a growing use of mobile devices to access the Internet. We examined whether participants who used a mobile device to access a brief online survey were quicker to respond to the survey but also, less likely to complete it than participants using a traditional web browser. FINDINGS: Using data from a recently completed online intervention trial, we found that participants using mobile devices were quicker to access the survey but less likely to complete it compared to participants using a traditional web browser. More concerning, mobile device users were also less likely to respond to a request to complete a six week follow-up survey compared to those using traditional web browsers. CONCLUSIONS: With roughly a third of participants using mobile devices to answer an online survey in this study, the impact of mobile device usage on survey completion rates is a concern. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01521078.
Resumo:
PURPOSE: Performing total knee replacement, accurate alignment and neutral rotation of the femoral component are widely believed to be crucial for the ultimate success. Contrary to absolute bone referenced alignment, using a ligament balancing technique does not automatically rotate the femoral component parallel to the transepicondylar axis. In this context we established the hypothesis that rotational alignment of the femoral component parallel to the transepicondylar axis (0° ± 3°) results in better outcome than alignment outside of this range. METHODS: We analysed 204 primary cemented mobile bearing total knee replacements five years postoperatively. Femoral component rotation was measured on axial radiographs using the condylar twist angle (CTA). Knee society score, range of motion as well as subjective rating documented outcome. RESULTS: In 96 knees the femoral component rotation was within the range 0 ± 3° (neutral rotation group), and in 108 knees the five-year postoperative rotational alignment of the femoral component was outside of this range (outlier group). Postoperative CTA showed a mean of 2.8° (±3.4°) internal rotation (IR) with a range between 6° external rotation (ER) and 15° IR (CI 95). No difference with regard to subjective and objective outcome could be detected. CONCLUSION: The present work shows that there is a large given natural variability in optimal rotational orientation, in this study between 6° ER and 15° IR, with numerous co-factors determining correct positioning of the femoral component. Further studies substantiating pre- and postoperative determinants are required to complete the understanding of resulting biomechanics in primary TKA.
Resumo:
En matière de dépistage du cancer du sein, il a été proposé de compléter les moyens techniques actuellement disponibles des praticiens du canton de Vaud par ceux d'une unité mobile de mammographie. Avant de se lancer dans cette aventure, il paraît raisonnable d'estimer le volume et la nature de la demande pour ce nouveau service. La participation des femmes vaudoises peut être évaluée par une enquête de population. Pour préparer cette enquête, un sondage téléphonique pilote a été effectué, permettant d'en estimer la faisabilité, le coût et le rendement.