104 resultados para IMPLANT-SUPPORTED FIXED PROSTHESIS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The risk that hip preserving surgery may negatively influence the performance and outcome of subsequent total hip replacement (THR) remains a concern. The aim of this study was to identify any negative impact of previous hip arthroscopy on THR. METHODS: Out of 1271 consecutive patients who underwent primary THR between 2005 and 2009, 18 had previously undergone ipsilateral hip arthroscopy. This study group (STG) was compared with two control groups (CG, same approach, identical implants; MCG, paired group matched for age, BMI and Charnley categories). Operative time, blood loss, evidence of heterotopic bone and implant loosening at follow-up were compared between the STG and the MCG. Follow-up WOMAC were compared between the three groups. RESULTS: Blood loss was not found to be significantly different between the STG and MCG. The operative time was significantly less (p < 0.001) in the STG. There was no significant difference in follow-up WOMAC between the groups. No implant related complications were noted in follow-up radiographs. Two minor complications were documented for the STG and three for the MCG. CONCLUSION: We have found no evidence that previous hip arthroscopy negatively influences the performance or short-term clinical outcome of THR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Aims: Two distinct e ndoscopic phenotypes of E osinophilic Esophagitis (EoE) h ave been identified: t he inflammatory (IP) a nd the stenosing (SP) p henotype. I t is not known whether these EoE-associated phenotypes are reflective of different phases during disease course. We aimed to assess the phenotype a t initial EoE p resentation and d iagnosis and to evaluate if SP increases over time. Methods: R etrospective a nalysis of t he Swiss EoE Database (SEED) extended b y a review of p atients charts, endoscopy and pathology records. Results: F orty-four E oE p atients were a nalyzed (33 males, mean age at index visit 41 ± 14 years, all Caucasians). Median follow-up t ime was 3.1 years (IQR 1-4, r ange 1 -18 years). Median diagnostic delay w as 5 y ears (IQR 2-16, range 0-34 years). A t first diagnosis, 3 2% ( 14/44) o f EoE patients h ad already presented w ith a stenosis. T he mean d iameter o f the stenoses w as 1 0 ± 2 mm, and the mean length was 2 .8 ± 2 .9 cm. Peak e osinophil count d id n ot c hange over t ime (48 ± 39 eos/HPF at index visit vs. 59 ± 41 eos/HPF at end of follow-up, n=44). The risk of the presence of a stenosis at index visit was 0% f or a d isease duration of 0 -4 y ears, 37% f or a d isease duration between 5-10 years and 67% f or a d isease duration >10 years (p = 0.0035, trend test). Conclusions: T he frequency of e sophageal stenoses i s proportional to the disease duration, whereas the inflammatory activity does n ot s ignificantly c hange over t ime. O ur f indings underscore the necessity to reduce diagnostic delay in EoE and to control the underlying inflammatory processes to prevent esophageal remodeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: We investigate a new heat delivery technique for the local treatment of solid tumors. The technique involves injecting a formulation that solidifies to form an implant in situ. This implant entraps superparamagnetic iron oxide nanoparticles (SPIONs) embedded in silica microbeads for magnetically induced moderate hyperthermia. Particle entrapment prevents phagocytosis and distant migration of SPIONs. The implant can be repeatedly heated by magnetic induction. Methods: We evaluated heating and treatment efficacies by means of thermometry and survival studies in nude mice carrying subcutaneous human colocarcinomas. At day 1, we injected the formulation into the tumor. At day 2, a single 20-min hyperthermia treatment was delivered by 141-kHz magnetic induction using field strengths of 9 to 12 mT under thermometry. Results: SPIONs embedded in silica microbeads were effectively confined within the implant at the injection site. Heat-induced necro-apoptosis was assessed by histology on day 3. On average, 12 mT resulted in tumor temperature of 47.8 degrees C, and over 70% tumor necrosis that correlated to the heat dose (AUC = 282 degrees C.min). In contrast, a 9-mT field strength induced tumoral temperature of 40 degrees C (AUC = 131 degrees C.min) without morphologically identifiable necrosis. Survival after treatment with 10.5 or 12 mT fields was significantly improved compared to non-implanted and implanted controls. Median survival times were 27 and 37 days versus 12 and 21 days respectively. Conclusion: Five of eleven mice (45%) of the 12 mT group survived one year without any tumor recurrence, holding promise for tumor therapy using magnetically induced moderate hyperthermia through injectable implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study verifies whether cochlear implants helps deaf adults to maintain or develop their professional occupations. Sixty-seven patients received a questionnaire concerning their professional activities before and after implantation. At the time of implantation 34 were professionally active. After the implantation 29 remained active, 4 of them reporting positive developments in their careers. Five patients became inactive. The previously inactive patients remained inactive. There was no difference in auditory performances between professionally active or inactive patients. Cochlear implants enable most implanted adults to maintain and even progress in their professions. However, deafness still represents an obstacle to social integration as inactive patients who searched for a job were rejected after the job interviews.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: All patients with extensive resection of the anterolateral chest wall and the sternum followed by reconstruction with methylmethacrylate substitutes were assessed prospectively 6 months after the operation to delineate chest wall integrity with pulmonary function and cine-magnetic resonance imaging. METHODS: Twenty-six patients underwent chest wall reconstruction by use of methylmethacrylate between 1994 and 1998 due to primary tumors in 35%, metastases in 27%, T3 lung cancer in 19%, and debridement for radionecrosis and osteomyelitis in 19% of patients. Three to eight ribs were resected and additional sternum resection was performed in 39% of patients. RESULTS: There was no 30-day mortality. All patients were extubated after the operation without need for reintubation. Prosthesis dislocation occurred in 1 patient and infection in 2 patients during follow-up. Nineteen patients (73%) suffered no restrictions of daily activities. Clinical examination revealed normal shoulder girdle function in 77% of patients. There was no significant difference between preoperative and postoperative FEV1 (forced expiratory volume in 1 second) measurements in patients with lobectomy or wedge resections. Cinemagnetic resonance imaging revealed concordant chest wall movements during respiration in 92% of patients without paradoxical movements or implant dislocations being observed. CONCLUSIONS: Large defects of the anterolateral chest wall and sternum can be reconstructed efficiently with methylmethacrylate substitutes with minimal morbidity and excellent cosmetic and functional outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of Propionibacterium acnes in acne and in a wide range of inflammatory diseases is well established. However, P. acnes is also responsible for infections involving implants. Prolonged aerobic and anaerobic agar cultures for 14 days and broth cultures increase the detection rate. In this paper, we review the pathogenic role of P. acnes in implant-associated infections such as prosthetic joints, cardiac devices, breast implants, intraocular lenses, neurosurgical devices, and spine implants. The management of severe infections caused by P. acnes involves a combination of antimicrobial and surgical treatment (often removal of the device). Intravenous penicillin G and ceftriaxone are the first choice for serious infections, with vancomycin and daptomycin as alternatives, and amoxicillin, rifampicin, clindamycin, tetracycline, and levofloxacin for oral treatment. Sonication of explanted prosthetic material improves the diagnosis of implant-associated infections. Molecular methods may further increase the sensitivity of P. acnes detection. Coating of implants with antimicrobial substances could avoid or limit colonization of the surface and thereby reduce the risk of biofilm formation during severe infections. Our understanding of the role of P. acnes in human diseases will likely continue to increase as new associations and pathogenic mechanisms are discovered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:  Study in vivo characteristics of a polymethylmethacrylate (PMMA) implant compared to the standard cylindrical collagen implant for deep sclerectomy (DS). Design:  Six-month comparative study. Samples:  Twenty eyes of ten rabbits. Methods:  Eyes were randomized to have DS with PMMA implant in one eye and collagen implant in the opposite eye. The growth of the new subconjunctival drainage vessels was assessed by combined fluorescein and indocyanin green anterior segment angiography; intrascleral and subconjunctival blebs were imaged by ultrasound biomicroscopy (UBM). At six months, outflow facility (C) was measured by anterior chamber perfusion and portions of one side of the DS were compared to portions on the 180° opposite side and native sclera on histology. Results:  The mean IOP preoperatively and at one, four, twelve, and twenty-four weeks was comparable in both groups (P > 0.1). UBM showed a statistically insignificant quicker regression of the subconjunctival bleb as well as a durable intrascleral lake in the PMMA group (P > 0.05). New drainage vessels were initially observed one month after surgery; they were more numerous in the PMMA group on angiographic and histological findings at 6 months (P < 0.05). The mean C increased significantly after surgery compared to preoperative values (P < 0.05) and no difference was observed between the implants (0.24 ± 0.06 µl/min/mmHg [PMMA] and 0.23 ± 0.07 µl/min/mmHg [collagen implant]) (P = 0.39). Conclusions:  Deep sclerectomy performed with PMMA or collagen implants showed similar IOP lowering effects, outflow facility increase, and degree of inflammatory reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial hypertension is a highly heterogeneous condition. It is therefore not surprising that blood pressure lowering agents acting via a given mechanism allow a normalization of blood pressure in a fraction of hypertensive subjects only. The combination of drugs with different mechanisms of action on the cardiovascular system results in a considerably higher antihypertensive efficacy, not only with regard to the absolute blood pressure reduction but also in the number of responders. This effect is not achieved at the expenses of tolerance, because usually lower doses of the combined agents are sufficient to achieve the target blood pressure. The administration of antihypertensive agents in fixed combination has the advantage of its simplicity for both the physician as well as the patient. This aspect also explains the increasing popularity of fixed combinations as a valuable option in the initial treatment of the hypertensive patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. Methods: This randomized controlled double-blind study included to date 31 patients: the gait signatures of 12 patients with mobile-bearing were compared to the gait signatures of 19 patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. Results: Better relative differences between pre-operative and post-operative 3 months and 6 months KSS (122% vs 34% at 3 months, 138% vs 36% at 6 months) and KSS function (154% vs 8% at 3 months, 183% vs 42% at 6 months) scores were observed for the fixed-bearing compared to the mobile-bearing. The same better improvements for fixed-bearing were also found with the range of knee angles (Affected side: 31% vs -5% at 3 months, 47% vs 5% at 6 months), (Unaffected side: 16% vs 5% at 3 months, 15% vs 6% at 6 months) and peak swing speeds of shank (Affected side: 18% vs -2% at 3 months, 30% vs 4% at 6 months), (Unaffected side: 8% vs -3% at 3 months, 7% vs 4% at 6 months). Conclusions: A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total ankle replacement remains a less satisfactory solution compared to other joint replacements. The goal of this study was to develop and validate a finite element model of total ankle replacement, for future testing of hypotheses related to clinical issues. To validate the finite element model, an experimental setup was specifically developed and applied on 8 cadaveric tibias. A non-cemented press fit tibial component of a mobile bearing prosthesis was inserted into the tibias. Two extreme anterior and posterior positions of the mobile bearing insert were considered, as well as a centered one. An axial force of 2kN was applied for each insert position. Strains were measured on the bone surface using digital image correlation. Tibias were CT scanned before implantation, after implantation, and after mechanical tests and removal of the prosthesis. The finite element model replicated the experimental setup. The first CT was used to build the geometry and evaluate the mechanical properties of the tibias. The second CT was used to set the implant position. The third CT was used to assess the bone-implant interface conditions. The coefficient of determination (R-squared) between the measured and predicted strains was 0.91. Predicted bone strains were maximal around the implant keel, especially at the anterior and posterior ends. The finite element model presented here is validated for future tests using more physiological loading conditions.