50 resultados para Human performance


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sensitive and specific ultra performance liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of nicotine, its metabolites cotinine and trans-3'-hydroxycotinine and varenicline in human plasma was developed and validated. Sample preparation was realized by solid phase extraction of the target compounds and of the internal standards (nicotine-d4, cotinine-d3, trans-3'-hydroxycotinine-d3 and CP-533,633, a structural analog of varenicline) from 0.5mL of plasma, using a mixed-mode cation exchange support. Chromatographic separations were performed on a hydrophilic interaction liquid chromatography column (HILIC BEH 2.1×100mm, 1.7μm). A gradient program was used, with a 10mM ammonium formate buffer pH 3/acetonitrile mobile phase at a flow of 0.4mL/min. The compounds were detected on a triple quadrupole mass spectrometer, operated with an electrospray interface in positive ionization mode and quantification was performed using multiple reaction monitoring. Matrix effects were quantitatively evaluated with success, with coefficients of variation inferior to 8%. The procedure was fully validated according to Food and Drug Administration guidelines and to Société Française des Sciences et Techniques Pharmaceutiques. The concentration range was 2-500ng/mL for nicotine, 1-1000ng/mL for cotinine, 2-1000ng/mL for trans-3'-hydroxycotinine and 1-500ng/mL for varenicline, according to levels usually measured in plasma. Trueness (86.2-113.6%), repeatability (1.9-12.3%) and intermediate precision (4.4-15.9%) were found to be satisfactory, as well as stability in plasma. The procedure was successfully used to quantify nicotine, its metabolites and varenicline in more than 400 plasma samples from participants in a clinical study on smoking cessation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Angiotensin II (Ang II) is one of the most potent vasoconstrictors. We document here the innervation of rat and human mesenteric resistance arteries (MRA) by angiotensinergic neurons of the rat and human sympathetic coeliac ganglia. Angiotensinogen (Ang-N)-mRNA and angiotensin converting enzyme-mRNA but no renin-mRNA were detected by using quantitative real time polymerase chain reaction in total RNA extracts of rat coeliac ganglia. In the same extracts, cathepsin D-mRNA was detected: This protease also cleaves Ang I from Ang-N and could therefore account for the generation of neuronal Ang peptides in the absence of renin. In situ hybridization confirmed the presence of Ang-N-mRNA in the cytoplasm of rat coeliac ganglia. By using solid-phase extraction, high performance liquid chromatography and subsequent radioimmunoassay, Ang II and its metabolites were detected in rat and also in human coeliac ganglia. Immunoreactivity for Ang II was demonstrated in rat and human coeliac ganglia neurons and their projections innervating MRA. In addition, segmental angiotensinergic innervation of MRA was also observed. By means of confocal laser scanning microscopy we were able to demonstrate the presence of angiotensinergic synapses en passant along side of vascular smooth muscle cells. Our findings could indicate that Ang II is synthesized inside the neurons of sympathetic coeliac ganglia and may act as an endogenous neurotransmitter locally in MRA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate a transverse electromagnetic (TEM), a circularly polarized (CP) (birdcage), and a 12-channel phased array head coil at the clinical field strength of B0 = 3T in terms of signal-to-noise ratio (SNR), signal homogeneity, and maps of the effective flip angle alpha. MATERIALS AND METHODS: SNR measurements were performed on low flip angle gradient echo images. In addition, flip angle maps were generated for alpha(nominal) = 30 degrees using the double angle method. These evaluation steps were performed on phantom and human brain data acquired with each coil. Moreover, the signal intensity variation was computed for phantom data using five different regions of interest. RESULTS: In terms of SNR, the TEM coil performs slightly better than the CP coil, but is second to the smaller 12-channel coil for human data. As expected, both the TEM and the CP coils show superior image intensity homogeneity than the 12-channel coil, and achieve larger mean effective flip angles than the combination of body and 12-channel coil with reduced radio frequency power deposition. CONCLUSION: At 3T the benefits of TEM coil design over conventional lumped element(s) coil design start to emerge, though the phased array coil retains an advantage with respect to SNR performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE: The aim of the work was to develop and validate a method for the quantification of vitamin D metabolites in serum using ultra-high-pressure liquid chromatography coupled to mass spectrometry (LC/MS), and to validate a high-resolution mass spectrometry (LC/HRMS) approach against a tandem mass spectrometry (LC/MS/MS) approach using a large clinical sample set. METHODS: A fast, accurate and reliable method for the quantification of the vitamin D metabolites, 25-hydroxyvitamin D2 (25OH-D2) and 25-hydroxyvitamin D3 (25OH-D3), in human serum was developed and validated. The C3 epimer of 25OH-D3 (3-epi-25OH-D3) was also separated from 25OH-D3. The samples were rapidly prepared via a protein precipitation step followed by solid-phase extraction (SPE) using an HLB μelution plate. Quantification was performed using both LC/MS/MS and LC/HRMS systems. RESULTS: Recovery, matrix effect, inter- and intra-day reproducibility were assessed. Lower limits of quantification (LLOQs) were determined for both 25OH-D2 and 25OH-D3 for the LC/MS/MS approach (6.2 and 3.4 µg/L, respectively) and the LC/HRMS approach (2.1 and 1.7 µg/L, respectively). A Passing & Bablok fit was determined between both approaches for 25OH-D3 on 662 clinical samples (1.11 + 1.06x). It was also shown that results can be affected by the inclusion of the isomer 3-epi-25OH-D3. CONCLUSIONS: Quantification of the relevant vitamin D metabolites was successfully developed and validated here. It was shown that LC/HRMS is an accurate, powerful and easy to use approach for quantification within clinical laboratories. Finally, the results here suggest that it is important to separate 3-epi-25OH-D3 from 25OH-D3. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The recently released Affymetrix Human Gene 1.0 ST array has two major differences compared with standard 3' based arrays: (i) it interrogates the entire mRNA transcript, and (ii) it uses DNA targets. To assess the impact of these differences on array performance, we performed a series of comparative hybridizations between the Human Gene 1.0 ST and the Affymetrix HG-U133 Plus 2.0 and the Illumina HumanRef-8 BeadChip arrays. Additionally, both RNA and DNA targets were hybridized on HG-U133 Plus 2.0 arrays. The results show that the overall reproducibility of the Gene 1.0 ST array is best. When looking only at the high intensity probes, the reproducibility of the Gene 1.0 ST array and the Illumina BeadChip array is equally good. Concordance of array results was assessed using different inter-platform mappings. Agreements are best between the two labeling protocols using HG-U133 Plus 2.0 array. The Gene 1.0 ST array is most concordant with the HG-U133 array hybridized with cDNA targets. This may reflect the impact of the target type. Overall, the high degree of correspondence provides strong evidence for the reliability of the Gene 1.0 ST array.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The photodynamic effects of m-tetrahydroxyphenylchlorin (mTHPC) were assessed on human malignant mesothelioma, squamous cell carcinoma and adenocarcinoma xenografts grown in nude mice and were correlated with mTHPC uptake, histology and doubling time of the tumors. Non-thermal laser light was delivered to the tumor as surface radiation 4 days after intraperitoneal administration of 0.1 and 0.3 mg mTHPC/kg body weight, respectively. The extent of tumor necrosis was measured by histomorphometry. The mTHPC concentration in non-irradiated tumors was assessed by high-performance liquid chromatography (HPLC). The tumors were graded according to their doubling time and their vascular architecture as assessed by histology. The 0.1 mg/kg dose of mTHPC resulted in an equal uptake for all 3 tumor types but revealed a larger extent of photosensitized necrosis for adenocarcinoma, which displayed a delicate tumor stroma with numerous small capillary vessels, than for mesothelioma and squamous cell carcinoma, which were both poor in stroma and vessels. The 0.3 mg/kg dose of mTHPC resulted in a 2-fold higher tumor uptake for all 3 tumor types and in a larger extent of necrosis for mesothelioma and squamous cell carcinoma, but not for adenocarcinoma xenografts, compared with the lower drug dose. Our results demonstrate that different tumor xenografts respond differently to mTHPC-PDT for a given drug-light condition. In this setting, the photosensitizing effect was more closely related to the vascular architecture of the tumors than to the sensitizer uptake and doubling time of the different tumors

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Surgeons' personalities have been described as different from those of the general population, but this was based on small descriptive studies limited by the choice of evaluation instrument. Furthermore, although the importance of the human factor in team performance has been recognized, the effect of personality traits on technical performance is unknown. This study aimed to compare surgical residents' personality traits with those of the general population and to evaluate whether an association exists between their personality traits and technical performance using a virtual reality (VR) laparoscopy simulator. METHODS: In this study, 95 participants (54 residents with basic, 29 with intermediate laparoscopic experience, and 12 students) underwent personality assessment using the NEO-Five Factor Inventory and performed five VR tasks of the Lap Mentor? basic tasks module. The residents' personality traits were compared with those of the general population, and the association between VR performance and personality traits was investigated. RESULTS: Surgical residents showed personality traits different from those of the general population, demonstrating lower neuroticism, higher extraversion and conscientiousness, and male residents showed greater openness. In the multivariable analysis, adjusted for gender and surgical experience, none of the personality traits was found to be an independent predictor of technical performance. CONCLUSIONS: Surgical residents present distinct personality traits that differ from those of the general population. These traits were not found to be associated with technical performance in a virtual environment. The traits may, however, play an important role in team performance, which in turn is highly relevant for optimal surgical performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neuromotor functioning - i.e., timed performance and quality of movements - was examined in 66 left-handed children and adolescents between 5 and 18.5 years by means of the Zurich Neuromotor Assessment. Quality of movements was assessed by the degree and the frequency of associated movements. Results were compared to normative data from 593 right-handers. The overall scores for timed motor performance were similar for left-handers and right-handers, while left-handers had more associated movements than right-handers with both sides. In agreement with previous studies in adults, we found that left-handed children were less lateralized than right-handers. They performed faster with their non-dominant side and slower with their dominant side. This finding was roughly independent of age, which may indicate that handedness does not reflect long-term effects of previous motor experience, but may be primarily attributed to genetic factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The most evident symptoms of schizophrenia are severe impairment of cognitive functions like attention, abstract reasoning and working memory. The latter has been defined as the ability to maintain and manipulate on-line a limited amount of information. Whereas several studies show that working memory processes are impaired in schizophrenia, the specificity of this deficit is still unclear. Results obtained with a new paradigm, involving visuospatial, dynamic and static working memory processing, suggest that schizophrenic patients rely on a specific compensatory strategy. An animal model of schizophrenia with a transient deficit in glutathione during the development reveals similar substitutive processing, masking the impairment in working memory functions in specific test conditions only. Taken together, these results show coherence between working memory deficits in schizophrenic patients and in animal models. More generally, it is possible to consider that the pathological state may be interpreted as a reduced homeostatic reserve. However, this may be balanced in specific situations by efficient allostatic strategies. Thus, the pathological condition would remain latent in several situations, due to such allostatic regulations. However, to maintain a performance based on highly specific strategies requires in turn specific conditions, limitating adaptative resources in humans and in animals. In summary, we suggest that the psychological and physical load to maintain this rigid allostatic state is very high in patients and animal subjects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Inhibitory control refers to the ability to suppress planned or ongoing cognitive or motor processes. Electrophysiological indices of inhibitory control failure have been found to manifest even before the presentation of the stimuli triggering the inhibition, suggesting that pre-stimulus brain-states modulate inhibition performance. However, previous electrophysiological investigations on the state-dependency of inhibitory control were based on averaged event-related potentials (ERPs), a method eliminating the variability in the ongoing brain activity not time-locked to the event of interest. These studies thus left unresolved whether spontaneous variations in the brain-state immediately preceding unpredictable inhibition-triggering stimuli also influence inhibitory control performance. To address this question, we applied single-trial EEG topographic analyses on the time interval immediately preceding NoGo stimuli in conditions where the responses to NoGo trials were correctly inhibited [correct rejection (CR)] vs. committed [false alarms (FAs)] during an auditory spatial Go/NoGo task. We found a specific configuration of the EEG voltage field manifesting more frequently before correctly inhibited responses to NoGo stimuli than before FAs. There was no evidence for an EEG topography occurring more frequently before FAs than before CR. The visualization of distributed electrical source estimations of the EEG topography preceding successful response inhibition suggested that it resulted from the activity of a right fronto-parietal brain network. Our results suggest that the fluctuations in the ongoing brain activity immediately preceding stimulus presentation contribute to the behavioral outcomes during an inhibitory control task. Our results further suggest that the state-dependency of sensory-cognitive processing might not only concern perceptual processes, but also high-order, top-down inhibitory control mechanisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Oseltamivir phosphate (OP), the prodrug of oseltamivir carboxylate (OC; active metabolite), is marketed since 10 years for the treatment of seasonal influenza flu. It has recently received renewed attention because of the threat of avian flu H5N1 in 2006-7 and the 2009-10 A/H1N1 pandemic. However, relatively few studies have been published on OP and OC clinical pharmacokinetics. The disposition of OC and the dosage adaptation of OP in specific populations, such as young children or patients undergoing extrarenal epuration, have also received poor attention. An analytical method was thus developed to assess OP and OC plasma concentrations in patients receiving OP and presenting with comorbidities or requiring intensive care. Methods: A high performance liquid chromatography coupled to tandem mass spectrometry method (HPLC-MS/MS) requiring 100-µL aliquot of plasma for quantification within 6 min of OP and OC was developed. A combination of protein precipitation with acetonitrile, followed by dilution of supernant in suitable buffered solvent was used as an extraction procedure. After reverse phase chromatographic separation, quantification was performed by electro-spray ionization-triple quadrupole mass spectrometry. Deuterated isotopic compounds of OP and OC were used as internal standards. Results: The method is sensitive (lower limit of quantification: 5 ng/mL for OP and OC), accurate (intra-/inter-assay bias for OP and OC: 8.5%/5.5% and 3.7/0.7%, respectively) and precise (intra-/inter-assay CV%: 5.2%/6.5% and 6.3%/9.2%, respectively) over the clinically relevant concentration range (upper limits of quantification 5000 ng/mL). Of importance, OP, as in other previous reports, was found not to be stable ex vivo in plasma on standard anticoagulants (i.e. EDTA, heparin or citrate). This poor stability of OP has been prevented by collecting blood samples on commercial fluoride/oxalate tubes. Conclusions: This new simple, rapid and robust HPLC-MS/MS assay for quantification of OP and OC plasma concentrations offers an efficient tool for concentration monitoring of OC. Its exposure can probably be controlled with sufficient accuracy by thorough dosage adjustment according to patient characteristics (e.g. renal clearance). The usefulness of systematic therapeutic drug monitoring in patients appears therefore questionable. However, pharmacokinetic studies are still needed to extend knowledge to particular subgroups of patients or dosage regimens.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To clarify the role of Angiotensin II (Ang II) in the sensory system and especially in the trigeminal ganglia, we studied the expression of angiotensinogen (Ang-N)-, renin-, angiotensin converting enzyme (ACE)- and cathepsin D-mRNA, and the presence of Ang II and substance P in the rat and human trigeminal ganglia. The rat trigeminal ganglia expressed substantial amounts of Ang-N- and ACE mRNA as determined by quantitative real time PCR. Renin mRNA was untraceable in rat samples. Cathepsin D was detected in the rat trigeminal ganglia indicating the possibility of existence of pathways alternative to renin for Ang I formation. In situ hybridization in rat trigeminal ganglia revealed expression of Ang-N mRNA in the cytoplasm of numerous neurons. By using immunocytochemistry, a number of neurons and their processes in both the rat and human trigeminal ganglia were stained for Ang II. Post in situ hybridization immunocytochemistry reveals that in the rat trigeminal ganglia some, but not all Ang-N mRNA-positive neurons marked for Ang II. In some neurons Substance P was found colocalized with Ang II. Angiotensins from rat trigeminal ganglia were quantitated by radioimmunoassay with and without prior separation by high performance liquid chromatography. Immunoreactive angiotensin II (ir-Ang II) was consistently present and the sum of true Ang II (1-8) octapeptide and its specifically measured metabolites were found to account for it. Radioimmunological and immunocytochemical evidence of ir-Ang II in neuronal tissue is compatible with Ang II as a neurotransmitter. In conclusion, these results suggest that Ang II could be produced locally in the neurons of rat trigeminal ganglia. The localization and colocalization of neuronal Ang II with Substance P in the trigeminal ganglia neurons may be the basis for a participation and function of Ang II in the regulation of nociception and migraine pathology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A previously developed high performance liquid chromatography mass spectrometry (HPLC-MS) procedure for the simultaneous determination of antidementia drugs, including donepezil, galantamine, memantine, rivastigmine and its metabolite NAP 226-90, was transferred to an ultra performance liquid chromatography system coupled to a tandem mass spectrometer (UPLC-MS/MS). The drugs and their internal standards ([(2)H(7)]-donepezil, [(13)C,(2)H(3)]-galantamine, [(13)C(2),(2)H(6)]-memantine, [(2)H(6)]-rivastigmine) were extracted from 250μL human plasma by protein precipitation with acetonitrile. Chromatographic separation was achieved on a reverse phase column (BEH C18 2.1mm×50mm; 1.7μm) with a gradient elution of an ammonium acetate buffer at pH 9.3 and acetonitrile at a flow rate of 0.4mL/min and an overall run time of 4.5min. The analytes were detected on a tandem quadrupole mass spectrometer operated in positive electrospray ionization mode, and quantification was performed using multiple reaction monitoring. The method was validated according to the recommendations of international guidelines over a calibration range of 1-300ng/mL for donepezil, galantamine and memantine, and 0.2-50ng/mL for rivastimgine and NAP 226-90. The trueness (86-108%), repeatability (0.8-8.3%), intermediate precision (2.3-10.9%) and selectivity of the method were found to be satisfactory. Matrix effects variability was inferior to 15% for the analytes and inferior to 5% after correction by internal standards. A method comparison was performed with patients' samples showing similar results between the HPLC-MS and UPLC-MS/MS procedures. Thus, this validated UPLC-MS/MS method allows to reduce the required amount of plasma, to use a simplified sample preparation, and to obtain a higher sensitivity and specificity with a much shortened run-time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The objective was to explore whether a satellite-based navigation system, global positioning system used in differential mode (DGPS), could accurately assess the speed of running in humans. METHODS: A subject was equipped with a portable GPS receptor coupled to a receiver for differential corrections, while running outdoors on a straight asphalt road at 27 different speeds. Actual speed (reference method) was assessed by chronometry. RESULTS: The accuracy of speed prediction had a standard deviation (SD) of 0.08 km x h(-1) for walking, 0.11 km x h(-1) for running, yielding a coefficient of variation (SD/mean) of 1.38% and 0.82%, respectively. There was a highly significant linear relationship between actual and DGPS speed assessment (r2 = 0.999) with little bias in the prediction equation, because the slope of the regression line was close to unity (0.997). CONCLUSION: the DGPS technique appears to be a valid and inconspicuous tool for "on line" monitoring of the speed of displacement of individuals located on any field on earth, for prolonged periods of time and unlimited distance, but only in specific environmental conditions ("open sky"). Furthermore, the accuracy of speed assessment using the differential GPS mode was improved by a factor of 10 as compared to non-differential GPS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Recombinant human growth hormone (rhGH) has been on the list of forbidden substances since availability of its recombinant form improved in the early 1990s. Although its effectiveness in enhancing physical performance is still unproved, the compound is likely used for its potential anabolic effect on the muscle growth, and also in combination with other products (androgens, erythropoietin, etc.). The degree of similarity between the endogenous and the recombinant forms, the pulsatile secretion and marked interindividual variability makes detection of doping difficult. Two approaches proposed to overcome this problem are: the indirect method, which measures a combination of several factors in the biological cascade affected by administration of GH; and the direct method, which measures the difference between the circulating and the recombinant (represented by the unique 22 kD molecule) forms of GH. This article gives an overview of what is presently known about hGH in relation to sport. The available methods of detection are also evaluated. METHODS: Review of the literature on GH in relation to exercise, and its adverse effects and methods of detection when used for doping. RESULTS AND CONCLUSION: The main effects of exercise on hGH production and the use and effects of rhGH in athletes are discussed. Difficulties encountered by laboratories to prove misuse of this substance by both indirect and direct analyses are emphasised. The direct method currently seems to have the best reliability, even though the time window of detection is too short. hGH doping is a major challenge in the fight against doping. The effect of exercise on hGH and its short half-life are still presenting difficulties during doping analysis. To date the most promising method appears to be the direct approach utilising immunoassays.