38 resultados para Electronic conductivity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding the influence of pore space characteristics on the hydraulic conductivity and spectral induced polarization (SIP) response is critical for establishing relationships between the electrical and hydrological properties of surficial unconsolidated sedimentary deposits, which host the bulk of the world's readily accessible groundwater resources. Here, we present the results of laboratory SIP measurements on industrial-grade, saturated quartz samples with granulometric characteristics ranging from fine sand to fine gravel, which can be regarded as proxies for widespread alluvial deposits. We altered the pore space characteristics by changing (i) the grain size spectra, (ii) the degree of compaction, and (iii) the level of sorting. We then examined how these changes affect the SIP response, the hydraulic conductivity, and the specific surface area of the considered samples. In general, the results indicate a clear connection between the SIP response and the granulometric as well as pore space characteristics. In particular, we observe a systematic correlation between the hydraulic conductivity and the relaxation time of the Cole-Cole model describing the observed SIP effect for the entire range of considered grain sizes. The results do, however, also indicate that the detailed nature of these relations depends strongly on variations in the pore space characteristics, such as, for example, the degree of compaction. The results of this study underline the complexity of the origin of the SIP signal as well as the difficulty to relate it to a single structural factor of a studied sample, and hence raise some fundamental questions with regard to the practical use of SIP measurements as site- and/or sample-independent predictors of the hydraulic conductivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Significant progress has been made with regard to the quantitative integration of geophysical and hydrological data at the local scale. However, extending the corresponding approaches to the regional scale represents a major, and as-of-yet largely unresolved, challenge. To address this problem, we have developed an upscaling procedure based on a Bayesian sequential simulation approach. This method is then applied to the stochastic integration of low-resolution, regional-scale electrical resistivity tomography (ERT) data in combination with high-resolution, local-scale downhole measurements of the hydraulic and electrical conductivities. Finally, the overall viability of this upscaling approach is tested and verified by performing and comparing flow and transport simulation through the original and the upscaled hydraulic conductivity fields. Our results indicate that the proposed procedure does indeed allow for obtaining remarkably faithful estimates of the regional-scale hydraulic conductivity structure and correspondingly reliable predictions of the transport characteristics over relatively long distances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extended pharmacological venous thromboembolism (VTE) prophylaxis beyond discharge is recommended for patients undergoing high-risk surgery. We prospectively investigated prophylaxis in 1,046 consecutive patients undergoing major orthopaedic (70%) or major cancer surgery (30%) in 14 Swiss hospitals. Appropriate in-hospital prophylaxis was used in 1,003 (96%) patients. At discharge, 638 (61%) patients received prescription for extended pharmacological prophylaxis: 564 (77%) after orthopaedic surgery, and 74 (23%) after cancer surgery (p < 0.001). Patients with knee replacement (94%), hip replacement (81%), major trauma (80%), and curative arthroscopy (73%) had the highest prescription rates for extended VTE prophylaxis; the lowest rates were found in patients undergoing major surgery for thoracic (7%), gastrointestinal (19%), and hepatobiliary (33%) cancer. The median duration of prescribed extended prophylaxis was longer in patients with orthopaedic surgery (32 days, interquartile range 14-40 days) than in patients with cancer surgery (23 days, interquartile range 11-30 days; p<0.001). Among the 278 patients with an extended prophylaxis order after hip replacement, knee replacement, or hip fracture surgery, 120 (43%) received a prescription for at least 35 days, and among the 74 patients with an extended prophylaxis order after major cancer surgery, 20 (27%) received a prescription for at least 28 days. In conclusion, approximately one quarter of the patients with major orthopaedic surgery and more than three quarters of the patients with major cancer surgery did not receive prescription for extended VTE prophylaxis. Future effort should focus on the improvement of extended VTE prophylaxis, particularly in patients undergoing major cancer surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A geophysical and geochemical study has been conducted in a fractured carbonate aquifer located at Combioula in the southwestern Swiss Alps with the objective to detect and characterize hydraulically active fractures along a 260-m-deep borehole. Hydrochemical analyses, borehole diameter, temperature and fluid electrical conductivity logging data were integrated in order to relate electrokinetic self-potential signals to groundwater flow inside the fracture network. The results show a generally good, albeit locally variable correlation of variations of the self-potential signals with variations in temperature, fluid electrical conductivity and borehole diameter. Together with the hydrochemical evidence, which was found to be critical for the interpretation of the self-potential data, these measurements not only made it possible to detect the hydraulically active fractures but also to characterize them as zones of fluid gain or fluid loss. The results complement the available information from the corresponding litholog and illustrate the potential of electrokinetic self-potential signals in conjunction with temperature, fluid electrical conductivity and hydrochemical analyses for the characterization of fractured aquifers, and thus may offer a perspective for an effective quantitative characterization of this increasingly important class of aquifers and geothermal reservoirs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Urine is still the matrix of choice to fight against doping, because it can be collected non-invasively during anti-doping tests. Most of the World Anti-Doping Agency's accredited laboratories have more than 20 years experience in analyzing this biological fluid and the majority of the compounds listed in the 2010 Prohibited List - International Standard are eliminated through the urinary apparatus. Storing and transporting urine samples for doping analyses does not include a specific protocol to prevent microbial and thermal degradation. The use of a rapid and reliable screening method could enable determine reference intervals for urine specimens in doping control samples and evaluate notably the prevalence of microbial contamination known to be responsible for the degradation of chemical substances in urine.Methods: The Sysmex(R) UF-500i is a recent urine flow cytometer analyzer capable of quantifying BACT and other urinary particles such as RBC, WBC, EC, DEBRIS, CAST, PATH. CAST, YLC, SRC as well as measuring urine conductivity. To determine urine anti-doping reference intervals, 501 samples received in our laboratory over a period of two months were submitted to an immediate examination. All samples were collected and then transported at room temperature. Analysis of variance was performed to test the effects of factors such as gender, test type [in-competition, out-of-competition] and delivery time.Results: The data obtained showed that most of the urine samples were highly contaminated with bacteria. The other urine particles were also very different according to the factors.Conclusions: The Sysmex(R) UF-500i was capable of providing a snapshot of urine particles present in the samples at the time of the delivery to the laboratory. These particles, BACT in particular, gave a good idea of the possible microbial degradation which had and/or could have occurred in the sample. This information could be used as the first quality control set up in WADA (World Anti-Doping Agency) accredited laboratories to determine if steroid profiles, endogenous and prohibited substances have possibly been altered. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of electronic control devices has expanded worldwide during the last few years, the most widely used model being the Taser. However, the scientific knowledge about electronic control devices remains limited. We reviewed the medical literature to examine the potential implications of electronic devices in terms of morbidity and mortality, and to identify and evaluate all the existing experimental human studies. A single exposure of an electronic control device on healthy individuals can be assumed to be generally safe, according to 23 prospective human experimental studies and numerous volunteer exposures. In case series, however, electronic control devices could have deleterious effects when used in the field, in particular if persons receive multiple exposures, are intoxicated, show signs of "excited delirium," or present with medical comorbidities. As the use of electronic control devices continues to increase, the controversy about its safety, notably in potentially high-risk individuals, is still a matter of debate. The complications of electronic control device exposure are numerous but often recognizable, usually resulting from barbed dart injuries or from falls. Persons exposed to electronic control devices should therefore be fully examined, and traumatic lesions must be ruled out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical Impedance Tomography (EIT) is an imaging method which enables a volume conductivity map of a subject to be produced from multiple impedance measurements. It has the potential to become a portable non-invasive imaging technique of particular use in imaging brain function. Accurate numerical forward models may be used to improve image reconstruction but, until now, have employed an assumption of isotropic tissue conductivity. This may be expected to introduce inaccuracy, as body tissues, especially those such as white matter and the skull in head imaging, are highly anisotropic. The purpose of this study was, for the first time, to develop a method for incorporating anisotropy in a forward numerical model for EIT of the head and assess the resulting improvement in image quality in the case of linear reconstruction of one example of the human head. A realistic Finite Element Model (FEM) of an adult human head with segments for the scalp, skull, CSF, and brain was produced from a structural MRI. Anisotropy of the brain was estimated from a diffusion tensor-MRI of the same subject and anisotropy of the skull was approximated from the structural information. A method for incorporation of anisotropy in the forward model and its use in image reconstruction was produced. The improvement in reconstructed image quality was assessed in computer simulation by producing forward data, and then linear reconstruction using a sensitivity matrix approach. The mean boundary data difference between anisotropic and isotropic forward models for a reference conductivity was 50%. Use of the correct anisotropic FEM in image reconstruction, as opposed to an isotropic one, corrected an error of 24 mm in imaging a 10% conductivity decrease located in the hippocampus, improved localisation for conductivity changes deep in the brain and due to epilepsy by 4-17 mm, and, overall, led to a substantial improvement on image quality. This suggests that incorporation of anisotropy in numerical models used for image reconstruction is likely to improve EIT image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyzed 42 models from 14 brands of refill liquids for e-cigarettes for the presence of micro-organisms, diethylene glycol, ethylene glycol, hydrocarbons, ethanol, aldehydes, tobacco-specific nitrosamines, and solvents. All the liquids under scrutiny complied with norms for the absence of yeast, mold, aerobic microbes, Staphylococcus aureus, and Pseudomonas aeruginosa. Diethylene glycol, ethylene glycol and ethanol were detected, but remained within limits authorized for food and pharmaceutical products. Terpenic compounds and aldehydes were found in the products, in particular formaldehyde and acrolein. No sample contained nitrosamines at levels above the limit of detection (1 μg/g). Residual solvents such as 1,3-butadiene, cyclohexane and acetone, to name a few, were found in some products. None of the products under scrutiny were totally exempt of potentially toxic compounds. However, for products other than nicotine, the oral acute toxicity of the e-liquids tested seems to be of minor concern. However, a minority of liquids, especially those with flavorings, showed particularly high ranges of chemicals, causing concerns about their potential toxicity in case of chronic oral exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postmortem imaging consists in the non-invasive examination of bodies using medical imaging techniques. However, gas volume quantification and the interpretation of the gas collection results from cadavers remain difficult. We used whole-body postmortem multi-detector computed tomography (MDCT) followed by a full autopsy or external examination to detect the gaseous volumes in bodies. Gases were sampled from cardiac cavities, and the sample compositions were analyzed by headspace gas chromatography-mass spectrometry/thermal conductivity detection (HS-GC-MS/TCD). Three categories were defined according to the presumed origin of the gas: alteration/putrefaction, high-magnitude vital gas embolism (e.g., from scuba diving accident) and gas embolism of lower magnitude (e.g., following a traumatic injury). Cadaveric alteration gas was diagnosed even if only one gas from among hydrogen, hydrogen sulfide or methane was detected. In alteration cases, the carbon dioxide/nitrogen ratio was often >0.2, except in the case of advanced alteration, when methane presence was the best indicator. In the gas embolism cases (vital or not), hydrogen, hydrogen sulfide and methane were absent. Moreover, with high-magnitude vital gas embolisms, carbon dioxide content was >20%, and the carbon dioxide/nitrogen ratio was >0.2. With gas embolisms of lower magnitude (gas presence consecutive to a traumatic injury), carbon dioxide content was <20% and the carbon dioxide/nitrogen ratio was often <0.2. We found that gas analysis provided useful assistance to the postmortem imaging diagnosis of causes of death. Based on the quantifications of gaseous cardiac samples, reliable indicators were determined to document causes of death. MDCT examination of the body must be performed as quickly as possible, as does gas sampling, to avoid generating any artifactual alteration gases. Because of cardiac gas composition analysis, it is possible to distinguish alteration gases and gas embolisms of different magnitudes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: In some countries, nicotine-containing electronic cigarettes (e-cigarettes) are considered a consumer product without specific regulations. In others (eg, Switzerland), the sale of e-cigarettes containing nicotine is forbidden, despite the eagerness of many smokers to obtain them. As scientific data about efficacy and long-term safety of these products are scarce, tobacco control experts are divided on how to regulate them. In order to gain consensus among experts to provide recommendations to health authorities, we performed a national consensus study. SETTING: We used a Delphi method with electronic questionnaires to bring together the opinion of Swiss experts on e-cigarettes. PARTICIPANTS: 40 Swiss experts from across the country. OUTCOME MEASURES: We measured the degree of consensus between experts on recommendations regarding regulation, sale, use of and general opinion about e-cigarettes containing nicotine. New recommendations and statements were added following the experts' answers and comments. RESULTS: There was consensus that e-cigarettes containing nicotine should be made available, but only under specific conditions. Sale should be restricted to adults, using quality standards, a maximum level of nicotine and with an accompanying list of authorised ingredients. Advertisement should be restricted and use in public places should be forbidden. CONCLUSIONS: These recommendations encompass three principles: (1) the reality principle, as the product is already on the market; (2) the prevention principle, as e-cigarettes provide an alternative to tobacco for actual smokers, and (3) the precautionary principle, to protect minors and non-smokers, since long-term effects are not yet known. Swiss authorities should design specific regulations to sell nicotine-containing e-cigarettes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: All methods presented to date to map both conductivity and permittivity rely on multiple acquisitions to compute quantitatively the magnitude of radiofrequency transmit fields, B1+. In this work, we propose a method to compute both conductivity and permittivity based solely on relative receive coil sensitivities ( B1-) that can be obtained in one single measurement without the need to neither explicitly perform transmit/receive phase separation nor make assumptions regarding those phases. THEORY AND METHODS: To demonstrate the validity and the noise sensitivity of our method we used electromagnetic finite differences simulations of a 16-channel transceiver array. To experimentally validate our methodology at 7 Tesla, multi compartment phantom data was acquired using a standard 32-channel receive coil system and two-dimensional (2D) and 3D gradient echo acquisition. The reconstructed electric properties were correlated to those measured using dielectric probes. RESULTS: The method was demonstrated both in simulations and in phantom data with correlations to both the modeled and bench measurements being close to identity. The noise properties were modeled and understood. CONCLUSION: The proposed methodology allows to quantitatively determine the electrical properties of a sample using any MR contrast, with the only constraint being the need to have 4 or more receive coils and high SNR. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'usage de cigarettes électroniques (vapotage) augmente chez les jeunes et les professionnels de la santé se sentent démunis. Ce court article donne quelques informations pratiques. L'usage (vapotage) de cigarettes électroniques (e-cigarettes) est un phénomène relativement récent qui est en train de prendre une ampleur inattendue, surtout chez les jeunes. Bien que les taux de prévalence soient extrêmement variables d'un pays à l'autre, ils sont en net augmentation: tant parmi ceux qui les ont seulement essayées que chez ceux qui les utilisent habituellement, les taux de prévalence ont doublé ou presque triplé en à peine une année. En outre, une proportion notable d'utilisateurs d'e-cigarettes (de 8 à 33% selon les études)n'avaient jamais fumé de cigarettes conventionnelles. Ce phénomène pourrait faire des e-cigarettes la porte d'entrée au tabagisme parmi les jeunes. Adolescents and electronic cigarettes: The use of electronic cigarettes (vaping) is increasing among young people and health professionals feel ill-prepared. This short article provides some practical information The use of electronic cigarettes (vaping) is increasing among young people and health professionals feel ill-prepared. This short article provides some practical information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To review the available knowledge on epidemiology and diagnoses of acute infections in children aged 2 to 59 months in primary care setting and develop an electronic algorithm for the Integrated Management of Childhood Illness to reach optimal clinical outcome and rational use of medicines. METHODS: A structured literature review in Medline, Embase and the Cochrane Database of Systematic Review (CDRS) looked for available estimations of diseases prevalence in outpatients aged 2-59 months, and for available evidence on i) accuracy of clinical predictors, and ii) performance of point-of-care tests for targeted diseases. A new algorithm for the management of childhood illness (ALMANACH) was designed based on evidence retrieved and results of a study on etiologies of fever in Tanzanian children outpatients. FINDINGS: The major changes in ALMANACH compared to IMCI (2008 version) are the following: i) assessment of 10 danger signs, ii) classification of non-severe children into febrile and non-febrile illness, the latter receiving no antibiotics, iii) classification of pneumonia based on a respiratory rate threshold of 50 assessed twice for febrile children 12-59 months; iv) malaria rapid diagnostic test performed for all febrile children. In the absence of identified source of fever at the end of the assessment, v) urine dipstick performed for febrile children <2 years to consider urinary tract infection, vi) classification of 'possible typhoid' for febrile children >2 years with abdominal tenderness; and lastly vii) classification of 'likely viral infection' in case of negative results. CONCLUSION: This smartphone-run algorithm based on new evidence and two point-of-care tests should improve the quality of care of <5 year children and lead to more rational use of antimicrobials.