72 resultados para CLINICIAN


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Perioperative fluid accumulation determination is a challenge for the clinician. Bioelectrical impedance analysis (BIA) is a noninvasive method based on the electrical properties of tissues, which can assess body fluid compartments. The study aimed at assessing their changes in three types of surgery (thoracic, abdominal, and intracranial) requiring various regimens of fluid administration. DESIGN: Prospective descriptive trial. PATIENTS: A total of 26 patients scheduled for elective surgery were separated into three groups according to site of surgery: thoracic (n = 8), abdominal aortic (n = 8), and brain surgery (n = 10). SETTING: University teaching hospital. INTERVENTION: None. MEASUREMENTS: Whole body, segmental (arm, trunk, and legs) BIA at multiple frequency (0.5, 50, 100 kHz) was used to assess perioperative fluid accumulation after surgery. The fluid balances were calculated from the charts. RESULTS: The patients were aged 62+/-4 yrs. Fluid balances were 4.8+/-1.0 L, 4.1+/-0.5 L, and 1.9+/-0.3 L, respectively, in the three groups. In trunk surgery patients, fluid accumulation was detected as a drop in impedance in the operated area at all frequencies. In the operated area, there was an expansion of both intra- and extracellular compartments. A reduction in high frequencies' impedance in the legs was only detected after aortic surgery. Fluid accumulation and trunk impedance changes were strongly correlated. Neurosurgery only induced minor body fluid changes. CONCLUSIONS: Segmental BIA is able to detect and localize perioperative fluid accumulation. It may become a bedside tool to quantify and to localize fluid accumulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To produce age-related normograms for serum antimullerian hormone (AMH) level in infertile women without polycystic ovaries (non-PCO).Design: Retrospective cohort analysis.Setting: Fifteen academic reproductive centers.Patient(s): A total of 3,871 infertile women.Intervention(s): Blood sampling for AMH level.Main Outcome Measure(s): Serum AMH levels and correlation between age and different percentiles of AMH.Result(s): Age-related normograms for the 3rd, 10th, 25th, 50th, 75th, 90th, and 97th percentiles of AMH were produced. We found that the curves of AMH by age for the 3rd to 50th percentiles fit the model and appearance of linear relation, whereas the curves of >75th percentiles fit cubic relation. There were significant differences in AMH and FSH levels and in antral follicle count (AFC) among women aged 24-33 years, 34-38 years, and >= 39 years. Multivariate stepwise linear regression analysis of FSH, age, AFC, and the type of AMH kit as predictors of AMH level shows that all variables are independently associated with AMH level, in the following order: AFC, FSH, type of AMH kit, and age.Conclusion(s): Age-related normograms in non-PCO infertile women for the 3rd to 97th percentiles were produced. These normograms could provide a reference guide for the clinician to consult women with infertility. However, future validation with longitudinal data is still needed. (Fertil Steril (R) 2011; 95: 2359-63. (C) 2011 by American Society for Reproductive Medicine.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: We set out to determine if insertion of a retropubic tension-free vaginal tape (TVT) sling at the time of pelvic organ prolapse surgery improves continence outcomes in women with pre-operative occult stress incontinence (OSI) or asymptomatic urodynamic stress incontinence (USI). METHODS: We conducted a randomised controlled study of prolapse surgery with or without a TVT midurethral sling. The pre- and post-operative assessment at 6 months included history, physical examination and urodynamic testing. Quality of life (QOL) and treatment success was assessed with the UDI-6 SF, IIQ-7 SF and a numerical success score. The primary outcome was symptomatic stress urinary incontinence (SUI) requiring continence surgery (TVT) at 6 months. Long-term follow-up continued to a minimum of 24 months. Secondary outcomes were quality of life parameters. RESULTS: Eighty women received prolapse surgery alone (n = 43) or prolapse surgery with concurrent TVT (n = 37). Six months following prolapse surgery 3 out of 43 (7 %) patients in the no TVT group requested sling surgery compared with 0 out of 37 (0 %) in the TVT group (ARR 7 % [95 %CI: 3 to 19 %], p = 0.11). After 24 months there was one further participant in the no TVT group who received a TVT for treatment of SUI compared with none in the TVT group (4 out of 43, 9.3 % versus 0 out of 37; ARR 9.3 % [95 %CI: -1 to 22 %], p = 0.06). Both groups showed improvement in QOL difference scores for within-group analysis, without difference between groups. CONCLUSION: These results support a policy that routine insertion of a sling in women with OSI at the time of prolapse repair is questionable and should be subject to shared decision-making between clinician and patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this exploratory study was to assess the impact of clinicians' defense mechanisms-defined as self-protective psychological mechanisms triggered by the affective load of the encounter with the patient-on adherence to a communication skills training (CST). The population consisted of oncology clinicians (N = 31) who participated in a CST. An interview with simulated cancer patients was recorded prior and 6 months after CST. Defenses were measured before and after CST and correlated with a prototype of an ideally conducted interview based on the criteria of CST-teachers. Clinicians who used more adaptive defense mechanisms showed better adherence to communication skills after CST than clinicians with less adaptive defenses (F(1, 29) = 5.26, p = 0.03, d = 0.42). Improvement in communication skills after CST seems to depend on the initial levels of defenses of the clinician prior to CST. Implications for practice and training are discussed. Communication has been recognized as a central element of cancer care [1]. Ineffective communication may contribute to patients' confusion, uncertainty, and increased difficulty in asking questions, expressing feelings, and understanding information [2, 3], and may also contribute to clinicians' lack of job satisfaction and emotional burnout [4]. Therefore, communication skills trainings (CST) for oncology clinicians have been widely developed over the last decade. These trainings should increase the skills of clinicians to respond to the patient's needs, and enhance an adequate encounter with the patient with efficient exchange of information [5]. While CSTs show a great diversity with regard to their pedagogic approaches [6, 7], the main elements of CST consist of (1) role play between participants, (2) analysis of videotaped interviews with simulated patients, and (3) interactive case discussion provided by participants. As recently stated in a consensus paper [8], CSTs need to be taught in small groups (up to 10-12 participants) and have a minimal duration of at least 3 days in order to be effective. Several systematic reviews evaluated the impact of CST on clinicians' communication skills [9-11]. Effectiveness of CST can be assessed by two main approaches: participant-based and patient-based outcomes. Measures can be self-reported, but, according to Gysels et al. [10], behavioral assessment of patient-physician interviews [12] is the most objective and reliable method for measuring change after training. Based on 22 studies on participants' outcomes, Merckaert et al. [9] reported an increase of communication skills and participants' satisfaction with training and changes in attitudes and beliefs. The evaluation of CST remains a challenging task and variables mediating skills improvement remain unidentified. We recently thus conducted a study evaluating the impact of CST on clinicians' defenses by comparing the evolution of defenses of clinicians participating in CST with defenses of a control group without training [13]. Defenses are unconscious psychological processes which protect from anxiety or distress. Therefore, they contribute to the individual's adaptation to stress [14]. Perry refers to the term "defensive functioning" to indicate the degree of adaptation linked to the use of a range of specific defenses by an individual, ranging from low defensive functioning when he or she tends to use generally less adaptive defenses (such as projection, denial, or acting out) to high defensive functioning when he or she tends to use generally more adaptive defenses (such as altruism, intellectualization, or introspection) [15, 16]. Although several authors have addressed the emotional difficulties of oncology clinicians when facing patients and their need to preserve themselves [7, 17, 18], no research has yet been conducted on the defenses of clinicians. For example, repeated use of less adaptive defenses, such as denial, may allow the clinician to avoid or reduce distress, but it also diminishes his ability to respond to the patient's emotions, to identify and to respond adequately to his needs, and to foster the therapeutic alliance. Results of the above-mentioned study [13] showed two groups of clinicians: one with a higher defensive functioning and one with a lower defensive functioning prior to CST. After the training, a difference in defensive functioning between clinicians who participated in CST and clinicians of the control group was only showed for clinicians with a higher defensive functioning. Some clinicians may therefore be more responsive to CST than others. To further address this issue, the present study aimed to evaluate the relationship between the level of adherence to an "ideally conducted interview", as defined by the teachers of the CST, and the level of the clinician' defensive functioning. We hypothesized that, after CST, clinicians with a higher defensive functioning show a greater adherence to the "ideally conducted interview" than clinicians with a lower defensive functioning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE : To determine the prevalence of patient-ventilator asynchrony in patients receiving non-invasive ventilation (NIV) for acute respiratory failure. DESIGN : Prospective multicenter observation study. SETTING : Intensive care units in three university hospitals. METHODS: Patients consecutively admitted to ICU were included. NIV, performed with an ICU ventilator, was set by the clinician. Airway pressure, flow, and surface diaphragmatic electromyography were recorded continuously for 30 min. Asynchrony events and the asynchrony index (AI) were determined from visual inspection of the recordings and clinical observation. RESULTS: A total of 60 patients were included, 55% of whom were hypercapnic. Auto-triggering was present in 8 (13%) patients, double triggering in 9 (15%), ineffective breaths in 8 (13%), premature cycling 7 (12%) and late cycling in 14 (23%). An AI > 10%, indicating severe asynchrony, was present in 26 patients (43%), whose median (25-75 IQR) AI was 26 (15-54%). A significant correlation was found between the magnitude of leaks and the number of ineffective breaths and severity of delayed cycling. Multivariate analysis indicated that the level of pressure support and the magnitude of leaks were weakly, albeit significantly, associated with an AI > 10%. Patient comfort scale was higher in pts with an AI < 10%. CONCLUSION: Patient-ventilator asynchrony is common in patients receiving NIV for acute respiratory failure. Our results suggest that leaks play a major role in generating patient-ventilator asynchrony and discomfort, and point the way to further research to determine if ventilator functions designed to cope with leaks can reduce asynchrony in the clinical setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine if, compared to pressure support (PS), neurally adjusted ventilatory assist (NAVA) reduces patient-ventilator asynchrony in intensive care patients undergoing noninvasive ventilation with an oronasal face mask. METHODS: In this prospective interventional study we compared patient-ventilator synchrony between PS (with ventilator settings determined by the clinician) and NAVA (with the level set so as to obtain the same maximal airway pressure as in PS). Two 20-min recordings of airway pressure, flow and electrical activity of the diaphragm during PS and NAVA were acquired in a randomized order. Trigger delay (T(d)), the patient's neural inspiratory time (T(in)), ventilator pressurization duration (T(iv)), inspiratory time in excess (T(iex)), number of asynchrony events per minute and asynchrony index (AI) were determined. RESULTS: The study included 13 patients, six with COPD, and two with mixed pulmonary disease. T(d) was reduced with NAVA: median 35 ms (IQR 31-53 ms) versus 181 ms (122-208 ms); p = 0.0002. NAVA reduced both premature and delayed cyclings in the majority of patients, but not the median T(iex) value. The total number of asynchrony events tended to be reduced with NAVA: 1.0 events/min (0.5-3.1 events/min) versus 4.4 events/min (0.9-12.1 events/min); p = 0.08. AI was lower with NAVA: 4.9 % (2.5-10.5 %) versus 15.8 % (5.5-49.6 %); p = 0.03. During NAVA, there were no ineffective efforts, or late or premature cyclings. PaO(2) and PaCO(2) were not different between ventilatory modes. CONCLUSION: Compared to PS, NAVA improved patient ventilator synchrony during noninvasive ventilation by reducing T(d) and AI. Moreover, with NAVA, ineffective efforts, and late and premature cyclings were absent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The issue of specificity of delusions in schizophrenia is still a matter of debate. The authors analyze the delusion formation in schizophrenia from a prototypical, phenomenological point of view, focusing on the subject's experience. This perspective links delusion formation to the autistic predisposition, which is considered here as the elementary phenotypic expression of the vulnerability to schizophrenia. Autism is viewed as a defective preconceptual (i.e., before language) attunement to the world. It impedes the individual's sharing of "common sense" with others and impairs the ability to project into the future. The development of delusions is illustrated, in part, by Klaus Conrad's work on the onset of paranoid schizophrenia. Delusions are viewed as transformations of the structure of experiencing. When threatened in future ability to be, the autistic, vulnerable person looks for the clues to becoming by attributing significance to disparate elements of the environment, which become self-referential. The link established between these disparate elements is based on universal characteristics that give the schizophrenic delusion a metaphysical quality. The transitivistic experience in delusions of control and omnipotence points to a specific way of crossing the border between "mine" and "yours" (disturbances of the experiencing "I"). What strikes a clinician in these delusions is that the normally tacit link between the sense of being and the sense of acting becomes quite apparent. The authors also propose a specificity in the themes of schizophrenic delusions. Delusions acquire a schizophrenic quality when ontological (i.e., universal) elements of the discourse between the locutor and the Other dominate at the expense of the worldly elements. It is emphasized that delusional content and form are dialectically related and hardly distinguishable. The authors consider the delusion formation as a phenomenon of emergence, a situation in which a new qualitative order arises from the reorganization of essentially unchanged elements. To consider schizophrenia as an emergent, particular way of experiencing, related to the autistic defect, has important consequences for research and for treatment. A dialectic exchange is needed between prototypical models generated by phenomenological inquiry and empirical, operational validation of testable aspects of such models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Antipsychotic medication represents the treatment of choice in psychosis according to clinical guidelines. Nevertheless, studies show that half to almost three-quarter of all patients discontinue medication with antipsychotics after some time, a fact which is traditionally ascribed to side-effects, mistrust against the clinician and poor illness insight. The present study investigated whether positive attitudes toward psychotic symptoms (ie, gain from illness) represent a further factor for medication noncompliance. An anonymous online survey was set up in order to prevent conservative response biases that likely emerge in a clinical setting. Following an iterative selection process, data from a total of 113 patients with a likely diagnosis of schizophrenia and a history of antipsychotic treatment were retained for the final analyses (80%). While side-effect profile and mistrust emerged as the most frequent reasons for drug discontinuation, 28% of the sample reported gain from illness (eg, missing voices, feeling of power) as a motive for noncompliance. At least every fourth patient reported the following reasons: stigma (31%), mistrust against the physician/therapist (31%), and rejection of medication in general (28%). Approximately every fifth patient had discontinued antipsychotic treatment because of forgetfulness. On average, patients provided 4 different explanations for noncompliance. Ambivalence toward symptoms and treatment should thoroughly be considered when planning treatment in psychosis. While antipsychotic medication represents the evidence-based cornerstone of the current treatment in schizophrenia, further research is needed on nonpharmacological interventions for noncompliant patients who are willing to undergo intervention but refuse pharmacotherapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION. Neurally Adjusted Ventilatory Assist (NAVA) is a new ventilatory mode in which ventilator settings are adjusted based on the electrical activity detected in the diaphragm (Eadi). This mode offers significant advantages in mechanical ventilation over standard pressure support (PS) modes, since ventilator input is determined directly from patient ventilatory demand. Therefore, it is expected that tidal volume (Vt) under NAVA would show better correlation with Eadi compared with PS, and exhibit greater variability due to the variability in the Eadi input to the ventilator. OBJECTIVES. To compare tidal volume variability in PS and NAVA ventilation modes, and its correlation with patient ventilatory demand (as characterized by maximum Eadi). METHODS. Acomparative study of patient-ventilator interaction was performed for 22 patients during standard PS with clinician determined ventilator settings; and NAVA, with NAVA gain set to ensure the same peak airway pressure as the total pressure obtained in PS. A 20 min continuous recording was performed in each ventilator mode. Respiratory rate, Vt, and Eadi were recorded. Tidal volume variance and Pearson correlation coefficient between Vt and Eadi were calculated for each patient. A periodogram was plotted for each ventilator mode and each patient, showing spectral power as a function of frequency to assess variability. RESULTS. Median, lower quartile and upper quartile values for Vt variance and Vt/Eadi correlation are shown in Table 1. The NAVA cohort exhibits substantially greater correlation and variance than the PS cohort. Power spectrums for Vt and Eadi are shown in Fig. 1 (PS and NAVA) for a typical patient. The enlarged section highlights how changes in Eadi are highly synchronized with NAVA ventilation, but less so for PS. CONCLUSIONS. There is greater variability in tidal volume and correlation between tidal volume and diaphragmatic electrical activity with NAVA compared to PS. These results are consistent with the improved patient-ventilator synchrony reported in the literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of orally active small molecule inhibitors of the epidermal growth factor receptor (EGFR) has led to new treatment options for non-small cell lung cancer (NSCLC). Patients with activating mutations of the EGFR gene show sensitivity to, and clinical benefit from, treatment with EGFR tyrosine kinase inhibitors (EGFR-TKls). First generation reversible ATP-competitive EGFR-TKls, gefitinib and erlotinib, are effective as first, second-line or maintenance therapy. Despite initial benefit, most patients develop resistance within a year, 50-60% of cases being related to the appearance of a T790M gatekeeper mutation. Newer, irreversible EGFR-TKls - afatinib and dacomitinib - covalently bind to and inhibit multiple receptors in the ErbB family (EGFR, HER2 and HER4). These agents have been mainly evaluated for first-line treatment but also in the setting of acquired resistance to first-generation EGFR-TKls. Afatinib is the first ErbB family blocker approved for patients with NSCLC with activating EGFR mutations; dacomitinib is in late stage clinical development. Mutant-selective EGFR inhibitors (AZD9291, CO-1686, HM61713) that specifically target the T790M resistance mutation are in early development. The EGFR-TKIs differ in their spectrum of target kinases, reversibility of binding to EGFR receptor, pharmacokinetics and potential for drug-drug interactions, as discussed in this review. For the clinician, these differences are relevant in the setting of polymedicated patients with NSCLC, as well as from the perspective of innovative anticancer drug combination strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION. Neurally Adjusted Ventilatory Assist (NAVA) is an assisted ventilatorymode in which the ventilator is driven by the electrical activity of the diaphragm (Eadi).NAVAimproves patient-ventilator synchrony [1] but little is known about how to set the NAVA gaini.e., how to choose the ratio between Eadi and delivered pressure. The aim of the present studywas to assess the relationship between Eadi and tidal volume (Vt) at various NAVA gainsettings and to evaluate whether modifying the gain influenced this relationship in non-invasivelyventilated (NIV) patients.METHODS. Prospective interventional study comparing 3 values of NAVA gain during NIV(20 min each). NAVA100 was set by the clinician according to the manufacturer's recommendations.In NAVA50 and NAVA150 the gain was set as -50% and +50% of NAVA100gain respectively. Vt and maximal Eadi value (Eadi max) were recorded. The ratio Vt/Eadi wasthen assessed for each breath. 5-95% range (range 90) of Vt/Eadi was calculated for eachpatient at each NAVA gain setting. Vt/Eadi ratio has the advantage to give an objectiveassessment Vt/Eadi max relationship independently from the nature of this relationship. Asmaller Range90 indicates a better matching of Vt to Eadi max.RESULTS. 12 patients were included, 5 had obstructive pulmonary disease and 2 mixedobstructive and restrictive disease. For NAVA100, the median [IQR] Range 90 was 32[19-87]. For NAVA150 Range 90 was 37 [20-95] and for NAVA50 Range 90 was 33 [16-92].That means that globally NAVA100 allowed a better match between Eadi max and Vt thanNAVA50 and 150. However, by patient, NAVA100 had the lowest Range 90 value for only 4patients (33%), NAVA150 for 2 (17%) and NAVA50 for 6 (50%) patients, indicating thatNAVA100 was not the best NAVA gain for minimizing Range 90 in every patients.Comparing the lowest Range 90 value to the next lowest for each patient, showed that 3 patientshad differences of less than 10% (one each for NAVA50, NAVA100 and NAVA150). Theremainder had differences from 17 to 24%, indicating that most patients (9/12 or 75%) had aclear better match between Eadi and Vt for one specific NAVA gain.CONCLUSIONS. Different NAVA gains yielded markedly different ability to match Vt toEadi max. This approach could be a new way to determine optimalNAVAgain for each patientbut require further investigations.REFERENCE. Piquilloud L, et al. Intensive Care Med 2011;37:263-71.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Assessment of volume status is often challenging in daily clinical practice. One of the clinician's tasks is to prevent or to treat organ systems failures that arise from a mismatch between the transport of oxygen and metabolic needs. Renal failure is a frequently encountered in-hospital diagnosis that is known to alter significantly the prognosis. In patients with acute renal failure in particular, the consequences of an inadequate volume management further increase morbidity and mortality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To document and compare the prevalence of asynchrony events during invasive-assisted mechanical ventilation in pressure support mode and in neurally adjusted ventilatory assist in children. DESIGN: Prospective, randomized, and crossover study. SETTING: Pediatric and Neonatal Intensive Care Unit, University Hospital of Geneva, Switzerland. PATIENTS: Intubated and mechanically ventilated children, between 4 weeks and 5 years old. INTERVENTIONS: Two consecutive ventilation periods (pressure support and neurally adjusted ventilatory assist) were applied in random order. During pressure support, three levels of expiratory trigger setting were compared: expiratory trigger setting as set by the clinician in charge (PSinit), followed by a 10% (in absolute values) increase and decrease of the clinician's expiratory trigger setting. The pressure support session with the least number of asynchrony events was defined as PSbest. Therefore, three periods were compared: PSinit, PSbest, and neurally adjusted ventilatory assist. Asynchrony events, trigger delay, and inspiratory time in excess were quantified for each of them. MEASUREMENTS AND MAIN RESULTS: Data from 19 children were analyzed. Main asynchrony events during PSinit were autotriggering (3.6 events/min [0.7-8.2]), ineffective efforts (1.2/min [0.6-5]), and premature cycling (3.5/min [1.3-4.9]). Their number was significantly reduced with PSbest: autotriggering 1.6/min (0.2-4.9), ineffective efforts 0.7/min (0-2.6), and premature cycling 2/min (0.1-3.1), p < 0.005 for each comparison. The median asynchrony index (total number of asynchronies/triggered and not triggered breaths ×100) was significantly different between PSinit and PSbest: 37.3% [19-47%] and 29% [24-43%], respectively, p < 0.005). With neurally adjusted ventilatory assist, all types of asynchrony events except double-triggering and inspiratory time in excess were significantly reduced resulting in an asynchrony index of 3.8% (2.4-15%) (p < 0.005 compared to PSbest). CONCLUSIONS: Asynchrony events are frequent during pressure support in children despite adjusting the cycling off criteria. Neurally adjusted ventilatory assist allowed for an almost ten-fold reduction in asynchrony events. Further studies should determine the clinical impact of these findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The introduction of the WHO FRAX® algorithms has facilitated the assessment of fracture risk on the basis of fracture probability. Its use in fracture risk prediction has strengths, but also limitations of which the clinician should be aware and are the focus of this review INTRODUCTION: The International Osteoporosis Foundation (IOF) and the International Society for Clinical Densitometry (ISCD) appointed a joint Task Force to develop resource documents in order to make recommendations on how to improve FRAX and better inform clinicians who use FRAX. The Task Force met in November 2010 for 3 days to discuss these topics which form the focus of this review. METHODS: This study reviews the resource documents and joint position statements of ISCD and IOF. RESULTS: Details on the clinical risk factors currently used in FRAX are provided, and the reasons for the exclusion of others are provided. Recommendations are made for the development of surrogate models where country-specific FRAX models are not available. CONCLUSIONS: The wish list of clinicians for the modulation of FRAX is large, but in many instances, these wishes cannot presently be fulfilled; however, an explanation and understanding of the reasons may be helpful in translating the information provided by FRAX into clinical practice.