303 resultados para MESENTERIC-ARTERIES
Resumo:
BACKGROUND: In late-diagnosed transposition of the great arteries (TGA), the left ventricle (LV) involutes as it pumps against low resistance and needs retraining by applying a pulmonary artery band (PAB) in preparation for an arterial switch operation. We report our experience with a telemetrically adaptable band compared with classic banding. METHODS: Ten patients underwent retraining of the LV, 4 patients with an adaptable band and progressive weekly tightening of the band (group 1) and 6 patients with a traditional band (group 2). RESULTS: Mean weight and age at pulmonary band placement was 5.8 ± 2.36 kg and 11.7 ± 11.1 months for group 1 and 5.0 ± 2.3 kg and 6.4 ± 7.6 months for group 2. Time between palliation and switch procedure was 4.2 months in both groups. Group 1 showed an initial mean pulmonary gradient of 25.5 ± 4.43 mm Hg with a 5% closure of the device. The mean gradient increased with progressive closure to 63.5 ± 9.8 mm Hg at the time of the arterial switch operation. There were no reinterventions or deaths in this group. In group 2, the mean pulmonary gradient increased with growth from 49 ± 21.4 mm Hg to 68.4 ± 7.86 mm Hg at the time of the switch procedure. However, 4 of these patients required reoperations during retraining: 2 needed 1 reoperation and 2 needed 2 reoperations. Two patients died-1 after banding and 1 after the switch operation. CONCLUSIONS: Retraining of the LV by the adaptable device allows precise control of the tightening, avoids repetitive operations, and diminishes morbidity.
Resumo:
Nitric oxide (NO) and monocyte chemoattractant protein-1 (MCP-1) exert partly opposing effects in vascular biology. NO plays pleiotropic vasoprotective roles including vasodilation and inhibition of platelet aggregation, smooth muscle cell proliferation, and endothelial monocyte adhesion, the last effect being mediated by MCP-1 downregulation. Early stages of arteriosclerosis are associated with reduced NO bioactivity and enhanced MCP-1 expression. We have evaluated adenovirus-mediated gene transfer of human endothelial NO synthase (eNOS) and of a N-terminal deletion (8ND) mutant of the MCP-1 gene that acts as a MCP-1 inhibitor in arteriosclerosis-prone, apolipoprotein E-deficient (ApoE(-/-)) mice. Endothelium-dependent relaxations were impaired in carotid arteries instilled with a noncoding adenoviral vector but were restored by eNOS gene transfer (p < 0.01). A perivascular collar was placed around the common carotid artery to accelerate lesion formation. eNOS gene transfer reduced lesion surface areas, intima/media ratios, and macrophage contents in the media at 5-week follow-up (p < 0.05). In contrast, 8ND-MCP-1 gene transfer did not prevent lesion formation. In conclusion, eNOS gene transfer restores endothelium-dependent vasodilation and inhibits lesion formation in ApoE(-/-) mouse carotids. Further studies are needed to assess whether vasoprotection is maintained at later disease stages and to evaluate the long-term efficacy of eNOS gene therapy for primary arteriosclerosis.
Resumo:
The present study was aimed at examining the role of nitric oxide (NO) in the hypoxic contraction of isolated small pulmonary arteries (SPA) in the rat. Animals were treated with either saline (sham experiments) or Escherichia coli lipolysaccharide [LPS, to obtain expression of the inducible NO synthase (iNOS) in the lung] and killed 4 h later. SPA (300- to 600-micrometer outer diameter) were mounted as rings in organ chambers for the recording of isometric tension, precontracted with PGF2alpha, and exposed to either severe (bath PO2 8 +/- 3 mmHg) or milder (21 +/- 3 mmHg) hypoxia. In SPA from sham-treated rats, contractions elicited by severe hypoxia were completely suppressed by either endothelium removal or preincubation with an NOS inhibitor [NG-nitro-L-arginine methyl ester (L-NAME), 10(-3) M]. In SPA from LPS-treated rats, contractions elicited by severe hypoxia occurred irrespective of the presence or absence of endothelium and were largely suppressed by L-NAME. The milder hypoxia elicited no increase in vascular tone. These results indicate an essential role of NO in the hypoxic contractions of precontracted rat SPA. The endothelium independence of HPV in arteries from LPS-treated animals appears related to the extraendothelial expression of iNOS. The severe degree of hypoxia required to elicit any contraction is consistent with a mechanism of reduced NO production caused by a limited availability of O2 as a substrate for NOS.
Resumo:
We have investigated the changes in the responses to noradrenaline of isolated tail arteries of spontaneously hypertensive (SHR) and renovascular hypertensive rats (Wistar-Kyoto: two-kidney, one-clip model, WKY:2K1C) compared with normotensive (Wistar-Kyoto, WKY) rats. Renovascular hypertension was induced by 4 weeks' unilateral renal artery clipping. Arteries were vasoconstricted with exogenous noradrenaline, electrical field stimulation or high potassium. The effects of the latter two stimuli were abolished by reserpine and so were presumably dependent on the presence of endogenous noradrenaline. In the SHR the maximal vasoconstriction produced by all three stimuli was greater than in WKY. Dose-response curves were steeper and there was no change in threshold. Vascular mass was greater. We interpret these results as showing an increase in vascular reactivity in the SHR caused by structural adaptation. The WKY:2K1C responses to noradrenaline could also be explained in terms of structural adaptation but there was no increase in vascular mass. Sensitivity to potassium and electrical stimulation was decreased, suggesting a defect in vascular neurotransmission. This was supported by the observations of a decreased arterial noradrenaline content and of decreased sensitivity to cocaine.
Resumo:
BACKGROUND/AIMS: Restenosis after percutaneous transluminal angioplasty (PTA) of the internal mammary artery (IMA) grafts is much less pronounced than in other arteries and venous grafts. The aim of the study was to test whether various arteries respond differently to dilatation. METHODS: PTA of the IMA, carotid, renal and circumflex coronary (RCx) arteries was performed in 9 pigs (balloon to artery ratio of 1:1.5). After 8 weeks, angiography was repeated and vessels prepared for histological analysis. Immunohistochemical staining was done to examine proliferative activity (Ki67) and to identify the vasa vasorum of the adventitia (F VIII-RA). RESULTS: The intima-media ratio after PTA was lowest in the IMA (0.06), followed by the carotid (0.27) and renal arteries (0.49) and the RCx (0.69). Proliferation of the intima was seen at 287 degrees of the vessel circumference in the RCx, at 286 degrees in the renal and at 166 degrees in the carotid artery. No proliferative activity was seen in the IMA. The intima-adventitia ratio was lower in the IMA than in the RCx and renal arteries (p < 0.05). CONCLUSION: Intima proliferation after PTA varies between the different vessels, with best results seen in the IMA. There are differences in remodeling after PTA between muscular, muscular/elastic and elastic arteries.
Resumo:
BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.
Resumo:
Retrograde or combined retrograde and antegrade recanalization should be considered when antegrade recanalization has failed in selected patients with critical limb ischemia (CLI). Retrograde recanalization is typically attempted through a patent segment of the popliteal artery or an infrapopliteal artery. The challenge arises, however, when there are no patent popliteal or infrapopliteal arteries suitable for retrograde access.
Resumo:
Mesenteric vein thrombosis (MVT) accounts for 5%-15% of all mesenteric ischemic events and is classified as either primary or secondary. Primary MVT is idiopathic, whereas secondary MVT can result from a variety of underlying diseases and risk factors, including primary hypercoagulable states or prothrombotic disorders, myeloproliferative neoplasms, cancer (most frequently of the pancreas or liver), diverse inflammatory conditions, recent surgery, portal hypertension, and miscellaneous causes such as oral contraceptives or pregnancy. Clinical symptoms of MVT are rather nonspecific and are mainly characterized by abdominal pain. The mortality rate for MVT remains high, since even now the diagnosis is often delayed. Multidetector computed tomography (CT) is the modality of choice in this context. Although venous bowel ischemia occurs only infrequently with MVT, radiologists should be familiar with its multidetector CT features. Familiarity with the possible causes of MVT, the underlying pathogenic mechanisms associated with MVT, and the correlation between multidetector CT features and these pathogenic mechanisms is necessary to optimize medical management and improve patient care. © RSNA, 2012.
Resumo:
Rapport de synthèse : Objectif : Le but de ce travail est d`étudier l'angiographie par scanner multi-barrette (AS) dans l'évaluation de l'artériopathie oblitérante (AOMI) de l'aorte abdominale et des membres inférieurs utilisant une méthode adaptative d'acquisition pour optimiser le rehaussement artériel en particulier pour le lit artériel distal et les artères des pieds. Matériels et méthodes : Trente-quatre patients pressentant une AOMI ont bénéficié d'une angiographie trans-cathéter (ATC) et d'une AS dans un délai inférieur ou égal à 15 jours. L'AS a été effectuée du tronc coeliaque jusqu'aux artères des pieds en une seule acquisition utilisant une haute résolution spatiale (16x0.625 mm). La vitesse de table et le temps de rotation pour chaque examen ont été choisis selon le temps de transit du produit de contraste, obtenu après un bolus test. Une quantité totale de 130 ml de contraste à 4 ml/s a été utilisée. L'analyse des images de l'AS a été effectuée par deux observateurs et les données ATC ont été interprétées de manière indépendante par deux autres observateurs. L'analyse a inclus la qualité de l'image et la détection de sténose supérieure ou égale à 50 % par patient et par segment artériel. La sensibilité et la spécificité de l'AS ont été calculées en considérant l'ATC comme examen de référence. La variabilité Interobservateur a été mesurée au moyen d'une statistique de kappa. Résultas : L'ATC a été non-conclusive dans 0.7 % des segments, tandis que l'AS était conclusive dans tous les segments. Sur l'analyse par patient, la sensibilité et la spécificité totales pour détecter une sténose significative égale ou supérieure à 50 % étaient de 100 %. L'analyse par segment a montré des sensibilités et de spécificités variant respectivement de 91 à 100 % et de 81 à 100 %. L'analyse des artères distales des pieds a révélé une sensibilité de 100 % et une spécificité de 90 %. Conclusion : L'angiographie par CT multi-barrettes utilisant cette méthode adaptative d'acquisition améliore la qualité de l'image et fournit une technique non-invasive et fiable pour évaluer L'AOMI, y compris les artères distales des pieds.
Resumo:
Endothelium-derived nitric oxide (EDNO) plays a pivotal role in regulating pulmonary circulation. To determine whether there is a heterogeneity in EDNO-mediated responses of different sized pulmonary vessels, we studied small and large isolated pulmonary arteries of newborn lambs (diameter, 0.4-0.7 and 1.5-2.5 mm, respectively). The isometric tension of vessel rings were recorded while suspended in organ chambers filled with modified Krebs-Ringer bicarbonate solution (95% O2-5% CO2, 37 degrees C). In vessels preconstricted with norepinephrine, acetylcholine and bradykinin induced a greater relaxation of small pulmonary arteries than of large pulmonary arteries. Acetylcholine, bradykinin, and nitric oxide also induced a greater increase in cGMP content in small arteries than in large ones. The responses to acetylcholine and bradykinin were endothelium-dependent and inhibited by nitro-L-arginine, an inhibitor of nitric oxide synthase. In vessels without endothelium, the response to nitric oxide was inhibited by 1H-[1,2,4]oxadiazolo[4,3-a]quinoxalin-1-one, an inhibitor of soluble guanylate cyclase. The activity of soluble guanylyl cyclase of small arteries was greater than that of large arteries under basal conditions and after stimulation with S-nitroso-N-acetylpenicillamine, a nitric oxide donor. These results demonstrate that heterogeneity exists in EDNO-mediated relaxation of small and large pulmonary arteries in newborn lambs. A difference in the soluble guanylate cyclase activity of vascular smooth muscle may have contributed to this phenomenon.
Resumo:
The intravital diagnosis of intracranial arterial dissection is not always possible due to atypic and non-specific clinical and radiological presentations. The postmortem pathological examination of cerebral blood vessels is therefore necessary to establish or confirm the presence of a dissecting aneurysm of intracranial arteries. Most of the described cases showed no significant underlying vascular pathology. Here we present the case of a 24-year-old women who died 5 days after admission to the hospital for a rapidly developing right-sided hemisyndrome. Neuroradiological examination had revealed ill-defined bifrontal hypodense lesions and angiographic findings were compatible with a dissection of the left extracranial internal carotid artery with embolic subocclusion of both anterior cerebral arteries. The pathological evaluation ruled out a thromboembolic occlusion of cerebral arteries and an extracranial internal carotid artery dissection but showed an extended dissecting process of variable age in the anterior circulation of the circle of Willis. The dissected vessels showed pathological changes characteristic of segmental mediolytic "arteritis" [Slavin and Gonzalez-Vitale 1976]. To our knowledge this is the first report on intracranial arteries being affected by this pathologic entity. Our case illustrates the importance of a postmortem examination of dissecting aneurysms of intracranial arteries. Careful serial section studies of dissected intracranial arteries in young subjects should be performed and may allow for a better understanding of the vascular pathology underlying the dissection processus.
Resumo:
L'artériopathie oblitérante des membres inférieurs (AOMI) est une pathologie de plus en plus fréquemment rencontrée en raison du vieillissement le la population et de l'augmentation de la prévalence du diabète. Les patients souffrant d'AOMI se manifestant par une ichémie critique du membre nécessitent un geste de revascularisation, afin que le risque d'amputation, acte fortement morbide, soit diminué. La revascularisation par voie endovasculaire est de nos jours la technique de premier choix mais en cas d'occlusion longue des artères jambières, une approche chirurgicale avec confection d'un pontage ne peut être évitée. La technique nécessite alors, lors de la confection de l'anastomose, de l'occlusion temporaire de l'artère en amont et en aval de rartériotomie, ce qui est réalisé traditionnellement à l'aide de clamps ou cathéters intravasculaires. Ces instruments présentent différents inconvénients reconnus - efficacité médiocre au vu d'artères fortement calcifiées et induction de lésions endothéliales notamment. Un nouveau type d'instrument est apparu sur le marché après approbation de la FDA, sous forme d'un gel thermosensible qui constitue un bouchon occlusif une fois injecté dans l'artère et se dissout spontanément après quelques minutes. Ce gel ayant été expérimenté avec succès en chirurgie cardiovasculaire chez des animaux, nous avons voulu évaluer l'efficacité et l'innocuité de son utilisation lors de la réalisation de pontages fémoro-jambier dans une cohorte de vingt patients. Différents paramètres opératoires ont été notés tels que le volume de gel injecté, les temps d'occlusion efficace et de confection d'anastomose ainsi que la qualité de l'occlusion vasculaire obtenue. Une artériographie per-opératoire a été réalisée de manière systématique à la recherche d'emboles de gel résiduel. Les taux de perméabilité primaire, de sauvetage de membre et de survie à 6 mois ont été rapportés. Les résultats sont satisfaisants puisque la qualité d'occlusion a été jugée bonne à excellente dans la totalité des cas sans qu'aucun instrument d'occlusion supplémentaire n'ait dû être employé et que le temps d'occlusion dépassait légèrement le temps nécessaire à la confection de l'anastomose. L'artériographie des deux premiers cas seulement a révélé la présence d'emboles distaux, avant que nous corrigions notre technique pour obtenir une dissolution instantanée du gel. Nous avons obtenu à 6 mois un taux de perméabilité primaire de 75% avec un taux de sauvetage de membre à 87.5%, le taux de mortalité à 30 jours étant de 10% - sans relation avec le gel. En conclusion, nous avons montré que l'utilisation de ce gel comme instrument d'occlusion vasculaire temporaire est sûre et efficace lors de la chirurgie de pontage fémoro-jambier. L'hypothèse qu'il pourrait être moins délétère pour l'endothélium et contribuer ainsi à une amélioration du taux de perméabilité des pontages distaux mériterait d'être testée dans le cadre d'une étude randomisée multicentrique.