Pulmonary edema is a problem of major clinical importance resulting from a persistent imbalance between forces that drive water into the airspace of the lung and the biological mechanisms for its removal. Here, we will first review the fundamental mechanisms implicated in the regulation of lung fluid homeostasis, namely, the Starling forces and the respiratory transepithelial sodium transport. Second, we will discuss the contribution of hypoxia to the perturbation of this fine balance and the role of such perturbations in the development of high-altitude pulmonary edema, a disease characterized by a very high morbidity and mortality. Finally, we will review possible interventions aimed to maintain/restore lung fluid homeostasis and their importance for the prevention/treatment of pulmonary edema.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Situating events and traces in time is an essential problem in investigations. To date, among the typical ques- 21¦tions issued in forensic science, time has generally been unexplored. The reason for this can be traced to the 22¦complexity of the overall problem, addressed by several scientists in very limited projects usually stimulated 23¦by a specific case. Considering that such issues are recurrent and transcending the treatment of each trace 24¦separately, the formalisation of a framework to address dating issues in criminal investigation is undeniably 25¦needed. Through an iterative process consisting of extracting recurrent aspects discovered from the study of 26¦problems encountered by practitioners and reported in the literature, common mechanisms were extracted 27¦and provide understanding of underlying factors encountered in forensic practise. Three complementary ap- 28¦proaches are thus highlighted and described to formalise a preliminary framework that can be applied for the 29¦dating of traces, objects, persons and indirectly events.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The identification of the presence of active signaling between astrocytes and neurons in a process termed gliotransmission has caused a paradigm shift in our thinking about brain function. However, we are still in the early days of the conceptualization of how astrocytes influence synapses, neurons, networks, and ultimately behavior. In this Perspective, our goal is to identify emerging principles governing gliotransmission and consider the specific properties of this process that endow the astrocyte with unique functions in brain signal integration. We develop and present hypotheses aimed at reconciling confounding reports and define open questions to provide a conceptual framework for future studies. We propose that astrocytes mainly signal through high-affinity slowly desensitizing receptors to modulate neurons and perform integration in spatiotemporal domains complementary to those of neurons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Lung clearance index (LCI), a marker of ventilation inhomogeneity, is elevated early in children with cystic fibrosis (CF). However, in infants with CF, LCI values are found to be normal, although structural lung abnormalities are often detectable. We hypothesized that this discrepancy is due to inadequate algorithms of the available software package. AIM: Our aim was to challenge the validity of these software algorithms. METHODS: We compared multiple breath washout (MBW) results of current software algorithms (automatic modus) to refined algorithms (manual modus) in 17 asymptomatic infants with CF, and 24 matched healthy term-born infants. The main difference between these two analysis methods lies in the calculation of the molar mass differences that the system uses to define the completion of the measurement. RESULTS: In infants with CF the refined manual modus revealed clearly elevated LCI above 9 in 8 out of 35 measurements (23%), all showing LCI values below 8.3 using the automatic modus (paired t-test comparing the means, P < 0.001). Healthy infants showed normal LCI values using both analysis methods (n = 47, paired t-test, P = 0.79). The most relevant reason for false normal LCI values in infants with CF using the automatic modus was the incorrect recognition of the end-of-test too early during the washout. CONCLUSION: We recommend the use of the manual modus for the analysis of MBW outcomes in infants in order to obtain more accurate results. This will allow appropriate use of infant lung function results for clinical and scientific purposes. Pediatr Pulmonol. 2015; 50:970-977. © 2015 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L'abcès pulmonaire se présente de manière très pléomorphe selon les germes initialement impliqués. Des symptômes gé­ néraux et une évolution souvent subaiguë sont retrouvés en cas d'aspiration de la flore oropharyngée, chez des patients avec des troubles de l'état de conscience ou de la déglutition. L'infection est très souvent polymicrobienne, avec présence de germes anaérobes dans deux tiers des cas. La prise en charge consiste en un traitement antibiotique prolongé, jusqu'à résolution ou stabilité de l'image radiologique. En cas d'état toxique ou d'absence de drainage bronchique spontané, un drainage de l'abcès est à discuter. Les sanctions chirurgicales sont peu souvent nécessaires et envisagées indépendamment de la taille de l'abcès excepté lors de néoplasie sous-jacente. Lung abscess occurs in very pleomorphic according to germs initially involved. The mechanism commonly found is an aspiration of the oropharyngeal flora in patients with disorders of consciousness or swallowing. The infection is polymicrobial, with presence of anaerobic germs in 2/3 of the cases. The support consists of a prolonged antibiotic treatment, as well as anaerobic until resolution or stability of the radiological image. In case of prolonged toxic state, drainage of the abscess is to be discussed especially if there is no airways drainage. Surgical sanctions is rarely needed regardless of the size of the abscess, unless underlying carcinoma is present.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Chronic obstructive pulmonary disease (COPD) has been associated with increased risk for heart failure (HF). The impact of subclinical abnormal spirometric findings on HF risk among older adults without history of COPD is not well elucidated. Methods: We evaluated 2125 participants (age 73.6±2.9 years; 50.5% men; 62.3% white; 45.6/9.4% past/current smokers; body mass index [BMI] 27.2±4.6 kg/m2) without prevalent COPD or HF who underwent baseline spirometry in the Health ABC Study. Abnormal lung function was defined either as forced vital capacity (FVC) below lower limit of normal (LLN) or forced expiratory volume in 1st sec (FEV1) to FVC ratio below LLN. Results: On follow-up (median, 9.4 years), 68 of 350 (19.4%) participants with abnormal lung function developed HF, as compared to 172 of 1775 (9.7%) participants with normal lung function (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.74 -3.06; P<.001). This increased risk persisted after adjusting for all other independent predictors of HF in the Health ABC Study, BMI, incident coronary events, and several inflammatory markers (HR, 1.82; 95% CI, 1.30 -2.54; P<.001), and remained constant over time. Baseline FVC and FEV1 had a linear association with HF risk (Figure). In adjusted models, HF risk increased by 21% (95% CI, 10 -36%) per 10% decrease in FVC and 18% (95% CI, 10 -28%) per 10% decrease in FEV1 (both P<.001); this association persisted among participants with normal lung function at baseline. Findings were consistent across sex, race, and smoking status. Conclusions: Subclinical abnormal spirometric findings are prevalent among older adults and are independently associated with risk for incident HF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to assess the effects of an extreme mountain ultramarathon (MUM, 330 km, 24,000 D+) on lung function. Twenty-nine experienced male ultramarathon runners performed longitudinally [before (pre), during (mid), and immediately after (post) a MUM] a battery of pulmonary function tests. The tests included measurements of forced vital capacity, forced expiratory volume in 1 s, peak flow, inspiratory capacity, and maximum voluntary ventilation in 12 s (MVV12). A significant reduction in the running speed was observed (-43.0% between pre-mid and mid-post; P < 0.001). Expiratory function declined significantly at mid (P < 0.05) and at post (P < 0.05). A similar trend was observed for inspiratory function (P < 0.05). MVV12 declined at mid (P < 0.05) and further decreased at post (P < 0.05). Furthermore, there are significant negative correlations between performance time and MVV12 pre-race (R = -0.54, P = 0.02) as well as changes in MVV12 between pre- and post-race (R = -0.53, P = 0.009). It is concluded that during an extreme MUM, a continuous decline in pulmonary function was observed, likely attributable to the high levels of ventilation required during this MUM in a harsh mountainous environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Community-acquired respiratory viral infections (RVIs) are common in lung transplant patients and may be associated with acute rejection and bronchiolitis obliterans syndrome (BOS). The use of sensitive molecular methods that can simultaneously detect a large panel of respiratory viruses may help better define their effects. METHODS: Lung transplant recipients undergoing serial surveillance and diagnostic bronchoalveolar lavages (BALs) during a period of 3 years were enrolled. BAL samples underwent multiplex testing for a panel of 19 respiratory viral types/subtypes using the Luminex xTAG respiratory virus panel assay. RESULTS: Demographics, symptoms, and forced expiratory volume in 1 sec were prospectively collected for 93 lung transplant recipients enrolled. Mean number of BAL samples was 6.2+/-3.1 per patient. A respiratory virus was isolated in 48 of 93 (51.6%) patients on at least one BAL sample. Of 81 positive samples, the viruses isolated included rhinovirus (n=46), parainfluenza 1 to 4 (n=17), coronavirus (n=11), influenza (n=4), metapneumovirus (n=4), and respiratory syncytial virus (n=2). Biopsy-proven acute rejection (> or =grade 2) or decline in forced expiratory volume in 1 sec > or =20% occurred in 16 of 48 (33.3%) patients within 3 months of RVI when compared with 3 of 45 (6.7%) RVI-negative patients within a comparable time frame (P=0.001). No significant difference was seen in incidence of acute rejection between symptomatic and asymptomatic patients. Biopsy-proven obliterative bronchiolitis or BOS was diagnosed in 10 of 16 (62.5%) patients within 1 year of infection. CONCLUSION: Community-acquired RVIs are frequently detected in BAL samples from lung transplant patients. In a significant percentage of patients, symptomatic or asymptomatic viral infection is a trigger for acute rejection and obliterative bronchiolitis/BOS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is renewed interest in the immune regulatory role of the spleen in oncology. To date, very few studies have examined macroscopic variations of splenic volume in the setting of cancer, prior to or during therapy, especially in humans. Changes in splenic volume may be associated with changes in splenic function. The purpose of this study was to investigate variations in spleen volume in NSCLC patients during chemo-radiotherapy. Sixty patients with stage I-IIIB NSCLC underwent radiotherapy (60Gy/30 fractions) for six weeks with concomitant carboplatin/paclitaxel (Ca/P; n = 32) or cisplatin/etoposide (Ci/E; n = 28). A baseline PET/CT scan was performed within 2 weeks prior to treatment and during Weeks 2 and 4 of chemo-radiotherapy. Spleen volume was measured by contouring all CT slices. Significant macroscopic changes in splenic volume occurred early after the commencement of treatment. A significant decrease in spleen volume was observed for 66% of Ca/P and 79% of Ci/E patients between baseline and Week 2. Spleen volume was decreased by 14.2% for Ca/P (p<0.001) and 19.3% for Ci/E (p<0.001) patients. By Week 4, spleen volume was still significantly decreased for Ca/P patients compared to baseline, while for Ci/E patients, spleen volume returned to above baseline levels. This is the first report demonstrating macroscopic changes in the spleen in NSCLC patients undergoing radical chemo-radiotherapy that can be visualized by non-invasive imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The introduction of engineered nanostructured materials into a rapidly increasing number of industrial and consumer products will result in enhanced exposure to engineered nanoparticles. Workplace exposure has been identified as the most likely source of uncontrolled inhalation of engineered aerosolized nanoparticles, but release of engineered nanoparticles may occur at any stage of the lifecycle of (consumer) products. The dynamic development of nanomaterials with possibly unknown toxicological effects poses a challenge for the assessment of nanoparticle induced toxicity and safety.In this consensus document from a workshop on in-vitro cell systems for nanoparticle toxicity testing11Workshop on 'In-Vitro Exposure Studies for Toxicity Testing of Engineered Nanoparticles' sponsored by the Association for Aerosol Research (GAeF), 5-6 September 2009, Karlsruhe, Germany. an overview is given of the main issues concerning exposure to airborne nanoparticles, lung physiology, biological mechanisms of (adverse) action, in-vitro cell exposure systems, realistic tissue doses, risk assessment and social aspects of nanotechnology. The workshop participants recognized the large potential of in-vitro cell exposure systems for reliable, high-throughput screening of nanoparticle toxicity. For the investigation of lung toxicity, a strong preference was expressed for air-liquid interface (ALI) cell exposure systems (rather than submerged cell exposure systems) as they more closely resemble in-vivo conditions in the lungs and they allow for unaltered and dosimetrically accurate delivery of aerosolized nanoparticles to the cells. An important aspect, which is frequently overlooked, is the comparison of typically used in-vitro dose levels with realistic in-vivo nanoparticle doses in the lung. If we consider average ambient urban exposure and occupational exposure at 5mg/m3 (maximum level allowed by Occupational Safety and Health Administration (OSHA)) as the boundaries of human exposure, the corresponding upper-limit range of nanoparticle flux delivered to the lung tissue is 3×10-5-5×10-3μg/h/cm2 of lung tissue and 2-300particles/h/(epithelial) cell. This range can be easily matched and even exceeded by almost all currently available cell exposure systems.The consensus statement includes a set of recommendations for conducting in-vitro cell exposure studies with pulmonary cell systems and identifies urgent needs for future development. As these issues are crucial for the introduction of safe nanomaterials into the marketplace and the living environment, they deserve more attention and more interaction between biologists and aerosol scientists. The members of the workshop believe that further advances in in-vitro cell exposure studies would be greatly facilitated by a more active role of the aerosol scientists. The technical know-how for developing and running ALI in-vitro exposure systems is available in the aerosol community and at the same time biologists/toxicologists are required for proper assessment of the biological impact of nanoparticles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The aim of the present report is to describe abnormal (18)F-fluorodeoxyglucose (FDG) accumulation patterns in the pleura and lung parenchyma in a group of lung cancer patients in whom lung infarction was present at the time of positron emission tomography (PET). METHODS: Between November 2002 and December 2003, a total of 145 patients (102 males, 43 females; age range 38-85 years) were subjected to whole-body FDG PET for initial staging (n=117) or restaging (n=11) of lung cancer or for evaluation of solitary pulmonary nodules (n=17). Of these patients, 24 displayed abnormal FDG accumulation in the lung parenchyma that was not consistent with the primary lesion under investigation (ipsilateral n=12, contralateral n=9 or bilateral n=3). Without correlative imaging, this additional FDG uptake would have been considered indeterminate in differential diagnosis. RESULTS: Of the 24 patients who were identified as having such lesions, six harboured secondary tumour nodules diagnosed as metastases, while in three the diagnosis of a synchronous second primary lung tumour was established. Additionally, nine patients were identified as having post-stenotic pneumonia and/or atelectasis (n=6) or granulomatous lung disease (n=3). In the remaining six (4% of all patients), a diagnosis of recent pulmonary embolism that topographically matched the additional FDG accumulation (SUV(max) range 1.4-8.6, mean 3.9) was made. Four of these six patients were known to have pulmonary embolism, and hence false positive interpretation was avoided by correlating the PET findings with those of the pre-existing diagnostic work-up. The remaining two patients were harbouring small occult infarctions that mimicked satellite nodules in the lung periphery. Based on histopathological results, the abnormal FDG accumulation in these two patients was attributed to the inflammatory reaction and tissue repair associated with the pathological cascade of pulmonary embolism. CONCLUSION: In patients with pulmonary malignancies, synchronous lung infarction may induce pathological FDG accumulation that can mimic active tumour manifestations. Identifying this potential pitfall may allow avoidance of false positive FDG PET interpretation.