362 resultados para Drug injection
Resumo:
As a part of the HIV behavioural surveillance system in Switzerland, repeated cross-sectional surveys were conducted in 1993, 1994, 1996, 2000 and 2006 among attenders of all low threshold facilities (LTFs) with needle exchange programmes and/or supervised drug consumption rooms for injection or inhalation in Switzerland. Data were collected in each LTF over five consecutive days, using a questionnaire that was partly completed by an interviewer and partly self administered. The questionnaire was structured around three topics: socio-demographic characteristics, drug consumption, health and risk/preventive behaviour. Analysis was restricted to attenders who had injected drugs during their lifetime (IDUs). Between 1993 and 2006, the median age of IDUs rose by 10 years. IDUs are severely marginalised and their social situation has improved little. The borrowing of used injection equipment (syringe or needle already used by other person) in the last six months decreased (16.5% in 1993, 8.9% in 2006) but stayed stable at around 10% over the past three surveys. Other risk behaviour, such as sharing spoons, cotton or water, was reported more frequently, although also showed a decreasing trend. The reported prevalence of HIV remained fairly stable at around 10% between 1993 and 2006; reported levels of hepatitis C virus (HCV) prevalence were high (56.4% in 2006). In conclusion, the overall decrease in the practice of injection has reduced the potential for transmission of infections. However as HCV prevalence is high this is of particular concern, as the current behaviour of IDUs indicates a potential for further spreading of the infection. Another noteworthy trend is the significant decrease in condom use in the case of paid sex.
Resumo:
PURPOSE: To evaluate the incidence of presumed endophthalmitis (EO) after intravitreal injection (IVI) of anti-vascular endothelial growth factor agents performed in the operating room. METHODS: Retrospective study at 2 Swiss eye hospitals between 2004 and 2012. Hospital records were used to identify patients treated with an IVI of an anti-vascular endothelial growth factor agent between 2004 and 2012 and those treated for EO, defined as any intraocular inflammation treated with intravitreal antibiotics. All IVIs were performed using standard sterile technique in a Swiss Class 1 operating room. No patient received preinjection topical antibiotics. Postinjection topical antibiotics were used only in one hospital. RESULTS: A total of 40,011 IVIs were performed at the 2 centers during the study period. Of the IVIs, ranibizumab was injected in 36,398 (91%), bevacizumab in 3,518 (9%), aflibercept in 89 (0.2%), and pegaptanib in 6 (<0.1%). Three cases of post-IVI presumed EO occurred, yielding a combined incidence of 0.0075% per injection (95% confidence interval: 0.0026-0.0220%) or 1 case per 13,337 IVIs. Two of the three cases of EO occurred in patients using post-IVI antibiotics. All three cases followed ranibizumab injection and were culture negative by anterior chamber tap or vitreous biopsy. CONCLUSION: The risk of EO after IVI performed under the sterile conditions of the operating room was very low.
Resumo:
Successful detection of inflammatory lesions by planar scintigraphy and SPECT after injection of iodine-123 labelled monoclonal antibodies directed against human granulocytes (123I-Mabgc) is demonstrated. This new tracer has been compared with indium-111 labelled white blood cells (111In-WBC) in selected patients with proven infectious lesions. Scans were equally positive in all cases, but the methodical advantages of the new marker were obvious, namely, there is no need for cell separation and the images of inflammatory lesions were better defined. In addition, SPECT could be performed with 123I-Mabgc and allowed a better anatomic localization and a three-dimensional description of the lesions. No adverse reactions have been seen. It is concluded, therefore, that 123I-Mabgc is a promising agent for the detection of acute focal inflammatory lesions which may, with advantages, replace 111In-WBC.
Resumo:
BACKGROUND: Serial casting is often prescribed after botulinum toxin injections to improve joint ranges of motion and to potentiate the decrease in hypertonia. The aim of this study was to compare delayed versus immediate serial casting as an adjunct to botulinum toxin therapy for partially reducible spastic equinus. METHODS: Twelve children who presented spastic equinus associated with mild gastrosoleus contracture took part. Five of them had a diagnosis of spastic diplegia, whereas 7 had a diagnosis of congenital hemiplegia. Children were randomized to immediate serial casting (same day) or delayed serial casting (4 weeks later) after botulinum toxin injection to their gastrosolei. Casts were replaced weekly for 3 weeks. RESULTS: Three children complained of pain that required recasting in the immediate casting group versus none in the delayed casting group (P = 0.08). At 3 months, there was a 27-degree improvement in the fast dorsiflexion angle (Tardieu R1) in the delayed casting group versus 17 degrees in the immediate casting group (P = 0.029). At 6 months, a 19-degree improvement persisted in the delayed group compared with 11 degrees in the immediate group (P = 0.010). CONCLUSIONS: There is a clear benefit in delaying serial casting after the injection of botulinum toxin in the recurrence of spasticity at the gastrosoleus that may also offer an advantage regarding the incidence of painful episodes associated with casting. Most importantly, reducing the recurrence of spasticity by delayed serial casting may offer the possibility of decreasing the frequency of botulinum toxin reinjections.
Resumo:
PURPOSE: To study the kinetics of polylactide (PLA) nanoparticle (NP) localization within the intraocular tissues and to evaluate their potential to release encapsulated material. METHODS: A single intravitreous injection (5 micro L) of an NP suspension (2.2 mg/mL) encapsulating either Rh-6G (Rh) or Nile red (Nr) was performed. Animals were killed at various times, and the NPs localization within the intraocular tissues was studied by environmental scanning electron microscopy (ESEM), confocal microscopy, light microscopy histology, fluorescence microscopy, and immunohistochemistry. Eyes injected with blank NPs, free Rh, or PBS solution were used as the control. RESULTS: ESEM showed the flow of the NPs from the site of injection into the vitreous cavity and their rapid settling on the internal limiting membrane. Histology demonstrated the anatomic integrity of the injected eyes and showed no toxic effects. A mild inflammatory cell infiltrate was observed in the ciliary body 6 hours after the injection and in the posterior vitreous and retina at 18 to 24 hours. The intensity of inflammation decreased markedly by 48 hours. Confocal and fluorescence microscopy and immunohistochemistry showed that a transretinal movement of the NPs was gradually taking place with a later localization in the RPE cells. Rh encapsulated within the injected NPs diffused and stained the retina and RPE cells. PLA NPs were still present within the RPE cells 4 months after a single intravitreous injection. CONCLUSIONS: Intravitreous injection of PLA NPs appears to result in transretinal movement, with a preferential localization in the RPE cells. Encapsulated Rh diffuses from the NPs and stains the neuroretina and the RPE cells. The findings support the idea that specific targeting of these tissues is feasible. Furthermore, the presence of the NPs within the RPE cells 4 months after a single injection shows that a steady and continuous delivery of drugs can be achieved.
Resumo:
Abstract Purpose: We aimed to investigate the safety, tolerability, and systemic diffusion of a single escalating dose of XG-102 (a 31-D-amino-acid peptide inhibiting JNK pathway activation), administered subconjunctivally in the treatment of post-surgery or post-trauma intraocular inflammation. Methods: This is a dose-escalating, tolerance Phase Ib study. Twenty patients with post-surgery or post-traumatic intraocular inflammation were assigned to 1 of the 4 dose escalating (45, 90, 450, or 900 μg XG-102) groups of 5 patients each. Patients were evaluated at 24, 48 h, 8, and 28 days following the administration of XG-102, including laboratory tests, standard eye examinations, vital signs, and occurrence of adverse events. A single plasma quantification of XG-102 was performed 30 min after administration, according to previous pharmacokinetics studies performed on volunteers. Results: A total of 17 non-serious adverse events, considered unrelated to the study treatment, were reported for 10 patients. The adverse event incidence was not related to the drug dose. All patients experienced a decrease in intraocular inflammation as of 24 h post-administration and this decrease was sustained up to 28 days thereafter. No patient required local injection or systemic administration of corticoids following the administration of XG-102. XG-102 was undetectable in the first 3 dose groups. In the fourth-dose group (900 μg) the XG-102 plasma levels were above the limit of detection for 3 patients and above the limit of quantification for 1 patient. Conclusions: In this first clinical trial using XG-102, administered as a single subconjunctival injection as adjunct therapy, in patients with recent post-surgery or post-trauma intraocular inflammation is safe and well tolerated. Further studies are required to evaluate its efficacy.
Resumo:
PURPOSE: The combination of embolic beads with a multitargeted tyrosine kinase inhibitor that inhibits tumor vessel growth is suggested as an alternative and improvement to the current standard doxorubicin-eluting beads for use in transarterial chemoembolization. This study demonstrates the in vitro loading and release kinetics of sunitinib using commercially available embolization microspheres and evaluates the in vitro biologic efficacy on cell cultures and the resulting in vivo pharmacokinetics profiles in an animal model. MATERIALS AND METHODS: DC Bead microspheres, 70-150 µm and 100-300 µm (Biocompatibles Ltd., Farnham, United Kingdom), were loaded by immersion in sunitinib solution. Drug release was measured in saline in a USP-approved flow-through apparatus and quantified by spectrophotometry. Activity after release was confirmed in cell culture. For pharmacokinetics and in vivo toxicity evaluation, New Zealand white rabbits received sunitinib either by intraarterial injection of 100-300 µm sized beads or per os. Plasma and liver tissue drug concentrations were assessed by liquid chromatography-tandem mass spectroscopy. RESULTS: Sunitinib loading on beads was close to complete and homogeneous. A total release of 80% in saline was measured, with similar fast-release profiles for both sphere sizes. After embolization, drug plasma levels remained below the therapeutic threshold (< 50 ng/mL), but high concentrations at 6 hours (14.9 µg/g) and 24 hours (3.4 µg/g) were found in the liver tissue. CONCLUSIONS: DC Bead microspheres of two sizes were efficiently loaded with sunitinib and displayed a fast and almost complete release in saline. High liver drug concentrations and low systemic levels indicated the potential of sunitinib-eluting beads for use in embolization.
Resumo:
Drug-eluting microspheres are used for embolization of hypervascular tumors and allow for local controlled drug release. Although the drug release from the microspheres relies on fast ion-exchange, so far only slow-releasing in vitro dissolution methods have been correlated to in vivo data. Three in vitro release methods are assessed in this study for their potential to predict slow in vivo release of sunitinib from chemoembolization spheres to the plasma, and fast local in vivo release obtained in an earlier study in rabbits. Release in an orbital shaker was slow (t50%=4.5h, 84% release) compared to fast release in USP 4 flow-through implant cells (t50%=1h, 100% release). Sunitinib release in saline from microspheres enclosed in dialysis inserts was prolonged and incomplete (t50%=9 days, 68% release) due to low drug diffusion through the dialysis membrane. The slow-release profile fitted best to low sunitinib plasma AUC following injection of sunitinib-eluting spheres. Although limited by lack of standardization, release in the orbital shaker fitted best to local in vivo sunitinib concentrations. Drug release in USP flow-through implant cells was too fast to correlate with local concentrations, although this method is preferred to discriminate between different sphere types.
Resumo:
This article describes the application of a recently developed general unknown screening (GUS) strategy based on LC coupled to a hybrid linear IT-triple quadrupole mass spectrometer (LC-MS/MS-LIT) for the simultaneous detection and identification of drug metabolites following in vitro incubation with human liver microsomes. The histamine H1 receptor antagonist loratadine was chosen as a model compound to demonstrate the interest of such approach, because of its previously described complex and extensive metabolism. Detection and mass spectral characterization were based on data-dependent acquisition, switching between a survey scan acquired in the ion-trapping Q3 scan mode with dynamic subtraction of background noise, and a dependent scan in the ion-trapping product ion scan mode of automatically selected parent ions. In addition, the MS(3) mode was used in a second step to confirm the structure of a few fragment ions. The sensitivity of the ion-trapping modes combined with the selectivity of the triple quadrupole modes allowed, with only one injection, the detection and identification of 17 phase I metabolites of loratadine. The GUS procedure used in this study may be applicable as a generic technique for the characterization of drug metabolites after in vitro incubation, as well as probably in vivo experiments.
Resumo:
The major problems associated with the use of corticosteroids for the treatment of ocular diseases are their poor intraocular penetration to the posterior segment when administered locally and their secondary side effects when given systemically. To circumvent these problems more efficient methods and techniques of local delivery are being developed. The purposes of this study were: (1) to investigate the pharmacokinetics of intraocular penetration of hemisuccinate methyl prednisolone (HMP) after its delivery using the transscleral Coulomb controlled iontophoresis (CCI) system applied to the eye or after intravenous (i.v.) injection in the rabbit, (2) to test the safety of the CCI system for the treated eyes and (3) to compare the pharmacokinetic profiles of HMP intraocular distribution after CCI delivery to i.v. injection. For each parameter evaluated, six rabbit eyes were used. For the CCI system, two concentrations of HMP (62.5 and 150mg ml(-1)), various intensities of current and duration of treatment were analyzed. In rabbits serving as controls the HMP was infused in the CCI device but without applied electric current. For the i.v. delivery, HMP at 10mg kg(-1)as a 62.5mg ml(-1)solution was used. The rabbits were observed clinically for evidence of ocular toxicity. At various time points after the administration of drug, rabbits were killed and intraocular fluids and tissues were sampled for methylprednisolone (MP) concentrations by high pressure liquid chromatography (HPLC). Histology examinations were performed on six eyes of each group. Among groups that received CCI, the concentrations of MP increased in all ocular tissues and fluids in relation to the intensities of current used (0.4, 1.0 and 2.0mA/0.5cm(2)) and its duration (4 and 10min). Sustained and highest levels of MP were achieved in the choroid and the retina of rabbit eyes treated with the highest current and 10min duration of CCI. No clinical toxicity or histological lesions were observed following CCI. Negligible amounts of MP were found in ocular tissues in the CCI control group without application of current. Compared to i.v. administration, CCI achieved higher and more sustained tissue concentrations with negligible systemic absorption. These data demonstrate that high levels of MP can be safely achieved in intraocular tissues and fluids of the rabbit eye, using CCI. With this system, intraocular tissues levels of MP are higher than those achieved after i.v. injection. Furthermore, if needed, the drug levels achieved with CCI can be modulated as a function of current intensity and duration of treatment. CCI could therefore be used as an alternative method for the delivery of high levels of MP to the intraocular tissues of both the anterior and posterior segments.
Resumo:
We present a programmable microcontroller-driven injection system for the exchange of imaging medium during atomic force microscopy. Using this low-noise system, high-resolution imaging can be performed during this process of injection without disturbance. This latter circumstance was exemplified by the online imaging of conformational changes in DNA molecules during the injection of anticancer drug into the fluid chamber.
Resumo:
OBJECTIVE: Targeting neuroprotectants specifically to the cells that need them is a major goal in biomedical research. Many peptidic protectants contain an active sequence linked to a carrier such as the transactivator of transcription (TAT) transduction sequence, and here we test the hypothesis that TAT-linked peptides are selectively endocytosed into neurons stressed by excitotoxicity and focal cerebral ischemia. METHODS: In vivo experiments involved intracerebroventricular injection of TAT peptides or conventional tracers (peroxidase, fluorescein isothiocyanate-dextran) in young rats exposed to occlusion of the middle cerebral artery at postnatal day 12. Cellular mechanisms of uptake were analyzed in dissociated cortical neuronal cultures. RESULTS: In both models, all tracers were taken up selectively into stressed neurons by endocytosis. In the in vivo model, this was neuron specific and limited to the ischemic area, where the neurons displayed enhanced immunolabeling for early endosomal antigen-1 and clathrin. The highly efficient uptake of TAT peptides occurred by the same selective mechanism as for conventional tracers. All tracers were targeted to the nucleus and cytoplasm of neurons that appeared viable, although ultimately destined to die. In dissociated cortical neuronal cultures, an excitotoxic dose of N-methyl-D-aspartate induced a similar endocytosis. It was 100 times more efficient with TAT peptides than with dextran, because the former bound to heparan sulfate proteoglycans at the cell surface, but it depended on dynamin and clathrin in both cases. INTERPRETATION: Excitotoxicity-induced endocytosis is the main entry route for protective TAT peptides and targets selectively the neurons that need to be protected.
Resumo:
Switzerland has adopted a prevention strategy including the promotion of non-sharing injection material and use of condoms. The access to sterile equipment has been made easier, but regional differences still exist. Studies conducted between 1989 and 1992 among drug users in different Swiss regions are reviewed in order to examine if progress in prevention occurred. Syringe sharing diminished everywhere, but rather high sharing rates persist where sterile material is less accessible. Condom use increased, but the situation is still unsatisfactory considering the high HIV prevalence among i.v. drug users. Where several surveys have been conducted consecutively, a stabilization of HIV prevalence was observed. This suggests a slowing down of the progression of the epidemic among drug users. These results, obtained in few years, are encouraging in the light of the pessimism which prevailed at the beginning of the epidemic about the ability of drug users to adopt preventive behaviour.
Resumo:
BACKGROUND: Complications associated with intrathecal pumps may be linked to the surgical procedure, the implanted device, or the medication itself.¦CASE REPORTS: Three patients treated chronically with intrathecal clonidine presented with clonidine overdose due to inadvertent extravasation during the refilling procedure. All patients experienced loss of consciousness and severe systemic hypertension that required aggressive parenteral treatment.¦DISCUSSION: Clonidine is an alpha-2 agonist with a nearly 100% bioavailability after oral or rectal administration. With high plasma concentration secondary to massive systemic overdose, the specificity for the alpha-2 receptor is lost and an alpha-1 agonist activity predominates and causes marked hypertension. Management of clonidine overdose consists of supportive therapy guided by signs and symptoms.¦CONCLUSION: Inadvertent injection into the subcutaneous pocket rather than the reservoir is rare but very dangerous as the drug cannot be retrieved and massive doses are involved. Signs and symptoms of systemic overdose with drugs commonly used in implanted drugs delivery system should be well known to ensure early diagnosis and treatment.