66 resultados para Component repository


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The origin of the slow component is not fully understood. The mechanical hypothesis is one of the potential factors, because an increase in external mechanical work with fatigue was previously reported for a constant velocity run. The purpose of this study was to determine whether a change in mechanical work could occur during the development of the VO2 slow component under the effect of fatigue. METHODS: Twelve regional-level competitive runners performed a square-wave transition, corresponding to 95% of the speed associated with peak VO2 obtained during an incremental test. The VO2 response was fit with a classical model including two exponential functions. A specific treadmill with three-dimensional force transducers was used to measure the ground reaction force. Kinetic work (W(kin)), potential work (W(pot)), external work (W(ext)), and an index of internal work (W(int)) per unit of distance were quantified continuously. RESULTS: During the slow component of VO2, a significant increase in W (P< 0.01), no change in W, and a significant decrease in W and W index (P< 0.05, P< 0.001, respectively) were observed. CONCLUSION: The present study showed that the slow component of VO2 did not result partly from a change in mechanical work under the effect of fatigue. Nevertheless, the decrease in stride frequency (P< 0.001) and contact time (P< 0.001) suggested an alternative mechanical explanation. The slow component during running may be due to the cost of generating force or to alterations in the storage and recoil of elastic energy, and not to the external mechanical work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to test the hypothesis of the involvement of type II fibres in the V.O (2) slow component phenomenon by using two prior fatiguing protocols on the knee extensor muscles. Nine subjects performed three constant-load cycling exercises at a work rate corresponding to 80 % of their V.O (2) max: (i) preceded by a 20-min fatiguing protocol using electromyostimulation (EMS), (ii) preceded by a 20-min fatiguing protocol using voluntary contractions (VOL), and (iii) without fatiguing protocol (NFP). Voluntary and evoked neuromuscular properties of the knee extensor muscles were tested before (PRE) and after (POST) the two fatiguing protocols. Results show a significant reduction in voluntary force after both fatiguing protocols (-19.9 % and -11.8 %, in EMS and VOL, respectively p<0.01). After EMS, this decrease was greater than after VOL (p<0.05) and was combined with a slackening of muscle contractile properties which was absent after VOL (p<0.05). Regarding the effects on oxygen uptake kinetics, the appearance of the slow component was delayed after EMS and its amplitude was lower than those obtained in VOL and NFP conditions (0.48+/-0.07 vs. 0.75+/-0.09 and 0.69+/-0.08 L . min (-1), respectively; p<0.05). It can thus be concluded that exercises dedicated to preferentially fatiguing type II fibres may alter V.O (2) kinetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The contribution of respiratory muscle work to the development of the O(2) consumption (Vo(2)) slow component is a point of controversy because it has been shown that the increased ventilation in hypoxia is not associated with a concomitant increase in Vo(2) slow component. The first purpose of this study was thus to test the hypothesis of a direct relationship between respiratory muscle work and Vo(2) slow component by manipulating inspiratory resistance. Because the conditions for a Vo(2) slow component specific to respiratory muscle can be reached during intense exercise, the second purpose was to determine whether respiratory muscles behave like limb muscles during heavy exercise. Ten trained subjects performed two 8-min constant-load heavy cycling exercises with and without a threshold valve in random order. Vo(2) was measured breath by breath by using a fast gas exchange analyzer, and the Vo(2) response was modeled after removal of the cardiodynamic phase by using two monoexponential functions. As anticipated, when total work was slightly increased with loaded inspiratory resistance, slight increases in base Vo(2), the primary phase amplitude, and peak Vo(2) were noted (14.2%, P < 0.01; 3.5%, P > 0.05; and 8.3%, P < 0.01, respectively). The bootstrap method revealed small coefficients of variation for the model parameter, including the slow-component amplitude and delay (15 and 19%, respectively), indicating an accurate determination for this critical parameter. The amplitude of the Vo(2) slow component displayed a 27% increase from 8.1 +/- 3.6 to 10.3 +/- 3.4 ml. min(-1). kg(-1) (P < 0.01) with the addition of inspiratory resistance. Taken together, this increase and the lack of any differences in minute volume and ventilatory parameters between the two experimental conditions suggest the occurrence of a Vo(2) slow component specific to the respiratory muscles in loaded condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Next-generation sequencing offers an unprecedented opportunity to jointly analyze cellular and viral transcriptional activity without prerequisite knowledge of the nature of the transcripts. SupT1 cells were infected with a vesicular stomatitis virus G envelope protein (VSV-G)-pseudotyped HIV vector. At 24 h postinfection, both cellular and viral transcriptomes were analyzed by serial analysis of gene expression followed by high-throughput sequencing (SAGE-Seq). Read mapping resulted in 33 to 44 million tags aligning with the human transcriptome and 0.23 to 0.25 million tags aligning with the genome of the HIV-1 vector. Thus, at peak infection, 1 transcript in 143 is of viral origin (0.7%), including a small component of antisense viral transcription. Of the detected cellular transcripts, 826 (2.3%) were differentially expressed between mock- and HIV-infected samples. The approach also assessed whether HIV-1 infection modulates the expression of repetitive elements or endogenous retroviruses. We observed very active transcription of these elements, with 1 transcript in 237 being of such origin, corresponding on average to 123,123 reads in mock-infected samples (0.40%) and 129,149 reads in HIV-1-infected samples (0.45%) mapping to the genomic Repbase repository. This analysis highlights key details in the generation and interpretation of high-throughput data in the setting of HIV-1 cellular infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of small, hydrophobic peptides that are associated with ion pumps or channels is still poorly understood. By using the Xenopus oocyte as an expression system, we have characterized the structural and functional properties of the gamma peptide which co-purifies with Na,K-ATPase. Immuno-radiolabeling of epitope-tagged gamma subunits in intact oocytes and protease protection assays show that the gamma peptide is a type I membrane protein lacking a signal sequence and exposing the N-terminus to the extracytoplasmic side. Co-expression of the rat or Xenopus gamma subunit with various proteins in the oocyte reveals that it specifically associates only with isozymes of Na,K-ATPase. The gamma peptide does not influence the formation and cell surface expression of functional Na,K-ATPase alpha-beta complexes. On the other hand, the gamma peptide itself needs association with Na,K-ATPase in order to be stably expressed in the oocyte and to be transported efficiently to the plasma membrane. Gamma subunits do not associate with individual alpha or beta subunits but only interact with assembled, transport-competent alpha-beta complexes. Finally, electrophysiological measurements indicate that the gamma peptide modulates the K+ activation of Na,K pumps. These data document for the first time the membrane topology, the specificity of association and a potential functional role for the gamma subunit of Na,K-ATPase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correct positioning of the tibial component in total knee arthroplasty (TKA) must take into account both an optimal bone coverage (defined by a maximal cortical bearing with posteromedial and anterolateral support) and satisfactory patellofemoral tracking. Consequently, a compromise position must be found by the surgeon during the operation to simultaneously meet these two requirements. Moreover, tibial tray positioning depends upon the tibial torsion, which has been shown to act mainly in the proximal quarter of the tibia. Therefore, the correct application of the tibial tray is also theoretically related to the level of bone resection. In this study, we first quantified the torsional profile given by an optimal bone coverage for a symmetrical tibial tray design and for an asymmetrical one. Then, for the two types of tibial trays, we measured the angle difference between optimal bone coverage and an alignment on the middle of the tibial tubercule. Results showed that the values of the torsional profile given by the symmetrical tray were more scattered than those from the asymmetrical one. However, determination of the mean differential angle between the position providing optimal bone coverage and the one providing the best patellofemoral tracking indicated that the symmetrical prosthetic tray offered the best compromise between these two requirements. Although the tibiofemoral joint is known to be asymmetric in both shape and dimension, the asymmetrical tray chosen in this study was found to fulfill this compromise with more difficulty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnosis of several neurological disorders is based on the detection of typical pathological patterns in the electroencephalogram (EEG). This is a time-consuming task requiring significant training and experience. Automatic detection of these EEG patterns would greatly assist in quantitative analysis and interpretation. We present a method, which allows automatic detection of epileptiform events and discrimination of them from eye blinks, and is based on features derived using a novel application of independent component analysis. The algorithm was trained and cross validated using seven EEGs with epileptiform activity. For epileptiform events with compensation for eyeblinks, the sensitivity was 65 +/- 22% at a specificity of 86 +/- 7% (mean +/- SD). With feature extraction by PCA or classification of raw data, specificity reduced to 76 and 74%, respectively, for the same sensitivity. On exactly the same data, the commercially available software Reveal had a maximum sensitivity of 30% and concurrent specificity of 77%. Our algorithm performed well at detecting epileptiform events in this preliminary test and offers a flexible tool that is intended to be generalized to the simultaneous classification of many waveforms in the EEG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cDNA encoding the NH2-terminal 589 amino acids of the extracellular domain of the human polymeric immunoglobulin receptor was inserted into transfer vectors to generate recombinant baculo- and vaccinia viruses. Following infection of insect and mammalian cells, respectively, the resulting truncated protein corresponding to human secretory component (hSC) was secreted with high efficiency into serum-free culture medium. The Sf9 insect cell/baculovirus system yielded as much as 50 mg of hSC/liter of culture, while the mammalian cells/vaccinia virus system produced up to 10 mg of protein/liter. The M(r) of recombinant hSC varied depending on the cell line in which it was expressed (70,000 in Sf9 cells and 85-95,000 in CV-1, TK- 143B and HeLa). These variations in M(r) resulted from different glycosylation patterns, as evidenced by endoglycosidase digestion. Efficient single-step purification of the recombinant protein was achieved either by concanavalin A affinity chromatography or by Ni(2+)-chelate affinity chromatography, when a 6xHis tag was engineered to the carboxyl terminus of hSC. Recombinant hSC retained the capacity to specifically reassociate with dimeric IgA purified from hybridoma cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To date, state-of-the-art seismic material parameter estimates from multi-component sea-bed seismic data are based on the assumption that the sea-bed consists of a fully elastic half-space. In reality, however, the shallow sea-bed generally consists of soft, unconsolidated sediments that are characterized by strong to very strong seismic attenuation. To explore the potential implications, we apply a state-of-the-art elastic decomposition algorithm to synthetic data for a range of canonical sea-bed models consisting of a viscoelastic half-space of varying attenuation. We find that in the presence of strong seismic attenuation, as quantified by Q-values of 10 or less, significant errors arise in the conventional elastic estimation of seismic properties. Tests on synthetic data indicate that these errors can be largely avoided by accounting for the inherent attenuation of the seafloor when estimating the seismic parameters. This can be achieved by replacing the real-valued expressions for the elastic moduli in the governing equations in the parameter estimation by their complex-valued viscoelastic equivalents. The practical application of our parameter procedure yields realistic estimates of the elastic seismic material properties of the shallow sea-bed, while the corresponding Q-estimates seem to be biased towards too low values, particularly for S-waves. Given that the estimation of inelastic material parameters is notoriously difficult, particularly in the immediate vicinity of the sea-bed, this is expected to be of interest and importance for civil and ocean engineering purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Performing total knee replacement, accurate alignment and neutral rotation of the femoral component are widely believed to be crucial for the ultimate success. Contrary to absolute bone referenced alignment, using a ligament balancing technique does not automatically rotate the femoral component parallel to the transepicondylar axis. In this context we established the hypothesis that rotational alignment of the femoral component parallel to the transepicondylar axis (0° ± 3°) results in better outcome than alignment outside of this range. METHODS: We analysed 204 primary cemented mobile bearing total knee replacements five years postoperatively. Femoral component rotation was measured on axial radiographs using the condylar twist angle (CTA). Knee society score, range of motion as well as subjective rating documented outcome. RESULTS: In 96 knees the femoral component rotation was within the range 0 ± 3° (neutral rotation group), and in 108 knees the five-year postoperative rotational alignment of the femoral component was outside of this range (outlier group). Postoperative CTA showed a mean of 2.8° (±3.4°) internal rotation (IR) with a range between 6° external rotation (ER) and 15° IR (CI 95). No difference with regard to subjective and objective outcome could be detected. CONCLUSION: The present work shows that there is a large given natural variability in optimal rotational orientation, in this study between 6° ER and 15° IR, with numerous co-factors determining correct positioning of the femoral component. Further studies substantiating pre- and postoperative determinants are required to complete the understanding of resulting biomechanics in primary TKA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glioblastoma (GBM) is a morphologically heterogeneous tumor type with a median survival of only 15 months in clinical trial populations. However, survival varies greatly among patients. As part of a central pathology review, we addressed the question if patients with GBM displaying distinct morphologic features respond differently to combined chemo-radiotherapy with temozolomide. Morphologic features were systematically recorded for 360 cases with particular focus on the presence of an oligodendroglioma-like component and respective correlations with outcome and relevant molecular markers. GBM with an oligodendroglioma-like component (GBM-O) represented 15% of all confirmed GBM (52/339) and was not associated with a more favorable outcome. GBM-O encompassed a pathogenetically heterogeneous group, significantly enriched for IDH1 mutations (19 vs. 3%, p = 0.003) and EGFR amplifications (71 vs. 48%, p = 0.04) compared with other GBM, while co-deletion of 1p/19q was found in only one case and the MGMT methylation frequency was alike (47 vs. 46%). Expression profiles classified most of the GBM-O into two subtypes, 36% (5/14 evaluable) as proneural and 43% as classical GBM. The detection of pseudo-palisading necrosis (PPN) was associated with benefit from chemotherapy (p = 0.0002), while no such effect was present in the absence of PPN (p = 0.86). In the adjusted interaction model including clinical prognostic factors and MGMT status, PPN was borderline nonsignificant (p = 0.063). Taken together, recognition of an oligodendroglioma-like component in an otherwise classic GBM identifies a pathogenetically mixed group without prognostic significance. However, the presence of PPN may indicate biological features of clinical relevance for further improvement of therapy.