131 resultados para Implantable Collamer lens
Resumo:
Background: The purpose of this study is to report the anatomic and functional results of primary 23 G vitrectomy using slit-lamp and non-contact 90 D lens for the treatment of pseudophakic rhegmatogenous retinal detachment. Patients and Methods: Pseudophakic eyes were operated by 23 G vitrectomy using slit-lamp and non-contact 90 D lens, internal subretinal fluid drainage, cryopexy and internal gas tamponade. The preoperative and postoperative characteristics were analysed. Main outcome measures were anatomic success rates after initial surgical intervention and after reoperation for primary failures, visual outcome at the last follow-up visit, and complications. Results: 46 pseudophakic eyes were included in this retrospective study (October 2013- January 2014). In 40 cases, sulfur hexafluoride 23 % gastamponade was used, silicone oil in 6 cases (13 %). The retina was reattached successfully after a single surgery in 44 eyes (96 %). Recurrence of retinal detachment occurred in 2 eyes. Final anatomic reattachment was obtained in 100 % after a second operation. Silicone oil was removed in all eyes. Visual acuity improved significantly from logMAR 0 (IQR 0 - 0.9) to logMAR 0 (IQR 0 - 0.2) (p < 0.005). Conclusions: Primary 23 G vitrectomy using slit-lamp and non contact 90 D lens for the treatment of pseudophakic rhegmatogenous retinal detachment provides a high anatomic and functional success rate and is associated with few complications.
Resumo:
A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.
Resumo:
Port-a-Cath© (PAC) are totally implantable devices that offer an easy and long term access to venous circulation. They have been extensively used for intravenous therapy administration and are particularly well suited for chemotherapy in oncologic patients. Previous comparative studies have shown that these devices have the lowest catheter-related bloodstream infection rates among all intravascular access systems. However, bloodstream infection (BSI) still remains a major issue of port use and epidemiology data for PAC-associated BSI (PABSI) rates differ strongly depending on studies. Also, current literature about PABSI risk factors is scarce and sometimes controversial. Such heterogeneity may depend on type of studied population and local factors. Therefore, the aim of this study was to describe local epidemiology and risk factors for PABSI in adult patients in our tertiary- care university hospital. We conducted a retrospective cohort study in order to describe local epidemiology. We also performed a nested case-control study to identify local risk factors of PABSI. We analyzed medical files of adult patients who had a PAC implanted between January 1st, 2008 and December 31st, 2009 and looked for PABSI occurrence before May 1st, 2011 to define cases. Thirty nine PABSI occurred in this population with an attack rate of 5.8%. We estimated an incidence rate of 0.08/1000 PAC-days using the case-control study. PABSI causative agents were mainly Gram positive cocci (62%). We identified three predictive factors of PABSI by multivariate statistical analysis: neutropenia on outcome date (Odds Ratio [OR]: 4.05; 95% confidence interval [CI]:1.05- 15.66; p=0.042), diabetes (OR: 11.53; 95% CI: 1.07-124.70; p=0.044) and having another infection than PABSI on outcome date (OR: 6.35; 95% CI: 1.50-26.86; p=0.012). Patients suffering from acute or renal failure (OR: 4.26; 95% CI: 0.94-19.21; p=0.059) or wearing another invasive device (OR: 2.99; 95%CI:0.96-9.31; p=0.059) did not have a statistically increased risk for developing a PABSI according to classical threshold (p<0.05) but nevertheless remained close to significance. Our study demonstrated that local epidemiology and microbiology of PABSI in our institution was similar to previous reports. A larger prospective study is required to confirm our results or to test preventive measures.
Resumo:
PURPOSE: To test the ability of two preparations of FGF2-saporin, either FGF2 chemically conjugated to saporin (FGF2-SAP) or genetically engineered FGF2-saporin (rFGF2-SAP) to inhibit the growth of bovine epithelial lens (BEL) cells in vitro when in solution and when immobilized on heparin surface-modified (HSM) polymethylmethacrylate (PMMA) intraocular lenses (IOLs). METHOD: Bovine epithelial lens cells were incubated with various concentrations FGF2-saporin for as long as 4 days. The number of surviving cells was determined by counting the number of nuclei. Because FGF2 binds to heparin, FGF2-saporin was incubated with HSM PMMA IOLs; excess toxin was washed off, and the BEL cells were grown on the FGF2-saporin-treated IOLs (HSM and non-HSM) for 4 days. Cell density was determined by image analysis. RESULTS: Both FGF2-SAP and rFGF2-SAP were highly cytotoxic (nM range), with rFGF2-SAP 10 times less active than FGF2-SAP. FGF2-saporin bound to the surface of HSM IOLs and eluted by 2M NaCl retained its activity. Toxin bound to HSM IOLs killed more than 90% of the BEL cells placed on the IOL surface within 4 days. The ability of FGF2-saporin to prevent the growth of cells on the IOL surface was strictly dependent on the presence of heparin on the IOL. CONCLUSIONS: FGF2-saporin is bound to HSM PMMA IOLs and prevents the growth of epithelial cells on the surface of the lens.
Resumo:
Objective: Although 24-hour arterial blood pressure can be monitored in a free-moving animal using pressure telemetric transmitter mostly from Data Science International (DSI), accurate monitoring of 24-hour mouse left ventricular pressure (LVP) is not available because of its insufficient frequency response to a high frequency signal such as the maximum derivative of mouse LVP (LVdP/dtmax and LVdP/dtmin). The aim of the study was to develop a tiny implantable flow-through LVP telemetric transmitter for small rodent animals, which can be potentially adapted for human 24 hour BP and LVP accurate monitoring. Design and Method: The mouse LVP telemetric transmitter (Diameter: _12 mm, _0.4 g) was assembled by a pressure sensor, a passive RF telemetry chip, and to a 1.2F Polyurethane (PU) catheter tip. The device was developed in two configurations and compared with existing DSI system: (a) prototype-I: a new flow-through pressure sensor with wire link and (b) prototype-II: prototype-I plus a telemetry chip and its receiver. All the devices were applied in C57BL/6J mice. Data are mean_SEM. Results: A high frequency response (>100 Hz) PU heparin saline-filled catheter was inserted into mouse left ventricle via right carotid artery and implanted, LV systolic pressure (LVSP), LVdP/dtmax, and LVdP/dtmin were recorded on day2, 3, 4, 5, and 7 in conscious mice. The hemodynamic values were consistent and comparable (139_4 mmHg, 16634_319, - 12283_184 mmHg/s, n¼5) to one recorded by a validated Pebax03 catheter (138_2mmHg, 16045_443 and -12112_357 mmHg/s, n¼9). Similar LV hemodynamic values were obtained with Prototype-I. The same LVP waveforms were synchronically recorded by Notocord wire and Senimed wireless software through prototype-II in anesthetized mice. Conclusion: An implantable flow-through LVP transmitter (prototype-I) is generated for LVP accurate assessment in conscious mice. The prototype-II needs a further improvement on data transmission bandwidth and signal coupling distance to its receiver for accurate monitoring of LVP in a freemoving mouse.
Resumo:
Implantation of a phakic iris claw intraocular lens is a common, effective and safe procedure to correct high myopia, hyperopia and astigmatism [2]. Due to the nature of its fixation on the iris using claws, chronic irritation and inflammation have remained a major concern with the Artisan® lens since its market introduction in 1998. Following iris claw implantation, monitoring of postoperative inflammation is mandatory [4][7]. Usually, signs of inflammation can be detected in the anterior chamber during the early postoperative period. We present here the first case of late-onset inflammation after implantation of an iris claw lens triggered by an iris varix. The iris varix is a rare benign iris vascular abnormality, with a low prevalence as a solitary primary lesion in the general population and little is known about its clinical characteristics [1][5][6]. This report shows that an iris varix could be a cause of a late onset and chronic inflammation after phakic Artisan® lens implantation.
Resumo:
The main aim of the Work Package 1 (WP1) of the ORAMED project, Collaborative Project (2008-2011), supported by the European Commission within its 7th Framework Programme, was to obtain a set of standardized data on extremity and eye lens doses for staff in interventional radiology and cardiology (IR/IC) workplaces and to recommend a series of guidelines on radiation protection in order to both guarantee and optimize staff protection. Within the project, coordinated measurements were performed in 34 hospitals in 6 European countries. Furthermore, simulations of the most representative workplaces in IR and IC were performed to determine the main parameters that influence the extremity and eye lens doses. The work presented in this paper shows the recommendations that were formulated by the results obtained from both measurements and simulations. The presented guidelines are directed to operators, assistant personnel, radiation protection officers and medical physics experts. They concern radiation protection issues, such as the use of room protective equipment, as well as the positioning of the extremity and eye lens dosemeters for routine monitoring.
Resumo:
PURPOSE: To investigate the ability of fibroblast growth factor (FGF) 2-saporin to prevent lens regrowth in the rabbit. METHODS: Chemically conjugated and genetically fused FGF2-saporin (made in Escherichia coli) were used. Extracapsular extraction of the lens was performed on the rabbit, and the cytotoxin either was injected directly into the capsule bag or was administered by FGF2-saporin-coated, heparin surface-modified (HSM) polymethylmethacrylate intraocular lenses. The potential of the conjugate was checked by slit lamp evaluation of capsular opacification and by measuring crystallin synthesis. Toxin diffusion and sites of toxin binding were assessed by immunohistochemistry. Possible toxicity was determined by histologic analysis of ocular tissues. RESULTS: FGF2-saporin effectively inhibited lens regrowth when it was injected directly into the capsular bag. However, high concentration of the toxin induced transient corneal edema and loss of pigment in the iris. Intraocular lenses coated with FGF2-saporin reduced lens regrowth and crystallin synthesis without any detectable clinical side effect. After implantation, FGF2-saporin was shown to have bound to the capsules and, to a lesser extent, to the iris; no histologic damage was found on ocular tissues as a result of implantation of drug-loaded HSM intraocular lenses. CONCLUSIONS: Chemically conjugated (FGF2-SAP) and genetically fused FGF2-saporin (rFGF2-SAP) bound to HSM intraocular lenses can prevent lens regrowth in the rabbit.
Resumo:
Purpose: In vitro studies in porcine eyes have demonstrated a good correlation between induced intraocular pressure variations and corneal curvature changes, using a contact lens with an embedded microfabricated strain gauge. Continuous 24 hour-intraocular pressure (IOP) monitoring to detect large diurnal fluctuation is currently an unmet clinical need. The aims of this study is to evaluate precision of signal transmission and biocompatibility of 24 hour contact lens sensor wear (SENSIMED Triggerfish®) in humans. Methods: After full eye examination in 10 healthy volunteers, a 8.7 mm radius contact lens sensor and an orbital bandage containing a loop antenna were applied and connected to a portable recorder. Best corrected visual acuity and position, lubrication status and mobility of the sensor were assessed after 5 and 30 minutes, 4, 7 and 24 hours. Subjective comfort was scored and activities documented in a logbook. After sensor removal full eye examination was repeated, and the registration signal studied. Results: The comfort score was high and did not fluctuate significantly, except at the 7 hour-visit. The mobility of the contact lens was minimal but its lubrication remained good. Best corrected visual acuity was significantly reduced during the sensor wear and immediately after its removal. Three patients developed mild corneal staining. In all but one participant we obtained a registration IOP curve with visible ocular pulse amplitude. Conclusions: This 24 hour-trial confirmed the functionality and biocompatibility of SENSIMED Triggerfish® wireless contact lens sensor for IOP-fluctuation monitoring in volunteers. Further studies with a range of different contact lens sensor radii are indicated.
Resumo:
Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.
Resumo:
Starting from the early descriptions of Kraepelin and Bleuler, the construct of schizotypy was developed from observations of aberrations in nonpsychotic family members of schizophrenia patients. In contemporary diagnostic manuals, the positive symptoms of schizotypal personality disorder were included in the ultra high-risk (UHR) criteria 20 years ago, and nowadays are broadly employed in clinical early detection of psychosis. The schizotypy construct, now dissociated from strict familial risk, also informed research on the liability to develop any psychotic disorder, and in particular schizophrenia-spectrum disorders, even outside clinical settings. Against the historical background of schizotypy it is surprising that evidence from longitudinal studies linking schizotypy, UHR, and conversion to psychosis has only recently emerged; and it still remains unclear how schizotypy may be positioned in high-risk research. Following a comprehensive literature search, we review 18 prospective studies on 15 samples examining the evidence for a link between trait schizotypy and conversion to psychosis in 4 different types of samples: general population, clinical risk samples according to UHR and/or basic symptom criteria, genetic (familial) risk, and clinical samples at-risk for a nonpsychotic schizophrenia-spectrum diagnosis. These prospective studies underline the value of schizotypy in high-risk research, but also point to the lack of evidence needed to better define the position of the construct of schizotypy within a developmental psychopathology perspective of emerging psychosis and schizophrenia-spectrum disorders.
Resumo:
Mise au point sur le hotter implantable (Reveal®). Connaissances actuelles et implications thérapeutiques. La syncope est un problème fréquent touchant environ un tiers des adultes durant leur vie. C'est un motif de consultation habituel aux urgences et ses causes sont souvent multiples et rendent son diagnostic difficile. Malgré des investigations extensives et coûteuses la cause syncopale reste dans environ 30% des cas d'étiologie indéterminée. Les progrès récents dans le monitoring cardiaque à long terme ont permis d'inclure dans le choix des tests diagnostiques un outil très intéressant dans l'investigation de la syncope d'étiologie indéterminée (SOI). Il s'agit du moniteur ECG implantable (MEI) ou Reveal®. Il y a un peu plus de 10 ans un prototype de MEI a été implanté dans un petit collectif de patients souffrants de SOI récidivantes et a permis d'établir un diagnostic chez la plupart d'entre eux. Dès lors le système s'est modernisé avec une diminution importante de la taille et du poids permettant actuellement d'enregistrer le rythme cardiaque sur une durée de 18 à 24 mois. Le système peut stocker dans sa mémoire un tracé ECG soit à l'aide d'un activateur externe déclenché par le patient, soit de façon spontanée en présence d'un rythme cardiaque lent ou rapide. Son implantation se fait en anesthésie locale, en position sous-cutanée pectorale gauche. Les complications et les problèmes infectieux sont rares. Plusieurs études récentes se sont intéressées à l'apport diagnostique du MEI dans la prise en charge de la SOI. La plus grande porte sur un collectif de 206 patients. L'apport diagnostique des différentes études varie de 40% à 64%. Cependant la plupart de ces études ne comportaient pas de prise en charge standardisée ou avaient des critères d'inclusion précis. Nous nous sommes intéressés aux résultats de notre prise en charge de la syncope au cours de ces 6 dernières années. Une consultation spécialisée de la syncope a été mise en place en 1999. La consultation offre l'accès à tout le plateau technique propre à l'investigation de syncopes à savoir un tilt-test avec mesure continue non invasive de la pression artérielle, examens échocardiographiques et test d'effort. Si nécessaire, le bilan peut être complété par une étude électrophysiologique (EEP) et/ou une coronarographie: Tous les patients bénéficient d'une anamnèse ciblée suivi d'un examen clinique et d'un électrocardiogramme. Une échocardiographie n'est effectuée qu'en cas de suspicion de cardiopathie sous-jacente. Un holter ou R-test ne sont réalisés qu'en présence de syncopes ou palpitations fréquentes. Les investigations se poursuivent par un tilt test suivi d'un massage du sinus carotidien en position debout et couchée. Un test d'hyperventilation n'est pratiqué que chez les patients avec traits phobiques, dépressifs ou troubles de type panique. L'EEP n'est pratiquée que chez les patients dont la syncope reste d'étiologie indéterminée après investigations initiales et chez ceux souffrant d'une cardiopathie sous jacente documentée ; elle est aussi indiquée chez ceux dont le coeur est normal mais chez qui la syncope est associée à des traumatismes ou à l'origine d'un accident de voiture. Le MEI est proposé lorsque toutes les investigations initiales restent négatives, généralement chez les sujets ayant souffert de plus d'une syncope ou de complications sérieuses. Notre expérience pratique d'une consultation de la syncope ouverte au tout venant nous montre qu'une prise en charge standardisée non invasive permet d'identifier une cause syncopale chez plus de 60% des patients. Chez les patients souffrant de syncopes récidivantes ou traumatiques d'étiologie indéterminée après investigations conventionnelles, l'apport diagnostique du MEI est élevé (64%) durant un suivi moyen de 9 mois, ce qui permet d'identifier certaines causes syncopales écartées précédemment par des tests ciblés. Parmi ces dernières, retenons plus particulièrement les tachycardies nodales et crises d'épilepsie.