97 resultados para Implementation principle


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article investigates some central aspects of the relationships between programme structure and implementation of sulphur dioxide air quality control policies. Previous implementation research, primarily adopting American approaches, has neglected the connections between the processes of programme formulation and implementation. 'Programme', as the key variable in implementation studies, has been defined too narrowly. On the basis of theoretical and conceptual reflections and provisional empirical results from studies in France, Italy, England, and the Federal Republic of Germany, the authors demonstrate that an integral process analysis using a more extended programme concept is necessary if patterns of interest recognition in policies are to be discovered. Otherwise, the still important question of critical social science cannot be answered, namely, what is the impact of special interests upon implementation processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Cadaveric study at our institution has demonstrated that optimal basaplate fixation of a reversed shoulder arthroplasty (RSA) could be achieved with screws in three major columns. Our aim was to review our early rate of aseptic glenoid loosening in a series of baseplate fixed according to this principle. Material and Methods Between 2005 and 2008, 48 RSA (Aequalis Reversed) were implanted in 48 patients with an average age of 74.4 years (range, 56 to 86 years). There were 37 women and 11 men. Twenty-seven primary RSAs were performed for cuff tear arthropathy, 3 after failed rotator cuff surgery, 6 for failed arthroplasties, 7 for acute fractures and 5 after failed ORIF. All baseplate fixation were done using a nonlocking posterior screw in the spine, a nonlocking anterior screw in the glenoid body, a locking superior screw in the coracoid and a locking inferior screw in the pillar. All patients were reviewed with standardized radiographs. The number of screws were reported. We measured the position of the screws in relation to the scapular spine and the coracoid process in two different views. We defined screw positions as totally, partially or out of the target. Finally we reported glenoid aseptic loosening which was defined as implant subsidence. Results Four patients were lost to follow-up. Thus, 44 shoulders could be reviewed after a mean follow-up of 13 months (range, 6 to 32 months). All baseplates were fixed with 4 screws. Thirty-seven (84%) screws were either partially or totally in the spine. Thus, 7 (16%) scapular spine screws were out of the target. No coracoid screw was out the target. Two (4.5%) patients had glenoid loosening. Both had a scapular spine and a coracoid screw partially in the bone. Conclusion Early aseptic glenoid loosening occurred before the two years follow-up and is most of time related to technical problems and/or insufficient bone stock and bone quality. Our study demonstrate that baseplate fixation according to the three columns principle is a reproducible technique and a valuable way to prevent early glenoid loosening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Enhanced recovery protocols may reduce postoperative complications and length of hospital stay. However, the implementation of these protocols requires time and financial investment. This study evaluated the cost-effectiveness of enhanced recovery implementation. METHODS: The first 50 consecutive patients treated during implementation of an enhanced recovery programme were compared with 50 consecutive patients treated in the year before its introduction. The enhanced recovery protocol principally implemented preoperative counselling, reduced preoperative fasting, preoperative carbohydrate loading, avoidance of premedication, optimized fluid balance, standardized postoperative analgesia, use of a no-drain policy, as well as early nutrition and mobilization. Length of stay, readmissions and complications within 30 days were compared. A cost-minimization analysis was performed. RESULTS: Hospital stay was significantly shorter in the enhanced recovery group: median 7 (interquartile range 5-12) versus 10 (7-18) days (P = 0·003); two patients were readmitted in each group. The rate of severe complications was lower in the enhanced recovery group (12 versus 20 per cent), but there was no difference in overall morbidity. The mean saving per patient in the enhanced recovery group was euro1651. CONCLUSION: Enhanced recovery is cost-effective, with savings evident even in the initial implementation period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the increasing popularity of enterprise architecture management (EAM) in practice, many EAM initiatives either do not fully meet the expected targets or fail. Several frameworks have been suggested as guidelines to EA implementation, but companies seldom follow prescriptive frameworks. Instead, they follow very diverse implementation approaches that depend on their organizational contingencies and the way of adopting and evolving EAM over time. This research strives for a broader understanding of EAM by exploring context-dependent EAM adoption approaches as well as identifying the main EA principles that affect EA effectiveness. Based on two studies, this dissertation aims to address two main questions: (1) EAM design: Which approaches do companies follow when adopting EAM? (2) EA principles and their impact: What impact does EA principles have on EA effectiveness/quality? By utilizing both qualitative and quantitative research methods, this research contributes to exploring different EAM designs in different organizational contingencies as well as using EA principles as an effective means to achieve principle-based EAM design. My research can help companies identify a suitable EAM design that fits their organizational settings and shape their EA through a set of principles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pace of development of new healthcare technologies and related knowledge is very fast. Implementation of high quality evidence-based knowledge is thus mandatory to warrant an effective healthcare system and patient safety. However, even though only a small fraction of the approximate 2500 scientific publication indexed daily in Medline is actually useful to clinical practice, the amountof the new information is much too large to allow busy healthcare professionals to stay aware of possibly important evidence-based information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ciao is a website specifically designed for young people and focuses mainly on health issues. This report presents the process of setting up the site and a first evaluation undertaken by using two self-administered questionnaires administered via the website itself. It suggests that it is possible to provide young people with authoritative health information and to facilitate their access to counseling and health care facilities by having young people use such a website.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Glenoid bone volume and bone quality can render the fixation of a reversed shoulder arthroplasty (RSA) basis plate hazardous. Cadaveric study at our institution has demonstrated that optimal baseplate fixation could be achieved with screws in three major columns. Our aim is to review our early rate of aseptic glenoid loosening in a series of baseplates fixed according to this principle. Methods: Between 2005 and 2008, 48 consecutive RSA (Reversed Aequalis) were implanted in 48 patients with an average age of 74.4 years (range, 56 to 86 years). There were 37 women and 11 men. Twenty-seven primary RSAs were performed for cuff tear arthropathy, 3 after failed rotator cuff surgery, 6 for failed arthroplasties, 7 for acute fractures and 5 after failed ORIF. All baseplate fixations were done using a nonlocking posterior screw in the scapular spine, a nonlocking anterior screw in the glenoid body, a locking superior screw in the coracoid and a locking inferior screw in the pillar. All patients were reviewed with standardized radiographs. We reported the positions of the screws in relation to the scapular spine and the coracoid process in two different views. We defined screw positions as totally, partially or out of the target. Finally, we reported aseptic glenoid loosening which was defined as implant subsidence. Results: Four patients were lost to follow-up. Thus 44 shoulders could be reviewed after a mean follow-up of 16 months (range, 9 to 32 months). Thirty-seven (84%) screws were either partially or totally in the spine. Thus, 7 (16%) scapular spine screws were out of the target. No coracoid screw was out of the target. At final follow-up control, we reported no glenoid loosening. Conclusion: Early glenoid loosening occurred before the two years follow-up and is most of time related to technical problems and/or insufficient glenoid bone stock and bone quality. Our study demonstrate that baseplate fixation of a RSA according to the three columns principle is a reproducible technique and a valuable way to prevent early glenoid loosening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[Table des matières] 1. Introduction to the control banding method : Nanomaterials and occupational risk assessment; Alternative method known as control banding; Scope and limits of control banding. - 2. Control banding process applied to manufactured nanomaterials: General points; Operating principle. - 3. Implementation of control banding: Gathering of information; Hazard bands; Exposure bands; Allocation of risk control bands. - 4. Bibliography: Publications; Books, reports, opinions, bulletins; Standards and references; Legislation and regulations; Websites. - Annexes