45 resultados para Entanglement measure
Resumo:
OBJECTIVE: A new tool to quantify visceral adipose tissue (VAT) over the android region of a total body dual-energy x-ray absorptiometry (DXA) scan has recently been reported. The measurement, CoreScan, is currently available on Lunar iDXA densitometers. The purpose of the study was to determine the precision of the CoreScan VAT measurement, which is critical for understanding the utility of this measure in longitudinal trials. DESIGN AND METHODS: VAT precision was characterized in both an anthropomorphic imaging phantom (measured on 10 Lunar iDXA systems) and a clinical population consisting of obese women (n = 32). RESULTS: The intrascanner precision for the VAT phantom across 9 quantities of VAT mass (0-1,800 g) ranged from 28.4 to 38.0 g. The interscanner precision ranged from 24.7 to 38.4 g. There was no statistical dependence on the quantity of VAT for either the inter- or intrascanner precision result (p = 0.670). Combining inter- and intrascanner precision yielded a total phantom precision estimate of 47.6 g for VAT mass, which corresponds to a 4.8% coefficient of variance (CV) for a 1 kg VAT mass. Our clinical population, who completed replicate total body scans with repositioning between scans, showed a precision of 56.8 g on an average VAT mass of 1110.4 g. This corresponds to a 5.1% CV. Hence, the in vivo precision result was similar to the phantom precision result. CONCLUSIONS: The study suggests that CoreScan has a relatively low precision error in both phantoms and obese women and therefore may be a useful addition to clinical trials where interventions are targeted towards changes in visceral adiposity.
The international development of the RGHQoL: a quality of life measure for recurrent genital herpes.
Resumo:
This paper describes the international development and psychometric testing of the Recurrent Genital Herpes Quality of Life Questionnaire (RGHQoL), a condition-specific quality of life (QoL) instrument. The theoretical foundation for the measure is the needs-based model of QoL and the content of the instrument was derived from in-depth qualitative interviews with relevant patients in the UK. Versions of the RGHQoL were required for the UK, USA, Italy, Germany, France and Denmark for use in international clinical trials. The results indicate that the final 20 item measure has good reliability, internal consistency and validity for all language versions. A small responsiveness study in Denmark suggested that the measure is sensitive to changes in QoL associated with the initiation of suppression treatment for recurrent genital herpes (RGH). It is concluded that the RGHQoL is a valuable instrument for inclusion in clinical trials. The psychometric properties of the instrument are such that it may also be used to monitor the progress of individual patients.
Resumo:
Delayed-choice experiments in quantum mechanics are often taken to undermine a realistic interpretation of the quantum state. More specifically, Healey has recently argued that the phenomenon of delayed-choice entanglement swapping is incompatible with the view that entanglement is a physical relation between quantum systems. This paper argues against these claims. It first reviews two paradigmatic delayed-choice experiments and analyzes their metaphysical implications. It then applies the results of this analysis to the case of entanglement swapping, showing that such experiments pose no threat to realism about entanglement.
Resumo:
CONTEXT: A passive knee-extension test has been shown to be a reliable method of assessing hamstring tightness, but this method does not take into account the potential effect of gravity on the tested leg. OBJECTIVE: To compare an original passive knee-extension test with 2 adapted methods including gravity's effect on the lower leg. DESIGN: Repeated measures. SETTING: Laboratory. PARTICIPANTS: 20 young track and field athletes (16.6 ± 1.6 y, 177.6 ± 9.2 cm, 75.9 ± 24.8 kg). INTERVENTION: Each subject was tested in a randomized order with 3 different methods: In the original one (M1), passive knee angle was measured with a standard force of 68.7 N (7 kg) applied proximal to the lateral malleolus. The second (M2) and third (M3) methods took into account the relative lower-leg weight (measured respectively by handheld dynamometer and anthropometrical table) to individualize the force applied to assess passive knee angle. MAIN OUTCOME MEASURES: Passive knee angles measured with video-analysis software. RESULTS: No difference in mean individualized applied force was found between M2 and M3, so the authors assessed passive knee angle only with M2. The mean knee angle was different between M1 and M2 (68.8 ± 12.4 vs 73.1 ± 10.6, P < .001). Knee angles in M1 and M2 were correlated (r = .93, P < .001). CONCLUSIONS: Differences in knee angle were found between the original passive knee-extension test and a method with gravity correction. M2 is an improved version of the original method (M1) since it minimizes the effect of gravity. Therefore, we recommend using it rather than M1.
Resumo:
Three-dimensional analysis of the entire sequence in ski jumping is recommended when studying the kinematics or evaluating performance. Camera-based systems which allow three-dimensional kinematics measurement are complex to set-up and require extensive post-processing, usually limiting ski jumping analyses to small numbers of jumps. In this study, a simple method using a wearable inertial sensors-based system is described to measure the orientation of the lower-body segments (sacrum, thighs, shanks) and skis during the entire jump sequence. This new method combines the fusion of inertial signals and biomechanical constraints of ski jumping. Its performance was evaluated in terms of validity and sensitivity to different performances based on 22 athletes monitored during daily training. The validity of the method was assessed by comparing the inclination of the ski and the slope at landing point and reported an error of -0.2±4.8°. The validity was also assessed by comparison of characteristic angles obtained with the proposed system and reference values in the literature; the differences were smaller than 6° for 75% of the angles and smaller than 15° for 90% of the angles. The sensitivity to different performances was evaluated by comparing the angles between two groups of athletes with different jump lengths and by assessing the association between angles and jump lengths. The differences of technique observed between athletes and the associations with jumps length agreed with the literature. In conclusion, these results suggest that this system is a promising tool for a generalization of three-dimensional kinematics analysis in ski jumping.
Resumo:
AIM: Inulin clearance (Cin) is the gold standard for assessing glomerular filtration rate (GFR). Other methods are based on the plasma creatinine concentration (Pcreat), creatinine clearance (Ccreat), the Haycock-Schwartz formula and the plasma concentration of cystatin C (PcysC), a 13 kDa basic protein produced at a constant rate by all nucleated cells. The present prospective study was thus designed to evaluate the reliability of PcysC as a marker of GFR in comparison with that of Pcreat, Ccreat and the Haycock-Schwartz formula, using Cin as the gold standard. METHODS: Ninety-nine children (51 m/48 f), with a median age of 8.3 y (1.0-17.9) were studied. Using a cut-off for Cin of 100 ml/min per 1.73 m2, 54 children (54.5%) had impaired GFR. Those with normal GFR were comparable for age, height, weight and body mass index. RESULTS: Logistic regression, ROC analysis and linear regression all showed that Ccreat was the best parameter to discriminate between impaired and normal GFR, followed by the Haycock-Schwartz formula, PcysC, and finally Pcreat, each one being significantly more predictive than the next. CONCLUSION: GFR is better assessed by the Haycock-Schwartz formula than by PcysC or Pcreat alone. It is therefore concluded that when urine collection is not possible, simply measuring the child's Pcreat and height is the best, easiest and cheapest way to assess GFR.
Resumo:
The purpose of this study was to evaluate a new method of measuring rolling resistance in treadmill cycling and to establish its sensitivity and reproducibility. One participant was asked to keep a bicycle in equilibrium on a treadmill without pedalling at a constant speed of 5.56 m x s(-1), which was held in place in the front by a dynamometer. For each condition, the method consisted of 11 measurements of the force required to hold the cycle at different treadmill slopes (0-10%, increment 1%). The coefficient of rolling resistance was calculated based on the forces applied to the bicycle in equilibrium. To test the sensitivity of the method, the bicycle was successively equipped with three tyre types (700 x 28, 700 x 23, 700 x 22) and inflation pressure was set at 150, 300, 600, 900, and 1100 kPa. To test the reproducibility of the method, a second experimenter repeated all measurements done with the 700 x 23 tyres. The method was sensitive enough to detect an effect of both tyre type and inflation pressure (P < 0.001: two-way ANOVA). The measurement of the coefficient of rolling resistance by two separate experimenters resulted in a small bias of 0.00029 (95% CI, -0.00011 to 0.00068). In conclusion, the new method is sensitive and reliable, as well as being simple and affordable.
Resumo:
Many interventions promoting physical activity (PA) are effective in preventing disease onset, and although studies have found a positive relationship between health-related quality of life (HRQL) and PA, most of these studies have focused on older adults and those with chronic conditions. Less is known regarding the association between PA level and HRQL among healthy adults. Our objective was to analyse the relationship between PA level and HRQL among a sample of 573 employees aged 20-68 taking part in a workplace intervention to promote PA. Measures included HRQL (using a single item) and PA (i.e. Godin Leisure-Time Questionnaire). The Modified Canadian Aerobic Fitness Test (MCAFT) was also completed by 10% of the employees. MET-minute scores (assessing energy expenditure over one week) were compared across HRQL categories using ANOVA. A multiple linear regression analysis was conducted to further examine the relationship between HRQL and PA, controlling for potential covariates. Participants in the higher health status categories were found to report higher levels of energy expenditure (one-way ANOVA, p < 0.001). In the multiple linear regression model, each unit increase in health status level translated in a mean increase of 356 MET-minutes in energy expenditure (p < 0.001). This single-item assessment of health status explained six percent of the variance in energy expenditure. The study concludes that higher energy expenditure through PA among an adult workplace population is positively associated with increased health status, and it also suggests that a single-item HRQL measure is suitable for community- and population-based studies, reducing response burden and research costs.
Resumo:
Cortical folding (gyrification) is determined during the first months of life, so that adverse events occurring during this period leave traces that will be identifiable at any age. As recently reviewed by Mangin and colleagues(2), several methods exist to quantify different characteristics of gyrification. For instance, sulcal morphometry can be used to measure shape descriptors such as the depth, length or indices of inter-hemispheric asymmetry(3). These geometrical properties have the advantage of being easy to interpret. However, sulcal morphometry tightly relies on the accurate identification of a given set of sulci and hence provides a fragmented description of gyrification. A more fine-grained quantification of gyrification can be achieved with curvature-based measurements, where smoothed absolute mean curvature is typically computed at thousands of points over the cortical surface(4). The curvature is however not straightforward to comprehend, as it remains unclear if there is any direct relationship between the curvedness and a biologically meaningful correlate such as cortical volume or surface. To address the diverse issues raised by the measurement of cortical folding, we previously developed an algorithm to quantify local gyrification with an exquisite spatial resolution and of simple interpretation. Our method is inspired of the Gyrification Index(5), a method originally used in comparative neuroanatomy to evaluate the cortical folding differences across species. In our implementation, which we name local Gyrification Index (lGI(1)), we measure the amount of cortex buried within the sulcal folds as compared with the amount of visible cortex in circular regions of interest. Given that the cortex grows primarily through radial expansion(6), our method was specifically designed to identify early defects of cortical development. In this article, we detail the computation of local Gyrification Index, which is now freely distributed as a part of the FreeSurfer Software (http://surfer.nmr.mgh.harvard.edu/, Martinos Center for Biomedical Imaging, Massachusetts General Hospital). FreeSurfer provides a set of automated reconstruction tools of the brain's cortical surface from structural MRI data. The cortical surface extracted in the native space of the images with sub-millimeter accuracy is then further used for the creation of an outer surface, which will serve as a basis for the lGI calculation. A circular region of interest is then delineated on the outer surface, and its corresponding region of interest on the cortical surface is identified using a matching algorithm as described in our validation study(1). This process is repeatedly iterated with largely overlapping regions of interest, resulting in cortical maps of gyrification for subsequent statistical comparisons (Fig. 1). Of note, another measurement of local gyrification with a similar inspiration was proposed by Toro and colleagues(7), where the folding index at each point is computed as the ratio of the cortical area contained in a sphere divided by the area of a disc with the same radius. The two implementations differ in that the one by Toro et al. is based on Euclidian distances and thus considers discontinuous patches of cortical area, whereas ours uses a strict geodesic algorithm and include only the continuous patch of cortical area opening at the brain surface in a circular region of interest.
Resumo:
The functional avidity is determined by exposing T-cell populations in vitro to different amounts of cognate antigen. T-cells with high functional avidity respond to low antigen doses. This in vitro measure is thought to correlate well with the in vivo effector capacity of T-cells. We here present the multifaceted factors determining and influencing the functional avidity of T-cells. We outline how changes in the functional avidity can occur over the course of an infection. This process, known as avidity maturation, can occur despite the fact that T-cells express a fixed TCR. Furthermore, examples are provided illustrating the importance of generating T-cell populations that exhibit a high functional avidity when responding to an infection or tumors. Furthermore, we discuss whether criteria based on which we evaluate an effective T-cell response to acute infections can also be applied to chronic infections such as HIV. Finally, we also focus on observations that high-avidity T-cells show higher signs of exhaustion and facilitate the emergence of virus escape variants. The review summarizes our current understanding of how this may occur as well as how T-cells of different functional avidity contribute to antiviral and anti-tumor immunity. Enhancing our knowledge in this field is relevant for tumor immunotherapy and vaccines design.
Resumo:
HYPOTHESIS: During total shoulder arthroplasty (TSA), humeral head subluxation may be difficult to manage. Furthermore, there is a risk for postoperative recurrence of subluxation, affecting the outcome of TSA. An accurate evaluation of the subluxation is necessary to evaluate this risk. Currently, subluxation is measured in 2 dimensions (2D), usually relative to the glenoid face. The goal of this study was to extend this measure to 3 dimensions (3D) to compare glenohumeral and scapulohumeral subluxation and to evaluate the association of subluxation with the glenoid version. MATERIALS AND METHODS: The study analyzed 112 computed tomography scans of osteoarthritic shoulders. We extended the usual 2D definition of glenohumeral subluxation, scapulohumeral subluxation, and glenoid version by measuring their orientation in 3D relative to the scapular plane and the scapular axis. We evaluated statistical associations between subluxation and version in 2D and 3D. RESULTS: Orientation of subluxation and version covered all sectors of the glenoid surface. Scapulohumeral subluxation and glenoid version were highly correlated in amplitude (R(2) = 0.71; P < .01) and in orientation (R(2) = 0.86; P < .01). Approximately every degree of glenoid version induced 1% of scapulohumeral subluxation in the same orientation of the version. Conversely, glenohumeral subluxation was not correlated to glenoid version in 2D or in 3D. CONCLUSIONS: Orientation of the humeral subluxation is rarely within the arbitrary computed tomography plane and should therefore be measured in 3D to detect out-of-plane subluxation. Scapulohumeral subluxation and glenoid version measured in 3D could bring valuable information for decision making during TSA.
Resumo:
Depth-dose curves in LiF detectors of different effective thicknesses, together with their responses, were calculated for typical nuclear medicine radiation fields with 99mTc, 18F and 90Y sources. Responses were analysed in function of the radionuclide, detector effective thickness and irradiation geometry. On the other hand the results of the nuclear medicine measurement campaign of the ORAMED project were presented focussing on the dose distribution across the hand and on the appropriate position to wear the dosimeter.According to the results, thin LiF detectors provide better responses in all cases. Its use is essential for 18F, since thick dosimeters can underestimate Hp(0.07) up to a 50% because of the very inhomogeneous dose deposition on the active layer. The preliminary results of the measurement campaign showed that the index tip of the non-dominant hand is usually the most exposed position among the 22 monitored positions. It was also found that, in average, wrist dosimeters are likely to underestimate the maximum skin dose by a factor of the order of 20. This factor is reduced to around 6 for a ring dosimeter worn on the base of the index of the non-dominant hand. Thus, for typical nuclear medicine procedures, the base of the index of the non-dominant hand is recommended as the best monitoring option.