46 resultados para Method validation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a new non parametric atlas registration framework, derived from the optical flow model and the active contour theory, applied to automatic subthalamic nucleus (STN) targeting in deep brain stimulation (DBS) surgery. In a previous work, we demonstrated that the STN position can be predicted based on the position of surrounding visible structures, namely the lateral and third ventricles. A STN targeting process can thus be obtained by registering these structures of interest between a brain atlas and the patient image. Here we aim to improve the results of the state of the art targeting methods and at the same time to reduce the computational time. Our simultaneous segmentation and registration model shows mean STN localization errors statistically similar to the most performing registration algorithms tested so far and to the targeting expert's variability. Moreover, the computational time of our registration method is much lower, which is a worthwhile improvement from a clinical point of view.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Ethyl glucuronide (EtG) is a minor and direct metabolite of ethanol. EtG is incorporated into the growing hair allowing retrospective investigation of chronic alcohol abuse. In this study, we report the development and the validation of a method using gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS) for the quantification of EtG in hair. EtG was extracted from about 30 mg of hair by aqueous incubation and purified by solid-phase extraction (SPE) using mixed mode extraction cartridges followed by derivation with perfluoropentanoic anhydride (PFPA). The analysis was performed in the selected reaction monitoring (SRM) mode using the transitions m/z 347-->163 (for the quantification) and m/z 347-->119 (for the identification) for EtG, and m/z 352-->163 for EtG-d(5) used as internal standard. For validation, we prepared quality controls (QC) using hair samples taken post mortem from 2 subjects with a known history of alcoholism. These samples were confirmed by a proficiency test with 7 participating laboratories. The assay linearity of EtG was confirmed over the range from 8.4 to 259.4 pg/mg hair, with a coefficient of determination (r(2)) above 0.999. The limit of detection (LOD) was estimated with 3.0 pg/mg. The lower limit of quantification (LLOQ) of the method was fixed at 8.4 pg/mg. Repeatability and intermediate precision (relative standard deviation, RSD%), tested at 4 QC levels, were less than 13.2%. The analytical method was applied to several hair samples obtained from autopsy cases with a history of alcoholism and/or lesions caused by alcohol. EtG concentrations in hair ranged from 60 to 820 pg/mg hair.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Propane can be responsible for several types of lethal intoxication and explosions. Quantifying it would be very helpful to determine in some cases the cause of death. Some gas chromatography-mass spectrometry (GC-MS) methods of propane measurements do already exist. The main drawback of these GC-MS methods described in the literature is the absence of a specific propane internal standard necessary for accurate quantitative analysis. The main outcome of the following study was to provide an innovative Headspace-GC-MS method (HS-GC-MS) applicable to the routine determination of propane concentration in forensic toxicology laboratories. To date, no stable isotope of propane is commercially available. The development of an in situ generation of standards is thus presented. An internal-labeled standard gas (C3DH7) is generated in situ by the stoichiometric formation of propane by the reaction of deuterated water (D2O) with Grignard reagent propylmagnesium chloride (C3H7MgCl). The method aims to use this internal standard to quantify propane concentrations and, therefore, to obtain precise measurements. Consequently, a complete validation with an accuracy profile according to two different guidelines, the French Society of Pharmaceutical Sciences and Techniques (SFSTP) and the Gesellschaft für toxikologische und Forensische Chemie (GTFCh), is presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of our study was to provide an innovative HS-GC/MS method applicable to the routine determination of butane concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature concerning butane measurement was the absence of a specific butane internal standard necessary to perform quantification. Because no stable isotope of butane is commercially available, it is essential to develop a new approach by an in situ generation of standards. To avoid the manipulation of a stable isotope-labelled gas, we have chosen to generate in situ an internal labelled standard gas (C(4)H(9)D) following the basis of the stoichiometric formation of butane by the reaction of deuterated water (D(2)O) with Grignard reagent butylmagnesium chloride (C(4)H(9)MgCl). This method allows a precise measurement of butane concentration and therefore, a full validation by accuracy profile was presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Following their detection and seizure by police and border guard authorities, false identity and travel documents are usually scanned, producing digital images. This research investigates the potential of these images to classify false identity documents, highlight links between documents produced by a same modus operandi or same source, and thus support forensic intelligence efforts. Inspired by previous research work about digital images of Ecstasy tablets, a systematic and complete method has been developed to acquire, collect, process and compare images of false identity documents. This first part of the article highlights the critical steps of the method and the development of a prototype that processes regions of interest extracted from images. Acquisition conditions have been fine-tuned in order to optimise reproducibility and comparability of images. Different filters and comparison metrics have been evaluated and the performance of the method has been assessed using two calibration and validation sets of documents, made up of 101 Italian driving licenses and 96 Portuguese passports seized in Switzerland, among which some were known to come from common sources. Results indicate that the use of Hue and Edge filters or their combination to extract profiles from images, and then the comparison of profiles with a Canberra distance-based metric provides the most accurate classification of documents. The method appears also to be quick, efficient and inexpensive. It can be easily operated from remote locations and shared amongst different organisations, which makes it very convenient for future operational applications. The method could serve as a first fast triage method that may help target more resource-intensive profiling methods (based on a visual, physical or chemical examination of documents for instance). Its contribution to forensic intelligence and its application to several sets of false identity documents seized by police and border guards will be developed in a forthcoming article (part II).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Adequate pain assessment is critical for evaluating the efficacy of analgesic treatment in clinical practice and during the development of new therapies. Yet the currently used scores of global pain intensity fail to reflect the diversity of pain manifestations and the complexity of underlying biological mechanisms. We have developed a tool for a standardized assessment of pain-related symptoms and signs that differentiates pain phenotypes independent of etiology. METHODS AND FINDINGS: Using a structured interview (16 questions) and a standardized bedside examination (23 tests), we prospectively assessed symptoms and signs in 130 patients with peripheral neuropathic pain caused by diabetic polyneuropathy, postherpetic neuralgia, or radicular low back pain (LBP), and in 57 patients with non-neuropathic (axial) LBP. A hierarchical cluster analysis revealed distinct association patterns of symptoms and signs (pain subtypes) that characterized six subgroups of patients with neuropathic pain and two subgroups of patients with non-neuropathic pain. Using a classification tree analysis, we identified the most discriminatory assessment items for the identification of pain subtypes. We combined these six interview questions and ten physical tests in a pain assessment tool that we named Standardized Evaluation of Pain (StEP). We validated StEP for the distinction between radicular and axial LBP in an independent group of 137 patients. StEP identified patients with radicular pain with high sensitivity (92%; 95% confidence interval [CI] 83%-97%) and specificity (97%; 95% CI 89%-100%). The diagnostic accuracy of StEP exceeded that of a dedicated screening tool for neuropathic pain and spinal magnetic resonance imaging. In addition, we were able to reproduce subtypes of radicular and axial LBP, underscoring the utility of StEP for discerning distinct constellations of symptoms and signs. CONCLUSIONS: We present a novel method of identifying pain subtypes that we believe reflect underlying pain mechanisms. We demonstrate that this new approach to pain assessment helps separate radicular from axial back pain. Beyond diagnostic utility, a standardized differentiation of pain subtypes that is independent of disease etiology may offer a unique opportunity to improve targeted analgesic treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To further validate the doubly labeled water method for measurement of CO2 production and energy expenditure in humans, we compared it with near-continuous respiratory gas exchange in nine healthy young adult males. Subjects were housed in a respiratory chamber for 4 days. Each received 2H2(18)O at either a low (n = 6) or a moderate (n = 3) isotope dose. Low and moderate doses produced initial 2H enrichments of 5 and 10 X 10(-3) atom percent excess, respectively, and initial 18O enrichments of 2 and 2.5 X 10(-2) atom percent excess, respectively. Total body water was calculated from isotope dilution in saliva collected at 4 and 5 h after the dose. CO2 production was calculated by the two-point method using the isotopic enrichments of urines collected just before each subject entered and left the chamber. Isotope enrichments relative to predose samples were measured by isotope ratio mass spectrometry. At low isotope dose, doubly labeled water overestimated average daily energy expenditure by 8 +/- 9% (SD) (range -7 to 22%). At moderate dose the difference was reduced to +4 +/- 5% (range 0-9%). The isotope elimination curves for 2H and 18O from serial urines collected from one of the subjects showed expected diurnal variations but were otherwise quite smooth. The overestimate may be due to approximations in the corrections for isotope fractionation and isotope dilution. An alternative approach to the corrections is presented that reduces the overestimate to 1%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L'objectif de l'étude présentée est d'adapter et de valider une version française de la Stigma Scale (King, 2007) auprès d'une population de personnes souffrant de troubles psychiques. Dans une première phase, la stabilité temporelle (fidélité test-retest), la cohérence interne et la validité convergente de l'instrument original à 28 items traduit en français ont été évaluées auprès d'un échantillon de 183 patients. Les résultats d'analyses factorielles confirmatoires ne nous ont pas permis de confirmer la structure originale de l'instrument. Nous avons donc proposé, sur la base des résultats d'une analyse factorielle exploratoire, une version courte de l'échelle de stigmatisation (9 items) qui conserve la structure en trois facteurs du modèle original. Dans une deuxième phase, nous avons examiné les qualités psychométriques et validé cette version abrégée de l'échelle de stigmatisation auprès d'un second échantillon de 234 patients. Les indices d'ajustements de notre analyse factorielle confirmatoire confirme la structure en trois facteurs de la version abrégée de la Stigma Scale. Les résultats suggèrent que la version française abrégée de l'échelle de stigmatisation constitue un instrument utile, fiable et valide dans l'autoévaluation de la stigmatisation perçue par des personnes souffrant de troubles psychiques. - Aim People suffering from mental illness are exposed to stigma. However, only few tools are available to assess stigmatization as perceived from the patient's perspective. The aim of this study is to adapt and validate a French version of the Stigma Scale (King, 2007). This self-report questionnaire has a three-factor structure: discrimination, disclosure and positive aspects of mental illness. Discrimination subscale refers to perceived negative reactions by others. Disclosure subscale refers mainly to managing disclosure to avoid discrimination and finally positive aspects subscale taps into how patients are becoming more accepting, more understanding toward their illness. Method In the first step, internal consistency, convergent validity and test-retest reliability of the French adaptation of the 28-item scale have been assessed on a sample of 183 patients. Results of confirmatory factor analyses (CFA) did not confirm the hypothesized structure. In light of the failed attempts to validate the original version, an alternative 9-item short-form version of the Stigma Scale, maintaining the integrity of the original model, was developed based on results of exploratory factor analyses in the first sample and cross- validated in a new sample of 234 patients. Results Results of CFA did not confirm that the data fitted well to the three-factor model of the 28-item Stigma Scale (χ2/άί=2.02, GFI=0.77, AGFI=0.73, RMSEA=0.07, CFI=0.77 et NNFI=0.75). Cronbach's α are excellent for discrimination (0.84) and disclosure (0.83) subscales but poor for potential positive aspects (0.46). External validity is satisfactory. Overall Stigma Scale total score is negatively correlated with score on Rosenberg's Self-Esteem Scale (r = -0.49), and each sub-scale is significantly correlated with a visual analogue scale that refers to the specific aspect of stigma (0.43 < |r| < 0.60). Intraclass correlation coefficients between 0.68 and 0.89 indicate good test- retest reliability. Results of CFA demonstrate that the items chosen for the short version of the Stigma Scale have the expected fit properties fa2/df=1.02, GFI=0.98, AGFI=0.98, RMSEA=0.01, CFI=1.0 et NNFI=1.0). Considering the small number (3 items) of items in each subscales of the short version of the Stigma Scale, a coefficients for the discrimination (0.57), disclosure (0.80) and potential positive aspects subscales (0.62) are considered as good. Conclusion Our results suggest that the 9-item French short-version of the Stigma Scale is a useful, reliable and valid self-report questionnaire to assess perceived stigmatization in people suffering from mental illness. The time of completion is really short and questions are well understood and accepted by the patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Hepcidin, a 25 amino acid peptide, plays an important role in iron homeostasis. Some hepcidin truncated peptides have antibiotic effects. RESULTS: A new analytical method for hepcidin determination in human plasma using LC-HRMS operating in full-scan acquisition mode has been validated. The extraction consists of protein precipitation and a drying reconstitution step; a 2.1 x 50 mm (idxL) C18 analytical column was used. Detection specificity, stability, accuracy, precision and recoveries were determined. The LOQ/LOD were 0.25/0.1 nM, respectively. More than 600 injections of plasma extracts were performed, allowing evaluation of the assay robustness. Hepcidin-20, hepcidin-22 and a new isoform, hepcidin-24, were detected in patients. CONCLUSION: The data underscore the usefulness of LC-HRMS for in-depth investigations related to hepcidin levels and pathways.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Major depression, although frequent in primary care, is commonly hidden behind multiple physical complaints that are often the first and only reason for patient consultation. Major depression can be screened by two validated questions that are easier to use in primary care than the full DSM-IV criteria. A third question, called the "help" question, improves the specificity without apparently decreasing the sensitivity of this screening procedure. We validated the abbreviated screening procedure for major depression with and without the "help" question in primary care patients managed for a physical complaint. METHODS: This diagnostic accuracy study used data from a cohort study called SODA (for SOmatisation Depression Anxiety ) conducted by 24 general practitioners (GPs) in western Switzerland that included patients over 18 years of age with at least one physical complaint at index consultation. Major depression was identified with the full Patient Health Questionnaire. GPs were asked to screen patients for major depression with the three screening questions one year after inclusion. RESULTS: Out of 937 patients with at least one physical complaint, 751 were eligible one year after index consultation. Major depression was diagnosed in 69/724 (9.5%) patients. The sensitivity and specificity of the two-question method alone were 91.3% (95% confidence interval 81.4-96.4%) and 65.0% (95% confidence interval 61.2-68.6%), respectively. Adding the "help" question decreased the sensitivity (59.4% ; 95% confidence interval 47.0-70.9%) but improved the specificity (88.2% ; 95% confidence interval 85.4-90.5%) of the three-question method. CONCLUSIONS: The use of two screening questions for major depression was associated with high sensitivity and low specificity in primary care patients presenting a physical complaint. Adding the "help" question improved the specificity but clearly decreased the sensitivity; when using the "help" question; four out of ten patients with depression will be missed, compared to only one out of ten with the two-question method. Therefore, the "help" question is not useful as a screening question, but may help discussing management strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Anterior shoulder stabilization surgery with the arthroscopic Bankart procedure can have a high recurrence rate in certain patients. Identifying these patients to modify outcomes has become a focal point of research. PURPOSE: The Instability Shoulder Index Score (ISIS) was developed to predict the success of arthroscopic Bankart repair. Scores range from 0 to 10, with higher scores predicting a higher risk of recurrence after stabilization. The interobserver reliability of the score is not known. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: This is a prospective multicenter (North America and Europe) study of patients suffering from shoulder instability and waiting for stabilization surgery. Five pairs of independent evaluators were asked to score patient instability severity with the ISIS. Patients also completed functional scores (Western Ontario Shoulder Instability Index [WOSI], Disabilities of the Arm, Shoulder and Hand-short version [QuickDASH], and Walch-Duplay test). Data on age, sex, number of dislocations, and type of surgery were collected. The test-retest method and intraclass correlation coefficient (ICC: >0.75 = good, >0.85 = very good, and >0.9 = excellent) were used for analysis. RESULTS: A total of 114 patients with anterior shoulder instability were included, of whom 89 (78%) were men. The mean age was 28 years. The ISIS was very reliable, with an ICC of 0.933. The mean number of dislocations per patient was higher in patients who had an ISIS of ≥6 (25 vs 14; P = .05). Patients who underwent more complex arthroscopic procedures such as Hill-Sachs remplissage or open Latarjet had higher preoperative ISIS outcomes, with a mean score of 4.8 versus 3.4, respectively (P = .002). There was no correlation between the ISIS and the quality-of-life questionnaires, with Pearson correlations all >0.05 (WOSI = 0.39; QuickDASH = 0.97; Walch-Duplay = 0.08). CONCLUSION: Our results show that the ISIS is reliable when used in a multicenter study with anterior traumatic instability populations. There was no correlation between the ISIS and the quality-of-life questionnaires, but surgical decisions reflected its increased use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The psychobiological seven-factor model proposed by Cloninger et al. (1993) takes into account temperament and character dimensions to describe personality. Four of the dimensions are linked with biological, genetic and neuroanatomic structures, whereas the three other dimensions are related to the degree of individual, social and spiritual development. A study conducted by Wills et al. (1994) with adolescents showed that substance abuse was associated with high scores on Novelty Seeking and low scores on Harm Avoidance and Reward Dependence. The aim of the present study was, firstly, to create a short form of Cloninger's (1993) Temperament and Character Inventory (TCI) and, secondly, to study the impact of nicotine dependence as well as demographic variables on a sample of young adults. Method: We created a short form of the TCI containing 56 items (TCI-56), 8 for each scale. Responses are made on a five-point Likert type scale. A Swiss sample (n=211), of 116 women and 95 men, aged from 15 to 30 years, participated in this study. Our population was divided into a group of 81 smokers and another of 130 non-smokers, according to their scores on the Fagerstörm test for nicotine dependence (1999). Results: The structural validation consisted of two separate factor analysis with varimax rotations, one for the temperamental items, and the other, for the character ones. The first factor analysis conducted on the items of the temperament scales allowed to extract 4 factors explaining 40.7% of the variance. The correlations between factors and scales are the following: r=.71 for Novelty Seeking, r=.69 for Persistence, r=.95 for Harm Avoidance, r=.94 for Reward Dependence. The second factor analysis conducted on the items of the character scales allowed to extract 3 factors explaining 41.5% of the variance. The correlations between factors and scales are the following: r=.94 for Self-Directedness, r=.91 for Cooperativeness and r=.99 for Self-Transcendence. The internal consistencies range from α=.65 to α=.75 for the temperament scales, and from α=.71 to α=.83 for the three character scales. Concerning, the impact of the nicotine dependence, we observed that smokers have significantly higher scores for Novelty seeking, than non-smokers (p=.01). We found no difference for Harm Avoidance and Reward Dependence. Nevertheless, smokers seem to have the tendency to score higher on Transcendence (p=.06). Moreover, people having smoked more than 100 cigarettes in their life have significantly higher scores on this scale (p.04) and the correlation between Transcendence and the Fagerstörm test is significant (r=.19). We also found gender differences: the women (N=116) obtain significantly higher scores for Harm Avoidance (p<.001), for Reward Dependence (p<.001) and for Cooperation (p=.01). We further found a significant correlation between age and Self-Directedness, r=.34. We observed no interaction between gender and smoking or age and smoking on the dimensions of the TCI-56. Discussion: The TCI short form (TCI-56) seems to be a valid and useful inventory to assess personality differences. Confirming the results of others about the relation between addiction and personality, we found that smokers have significantly higher scores for Novelty seeking, than non-smokers. But we were not able to find any significant differences for Harm Avoidance and Reward Dependence. This might be due to our sample that was made of young adults. This study also shows that Transcendence could be an interesting dimension for studies on Tobacco smoking to consider. Concerning the impact of demographic variables, we observed that age and gender have specific and coherent influence on personality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Carbon isotope ratio of androgens in urine specimens is routinely determined to exclude an abuse of testosterone or testosterone prohormones by athletes. Increasing application of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) in the last years for target and systematic investigations on samples has resulted in the demand for rapid sample throughput as well as high selectivity in the extraction process particularly in the case of conspicuous samples. For that purpose, we present herein the complimentary use of an SPE-based assay and an HPLC fractionation method as a two-stage strategy for the isolation of testosterone metabolites and endogenous reference compounds prior to GC/C/IRMS analyses. Assays validation demonstrated acceptable performance in terms of intermediate precision (range: 0.1-0.4 per thousand) and Bland-Altman analyses revealed no significant bias (0.2 per thousand). For further validation of this two-stage analyses strategy, all the specimens (n=124) collected during a major sport event were processed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: The aim of this study was to interpret and validate a French version of the Oswestry disability index (ODI), using a cross-cultural validation method. The validity and reliability of the questionnaire was assessed in order to ensure the psychometric characteristics. METHOD: The cross-cultural validation was carried out according to Beaton's methodology. The study was conducted with 41 patients suffering from low back pain. The correlation between the ODI and the Roland-Morris disability questionnaire (RMDQ), the medical outcome survey short form-36 (MOS SF-36) and a pain visual analogical scale (VAS) was assessed. RESULTS: The validity of the Oswestry questionnaire was studied using the Cronbach Alpha coefficient calculation: 0.87 (n=36). The significant correlation between the ODI and RMDQ was 0.8 (P<0.001, n=41) and 0.71 (P<0.001, n=36) for the pain VAS. The correlation between the ODI and certain subscales (physical functioning 0.7 (P<0.001, n=41), physical role 0.49 et bodily pain 0.73 (P<0.001, n=41)) of the MOS SF-36 were equally significant. The reproducibility of the ODI was calculated using the Wilcoxon matched pairs test: there was no significant difference for eight out of ten sections or for the final score. CONCLUSION: This French translation of the ODI should be considered as valid and reliable. It should be used for any future clinical studies carried out using French language patients. Complimentary studies must be completed in order to assess its sensitivity to change in the event of any modifications in the patients functional capacity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Saffaj et al. recently criticized our method of monitoring carbon dioxide in human postmortem cardiac gas samples using Headspace-Gas Chromatography-Mass Spectrometry. According to the authors, their demonstration, based on the latest SFSTP guidelines (established after 2007 [1,2]) fitted for the validation of drug monitoring bioanalytical methods, has put in evidence potential errors. However, our validation approach was built using SFSTP guidelines established before 2007 [3-6]. We justify the use of these guidelines because of the post-mortem context of the study (and not clinical) and the gaseous state of the sample (and not solid or liquid). Using these guidelines, our validation remains correct.