177 resultados para Ankle-foot orthosis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Chronic lateral ankle instability accounts for 20% of the ankle injuries. This study evaluates functional outcome of the modified Broström-Gould technique using suture anchors, with 4 different clinical scores. METHODS: A consecutive series of 41 patients were included with a minimum follow-up of one year. The function was assessed using 4 clinical scores including: the AOFAS for hind foot; the FAAM; the CAIT and the CAIS. RESULTS: Out of 41 patients; 27 patients were very satisfied, 11 satisfied and 3 were not satisfied. Ankle mobility returned to normal in 93% of patients. At follow-up the AOFAS was 89/100 (37-100), the FAAM 85/100% (35-100%), the CAIT 20/30 (5-30), and the CAIS 74/100% (27-100%). CONCLUSION: Outcome of modified Broström-Gould procedure is good with high satisfaction rate in terms of ankle mobility. The disparity in outcome of scores, signals towards the need of a standard evaluation system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction.- Since the work of the "International Association for the Study of Pain" (IASP), complex regional pain syndrome type 1 (CRPS I) or algodystrophy includes motor disorders (tremor, dystony, myoclony) as diagnosis criterion. This can lead to confusion with some neurologic disorders which can wrongly be considered as CRPS I. The following observation illustrates this problem.Observation.- A 31-year-old man was hospitalised in a rehabilitation clinic in April 2007 with suspected CRPS I with persistent pain in the left leg. In 2005, the patient underwent ligament reconstruction at the right ankle. In May 2006, a recurrence of his ankle sprain was treated conservatively. The course of this pathology was unfavourable with an extension of the pain areas (leg and foot) as well as an appearance of abnormal motion. Toe motion in abduction was observed (especially T5) followed by a flexion cramp; an hypoesthesia in the sural nerve area, a scar allodynia and discrete vasomotor disorders. The scintigraphy was compatible with a stage 2 algodystrophy. Lower limb electromyography was normal; measurement of pseudo periodic activity of the motor unit at the foot level (abductor of the 5th toe, 4th interosseous). A "Painful legs and moving toes syndrome" was diagnosed which was treated with gabapentin and carbamazepine with a partial improvement.Discussion.- The "Painful legs and moving toes syndrome" is a rare pathology rehabilitation specialists should recognize. The origin is often peripheral nerve damage. The medullar interneuron activation (between the dorsal and ventral horn) is considered as the source of the efferent motor nerves which are responsible for the abnormal movements. This observation illustrates the need for a demanding approach before establishing the diagnosis of CRPS I and the respect of the 4th criterion of the ASP (exclusion of this syndrome when another pathology may explain pain and dysfunction).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Time periods composing stance phase of gait can be clinically meaningful parameters to reveal differences between normal and pathological gait. This study aimed, first, to describe a novel method for detecting stance and inner-stance temporal events based on foot-worn inertial sensors; second, to extract and validate relevant metrics from those events; and third, to investigate their suitability as clinical outcome for gait evaluations. 42 subjects including healthy subjects and patients before and after surgical treatments for ankle osteoarthritis performed 50-m walking trials while wearing foot-worn inertial sensors and pressure insoles as a reference system. Several hypotheses were evaluated to detect heel-strike, toe-strike, heel-off, and toe-off based on kinematic features. Detected events were compared with the reference system on 3193 gait cycles and showed good accuracy and precision. Absolute and relative stance periods, namely loading response, foot-flat, and push-off were then estimated, validated, and compared statistically between populations. Besides significant differences observed in stance duration, the analysis revealed differing tendencies with notably a shorter foot-flat in healthy subjects. The result indicated which features in inertial sensors' signals should be preferred for detecting precisely and accurately temporal events against a reference standard. The system is suitable for clinical evaluations and provides temporal analysis of gait beyond the common swing/stance decomposition, through a quantitative estimation of inner-stance phases such as foot-flat.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aims to design a wearable system for kinetics measurement of multi-segment foot joints in long-distance walking and to investigate its suitability for clinical evaluations. The wearable system consisted of inertial sensors (3D gyroscopes and 3D accelerometers) on toes, forefoot, hindfoot, and shank, and a plantar pressure insole. After calibration in a laboratory, 10 healthy elderly subjects and 12 patients with ankle osteoarthritis walked 50m twice wearing this system. Using inverse dynamics, 3D forces, moments, and power were calculated in the joint sections among toes, forefoot, hindfoot, and shank. Compared to those we previously estimated for a one-segment foot model, the sagittal and transverse moments and power in the ankle joint, as measured via multi-segment foot model, showed a normalized RMS difference of less than 11%, 14%, and 13%, respectively, for healthy subjects, and 13%, 15%, and 14%, for patients. Similar to our previous study, the coronal moments were not analyzed. Maxima-minima values of anterior-posterior and vertical force, sagittal moment, and power in shank-hindfoot and hindfoot-forefoot joints were significantly different between patients and healthy subjects. Except for power, the inter-subject repeatability of these parameters was CMC>0.90 for healthy subjects and CMC>0.70 for patients. Repeatability of these parameters was lower for the forefoot-toes joint. The proposed measurement system estimated multi-segment foot joints kinetics with acceptable repeatability but showed difference, compared to those previously estimated for the one-segment foot model. These parameters also could distinguish patients from healthy subjects. Thus, this system is suggested for outcome evaluations of foot treatments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rheumatoid arthritis is an autoimmune disease that may affect multiple joints, both small and large, and leads to numerous complications. The standard surgical treatment for a rheumatoid arthritic ankle has been an arthrodesis. The ideal candidate for an ankle replacement in a rheumatoid patient is one who is moderately active, has a well-aligned ankle and heel, and a fair range of motion in the ankle joint. Good surgical technique and correction of any hindfoot deformity will result in satisfactory alignment of the ankle with regard to the mechanical axis, and this will lead to increased prosthetic longevity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Outcome following foot and ankle surgery can be assessed by disease- and region-specific scores. Many scoring systems exist, making comparison among studies difficult. The present study focused on outcome measures for a common foot and ankle abnormality and compared the results obtained by 2 disease-specific and 2 body region-specific scores. METHODS: We reviewed 41 patients who underwent lateral ankle ligament reconstruction. Four outcome scales were administered simultaneously: the Cumberland Ankle Instability Tool (CAIT) and the Chronic Ankle Instability Scale (CAIS), which are disease specific, and the American Orthopedic Foot & Ankle Society (AOFAS) hindfoot scale and the Foot and Ankle Ability Measure (FAAM), which are both body region-specific. The degree of correlation between scores was assessed by Pearson's correlation coefficient. Nonparametric tests, the Kruskal-Wallis and the Mann-Whitney test for pairwise comparison of the scores, were performed. RESULTS: A significant difference (P < .005) was observed between the CAIS and the AOFAS score (P = .0002), between the CAIS and the FAAM 1 (P = .0001), and between the CAIT and the AOFAS score (P = .0003). CONCLUSIONS: This study compared the performances of 4 disease- and body region-specific scoring systems. We demonstrated a correlation between the 4 administered scoring systems and notable differences between the results given by each of them. Disease-specific scores appeared more accurate than body region-specific scores. A strong correlation between the AOFAS score and the other scales was observed. The FAAM seemed a good compromise because it offered the possibility to evaluate the patient according to his or her own functional demand. CLINICAL RELEVANCE: The present study contributes to the development of more critical and accurate outcome assesment methods in foot and ankle surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background : This study aimed to use plantar pressure analysis in relatively long-distance walking for objective outcome evaluation of ankle osteoarthritis treatments, i.e., ankle arthrodesis and total ankle replacement.Methods : Forty-seven subjects in four groups: three patient groups and controls, participated in the study. Each subject walked twice in 50-m trials. Plantar pressure under the pathological foot was measured using pressure insoles. Six parameters: initial contact time, terminal contact time, maximum force time, peak pressure time, maximum force and peak pressure were calculated and averaged over trials in ten regions of foot. The parameters in each region were compared between patient groups and controls and their effect size was estimated. Besides, the correlations between pressure parameters and clinical scales were calculated.Findings : We observed based on temporal parameters that patients postpone the heel-off event, when high force in forefoot and high ankle moment happens. Also based on maximum force and peak pressure, the patients apply smoothened maximum forces on the affected foot. In ten regions, some parameters showed improvements after total ankle replacement, some showed alteration of foot function after ankle arthrodesis and some others showed still abnormality after both surgical treatments. These parameters showed also significant correlation with clinical scales in at least two regions of foot.Interpretation : Plantar pressure parameters in relatively long-distance trials showed to be strong tools for outcome evaluation of ankle osteoarthritis treatments. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Usually the measurement of multi-segment foot and ankle complex kinematics is done with stationary motion capture devices which are limited to use in a gait laboratory. This study aimed to propose and validate a wearable system to measure the foot and ankle complex joint angles during gait in daily conditions, and then to investigate its suitability for clinical evaluations. The foot and ankle complex consisted of four segments (shank, hindfoot, forefoot, and toes), with an inertial measurement unit (3D gyroscopes and 3D accelerometers) attached to each segment. The angles between the four segments were calculated in the sagittal, coronal, and transverse planes using a new algorithm combining strap-down integration and detection of low-acceleration instants. To validate the joint angles measured by the wearable system, three subjects walked on a treadmill for five minutes at three different speeds. A camera-based stationary system that used a cluster of markers on each segment was used as a reference. To test the suitability of the system for clinical evaluation, the joint angle ranges were compared between a group of 10 healthy subjects and a group of 12 patients with ankle osteoarthritis, during two 50-m walking trials where the wearable system was attached to each subject. On average, over all joints and walking speeds, the RMS differences and correlation coefficients between the angular curves obtained using the wearable system and the stationary system were 1 deg and 0.93, respectively. Moreover, this system was able to detect significant alteration of foot and ankle function between the group of patients with ankle osteoarthritis and the group of healthy subjects. In conclusion, this wearable system was accurate and suitable for clinical evaluation when used to measure the multi-segment foot and ankle complex kinematics during long-distance walks in daily life conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Isolated avulsion fracture at the plantar lateral base of the first metatarsal (M1) is very rare. Case report: A 35 year old overweight woman sustained an eversion strain of her right foot. Despite pain along M1 she was able to continue walking for three days before presenting to her family doctor. Swelling on the plantar aspect of the foot was noticed, there was also pain at eversion of the foot and extension of the ankle. Plain X-ray showed no abnormalities. A MRI showed minimal bone bruise at the basis of M1 and a partial rupture of the peroneus longus tendon at its insertion. The patient was allowed to walk with partial weight bearing with a soft ankle brace. After 6 months she presented at our hospital because of persistent pain. There was still a painful insertion of the peroneus longus but active plantarflexion of M1 was possible. Plain X-rays were poorly contributive except for a discrete flattening of the longitunal arch. CT-scan showed a non displaced fracture at the M1-basis. A protocol with partial weight-bearing in a short-leg cast and partial weight-bearing orthosis each for 6 weeks was unsuccessfully attempted. Therefore, an excision of the non healed bone fragment at the basis of M1 and a first tarsometatarsal joint arthrodesis were performed. Postoperatively the patient wore a partial weight-bearing short leg cast for 6 weeks followed by a weight-bearing short leg cast for 6 weeks with favourable outcome. Discussion: Initial internal fixation has been reported to lead to good results [1, 2]. In our case the conservative treatment failed and leaded to non union. At that time we considered as too risky (overweight) to excise the fragment and reattach the peroneus longus tendon. Therefore, we excised the fragment and fused the first tarsometatarsal joint. This procedure allowed, at least partially, to compensate for the function of the peroneus longus tendon. 1 Murakami T, et al. Avulsion fracture of the peroneus longus at the first metatarsal insertion: a case report. Br J Sports Med. 2004. 2 Kwak HY, and Bae SW. Isolated avulsion fracture at the plantar lateral base of the first metatarsal: a case report. Foot Ankle Int 2000.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study is to introduce and describe a newly developed index using foot pressure analysis to quantify the degree of equinus gait in children with cerebral palsy before and after injection with botulinum toxin. Data were captured preinjection and 12 weeks postinjection. Ten children aged 2(1/2) to 6(1/2) years took part (5 boys and 5 girls). Three of them had a diagnosis of spastic diplegia and 7 of congenital hemiplegia. In total, 13 limbs were analyzed. After orientation and segmentation of raw pedobarographic data, we determined a dynamic foot pressure index graded 0 to 100 that quantified the relative degree of heel and forefoot contact during stance. These data were correlated (Pearson correlation) with clinical measurements of dorsiflexion at the ankle (on a slow and fast stretch) and video observation (using the Observational Gait Scale). Pedobarograph data were strongly correlated with both the Observational Gait Scale scores (R = 0.79, P < 0.005) and clinical measurements of dorsiflexion on a fast stretch, which is reflective of spasticity (R = 0.70, P < 0.005). We demonstrated the index's sensitivity in detecting changes in spasticity and good correlation with video observations seems to indicate this technique's potential validity. When manipulated and segmented appropriately, and with the development of a simple ordinal index, we found that foot pressure data provided a useful tool in tracking changes in patients with spastic equinus.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Ankle arthrodesis (AD) and total ankle replacement (TAR) are typical treatments for ankle osteoarthritis (AO). Despite clinical interest, there is a lack of their outcome evaluation using objective criteria. Gait analysis and plantar pressure assessment are appropriate to detect pathologies in orthopaedics but they are mostly used in lab with few gait cycles. In this study, we propose an ambulatory device based on inertial and plantar pressure sensors to compare the gait during long-distance trials between healthy subjects (H) and patients with AO or treated by AD and TAR. Methods: Our study included four groups: 11 patients with AO, 9 treated by TAR, 7 treated by AD and 6 control subjects. An ambulatory system (Physilog®, CH) was used for gait analysis; plantar pressure measurements were done using a portable insole (Pedar®-X, DE). The subjects were asked to walk 50 meters in two trials. Mean value and coefficient of variation of spatio-temporal gait parameters were calculated for each trial. Pressure distribution was analyzed in ten subregions of foot. All parameters were compared among the four groups using multi-level model-based statistical analysis. Results: Significant difference (p <0.05) with control was noticed for AO patients in maximum force in medial hindfoot and forefoot and in central forefoot. These differences were no longer significant in TAR and AD groups. Cadence and speed of all pathologic groups showed significant difference with control. Both treatments showed a significant improvement in double support and stance. TAR decreased variability in speed, stride length and knee ROM. Conclusions: In spite of a small sample size, this study showed that ankle function after AO treatments can be evaluated objectively based on plantar pressure and spatio-temporal gait parameters measured during unconstrained walking outside the lab. The combination of these two ambulatory techniques provides a promising way to evaluate foot function in clinics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this paper is to discuss the post-traumatic overload syndrome of the os trigonum as a possible cause of posterior ankle impingement and hindfoot pain. We have reviewed 19 athletes who were referred to our foot unit between 1995 and 2001 because of posterior ankle pain, and in whom a post-traumatic overload syndrome of os trigonum was diagnosed. All these patients were followed up over a period of 2 years. In 11 cases a chronic repetitive movements in forced plantar flexion was found. In the other eight cases the pain appeared to persist after a standard treatment of an ankle sprain in inversion plantar flexion. The diagnosis was based on clinical history, physical examination and X-rays that revealed a non-fused os trigonum. The confirmation of diagnosis was carried-out injecting local anaesthetic under fluoroscopic control. In all cases a corticosteroid injection as first line treatment was performed. In 6 cases a second injection was necessary to alleviate pain because incomplete recovery with the first injection. Three cases (16%) were recalcitrant to this treatment and in these three cases a surgical excision of the os trigonum was carried out. Our conclusion is that after some chronic athletic activity or an acute ankle sprain the os trigonum, if present, may undergo mechanical overload, remain undisrupted and become painful. Treatment by corticosteroid injection often resolves the problem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Ankle sprains affect 200'000 persons/year in Switzerland. Most incidences are successfully treated by conservative measures but 20% require reconstruction for symptomatic chronic lateral ankle instability. This study evaluates the functional outcome after a modified Broström-Gould technique as measured by different clinical scores and compares the functional outcome of this technique with other surgical treatments of ankle instability. Methods: This retrospective cohort study evaluates 47 patients who underwent a modified Broström-Gould procedure using suture anchors to refix the lateral ankle capsuloligamentary structures at our institution from 2005 to 2009 with a minimum follow-up of one year (13-72 Mo). All patients were operated by one single surgeon and evaluated by an independent examiner. The function was assessed using 4 scores including: the AOFAS (American Orthopaedic Foot and Ankle Society's Score) hindfoot score; the FAAM (Foot and Ankle Ability Measurement); the CAIT (Cumberland Ankle Instability Tool); the CAIS (Chronic Ankle Instability Scale). Results: Six patients were excluded leaving 41 patients for examination. 34 patients (83%) thought that their ankle was more stable after the surgery, 7 (17%) did not feel any difference. 27 patients were very satisfied, 11 satisfied and 3 not satisfied. Reasons for non satisfaction included persistent instability and pain. Ankle mobility returned to normal in 93% of patients. Five patients had transcient hypoesthesy in the area of the superficial peroneal nerve. One patient suffered from a superficial infection treated successfully by local measures. 80% had the perception of a normal ankle, 20% thought to be below normal. At follow-up the AOFAS was 89/100 (37-100), the FAAM 85/100% (35-100%), the CAIT 20/30 (5-30), and the CAIS 74/100% (27-100%). Conclusions: The modified Broström-Gould procedure, which belongs to the anatomic ankle stabilizations is relatively simple and offers good outcome that satisfied 93% of the patients in the present study. No active stabilisator is sacrificed. Preservation of the ankle mobility is better and the complication rate is lower than after non-anatomical procedures described in the literature. The CAIT appeared as the most severe score compared to the other scales used in our study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous studies assessed the outcome of ankle arthrodesis (AA) and total ankle replacement (TAR) surgeries; however, the extent of postoperative recovery towards bilateral gait mechanics (BGM) is unknown. We evaluated the outcome of the two surgeries at least 2 years post rehabilitation, focusing on BGM. 36 participants, including 12 AA patients, 12 TAR patients, and 12 controls were included. Gait assessment over 50 m distance was performed utilizing pressure insoles and 3D inertial sensors, following which an intraindividual comparison was performed. Most spatiotemporal and kinematic parameters in the TAR group were indicative of good gait symmetry, while the AA group presented significant differences. Plantar pressure symmetry among the AA group was also significantly distorted. Abnormality in biomechanical behavior of the AA unoperated, contralateral foot was observed. In summary, our results indicate an altered BGM in AA patients, whereas a relatively fully recovered BGM is observed in TAR patients, despite the quantitative differences in several parameters when compared to a healthy population. Our study supports a biomechanical assessment and rehabilitation of both operated and unoperated sides after major surgeries for ankle osteoarthrosis.