35 resultados para Aqueous Mixtures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: The use of an animal model to study the aqueous dynamic and the histological findings after deep sclerectomy with (DSCI) and without collagen implant. METHODS: Deep sclerectomy was performed on rabbits' eyes. Eyes were randomly assigned to receive collagen implants. Measurements of intraocular pressure (IOP) and aqueous outflow facility using the constant pressure method through cannulation of the anterior chamber were performed. The system was filled with BSS and cationised ferritin. Histological assessment of the operative site was performed. Sections were stained with haematoxylin and eosin and with Prussian blue. Aqueous drainage vessels were identified by the reaction between ferritin and Prussian blue. All eyes were coded so that the investigator was blind to the type of surgery until the evaluation was completed. RESULTS: A significant decrease in IOP (p<0.05) was observed during the first 6 weeks after DSCI (mean IOP was 13.07 (2.95) mm Hg preoperatively and 9.08 (2.25) mm Hg at 6 weeks); DS without collagen implant revealed a significant decrease in IOP at weeks 4 and 8 after surgery (mean IOP 12.57 (3.52) mm Hg preoperatively, 9.45 (3.38) mm Hg at 4 weeks, and 9.22 (3.39) mm Hg at 8 weeks). Outflow facility was significantly increased throughout the 9 months of follow up in both DSCI and DS groups (p<0.05). The preoperative outflow facility (OF) was 0.15 (0.02) micro l/min/mm Hg. At 9 months, OF was 0.52 (0.28) microl/min/mm Hg and 0.46 (0.07) micro l/min/mm Hg for DSCI and DS respectively. Light microscopy studies showed the appearance of new aqueous drainage vessels in the sclera adjacent to the dissection site in DSCI and DS and the apparition of spindle cells lining the collagen implant in DSCI after 2 months. CONCLUSION: A significant IOP decrease was observed during the first weeks after DSCI and DS. DS with or without collagen implant provided a significant increase in outflow facility throughout the 9 months of follow up. This might be partly explained by new drainage vessels in the sclera surrounding the operated site. Microscopic studies revealed the appearance of spindle cells lining the collagen implant in DSCI after 2 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An EGFP construct interacting with the PIB1000-PEG6000-PIB1000 vesicles surface reported a ~2-fold fluorescence emission enhancement. Because of the constructs nature with the amphiphilic peptide inserted into the PIB core, EGFP is expected to experience a "pure" PEG environment. To unravel this phenomenon PEG/water solutions at different molecular weights and concentrations were used. Already at ~1 : 10 protein/PEG molar ratio the increase in fluorescence emission is observed reaching a plateau correlating with the PEG molecular weight. Parallel experiments in presence of glycerol aqueous solutions did show a slight fluorescence enhancement however starting at much higher concentrations. Molecular dynamics simulations of EGFP in neat water, glycerol, and PEG aqueous solutions were performed showing that PEG molecules tend to "wrap" the protein creating a microenvironment where the local PEG concentration is higher compared to its bulk concentration. Because the fluorescent emission can be perturbed by the refractive index surrounding the protein, the clustering of PEG molecules induces an enhanced fluorescence emission already at extremely low concentrations. These findings can be important when related to the use of EGFP as reported in molecular biology experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contamination with arsenic is a recurring problem in both industrialized and developing countries. Drinking water supplies for large populations can have concentrations much higher than the permissible levels (for most European countries and the United States, 10 μg As per L; elsewhere, 50 μg As per L). Arsenic analysis requires high-end instruments, which are largely unavailable in developing countries. Bioassays based on genetically engineered bacteria have been proposed as suitable alternatives but such tests would profit from better standardization and direct incorporation into sensing devices. The goal of this work was to develop and test microfluidic devices in which bacterial bioreporters could be embedded, exposed and reporter signals detected, as a further step towards a complete miniaturized bacterial biosensor. The signal element in the biosensor is a nonpathogenic laboratory strain of Escherichia coli, which produces a variant of the green fluorescent protein after contact to arsenite and arsenate. E. coli bioreporter cells were encapsulated in agarose beads and incorporated into a microfluidic device where they were captured in 500 × 500 μm(2) cages and exposed to aqueous samples containing arsenic. Cell-beads frozen at -20 °C in the microfluidic chip retained inducibility for up to a month and arsenic samples with 10 or 50 μg L(-1) could be reproducibly discriminated from the blank. In the 0-50 μg L(-1) range and with an exposure time of 200 minutes, the rate of signal increase was linearly proportional to the arsenic concentration. The time needed to reliably and reproducibly detect a concentration of 50 μg L(-1) was 75-120 minutes, and 120-180 minutes for a concentration of 10 μg L(-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genetically constructed microbial biosensors for measuring organic pollutants are mostly applied in aqueous samples. Unfortunately, the detection limit of most biosensors is insufficient to detect pollutants at low but environmentally relevant concentrations. However, organic pollutants with low levels of water solubility often have significant gas-water partitioning coefficients, which in principle makes it possible to measure such compounds in the gas rather than the aqueous phase. Here we describe the first use of a microbial biosensor for measuring organic pollutants directly in the gas phase. For this purpose, we reconstructed a bioluminescent Pseudomonas putida naphthalene biosensor strain to carry the NAH7 plasmid and a chromosomally inserted gene fusion between the sal promoter and the luxAB genes. Specific calibration studies were performed with suspended and filter-immobilized biosensor cells, in aqueous solution and in the gas phase. Gas phase measurements with filter-immobilized biosensor cells in closed flasks, with a naphthalene-contaminated aqueous phase, showed that the biosensor cells can measure naphthalene effectively. The biosensor cells on the filter responded with increasing light output proportional to the naphthalene concentration added to the water phase, even though only a small proportion of the naphthalene was present in the gas phase. In fact, the biosensor cells could concentrate a larger proportion of naphthalene through the gas phase than in the aqueous suspension, probably due to faster transport of naphthalene to the cells in the gas phase. This led to a 10-fold lower detectable aqueous naphthalene concentration (50 nM instead of 0.5 micro M). Thus, the use of bacterial biosensors for measuring organic pollutants in the gas phase is a valid method for increasing the sensitivity of these valuable biological devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relaxivity of commercially available gadolinium (Gd)-based contrast agents was studied for X-nuclei resonances with long intrinsic relaxation times ranging from 6 s to several hundred seconds. Omniscan in pure 13C formic acid had a relaxivity of 2.9 mM(-1) s(-1), whereas its relaxivity on glutamate C1 and C5 in aqueous solution was approximately 0.5 mM(-1) s(-1). Both relaxivities allow the preparation of solutions with a predetermined short T1 and suggest that in vitro substantial sensitivity gains in their measurement can be achieved. 6Li has a long intrinsic relaxation time, on the order of several minutes, which was strongly affected by the contrast agents. Relaxivity ranged from approximately 0.1 mM(-1) s(-1) for Omniscan to 0.3 for Magnevist, whereas the relaxivity of Gd-DOTP was at 11 mM(-1) s(-1), which is two orders of magnitude higher. Overall, these experiments suggest that the presence of 0.1- to 10-microM contrast agents should be detectable, provided sufficient sensitivity is available, such as that afforded by hyperpolarization, recently introduced to in vivo imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To examine the efficacy and safety of Baerveldt shunt (BS) implantation compared to combined phacoemulsification and Baerveldt shunt implantation (PBS). This study was designed to detect a difference in IOP reduction of 20% (~4mmHg) between groups with 90% power. Methods: Sixty patients with medically uncontrolled glaucoma, prospectively underwent either or BS implantation with phacoemulsification (Group PBS; n=30) or BS implantation alone (group BS; n=30, pseudophakic eyes only). Groups were matched for age, glaucoma subtype and length of follow-up. Pre and post-operative measures recorded included patient demographics, visual acuity, IOP, number of glaucoma medications (GMs) and all complications. Success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline with or without GMs. Results: Age of PBS and BS groups was 61 vs 62 years respectively (p=0.72*). There were no significant differences in preoperative baseline characteristics: PBS vs PB, mean IOP =25.5mmHg (standard deviation (SD); ±10.3mmHg) vs 26.1mmHg (SD ±10.6mmHg), p=0.81*; mean GMs=3.0 (SD ±1.1) vs 3.1 (SD ±1.0), p=0.83*; mean VA=0.3 vs 0.3, p=0.89*. At year one there were no significant differences observed between groups in post-operative IOP, GMs or VA, mean IOP =14.1mmHg (SD ±5.4mmHg) vs 11.5 mmHg (SD ±4.2mmHg), p=0.12*; mean GMs=1.6 (SD ±1.4) vs 1.1 (SD ±1.1), p=0.23*; mean VA=0.5 vs 0.4, p=0.46*. Complication rates were similar between the two groups (7% vs 14%). Success rate was lower in eyes with PBS (71%) than with BS (88%), however this did not reach statistical significance (p=0.95, log-rank test). * two-sample t-test Conclusions: There were no significant differences at year one in success or complication rates between PBS and BS groups suggesting that simultaneous phacoemulsification does not have a marked (difference of >4mmHg) effect on tube function. IOP reduction and success were less in the PBS group, a larger sample (n=120) would be required to investigate if there is a 10% difference in IOP reduction between groups, however it is unclear if this would be a clinically significant difference to justify separate surgeries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe the use of anterior segment optical coherence tomography (AS-OCT) to clarify the position and patency of aqueous shunt devices in the anterior chamber of eyes where corneal edema or tube position does not permit a satisfactory view. DESIGN: Noncomparative observational case series. METHODS: Four cases are reported in which aqueous shunt malposition or obstruction was suspected but the shunt could not be seen on clinical examination. The patients underwent AS-OCT to identify the position and patency of the shunt tip. RESULTS: In each case, AS-OCT provided data regarding tube position and/or patency that could not be obtained by slit-lamp examination or by gonioscopy that influenced management. CONCLUSIONS: AS-OCT can be used to visualize anterior chamber tubes in the presence of corneal edema that precludes an adequate view or in cases where the tube is retracted into the cornea. In such cases, AS-OCT is useful in identifying shunt patency and position, which helps guide clinical decision making.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cyclosporine A is a poorly water-soluble, immunosuppressive drug used to treat a variety of ocular diseases. Its limited solubility makes challenging the development of a cyclosporine A-based eye drop for ocular topical application. Based on the prodrug strategy, the practically insoluble cyclosporine A was converted into a freely soluble prodrug. Such a water-soluble prodrug made it possible to develop water-based concentrated eye drops. The prodrug formulations were tested for their ex vivo permeation and in vivo distribution at three concentrations (equivalent to 0.05%, 0.50% and 2.00% w/v cyclosporine A). The ex vivo permeation experiments were performed on corneal and conjunctival epithelia. The in vivo distribution evaluated the total cyclosporine A present in the ocular structures as well as in serum, spleen and cervical lymphatic ganglions. Each prodrug formulation was compared to conventionally used cyclosporine A eye drops at an equivalent concentration. The experimental results showed that the tested eye drops behaved differently. The prodrug formulation was characterized by the following: i) preferential conjunctival penetration, ii) an interesting capacity to create large tissue deposits and iii) a lower risk of systemic complications and immunosuppression. The prodrug aqueous eye drop was demonstrated to be a patient-friendly option for the treatment of ocular diseases requiring high ocular levels of cyclosporine A, pushing the boundaries of the current therapeutic arsenal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lake Geneva is one of the largest European lakes with a surface area of 580 km2. Its catchment area covers 7400 km2, of which approximately 20% is arable land. Monitoring campaigns have been carried out in 2004 and 2005 to determine the contamination of the lake by pesticides. The results highlight the widespread presence of herbicides in water, the measured concentrations for most substances remaining constant in 2004 and 2005. However, for some individual herbicides the concentrations increased drastically (e.g., the herbicide foramsulfuron). We assessed the environmental risk of the herbicides detected in the lake using water quality criteria recently determined for the Swiss environmental protection agency. Furthermore, we assessed the risk of herbicide mixtures, grouped based upon their mode of action. Generally, the risk estimated for all single substances is low, except for some sulfonylurea compounds. For these substances, the measured concentrations are higher than the predicted no-effect concentration. Impact on the flora of the lake can therefore not be excluded. When mixtures of pesticides with similar mode of action are taken into account, the risk remains lower than the mixture water quality criteria for all groups, but can reach as high as one third of this quality criteria. A further step would therefore be to assess the risk of the total pesticide mixture, including similar and dissimilar modes of action.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Aqueous flow through trabeculectomy blebs has been suggested to influence filtration bleb survival. We investigated the relationship between the requirement to increase aqueous flow via adjustable suture removal and surgical outcomes following "safe trabeculectomy" with mitomycin C (MMC). Methods: 62 consecutive eyes of 53 patients underwent fornix based trabeculectomy with adjustable sutures, intraoperative MMC and intensive postoperative steroids. Subconjunctival antimetabolite injections and bleb needlings were administered according to bleb vascularity and IOP trends. Main outcome measures were: success rates (definition: IOP≤21mmHg and 20% IOP reduction); number of antimetabolite injections; bleb needlings; number of of eyes recommencing glaucoma medications and complications. Results: Mean age was 70.4±16.0 years (mean± SD); mean preoperative IOP was 24.5±9.1 mmHg and decreased to 12.3±8.9mmHg postoperatively. Mean number of sutures was 2.6 ± 0.7. Eyes were divided into 2 groups in relation to the number of sutures removed. The number of subconjunctival MMC injections required for those requiring 2 suture removals was significantly greater than those requiring 1 suture removal (p<0.05) The number of needlings and 5FU injections also increased but did not reach significance (p=0.09 and p=0.34 respectively). Least-squared linear regression analysis showed the number of needlings required had a statistically significant (p=0.05) trend with respect to time elapsed between surgery and first suture removal. No other interventions had significant trends. Mean time between surgery and suture removal was: 4.2±9.2 weeks (suture #1) and 5.7±9.7 weeks (suture#2). Antiglaucoma medication was restarted in only 5 eyes. Postoperative complications were infrequent: Seidel (3.2%), peripheral choroidal effusions at any time (3.2%), and shallow anterior chamber (1.6%). Conclusion: Eyes requiring a greater number of suture removals required a significantly greater number of antifibrosis interventions. The time elapsed before suture removal was inversely related to the number of postoperative needlings, suggesting these eyes may have decreased aqueous production and therefore require aggressive post-operative management to prevent bleb failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multicomponent indicator displacement assay ( MIDA) based on an organometallic receptor and three dyes can be used for the identification and quantification of nucleotides in aqueous solution at neutral pH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of the present study was the in vitro and in vivo evaluation of a novel aqueous formulation based on polymeric micelles for the topical delivery of cyclosporine A for dry eye treatment. METHODS: In vitro experiments were carried out on primary rabbit corneal cells, which were characterized by immunocytochemistry using fluorescein-labeled lectin I/isolectin B4 for the endothelial cells and mouse monoclonal antibody to cytokeratin 3+12 for the epithelial ones. Living cells were incubated for 1 hour or 24 hours with a fluorescently labeled micelle formulation and analyzed by fluorescence microscopy. In vivo evaluations were done by Schirmer test, osmolarity measurement, CyA kinetics in tears, and CyA ocular distribution after topical instillation. A 0.05% CyA micelle formulation was compared to a marketed emulsion (Restasis). RESULTS: The in vitro experiments showed the internalization of micelles in the living cells. The Schirmer test and osmolarity measurements demonstrated that micelles did not alter the ocular surface properties. The evaluation of the tear fluid gave similar CyA kinetics values: AUC = 2339 ± 1032 min*μg/mL and 2321 ± 881.63; Cmax = 478 ± 111 μg/mL and 451 ± 74; half-life = 36 ± 9 min and 28 ± 9 for the micelle formulation and Restasis, respectively. The ocular distribution investigation revealed that the novel formulation delivered 1540 ± 400 ng CyA/g tissue to the cornea. CONCLUSIONS: The micelle formulation delivered active CyA into the cornea without evident negative influence on the ocular surface properties. This formulation could be applied for immune-related ocular surface diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To examine the efficacy and safety of repeat deep sclerectomy (DS) versus Baerveldt shunt (BS) implantation as second line surgery following failed primary DS. Methods: Fifty one patients were prospectively recruited to undergo BS implantation following failed DS and 51 patients underwent repeat DS, for which data was collected retrospectively. All eyes had at least one failed DS. Surgical success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline. Success rates, number of glaucoma medications (GMs), IOP, and complication rates were compared between the two groups at year 1, post-operatively. Results: Mean age, sex and the proportion of glaucoma subtypes were similar between groups. Preoperatively IOP was significantly lower in DS group vs BS group (18.8mmHg vs 23.8mmHg, p<0.01, two sample t-test). Postoperatively IOP was significantly higher in DS group than BS group (14.6mmHg vs 12.0mmHg, p<0.01, two-sample t-test). In the DS group, 47% of eyes did not achieve 20% reduction in IOP from baseline, as a result the success rates were significantly lower in eyes with DS (51%) than in eyes with BS (88%) (p=0.02, log-rank test). Preoperatively the number of GMs used in DS and BS groups were similar (2.2 vs 2.7 p=0.02, two sample t-test). Postoperatively there remained no significant difference in GMs between groups (0.9 vs 1.1, p= 0.58, two sample t-test). Complication rates were similar between the two groups (12% vs 10%). Conclusions: Baerveldt tube implantation was more effective in lowering IOP than repeat deep sclerectomy in eyes with failed primary DS, at year one. Complications were minor and infrequent in both groups