28 resultados para Lindahl, Rutger: Non-alignment and European security policy
Resumo:
In this article, we analyze the rationale for introducing outlier payments into a prospective payment system for hospitals under adverse selection and moral hazard. The payer has only two instruments: a fixed price for patients whose treatment cost is below a threshold and a cost-sharing rule for outlier patients. We show that a fixed-price policy is optimal when the hospital is sufficiently benevolent. When the hospital is weakly benevolent, a mixed policy solving a trade-off between rent extraction, efficiency, and dumping deterrence must be preferred. We show how the optimal combination of fixed price and partially cost-based payment depends on the degree of benevolence of the hospital, the social cost of public funds, and the distribution of patients severity. [Authors]
Resumo:
The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.
Resumo:
Current hypertension guidelines point to the necessity of achieving sustained and strict blood pressure control in every hypertensive patient. To reach this goal the patient should comply both with hygienic measures and pharmacologic treatment. This remains a difficult task, particularly since hypertension is generally asymptomatic and since any therapeutic intervention might adversely alter the patient's quality of life. Long-term persistence with antihypertensive therapy is facilated when the treatment is initiated with well tolerated antihypertensive agents, especially blockers of the renin-angiotensin system. Having a normal blood pressure during treatment is also an important determinant of persistence. This explains the growing interest for fixed-dose combinations, which have the main advantage to be at the same time efficient and well tolerated. These simple to use preparations have even gained acceptance as first-line drug regimen.
Resumo:
Invasive studies suggest that healthy children living at high altitude display pulmonary hypertension, but the data to support this assumption are sparse. Nitric oxide (NO) synthesized by the respiratory epithelium regulates pulmonary artery pressure, and its synthesis was reported to be increased in Aymara high-altitude dwellers. We hypothesized that pulmonary artery pressure will be lower in Aymara children than in children of European ancestry at high altitude, and that this will be related to increased respiratory NO. We therefore compared pulmonary artery pressure and exhaled NO (a marker of respiratory epithelial NO synthesis) between large groups of healthy children of Aymara (n = 200; mean +/- SD age, 9.5 +/- 3.6 years) and European ancestry (n = 77) living at high altitude (3,600 to 4,000 m). We also studied a group of European children (n = 29) living at low altitude. The systolic right ventricular to right atrial pressure gradient in the Aymara children was normal, even though significantly higher than the gradient measured in European children at low altitude (22.5 +/- 6.1 mm Hg vs 17.7 +/- 3.1 mm Hg, p < 0.001). In children of European ancestry studied at high altitude, the pressure gradient was 33% higher than in the Aymara children (30.0 +/- 5.3 mm Hg vs 22.5 +/- 6.1 mm Hg, p < 0.0001). In contrast to what was expected, exhaled NO tended to be lower in Aymara children than in European children living at the same altitude (12.4 +/- 8.8 parts per billion [ppb] vs 16.1 +/- 11.1 ppb, p = 0.06) and was not related to pulmonary artery pressure in either group. Aymara children are protected from hypoxic pulmonary hypertension at high altitude. This protection does not appear to be related to increased respiratory NO synthesis.
Resumo:
Autonomic neuropathy is a well known complication of diabetes. Diabetes is often superimposed on obesity. A reduction in the variability of the heart rate in the resting state has been demonstrated in 16 obese diabetic subjects as well as in 34 obese non-diabetic subjects. The coefficient of variation (CV) of the heart rate during 30 minutes of resting was significantly decreased in both obese groups (3.9 +/- 0.2% for the diabetics; 5.2 +/- 0.2%, p less than 0.01 for the non diabetics) as compared to their own controls (4.5 +/- 0.6% and 6.5 +/- 0.4%, respectively). Age also contributes to decreased heart rate variability. Furthermore, this defect of autonomic function has been correlated with the blunted glucose-induced thermogenesis (GIT) seen in both obese groups (r = 0.52, p. less than 0.001): the increase in energy expenditure over basal values following a 100 g oral glucose load was only 4.8 +/- 0.8% for the diabetic obese group (p less than 0.001), and 8.5 +/- 0.7% for the non-diabetic obese group (p less than 0.001) as opposed to their own controls (12.4 +/- 1.3% and 13.3 +/- 0.6% respectively). Measurement of the variability of heart rate in obese individuals may be of predictive value in assessing blunted glucose-induced thermogenesis in non diabetic and diabetic obese patients.
Resumo:
Mobile technologies have brought about major changes in police equipment and police work. If a utopian narrative remains strongly linked to the adoption of new technologies, often formulated as 'magic bullets' to real occupational problems, there are important tensions between their 'imagined' outcomes and the (unexpected) effects that accompany their daily 'practical' use by police officers. This article offers an analysis of police officers' perceptions and interactions with security devices. In so doing, it develops a conceptual typology of strategies for coping with new technology inspired by Le Bourhis and Lascoumes: challenging, neutralizing and diverting. To that purpose, we adopt an ethnographic approach that focuses on the discourses, practices and actions of police officers in relation to three security devices: the mobile digital terminal, the mobile phone and the body camera. Based on a case study of a North American municipal police department, the article addresses how these technological devices are perceived and experienced by police officers on the beat.