164 resultados para Aortic ring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our experience with the Sapien trans-apical aortic valve (Edwards Lifesciences Inc., Irvine, CA, USA) has been straightforward without per-procedural mortality except in 1/16 consecutive cases who developed non-apical haemorrhage early after valve implantation. We describe the case of an 84-year-old female carrying a very high operative risk (logistic EuroScore of 44%), who underwent a trans-apical stent-valve implantation for severe and symptomatic aortic valve stenosis (23 mm). Due to massive blood loss, an emergency sternotomy and cannulation for cardiopulmonary bypass resuscitation were necessary to treat (without success) an unusual and unexpected subaortic left ventricular free-wall rupture that occurred few minutes after the stent-valve positioning and implantation. To the best of our knowledge, this is the first described case of a left ventricular free-wall rupture occurring after an otherwise non-complicated standard catheter-based aortic valve replacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sensitivity of altitudinal and latitudinal tree-line ecotones to climate change, particularly that of temperature, has received much attention. To improve our understanding of the factors affecting tree-line position, we used the spatially explicit dynamic forest model TreeMig. Although well-suited because of its landscape dynamics functions, TreeMig features a parabolic temperature growth response curve, which has recently been questioned. and the species parameters are not specifically calibrated for cold temperatures. Our main goals were to improve the theoretical basis of the temperature growth response curve in the model and develop a method for deriving that curve's parameters from tree-ring data. We replaced the parabola with an asymptotic curve, calibrated for the main species at the subalpine (Swiss Alps: Pinus cembra, Larix decidua, Picea abies) and boreal (Fennoscandia: Pinus sylvestris, Betula pubescens, P. abies) tree-lines. After fitting new parameters, the growth curve matched observed tree-ring widths better. For the subalpine species, the minimum degree-day sum allowing, growth (kDDMin) was lowered by around 100 degree-days; in the case of Larix, the maximum potential ring-width was increased to 5.19 mm. At the boreal tree-line, the kDDMin for P. sylvestris was lowered by 210 degree-days and its maximum ring-width increased to 2.943 mm; for Betula (new in the model) kDDMin was set to 325 degree-days and the maximum ring-width to 2.51 mm; the values from the only boreal sample site for Picea were similar to the subalpine ones, so the same parameters were used. However, adjusting the growth response alone did not improve the model's output concerning species' distributions and their relative importance at tree-line. Minimum winter temperature (MinWiT, mean of the coldest winter month), which controls seedling establishment in TreeMig, proved more important for determining distribution. Picea, P. sylvestris and Betula did not previously have minimum winter temperature limits, so these values were set to the 95th percentile of each species' coldest MinWiT site (respectively -7, -11, -13). In a case study for the Alps, the original and newly calibrated versions of TreeMig were compared with biomass data from the National Forest Inventor), (NFI). Both models gave similar, reasonably realistic results. In conclusion, this method of deriving temperature responses from tree-rings works well. However, regeneration and its underlying factors seem more important for controlling species' distributions than previously thought. More research on regeneration ecology, especially at the upper limit of forests. is needed to improve predictions of tree-line responses to climate change further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevalence of abdominal aortic aneurysm (AAA) and its risk factors are well known in Western countries but few data are available from low- and middle- income countries. We are not aware of systematically collected population- based data on AAA in the African region. We evaluated the prevalence of AAA in a population- based cardiovascular survey conducted in the Republic of Seychelles in 2004 (Indian Ocean, African region). Among the 353 participants aged 50 to 64 years and screened with ultrasound, the prevalence of AAA was 0.3% (95% CI: 0- 0.9) and the prevalence of ectatic dilatations of the abdominal aorta was 1.5% (95% CI: 0.2- 2.8). The prevalence of AAA in the general population seemed lower in Seychelles than in Western countries, despite a high prevalence in Seychelles of risk factors of AAA, such as smoking (in men), high blood pressure and hypercholesterolaemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The trans-apical aortic valve implantation (TA-AVI) is an established technique for high-risk patients requiring aortic valve replacement. Traditionally, preoperative (computed tomography (CT) scan, coronary angiogram) and intra-operative imaging (fluoroscopy) for stent-valve positioning and implantation require contrast medium injections. To preserve the renal function in elderly patients suffering from chronic renal insufficiency, a fully echo-guided trans-catheter valve implantation seems to be a reasonable alternative. We report the first successful TA-AVI procedure performed solely under trans-oesophageal echocardiogram control, in the absence of contrast medium injections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Following open-heart surgery, sternal osteomyelitis or infection of the graft may be a serious complication with high mortality rates. The recommended treatment of an infected graft is its explantation. Because of the poor performance status of the patient, this may not always be an option. We report a successful treatment concept without removal of the infected graft. Methods: The infected ascending aortic graft and the remaining sternum of a critically ill 60-year-old man were covered with a bilateral pectoralis muscle flap. Results: Postoperatively, the laboratory test values normalized and the patient was discharged 1 month after the intervention. One year after surgery, the patient was in good condition and the examination showed no signs of infection. Conclusion: The thus demonstrated treatment concept with insertion of well-vascularized tissues in combination with a specific antibiotic regime in our hands proved to be an additional option for the successful management of life-threatening infections of a sternal osteomyelitis in combination of an infected aortic graft.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Der Aufsatz untersucht die Faktur vormoderner Literatur als Resultat einer ihr grundlegend eingeschriebenen, aber nurmehr implizit präsenten Struktur: der visuellen Vorstellung eines Autors davon, wie sein (linearer) Text auf der (zweidimensionalen) Fläche der Buchseite und im (dreidimensionalen) Raum des Buchs präsentiert und rezipiert werden wird. Mit der These, dass diese - bewusste oder unbewusste - Vorstellung direkten Einfluss auf die Gestaltung des zumeist fern von seinem gedachten Buch überlieferten Textes, mithin auf seine Struktur, hat, soll ein bisher unbeachteter Aspekt seiner Historizität geltend gemacht und als Faktor historischer Interpretation ins Gespräch gebracht werden. Als Stellvertreter des ,,gedachten Buchs", das als mentales Bild empirisch unerreichbar bleibt, werden prototypische Erscheinungsformen von Buchseiten und Büchern angeführt, die in Abhängigkeit von Faktoren wie Entstehungszeitpunkt und ‑kontext, Gattung und Sprache zwischen dem 12. und 16. Jahrhundert in der Regel präzise zu beschreiben sind. Für den Sonderfall narrativer Literatur, der der Aufsatz im engeren Sinne gilt, erweist sich die Analogie zweier Doppelstrukturen als interpretatorisches Schlüsselelement: die der sich im Handlungsverlauf sukzessive entfaltenden und doch abgeschlossenen erzählten Welt und die der linearen (seitenkontinuierlichen) und der dimensionalen (im diskontinuierlichen Zugriff realisierbaren) Ordnung des Mediums Buch. An drei Fallbeispielen in historischen Querschnitten wird demonstriert, wie das Wissen um diese zweifache Doppelstruktur und ihre Analogie die Faktur eines Erzähltextes unter unterschiedlichen medialen Rahmenbedingungen beeinflusst.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectif: Déterminer la prévalence de la dysfonction de la valve aortique, de la dilatation de l'aorte proximale et des interventions au niveau de la valve aortique et de l'aorte ascendante chez les adultes avec une coarctation de l'aorte. Contexte: La dysfonction de la valve aortique et la dilatation de l'aorte proximale sont rares chez les enfants et les adolescents avec une coarctation de l'aorte. A long terme, les adultes pourraient être plus à risque de développer ce type de pathologie. Méthode: Nous avons rétrospectivement passé en revue tous les adultes avec une coarctation de l'aorte corrigée ou pas suivis au « Boston Children's Hospital » entre 2004 et 2010. Résultats: 216 adultes (56 % d'hommes) avec une coarctation ont été identifiés. L'âge médian à la dernière évaluation était de 28 (de 18 à 75) ans. Une bicuspidie aortique était présente dans 66% des cas. Au dernier contrôle, 3% avaient une sténose aortique modérée ou sévère et 4% avaient une insuffisance aortique modérée à sévère. Une dilatation de la racine de l'aorte ou de l'aorte ascendante était présente dans 28%, respectivement 42% des patients. Une dilatation au moins modérée de la racine de l'aorte ou de l'aorte ascendante (score Z > 4) était présente dans 8%, respectivement 14%. Les patients avec une bicuspidie aortique étaient plus sujets à avoir une dilatation au moins modérée de la racine de l'aorte ou de l'aorte ascendante comparés à ceux sans bicuspidie (20% contre 0%; p<0.001). L'âge était associé à une dilatation de l'aorte ascendante (p=0.04). Au dernier suivi, 6% avait nécessité une intervention au niveau de la valve aortique et 3% un remplacement de la racine de l'aorte ou de l'aorte ascendante.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We created a high-throughput modality of photoactivated localization microscopy (PALM) that enables automated 3D PALM imaging of hundreds of synchronized bacteria during all stages of the cell cycle. We used high-throughput PALM to investigate the nanoscale organization of the bacterial cell division protein FtsZ in live Caulobacter crescentus. We observed that FtsZ predominantly localizes as a patchy midcell band, and only rarely as a continuous ring, supporting a model of "Z-ring" organization whereby FtsZ protofilaments are randomly distributed within the band and interact only weakly. We found evidence for a previously unidentified period of rapid ring contraction in the final stages of the cell cycle. We also found that DNA damage resulted in production of high-density continuous Z-rings, which may obstruct cytokinesis. Our results provide a detailed quantitative picture of in vivo Z-ring organization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Off-pump trans left ventricular approach provides more precise deployment of stented aortic valve of any size with respect to the endovascular replacement. One of the key steps of this procedure is the ventricle repair after catheter withdrawing. We designed an animal study to compare the consistency of a sutureless repair of the left ventricle access using nitinol occluder with and without pericardial cuff on the ventricular side. METHODS: Material description: The Amplatz-nitinol occluder consists of two square heads squeezing ventricle wall in between them, sealing the defect. To improve its sealing property, a pericardial patch was sutured to the ventricular head of the occluder. Animal study setup: In adult pigs, a 30F sheath was inserted into the epigastric area through the cardiac apex, up to the left ventricle, simulating the approach for off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with standard occluder in half of the animals, and cuffed occluder in the other half. Animals were followed-up for 3h, collecting haemodynamics data and pericardial bleeding. RESULTS: Device was successfully deployed in 12 animals in less than 1min. In the group where the standard occluder was used, bleeding during the deployment was 80+/-20ml and after the deployment was 800+/-20ml over 3h. In the group where the cuffed occluder was used, bleeding during the deployment was 85+/-20ml and after the deployment was 100+/-5ml over 3h. In the cuffed group, bleeding was significantly lower than the standard group, p-value being <0.001. CONCLUSIONS: The occluder is easy to use and the pericardial cuff dramatically increases its efficacy as demonstrated by a significant reduction of blood loss. The cuffed occluder opens the way for endoscopic, off-pump, transventricular aortic valve replacement.