32 resultados para Knowledge Transfer 2.0
Resumo:
Introduction: In forensic toxicology, cocaine is better known for its powerful stimulating effects of nervous system and its high potential for recreational abuse, than for his therapeutic use. However, cocaine is still use as a topical anesthetic and peripheral vasoconstrictor in surgeries of eye, ear, nose and throat. Last decade, an increase of the presence of cocaine and metabolites in blood samples of drivers suspected to drive under the influence of drugs (DUID) was observed in Switzerland (Augsburger et al., Forensic Sci Int 153 (2005) 11-15; Senna et al., Forensic Sci Int 198 (2010) 11-16). Observed blood concentration ranges of cocaine and benzoylecgonine were 10-925 μg/L and 20-5200 μg/L, respectively. Since 2005, zero-tolerance approach was introduced in the Swiss legislation for different substances, especially cocaine (analytical cutoff: 15 μg/L). Thus, the interpretation often amounts to determine if the concentration is situated above or under the limit. However, it is important for the interpretation to take into account the context and to be critical with the obtained results, at the risk of ending in erroneous conclusions. Methods: Systematical toxicological analyses were performed on blood and urine, if available, for 5 DUID cases, as already published (Augsburger et al., Forensic Sci Int 153 (2005)). Positive results were confirmed and drugs were quantified in biological samples by GCMS, GC-MS/MS or LC-MS/MS. Results: Administration of cocaine after traffic accident was identified in five cases. All people were admitted to the emergency room because of severe trauma. Maxillofacial surgery was done shortly after admission to the emergency room, involving use of nasal application of cocaine (swab). For all cases, use of cocaine swab was not mentioned in the document filled by the police and by medical staff requested for blood and urine sampling. The information was obtained retrospectively after consultation of the medical records, without precise indication of the application time or dose. Case 1. A 83-year old man (pedestrian) was hit by a car. Blood (+11h after the accident): cocaine (16 μg/L), benzoylecgonine (370 μg/L). Urine: cocaine (1700 μg/L), benzoylecgonine (560 μg/L). Case 2. A 84-year old woman (pedestrian) was hit by a car. Blood (+1.5h after the accident): cocaine (230 μg/L), benzoylecgonine (370 μg/L). Urine was not available. Hair (+4 months after the accident): segment 1 (0-2 cm), cocaine not detected; segment 2 (2-4 cm), cocaine: <0.5 ng/mg. Case 3. A 66-year old man was involved in a car/car accident. He died 2 hours and 5 minutes after the crash. Blood (+1.5h after the accident): cocaine and metabolites not detected. Blood (+2h after the accident): cocaine (1750 μg/L), benzoylecgonine (460 μg/L). Blood (post-mortem): cocaine (370 μg/L), benzoylecgonine (200 μg/L). Urine (+1.5h after the accident): cocaine not detected. Case 4. A 57-year old woman on a motor scooter was hit by a car. She died 2 hours and 10 minutes after the crash. Blood (+0.5h after the accident): cocaine and metabolites not detected. Urine (post-mortem): cocaine (<20 μg/L), benzoylecgonine (120 μg/L). Case 5. A 30-year old man was involved in a car accident. Blood (+4h after the accident): cocaine (29 μg/L), benzoylecgonine (< 20 μg/L). Urine (+4h after the accident): cocaine and metabolites not detected. Ethanol (1,32 g/kg) and cannabinoids (THC (2,0 μg/L), THCCOOH (38 μg/L)) were also detected in blood. Conclusion: To our knowledge, this is the first description of DUID cases involving therapeutic use of cocaine after an accident. These results indicate that even if a per se law is effective for prosecution case of DUID, a critical interpretation of the results is always needed, especially if a medical intervention occurs after an accident.
Resumo:
The recently released Affymetrix Human Gene 1.0 ST array has two major differences compared with standard 3' based arrays: (i) it interrogates the entire mRNA transcript, and (ii) it uses DNA targets. To assess the impact of these differences on array performance, we performed a series of comparative hybridizations between the Human Gene 1.0 ST and the Affymetrix HG-U133 Plus 2.0 and the Illumina HumanRef-8 BeadChip arrays. Additionally, both RNA and DNA targets were hybridized on HG-U133 Plus 2.0 arrays. The results show that the overall reproducibility of the Gene 1.0 ST array is best. When looking only at the high intensity probes, the reproducibility of the Gene 1.0 ST array and the Illumina BeadChip array is equally good. Concordance of array results was assessed using different inter-platform mappings. Agreements are best between the two labeling protocols using HG-U133 Plus 2.0 array. The Gene 1.0 ST array is most concordant with the HG-U133 array hybridized with cDNA targets. This may reflect the impact of the target type. Overall, the high degree of correspondence provides strong evidence for the reliability of the Gene 1.0 ST array.
Resumo:
We measured body composition and energy expenditure during walking and running on a treadmill in 40 prepubertal children: 23 obese children (9.3 +/- 1.1 years of age; 46 +/- 10 kg (mean +/- SD)) and 17 nonobese matched control children (9.2 +/- 0.6 years of age; 30 +/- 5 kg). Energy expenditure was assessed by indirect calorimetry with a standard open-circuit method. At the same speed of exercise, the energy expenditure was significantly (p < 0.01) greater in obese than in control children, in both boys and girls. Expressed per kilogram of body weight or per kilogram of fat-free mass, the energy expenditure was comparable in the two groups. Obese children had a significantly (p < 0.01) larger pulmonary ventilatory response to exercise than did control children. Heart rate was comparable in boys and girls combined but significantly higher (p < 0.05) in obese subjects, if boys and girls were analyzed separately. These data indicate that walking and running are energetically more expensive for obese children than for children of normal body weight. The knowledge of these energy costs could be useful in devising a physical activity program to be used in the treatment of obese children.
Resumo:
The pace of development of new healthcare technologies and related knowledge is very fast. Implementation of high quality evidence-based knowledge is thus mandatory to warrant an effective healthcare system and patient safety. However, even though only a small fraction of the approximate 2500 scientific publication indexed daily in Medline is actually useful to clinical practice, the amountof the new information is much too large to allow busy healthcare professionals to stay aware of possibly important evidence-based information.
Resumo:
Knowledge of the relative importance of genetics and behavioural copying is crucial to appraise the evolvability of behavioural consistencies. Yet, genetic and non-genetic factors are often deeply intertwined, and experiments are required to address this issue. We investigated the sources of variation of adult antipredator behaviour in the Alpine swift (Apus melba) by making use of long-term behavioural observations on parents and cross-fostered offspring. By applying an 'animal model' approach to observational data, we show that antipredator behaviour of adult Alpine swifts was significantly repeatable over lifetime (r = 0.273) and heritable (h(2) = 0.146). Regression models also show that antipredator behaviours differed between colonies and sexes (females were more tame), and varied with the hour and year of capture. By applying a parent-offspring regression approach to 59 offspring that were exchanged as eggs or hatchlings between pairs of nests, we demonstrate that offspring behaved like their biological parents rather than like their foster parents when they were adults themselves. Those findings provide strong evidence that antipredator behaviour of adult Alpine swifts is shaped by genetics and/or pre-hatching maternal effects taking place at conception but not by behavioural copying.
Resumo:
BACKGROUND: Transient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique. METHODS: A 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner. RESULTS: The 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively). CONCLUSIONS: The 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period.
Resumo:
Plasmid DNA and adenovirus vectors currently used in cardiovascular gene therapy trials are limited by low efficiency and short-lived transgene expression, respectively. Recombinant adeno-associated virus (AAV) has recently emerged as an attractive vector for cardiovascular gene therapy. In the present study, we have compared AAV and adenovirus vectors with respect to gene transfer efficiency and the duration of transgene expression in mouse hearts and arteries in vivo. AAV vectors (titer: 5 x 10(8) transducing units (TU)/ml) and adenovirus vectors (1.2 x 10(10) TU/ml) expressing a green fluorescent protein (EGFP) gene were injected either intramyocardially (n=32) or intrapericardially (n=3) in CD-1 mice. Hearts were harvested at varying time intervals (3 days to 1 year) after gene delivery. After intramyocardial injection of 5 microl virus stock solution, cardiomyocyte transduction rates with AAV vectors were 4-fold lower than with adenovirus vectors (1.5% (range: 0.5-2.6%) vs. 6.2% (range: 2.7-13.7%); P<0.05), but similar to titer-matched adenovirus vectors (0.7%; range: 0.2-1.2%). AAV-mediated EGFP expression lasted for at least 1 year. AAV vectors instilled into the pericardial space transduced epicardial myocytes. Arterial gene transfer was studied in mouse carotids (n=26). Both vectors selectively transduced endothelial cells after luminal instillation. Transduction rates with AAV vectors were 8-fold lower than with adenovirus vectors (2.0% (range: 0-3.2%) vs. 16.2% (range: 8.5-20.2%); P<0.05). Prolonged EGFP expression was observed after AAV but not adenovirus-mediated gene transfer. In conclusion, AAV vectors deliver and express genes for extended periods of time in the myocardium and arterial endothelium in vivo. AAV vectors may be useful for gene therapy approaches to chronic cardiovascular diseases.
Resumo:
PURPOSE: Hypertriglyceridemia (hyperTG) is common among intensive care unit (ICU) patients, but knowledge about hyperTG risk factors is scarce. The present study aims to identify risk factors favoring its development in patients requiring prolonged ICU treatment. METHODS: Prospective observational study in the medicosurgical ICU of a university teaching hospital. All consecutive patients staying ≥4 days were enrolled. Potential risk factors were recorded: pathology, energy intake, amount and type of nutritional lipids, intake of propofol, glucose intake, laboratory parameters, and drugs. Triglyceride (TG) levels were assessed three times weekly. Statistics was based on two-way analysis of variance (ANOVA) and linear regression with potential risk factors. RESULTS: Out of 1,301 consecutive admissions, 220 patients were eligible, of whom 99 (45 %) presented hyperTG (triglycerides >2 mmol/L). HyperTG patients were younger, heavier, with more brain injury and multiple trauma. Intake of propofol (mg/kg/h) and lipids' propofol had the highest correlation with plasma TG (r (2) = 0.28 and 0.26, respectively, both p < 0.001). Infection and inflammation were associated with development of hyperTG [C-reactive protein (CRP), r (2) = 0.19, p = 0.004]. No strong association could be found with nutritional lipids or other risk factors. Outcome was similar in normo- and hyperTG patients. CONCLUSIONS: HyperTG is frequent in the ICU but is not associated with adverse outcome. Propofol and accompanying lipid emulsion are the strongest risk factors. Our results suggest that plasma TG should be monitored at least twice weekly in patients on propofol. The clinical consequences of propofol-related hyperTG should be investigated in further studies.
Resumo:
BACKGROUND: Only 25% of IVF transfer cycles lead to a clinical pregnancy, calling for continued technical progress but also more in depth analysis of patients' individual characteristics. The interleukin-1 (IL-1) system and matrix metalloproteinases (MMPs) are strongly implicated in embryo implantation. The genes coding for IL-1Ra (gene symbol IL-1RN), IL-1beta, MMP2 and MMP9 bear functional polymorphisms. We analysed the maternal genetic profile at these polymorphic sites in IVF patients, to determine possible correlations with IVF outcome. METHODS: One hundred and sixty women undergoing an IVF cycle were enrolled and a buccal smear was obtained. The presence of IL-1RN variable number of tandem repeats and IL-1B + 3953, MMP2-1306 and MMP9-1562 single nucleotide substitutions were determined. Patients were divided into pregnancy failures (119), biochemical pregnancies (8) and clinical pregnancies (33). RESULTS: There was a 40% decrease in IL-1RN*2 allele frequency (P = 0.024) and a 45% decrease in IL-1RN*2 carrier status in the clinical pregnancy group as compared to the pregnancy failure group (P = 0.017). This decrease was still statistically significant after a multivariate logistic regression analysis. The likelihood of a clinical pregnancy was decreased accordingly in IL-1RN*2 carriers: odds ratio = 0.349, 95% confidence interval = 0.2-0.8, P = 0.017. The IL-1B, MMP2 and MMP9 polymorphisms showed no correlation with IVF outcome. CONCLUSIONS: IL-1RN*2 allele carriage is associated with a poor prognosis of achieving a pregnancy after IVF.
Resumo:
INTRODUCTION: In patients with multiple sclerosis (MS), conventional magnetic resonance imaging (MRI) provides only limited insights into the nature of brain damage with modest clinic-radiological correlation. In this study, we applied recent advances in MRI techniques to study brain microstructural alterations in early relapsing-remitting MS (RRMS) patients with minor deficits. Further, we investigated the potential use of advanced MRI to predict functional performances in these patients. METHODS: Brain relaxometry (T1, T2, T2*) and magnetization transfer MRI were performed at 3T in 36 RRMS patients and 18 healthy controls (HC). Multicontrast analysis was used to assess for microstructural alterations in normal-appearing (NA) tissue and lesions. A generalized linear model was computed to predict clinical performance in patients using multicontrast MRI data, conventional MRI measures as well as demographic and behavioral data as covariates. RESULTS: Quantitative T2 and T2* relaxometry were significantly increased in temporal normal-appearing white matter (NAWM) of patients compared to HC, indicating subtle microedema (P = 0.03 and 0.004). Furthermore, significant T1 and magnetization transfer ratio (MTR) variations in lesions (mean T1 z-score: 4.42 and mean MTR z-score: -4.09) suggested substantial tissue loss. Combinations of multicontrast and conventional MRI data significantly predicted cognitive fatigue (P = 0.01, Adj-R (2) = 0.4), attention (P = 0.0005, Adj-R (2) = 0.6), and disability (P = 0.03, Adj-R (2) = 0.4). CONCLUSION: Advanced MRI techniques at 3T, unraveled the nature of brain tissue damage in early MS and substantially improved clinical-radiological correlations in patients with minor deficits, as compared to conventional measures of disease.
Resumo:
INTRODUCTION: Delirium is a highly prevalent disorder, with serious consequences for the hospitalised patient. Nevertheless, it remains under-diagnosed and under-treated. We developed evidence-based clinical practice guidelines (CPGs) focusing on prevention, screening, diagnosis, and treatment of delirium in a general hospital. This article presents the implementation process of these CPGs and a before-after study assessing their impact on healthcare professionals' knowledge and on clinical practice. METHODS: CPGs on delirium were first implemented in two wards (Neurology and Neurosurgery) of the Lausanne university hospital. Interactive one-hour educational sessions for small groups of nurses and physicians were organised. Participants received a summary of the guidelines and completed a multiple choice questionnaire, assessing putative changes in knowledge, before and three months after the educational session. Other indicators such as "diagnosis of delirium" reported in the discharge letters, and mean duration of patients' hospital stay before and after implementation were compared. RESULTS: Eighty percent of the nurses and physicians from the Neurology and Neurosurgery wards attended the educational sessions. Both nurses and physicians significantly improved their knowledge after the implementation (+9 percentage-points). Other indicators were not modified by the intervention. CONCLUSION: A single interactive intervention improved both nurses' and physicians' knowledge on delirium. Sustained and repeated interventions are probably needed to demonstrate changes in clinical practice.
Resumo:
Context: Both biallelic and monoallelic mutations in PROK2 or PROKR2 have been found in Kallmann syndrome (KS). Objective: The objective of the study was to compare the phenotypes of KS patients harboring monoallelic and biallelic mutations in these genes. Design and Patients: We studied clinical and endocrine features that reflect the functioning of the pituitary-gonadal axis, and the nonreproductive phenotype, in 55 adult KS patients (42 men and 13 women), of whom 41 had monoallelic mutations and 14 biallelic mutations in PROK2 or PROKR2. Results: Biallelic mutations were associated with more frequent cryptorchidism (70% vs. 34%, P < 0.05) and microphallus (90% vs. 28%, P < 0.001) and lower mean testicular volume (1.2 +/- 0.4 vs. 4.5 +/- 6.0 ml; P < 0.01) in male patients. Likewise, the testosterone level as well as the basal FSH level and peak LH level under GnRH-stimulation were lower in males with biallelic mutations (0.2 +/- 0.1 vs. 0.7 +/- 0.8 ng/ml; P = 0.05, 0.3 +/- 0.1 vs. 1.8 +/- 3.0 IU/liter; P < 0.05, and 0.8 +/- 0.8 vs. 5.2 +/- 5.5 IU/liter; P < 0.05, respectively). Nonreproductive, nonolfactory anomalies were rare in both sexes and were never found in patients with biallelic mutations. The mean body mass index of the patients (23.9 +/- 4.2 kg/m(2) in males and 26.3 +/- 6.6 kg/m(2) in females) did not differ significantly from that of gender-, age-, and treatment-matched KS individuals who did not carry a mutation in PROK2 or PROKR2. Finally, circadian cortisol levels evaluated in five patients, including one with biallelic PROKR2 mutations, were normal in all cases. Conclusion: Male patients carrying biallelic mutations in PROK2 or PROKR2 have a less variable and on average a more severe reproductive phenotype than patients carrying monoallelic mutations in these genes. Nonreproductive, nonolfactory clinical anomalies associated with KS seem to be restricted to patients with monoallelic mutations.
Resumo:
BACKGROUND: Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS: Testing was done for seven home ventilators on a bench model adapted to simulate NIV and generate unintentional leaks (ie, other than of the mask exhalation valve). Five levels of leaks were simulated using a computer-driven solenoid valve (0-60 L/min) at different levels of inspiratory pressure (15 and 25 cm H(2)O) and at a fixed expiratory pressure (5 cm H(2)O), for a total of 10 conditions. Bench data were compared with results retrieved from ventilator software for leaks and Vt. RESULTS: For assessing leaks, three of the devices tested were highly reliable, with a small bias (0.3-0.9 L/min), narrow limits of agreement (LA), and high correlations (R(2), 0.993-0.997) when comparing ventilator software and bench results; conversely, for four ventilators, bias ranged from -6.0 L/min to -25.9 L/min, exceeding -10 L/min for two devices, with wide LA and lower correlations (R(2), 0.70-0.98). Bias for leaks increased markedly with the importance of leaks in three devices. Vt was underestimated by all devices, and bias (range, 66-236 mL) increased with higher insufflation pressures. Only two devices had a bias < 100 mL, with all testing conditions considered. CONCLUSIONS: Physicians monitoring patients who use home ventilation must be aware of differences in the estimation of leaks and Vt by ventilator software. Also, leaks are reported in different ways according to the device used.
Resumo:
Hyperglycosylated human chorionic gonadotropin (H-hCG) is secreted by the placenta in early pregnancy. Decreased H-hCG levels have been associated with abortion in spontaneous pregnancy. We retrospectively measured H-hCG and dimeric hCG in the sera of 87 in vitro fertilization patients obtained in the 3 weeks following embryo transfer and set the results in relation to pregnancy outcome. H-hCG and dimeric hCG were correlated (r(2) = 0.89), and were significantly decreased in biochemical pregnancy (2 microg/l and 18 IU/l, respectively) compared to early pregnancy loss (22 microg/l and 331 IU/l) and ongoing pregnancy (32 microg/l and 353 IU/l). Only H-hCG tended to discriminate between these last two groups.
Resumo:
BACKGROUND AND PURPOSE: Knowledge of cerebral blood flow (CBF) alterations in cases of acute stroke could be valuable in the early management of these cases. Among imaging techniques affording evaluation of cerebral perfusion, perfusion CT studies involve sequential acquisition of cerebral CT sections obtained in an axial mode during the IV administration of iodinated contrast material. They are thus very easy to perform in emergency settings. Perfusion CT values of CBF have proved to be accurate in animals, and perfusion CT affords plausible values in humans. The purpose of this study was to validate perfusion CT studies of CBF by comparison with the results provided by stable xenon CT, which have been reported to be accurate, and to evaluate acquisition and processing modalities of CT data, notably the possible deconvolution methods and the selection of the reference artery. METHODS: Twelve stable xenon CT and perfusion CT cerebral examinations were performed within an interval of a few minutes in patients with various cerebrovascular diseases. CBF maps were obtained from perfusion CT data by deconvolution using singular value decomposition and least mean square methods. The CBF were compared with the stable xenon CT results in multiple regions of interest through linear regression analysis and bilateral t tests for matched variables. RESULTS: Linear regression analysis showed good correlation between perfusion CT and stable xenon CT CBF values (singular value decomposition method: R(2) = 0.79, slope = 0.87; least mean square method: R(2) = 0.67, slope = 0.83). Bilateral t tests for matched variables did not identify a significant difference between the two imaging methods (P >.1). Both deconvolution methods were equivalent (P >.1). The choice of the reference artery is a major concern and has a strong influence on the final perfusion CT CBF map. CONCLUSION: Perfusion CT studies of CBF achieved with adequate acquisition parameters and processing lead to accurate and reliable results.