122 resultados para Cervical invasion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of liposomes as carriers for the delivery of biologically active molecules into the eye is of major interest. Indeed, encapsulation of biologically active molecules in liposomes may increase their bioavailability and may induce a sustained release, thus avoiding repeated intraocular injections and reducing side effects. We describe here the fate of rhodamine-conjugated liposomes (Rh-Lip) injected into the vitreous of normal Lewis rats. Twenty-four hours after intravitreal injection fluorescent liposomes were detected in the vitreous, the inner layer of the retina and to a lesser extent in the anterior segment of the eye. In addition, numerous Rh-Lip were also observed in the episclera and conjunctival stroma, in conjunctival lymphatic vessels and cervical lymph nodes (LN) draining the conjunctiva and the eye. In the LN, Rh-Lip were taken up by resident macrophages adjacent to CD4+ and CD8+ T cells. Thus, intravitreal injection of anti-inflammatory drugs loaded in liposomes could modulate the ocular immune microenvironment. In addition the passage of drugs into the cervical LN could alter the immune status of these LN and contribute to the regulation of intraocular inflammation. Our results suggest that this phenomenon should be taken into account to design new therapies based on intraocular drug administration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RAPPORT DE SYNTHÈSE : Chez les patients présentant une pathologie de la colonne cervicale, l'instrumentation des voies aériennes peut s'avérer délicate. En effet, l'impossibilité d'effectuer une extension de la nuque afin d'aligner correctement l'axe oro-pharyngo-trachéal, ainsi que l'ouverture de bouche limitée par la présence d'une minerve cervicale, rendent la laryngoscopie standard extrêmement difficile. Le but de cette étude est de démontrer que l'intubation oro-trachéale avec une minerve cervicale semi-rigide est possible à l'aide d'un vidéolaryngoscope récemment développé, le GlideScope®. Celui-ci est formé d'une lame courbe présentant une angulation accentuée à 60° à partir de son milieu, avec une petite caméra haute résolution et une source lumineuse enchâssées dans la partie inférieure au point d'inflexion. Différents travaux ont montré les avantages du GlideScope® par rapport à la lame de Macintosh standard "pour l'instrumentation des voies aériennes de routine ou en situation difficile. Après acceptation par la Commission d'Ethique, 50 patients, adultes consentants et programmés pour une intervention chirurgicale élective nécessitant une anesthésie générale ont été inclus dans cette étude. Malgré la présence d'une minerve cervicale semi-rigide Philadelphia® Patriot correctement positionnée et la tête fixée à la table d'opération, tous les patients ont pu être intubés a l'aide du GlideScope®. Aucune complication n'a été documentée pendant la procédure ou en post-opératoire. De plus, nous avons démontré que dans cette situation la visualisation des structures laryngées est significativement améliorée grâce au GlideScope®, par rapport à la lame de Macintosh utilisée lors de toute intubation standard. En conclusion, l'intubation oro-trachéale chez les patients ayant une minerve cervicale et la tête fixée est possible à l'aide du GlideScope®. La meilleure façon de sécuriser les voies aériennes chez les patients présentant une instabilité de la colonne cervicale est un sujet fortement débattu. L'utilisation du GlideScope® pourrait s'avérer une alternative intéressante, en particulier dans les situations d'urgence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Application of cervical collars may reduce cervical spine movements but render tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesised that despite the presence of a Philadelphia Patriot (R) cervical collar and with the patient's head taped to the trolley, tracheal intubation would be possible in 50 adult patients using the GlideScope (R) and its dedicated stylet. Laryngoscopy was attempted using a Macintosh laryngoscope with a size 4 blade, and the modified Cormack-Lehane grade was scored. Subsequently, laryngoscopy with the GlideScope was graded and followed by tracheal intubation. All patients' tracheas were successfully intubated with the GlideScope. The median (IQR) intubation time was 50 s (43-61 s). The modified Cormack-Lehane grade was 3 or 4 at direct laryngoscopy. It was significantly reduced with the GlideScope (p < 0.0001), reaching grade 2a in most patients. Tracheal intubation in patients wearing a semi-rigid collar and having their head taped to the trolley is possible with the help of the GlideScope.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: L'ossification du ligament commun vertébral postérieur (LCVP) est une hyperostose prédominant au rachis cervical, associée à différentes pathologies constructrices comme l'arthrose, la maladie de Forestier (ou DISH : Diffuse Idiopathic Squeletal Hyperostosis) ou les spondylarthrites (1). Nous rapportons le cas d'une patiente avec ossification cervicale du LCVP, avec coexistence de DISH et de spondylarthrite.Observation: Patiente de 55 ans, d'origine Irakienne, qui présente depuis l'âge de 40 ans des lombalgies et des talalgies attribuées initialement à un métier physique. En 2008, apparait une cervicobrachialgie C6 gauche. L'IRM cervicale retrouve plusieurs hernies discales (C5-C6 et C6-C7 gauches) avec un canal cervical étroit constitutionnel et une ossification du LCVP cervical. Cette ossification est attribuée à un DISH (Figure1). L'échec du traitement conservateur de la névralgie et la menace neurologique de l'ossification du LCVP conduisent en 2010 à une laminectomie C3-C6 avec fixation postérieure (figure 2). En 2011, la patiente consulte en raison de la persistance de cette névralgie, ainsi que pour des lombalgies inflammatoires. La coexistence de ces symptômes inflammatoires et de l'ossification du LCVP nous incite à réaliser une IRM des sacroiliaques qui retrouve une sacroiliite bilatérale (figure 3). Le diagnostic de spondylarthrite HLA B27 négative est retenu devant l'association des signes cliniques et radiologiques. L'étiologie précise quant à l'origine de l'ossification du LCVP reste incertaine, néanmoins un traitement spécifique de la spondylarthopathie est proposé.Discussion: L'ossification du ligament vertébral commun postérieur est une hyperostose dont les principales causes sont le DISH et les spondylarthrites. On retrouve une ossification du ligament commun vertébral, qu'il soit lombaire, cervical ou dorsal, dans 10 à 50 % des DISH, et 3.5 à 30% des spondylarthrites. 4 types d'ossification du LCVP sont décrites : continue, segmentaire, mixte ou circonscrite. Selon Resnick, le DISH se différencie de la spondylarthrite par la présence d'ossifications antérolatérales d'au moins 4 vertèbres contigües sans érosion des sacroiliaques. Cependant on retrouve dans la littérature quelques cas décrivant la coexistence des 2 pathologies. Récemment, Kim et al. Ont rapporté un cas similaire à notre patiente, avec ossification du LCVP cervical et coexistence de DISH et de spondylarthrite (2).Conclusion: Devant la présence d'une ossification du ligament vertébral commun postérieur cervical, il convient de rechercher des signes de DISH et de spondylarthrite, car leur coexistence est possible. La prévalence exacte de cette association reste encore à déterminer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECT Monoenergetic imaging with dual-energy CT has been proposed to reduce metallic artifacts in comparison with conventional polychromatic CT. The purpose of this study is to systematically evaluate and define the optimal dual-energy CT imaging parameters for specific cervical spinal implant alloy compositions. METHODS Spinal fixation rods of cobalt-chromium or titanium alloy inserted into the cervical spine section of an Alderson Rando anthropomorphic phantom were imaged ex vivo with fast-kilovoltage switching CT at 80 and 140 peak kV. The collimation width and field of view were varied between 20 and 40 mm and medium to large, respectively. Extrapolated monoenergetic images were generated at 70, 90, 110, and 130 kiloelectron volts (keV). The standard deviation of voxel intensities along a circular line profile around the spine was used as an index of the magnitude of metallic artifact. RESULTS The metallic artifact was more conspicuous around the fixation rods made of cobalt-chromium than those of titanium alloy. The magnitude of metallic artifact seen with titanium fixation rods was minimized at monoenergies of 90 keV and higher, using a collimation width of 20 mm and large field of view. The magnitude of metallic artifact with cobalt-chromium fixation rods was minimized at monoenergies of 110 keV and higher; collimation width or field of view had no effect. CONCLUSIONS Optimization of acquisition settings used with monoenergetic CT studies might yield reduced metallic artifacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spinal cord compression due to cervical exostoses is a rare but recognized complication of hereditary multiple exostosis (HME), an autosomal dominant disorder. This disease, also called multiple osteochondromatosis, is characterised by osteocartilaginous exostoses, typically involving the juxtaepiphyseal regions of long bones. Complications such as transformation to sarcoma (1 to 5%) or neurological compression (of the spinal cord, 1 to 9%) can arise during the course of the disease. We report the case of a 64-year-old man with progressive difficulties in walking over many years, ascribed to congenital rachitism. A diagnosis of HME was not made until late in the disease course. Investigations revealed cervical myelopathy due to vertebral exostosis as well as multiple exostoses in other sites. His gait was not improved after surgical decompression. A better knowledge of this disease could have prevented this neurological complication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the diagnostic value of previously described MR features used for detecting suspected placental invasion according to observers' experience. MATERIALS AND METHODS: Our population included 25 pregnant women (mean age 35.16) investigated by prenatal MRI (1.5T, T1- and T2-weighted MR-sequences without i.v. contrast), among them 12 with histopathologically proven placental invasion and 13 women (52%) without placental invasion used as control group. Two senior and two junior radiologists blindly and independently reviewed MR-examinations in view of 6 previously defined MR-features indicating presence and degree of placental invasion (placenta increta, accreta or percreta). For each reader the sensibility, specificity, and receiver operating curve (ROC) were calculated. Interobserver agreements between senior and junior readers were determined. Stepwise logistic regression was performed including the 6 MR-features predictive of placental invasion. RESULTS: Demographics between both groups were statistically equivalent. Overall sensitivity and specificity for placental invasion was 90.9% and 75.0% for seniors and 81.8% and 61.8% for juniors, respectively. The best single MR-feature indicating placental invasion was T2-hypointense placental bands (r(2)=0.28), followed by focally interrupted myometrial border, infiltration of pelvic organs and tenting of the bladder (r(2)=0.36). Interobserver agreement for detecting placental invasion was 0.64 for seniors and 0.41 for juniors, thus substantial and moderate, respectively. Seniors detected placental invasion and depth of infiltration with significantly higher diagnostic certitude than juniors (p=0.0002 and p=0.0282, respectively). CONCLUSION: MRI can be a reliable and reproducible tool for the detection of suspected placental invasion, but the diagnostic value significantly depends on observers' experience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In patients with cervical spine injury, a cervical collar may prevent cervical spine movements but renders tracheal intubation with a standard laryngoscope difficult if not impossible. We hypothesized that despite the presence of a semi-rigid cervical collar and with the patient's head taped to the trolley, we would be able to intubate all patients with the GlideScopeR and its dedicated stylet. Methods: 50 adult patients (ASA 1 or 2, BMI ≤35 kg/m2) scheduled for elective surgical procedures requiring tracheal intubation were included. After standardized induction of general anesthesia and neuromuscular blockade, the neck was immobilized with an appropriately sized semi-rigid Philadelphia Patriot® cervical collar, the head was taped to the trolley. Laryngoscopy was attempted using a Macintosh laryngoscope blade 4 and the modified Cormack Lehane grade was noted. Subsequently, laryngoscopy with the GlideScopeR was graded and followed by oro-tracheal intubation. Results: All patients were successfully intubated with the GlideScopeR and its dedicated stylet. The median intubation time was 50 sec [43; 61]. The modified Cormack Lehane grade was 3 or 4 at direct laryngoscopy. It was significantly reduced with the GlideScopeR (p <0.0001), reaching 2a in most of patients. Maximal mouth opening was significantly reduced with the cervical collar applied, 4.5 cm [4.5; 5.0] vs. 2.0 cm [1.8; 2.0] (p <0.0001). Conclusions: The GlideScope® allows oro-tracheal intubation in patients having their cervical spine immobilized by a semi-rigid collar and their head taped to the trolley. It furthermore decreases significantly the modified Cormack Lehane grade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To carry out a meta-analysis in order to assess the influencing factors on retention loss and marginal discoloration of cervical restorations made of composites and glass ionomer (derivates). METHODS: The literature was searched for prospective clinical studies on cervical restorations with an observation period of at least 18 months. RESULTS: Fifty clinical studies involving 40 adhesive systems matched the inclusion criteria. On average, 10% of the cervical fillings were lost and 24% exhibited marginal discoloration after 3 years. The variability ranged from 0% to 50% for retention loss and from 0% to 74% for marginal discoloration. Hardly any secondary caries was detected. When linear mixed models with a study and experiment effect were used, the analysis revealed that the adhesive/restorative class had the most significant influence, with 2-step self-etching adhesive systems performing best and 1-step self-etching adhesive systems performing worst; 3-step etch-and-rinse systems, glass ionomers/resin-modified glass ionomers, 2-step etch-and-rinse systems and polyacid-modified resin composites were ranked in between. Restorations placed in teeth whose dentin/enamel had been prepared/roughened showed a statistically significant higher retention rate than those placed in teeth with unprepared dentin (p<0.05). Beveling of the enamel and the type of isolation used (rubberdam/cotton rolls) had no significant influence. SIGNIFICANCE: The clinical performance of cervical restorations is significantly influenced by the type of adhesive system used and/or the adhesive class to which the system belonged and whether the dentin/enamel is prepared or not. 2-Step self-etching- and 3-step etch&rinse systems shall be chosen over 1-step self-etching systems and glass ionomer derivates. The dentin (and enamel) surface shall be roughened before placement of the restoration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiotherapy is widely used to treat human cancer. Patients locally recurring after radiotherapy, however, have increased risk of metastatic progression and poor prognosis. The clinical management of postradiation recurrences remains an unresolved issue. Tumors growing in preirradiated tissues have an increased fraction of hypoxic cells and are more metastatic, a condition known as tumor bed effect. The transcription factor hypoxia inducible factor (HIF)-1 promotes invasion and metastasis of hypoxic tumors, but its role in the tumor bed effect has not been reported. Here, we show that tumor cells derived from SCCVII and HCT116 tumors growing in a preirradiated bed, or selected in vitro through repeated cycles of severe hypoxia, retain invasive and metastatic capacities when returned to normoxia. HIF activity, although facilitating metastatic spreading of tumors growing in a preirradiated bed, is not essential. Through gene expression profiling and gain- and loss-of-function experiments, we identified the matricellular protein CYR61 and alphaVbeta5 integrin as proteins cooperating to mediate these effects. The anti-alphaV integrin monoclonal antibody 17E6 and the small molecular alphaVbeta3/alphaVbeta5 integrin inhibitor EMD121974 suppressed invasion and metastasis induced by CYR61 and attenuated metastasis of tumors growing within a preirradiated field. These results represent a conceptual advance to the understanding of the tumor bed effect and identify CYR61 and alphaVbeta5 integrin as proteins that cooperate to mediate metastasis. They also identify alphaV integrin inhibition as a potential therapeutic approach for preventing metastasis in patients at risk for postradiation recurrences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Iterative reconstruction (IR) techniques reduce image noise in multidetector computed tomography (MDCT) imaging. They can therefore be used to reduce radiation dose while maintaining diagnostic image quality nearly constant. However, CT manufacturers offer several strength levels of IR to choose from. PURPOSE: To determine the optimal strength level of IR in low-dose MDCT of the cervical spine. MATERIAL AND METHODS: Thirty consecutive patients investigated by low-dose cervical spine MDCT were prospectively studied. Raw data were reconstructed using filtered back-projection and sinogram-affirmed IR (SAFIRE, strength levels 1 to 5) techniques. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at C3-C4 and C6-C7 levels. Two radiologists independently and blindly evaluated various anatomical structures (both dense and soft tissues) using a 4-point scale. They also rated the overall diagnostic image quality using a 10-point scale. RESULTS: As IR strength levels increased, image noise decreased linearly, while SNR and CNR both increased linearly at C3-C4 and C6-C7 levels (P < 0.001). For the intervertebral discs, the content of neural foramina and dural sac, and for the ligaments, subjective image quality scores increased linearly with increasing IR strength level (P ≤ 0.03). Conversely, for the soft tissues and trabecular bone, the scores decreased linearly with increasing IR strength level (P < 0.001). Finally, the overall diagnostic image quality scores increased linearly with increasing IR strength level (P < 0.001). CONCLUSION: The optimal strength level of IR in low-dose cervical spine MDCT depends on the anatomical structure to be analyzed. For the intervertebral discs and the content of neural foramina, high strength levels of IR are recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE.: Injection of opioids to the superior cervical ganglion (SCG) has been reported to provide pain relief in patients suffering from different kinds of neuropathic facial pain conditions, such as trigeminal neuralgia, postherpetic neuralgia, and atypical facial pain. The classic approach to the SCG is a transoral technique using a so-called "stopper" to prevent accidental carotid artery puncture. The main disadvantage of this technique is that the needle tip is positioned distant from the actual target, possibly impeding successful block of the SCG. A further limitation is that injection of local anesthetics due to potential carotid artery puncture is contraindicated. We hypothesized that the SCG can be identified and blocked using ultrasound imaging, potentially increasing precision of this technique. INTERVENTIONS.: In this pilot study, 20 US-guided simulated blocks of the SCG were performed in 10 human cadavers in order to determine the accuracy of this novel block technique. After injection of 0.1 mL of dye, the cadavers were dissected to evaluate the needle position and coloring of the SCG. RESULTS.: Nineteen of the 20 needle tips were located in or next to the SCG. This corresponded to a simulated block success rate of 95% (95% confidence interval 85-100%). In 17 cases, the SCG was completely colored, and in two cases, the caudal half of the SCG was colored with dye. CONCLUSIONS.: The anatomical dissections confirmed that our ultrasound-guided approach to the SCG is accurate. Ultrasound could become an attractive alternative to the "blind" transoral technique of SCG blocks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the diagnostic value of 18F-FDG PET/CT versus contrastenhanced CT in identifying chest wall invasion by NSCLC. Methods and Materials: The primary selection criterion was a peripheral tumor of any size with contact to the chest wall. A total of 25 patients with pathologically proven NSCLC satisfied these criteria. Chest wall invasion was interpreted upon PET/CT when a frank costal or intercostal 18F-FDG uptake was identified with or without concomitant morphologic alterations. On the other hand, the existence of periosteal rib reaction/erosion, chest wall thickening or obliteration of the pleural fat layer either separately or combined were considered essential diagnostic criteria for disease extension into the chest wall upon contrast-enhanced CT. The results were correlated with the final histological analysis. Results: Among the studied cohort, 13/25 (52%) patients had chest wall invasion consistent with T3 disease. Both PET/CT and contrast-enhanced CT successfully identified 12/13 (92%) of these patients. The single false-negative result was due to parietal pleural invasion. On the other hand, one false-positive result was encountered by PET/CT in a dyspneic patient; whereas, CT analysis revealed false-positive results in six patients. In these patients, periosteal rib reaction (n = 2) or asymmetric enlargement of adjacent chest wall muscles (n = 1) were identified along with an obliterated pleural fat layer (n = 6). The sensitivity, specificity, and accuracy of PET/CT and contrast-enhanced CT were 92, 91 and 92% versus 92, 50 and 72%. Conclusion: 18F-FDG PET/CT is an accurate diagnostic modality in identifying.