26 resultados para Continuous monitoring with Polarographic Oxygen Sensor


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To compare the heart-rate monitoring with the doubly labelled water (2H2(18)O) method to estimate total daily energy expenditure in obese and non-obese children. DESIGN: Cross sectional study of obese and normal weight children. SUBJECTS: 13 prepubertal children: six obese (4M, 2F, 9.1 +/- 1.5 years, 47.3 +/- 9.7 kg) and seven non-obese (3M, 4F, 9.3 +/- 0.6 years, 31.8 +/- 3.2 kg). MEASUREMENTS: Total daily energy expenditure was assessed by means of the doubly labelled water method (TEEDLW) and of heart-rate monitoring (TEEHR). RESULTS: TEEHR was significantly (P < 0.05) higher than TEEDLW in obese children (9.47 +/- 0.84 MJ/d vs 8.99 +/- 0.63 MJ/d) whereas it was not different in non-obese children (8.43 +/- 2.02 MJ/d vs 8.42 +/- 2.30 MJ/d, P = NS). The difference of TEE assessed by HR monitoring in the obese group averaged 6.2 +/- 4.7%. At the individual level, the degree of agreement (difference between TEEHR and TEEDLW +/- 2s.d.) was low both in obese (-0.36, 1.32 MJ/d) and in non-obese children (-1.30, 1.34 MJ/d). At the group level, the agreement between the two methods was good in nonobese children (95% c.i. for the bias:-0.59, 0.63 MJ/d) but not in obese children (0.04, 0.92 MJ/d). Duration of sleep and energy expenditure during resting and physical activity were not significantly different in the two groups. Patterns of heart-rate (or derived energy expenditure) during the day-time were similar in obese and non-obese children. CONCLUSION: The HR monitoring technique provides an estimation of TEE close to that assessed by the DLW method in non-obese prepubertal children. In comparison with DLW, the HR monitoring method yields a greater TEE value in obese children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a viscometric affinity biosensor that can potentially allow continuous multi-analyte monitoring in biological fluids like blood or plasma. The sensing principle is based on the detection of viscosity changes of a polymeric solution which has a selective affinity for the analyte of interest. The chemico-mechanical sensor incorporates an actuating piezoelectric diaphragm, a sensing piezoelectric diaphragm and a flow-resisting microchannel for viscosity detection. A free-standing Anodic Alumina Oxide (AAO) porous nano-membrane is used as selective interface. A glucose-sensitive sensor was fabricated and extensively assessed in buffer solution. The sensor reversibility, stability and sensitivity were excellent during at least 65 hours. Results showed also a good degree of stability for a long term measurement (25 days). The sensor behaviour was furthermore tested in fetal bovine serum (FBS). The obtained results for glucose sensing are very promising, indicating that the developed sensor is a candidate for continuous monitoring in biological fluids. Sensitive solutions for ionized calcium and pH are currently under development and should allow multi-analyte sensing in the near future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Careful patient monitoring using a variety of techniques including clinical and laboratory evaluation, bedside physiological monitoring with continuous or non-continuous techniques and imaging is fundamental to the care of patients who require neurocritical care. How best to perform and use bedside monitoring is still being elucidated. To create a basic platform for care and a foundation for further research the Neurocritical Care Society in collaboration with the European Society of Intensive Care Medicine, the Society for Critical Care Medicine and the Latin America Brain Injury Consortium organized an international, multidisciplinary consensus conference to develop recommendations about physiologic bedside monitoring. This supplement contains a Consensus Summary Statement with recommendations and individual topic reviews as a background to the recommendations. In this article, we highlight the recommendations and provide additional conclusions as an aid to the reader and to facilitate bedside care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Inadequate intraoperative cerebral perfusion has been suggested as a possible cause of postoperative cognitive dysfunction (POCD). Methods: We investigated 35 patients aged 65 or older undergoing elective major non-cardiac surgery under standardized general anaesthesia (thiopental, sevoflurane, fentanyl, atracurium). Intraoperative cerebral perfusion was monitored with transcranial Doppler, and near-infrared spectroscopy (NIRS). Arterial blood pressure was monitored continuously with a Finapres device. Mx, an index allowing continuous monitoring of cerebrovascular autoregulation based on the changes in mean arterial blood pressure (MAP) and cerebral blood flow velocity was calculated. Mx >0.5 was defined as disturbed cerebrovascular autoregulation. Cognitive function was measured preoperatively and 7 days postoperatively using the CERAD-NAB Plus test battery. A postoperative decline >1 z-score in at least two of the tested domains was defined as POCD. Data are shown as mean } SD. Results: Mean age was 75 } 7 yrs. Sixteen patients (46%) developed POCD. These patients were older (77 } 8 vs 73 } 7 yrs), had lower MAP (77 } 12 vs 81 } 11 mm Hg), lower cerebral tissue oxygenation indices measured by NIRS (66.8 } 6.0 vs 68.6 } 4.3%) and less efficient cerebrovascular autoregulation (Mx 0.54 } 0.17 and 0.44 } 0.22) than patients without POCD. Disturbed intraoperative cerebrovascular autoregulation was found more often (56 vs 37%) in patients with POCD. However, none of these differences reached statistical significance. Conclusions: Our data show a trend towards subtle changes in intraoperative cerebral perfusion in elderly patients who develop POCD. However, a cause effect relationship must not be assumed and a greater number of patients needs to be investigated patients. However, more patients need to be investigated to confirm and characterize these differences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Early repolarization is a common electrocardiographic finding that is generally considered to be benign. Its potential to cause cardiac arrhythmias has been hypothesized from experimental studies, but it is not known whether there is a clinical association with sudden cardiac arrest. METHODS: We reviewed data from 206 case subjects at 22 centers who were resuscitated after cardiac arrest due to idiopathic ventricular fibrillation and assessed the prevalence of electrocardiographic early repolarization. The latter was defined as an elevation of the QRS-ST junction of at least 0.1 mV from baseline in the inferior or lateral lead, manifested as QRS slurring or notching. The control group comprised 412 subjects without heart disease who were matched for age, sex, race, and level of physical activity. Follow-up data that included the results of monitoring with an implantable defibrillator were obtained for all case subjects. RESULTS: Early repolarization was more frequent in case subjects with idiopathic ventricular fibrillation than in control subjects (31% vs. 5%, P<0.001). Among case subjects, those with early repolarization were more likely to be male and to have a history of syncope or sudden cardiac arrest during sleep than those without early repolarization. In eight subjects, the origin of ectopy that initiated ventricular arrhythmias was mapped to sites concordant with the localization of repolarization abnormalities. During a mean (+/-SD) follow-up of 61+/-50 months, defibrillator monitoring showed a higher incidence of recurrent ventricular fibrillation in case subjects with a repolarization abnormality than in those without such an abnormality (hazard ratio, 2.1; 95% confidence interval, 1.2 to 3.5; P=0.008). CONCLUSIONS: Among patients with a history of idiopathic ventricular fibrillation, there is an increased prevalence of early repolarization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The number of physical activity measures and indexes used in the human literature is large and may result in some difficulty for the average investigator to choose the most appropriate measure. Accordingly, this review is intended to provide information on the utility and limitations of the various measures. Its primary focus is the objective assessment of free-living physical activity in humans based on physiological and biomechanical methods. The physical activity measures have been classified into three categories: Measures based on energy expenditure or oxygen uptake, such as activity energy expenditure, activity-related time equivalent, physical activity level, physical activity ratio, metabolic equivalent, and a new index of potential interest, daytime physical activity level. Measures based on heart rate monitoring, such as net heart rate, physical activity ratio heart rate, physical activity level heart rate, activity-related time equivalent, and daytime physical activity level heart rate. Measures based on whole-body accelerometry (counts/U time). Quantification of the velocity and duration of displacement in outdoor conditions by satellites using the Differential Global Positioning System may constitute a surrogate for physical activity, because walking is the primary activity of man in free-living conditions. A general outline of the measures and indexes described above is presented in tabular form, along with their respective definition, usual applications, advantages, and shortcomings. A practical example is given with typical values in obese and non-obese subjects. The various factors to be considered in the selection of physical activity methods include experimental goals, sample size, budget, cultural and social/environmental factors, physical burden for the subject, and statistical factors, such as accuracy and precision. It is concluded that no single current technique is able to quantify all aspects of physical activity under free-living conditions, requiring the use of complementary methods. In the future, physical activity sensors, which are of low-cost, small-sized, and convenient for subjects, investigators, and clinicians, are needed to reliably monitor, during extended periods in free-living situations, small changes in movements and grade as well as duration and intensity of typical physical activities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mechanical ventilation (MV) is life-saving but potentially harmful for lungs of premature infants. So far, animal models dealt with the acute impact of MV on immature lungs, but less with its delayed effects. We used a newborn rodent model including non-surgical and therefore reversible intubation with moderate ventilation and hypothesized that there might be distinct gene expression patterns after a ventilation-free recovery period compared to acute effects directly after MV. Newborn rat pups were subjected to 8 hr of MV with 60% oxygen (O(2) ), 24 hr after injection of lipopolysaccharide (LPS), intended to create a low inflammatory background as often recognized in preterm infants. Animals were separated in controls (CTRL), LPS injection (LPS), or full intervention with LPS and MV with 60% O(2) (LPS + MV + O(2) ). Lungs were recovered either directly following (T:0 hr) or 48 hr after MV (T:48 hr). Histologically, signs of ventilator-induced lung injury (VILI) were observed in LPS + MV + O(2) lungs at T:0 hr, while changes appeared similar to those known from patients with chronic lung disease (CLD) with fewer albeit larger gas exchange units, at T:48 hr. At T:0 hr, LPS + MV + O(2) increased gene expression of pro-inflammatory MIP-2. In parallel anti-inflammatory IL-1Ra gene expression was increased in LPS and LPS + MV + O(2) groups. At T:48 hr, pro- and anti-inflammatory genes had returned to their basal expression. MMP-2 gene expression was decreased in LPS and LPS + MV + O(2) groups at T:0 hr, but no longer at T:48 hr. MMP-9 gene expression levels were unchanged directly after MV. However, at T:48 hr, gene and protein expression increased in LPS + MV + O(2) group. In conclusion, this study demonstrates the feasibility of delayed outcome measurements after a ventilation-free period in newborn rats and may help to further understand the time-course of molecular changes following MV. The differences obtained from the two time points could be interpreted as an initial transitory increase of inflammation and a delayed impact of the intervention on structure-related genes. Pediatr Pulmonol. 2012; 47:1204-1214. © 2012 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oxygen consumption of collagenase-liberated rat adipocytes was measured by two different techniques: a microspectrophotometric method using hemoglobin as indicator of respiration and a technique using the oxygen electrode. These two completely different techniques gave similar values for oxygen consumption. With the spectrophotometric method, the oxygen consumption of single fat cells was determined. A close positive correlation (r = greater than 0.90) between oxygen consumption and fat cell size was observed in each tissue examined. With the oxygen electrode technique, oxygen consumption of adipocyte suspensions from young (40 days, 180 g) and old (90 days, 480 g) rats was examined. Fat cells of the suspensions were separated into classes of different size by a flotation technique. A significant positive correlation between fat cell size and oxygen consumption was observed in both young (r = 0.88) and old (r = 0.95) rats. However, the slope was much steeper in young rats. At a cell weight of 0.1 microgram the oxygen consumption was 0.364 and 0.086 microL O2/10(6) cells/min-1 in young and old rats, respectively. In the literature, a number of separate metabolic pathways have been found to be related positively to fat cell size and negatively to age. We conclude that these scattered metabolic observations are in agreement with integrated data on energy expenditure as evaluated from oxygen consumption. Estimations of the energy expenditure of adipose tissue indicates that this tissue is responsible for about 1% and 0.5% of the total energy expenditure in young and old rats, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Take-off, the most important phase in ski jumping, has been primarily studied in terms of spatio-temporal parameters; little is known about its motor control aspects. This study aims to assess the inter-segment coordination of the shank-thigh and thigh-sacrum pairs using the continuous relative phase (CRP). In total 87 jumps were recorded from 33 athletes with an inertial sensor-based system. The CRP curves indicated that the thighs lead the shanks during the first part of take-off extension and that the shanks rotated faster at the take-off extension end. The thighs and sacrum first rotated synchronously, with the sacrum then taking lead, with finally the thighs rotating faster. Five characteristic features were extracted from the CRP and their relationship with jump length was tested. Three features of the shank-thigh pair and one of the thigh-sacrum pair reported a significant association with jump length. It was observed that athletes who achieved longer jumps had their thighs leading their shanks during a longer time, with these athletes also having a more symmetric movement between thighs and sacrum. This study shows that inter-segment coordination during the take-off extension is related to performance and further studies are necessary to contrast its importance with other ski jumping aspects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction ICM+ software encapsulates our 20 years' experience in brain monitoring. It collects data from a variety of bedside monitors and produces time trends of parameters defi ned using confi gurable mathematical formulae. To date it is being used in nearly 40 clinical research centres worldwide. We present its application for continuous monitoring of cerebral autoregulation using near-infrared spectroscopy (NIRS). Methods Data from multiple bedside monitors are processed by ICM+ in real time using a large selection of signal processing methods. These include various time and frequency domain analysis functions as well as fully customisable digital fi lters. The fi nal results are displayed in a variety of ways including simple time trends, as well as time window based histograms, cross histograms, correlations, and so forth. All this allows complex information from bedside monitors to be summarized in a concise fashion and presented to medical and nursing staff in a simple way that alerts them to the development of various pathological processes. Results One hundred and fi fty patients monitored continuously with NIRS, arterial blood pressure (ABP) and intracranial pressure (ICP), where available, were included in this study. There were 40 severely headinjured adult patients, 27 SAH patients (NCCU, Cambridge); 60 patients undergoing cardiopulmonary bypass (John Hopkins Hospital, Baltimore) and 23 patients with sepsis (University Hospital, Basel). In addition, MCA fl ow velocity (FV) was monitored intermittently using transcranial Doppler. FV-derived and ICP-derived pressure reactivity indices (PRx, Mx), as well as NIRS-derived reactivity indices (Cox, Tox, Thx) were calculated and showed signifi cant correlation with each other in all cohorts. Errorbar charts showing reactivity index PRx versus CPP (optimal CPP chart) as well as similar curves for NIRS indices versus CPP and ABP were also demonstrated. Conclusions ICM+ software is proving to be a very useful tool for enhancing the battery of available means for monitoring cerebral vasoreactivity and potentially facilitating autoregulation guided therapy. Complexity of data analysis is also hidden inside loadable profi les, thus allowing investigators to take full advantage of validated protocols including advanced processing formulas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An understanding of details of the interaction mechanisms of bacterial endotoxins (lipopolysaccharide, LPS) with the oxygen transport protein hemoglobin is still lacking, despite its high biological relevance. Here, a biophysical investigation into the endotoxin:hemoglobin interaction is presented which comprises the use of various rough mutant LPS as well as free lipid A; in addition to the complete hemoglobin molecule from fetal sheep extract, also the partial structure alpha-chain and the heme-free sample are studied. The investigations comprise the determination of the gel-to-liquid crystalline phase behaviour of the acyl chains of LPS, the ultrastructure (type of aggregate structure and morphology) of the endotoxins, and the incorporation of the hemoglobins into artificial immune cell membranes and into LPS. Our data suggest a model for the interaction between Hb and LPS in which hemoglobins do not react strongly with the hydrophilic or with the hydrophobic moiety of LPS, but with the complete endotoxin aggregate. Hb is able to incorporate into LPS with the longitudinal direction parallel to the lipid A double-layer. Although this does not lead to a strong disturbance of the LPS acyl chain packing, the change of the curvature leads to a slightly conical molecular shape with a change of the three-dimensional arrangement from unilamellar into cubic LPS aggregates. Our previous results show that cubic LPS structures exhibit strong endotoxic activity. The property of Hb on the physical state of LPS described here may explain the observation of an increase in LPS-mediating endotoxicity due to the action of Hb.