119 resultados para Animal anesthesia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We compared cerebral blood flow velocity during anesthesia with sevoflurane and halothane in 23 children admitted for elective surgery (age, 0.4-9.7 yr; median age, 1.9 yr; ASA physical status I-II). Inhaled induction was performed in a randomized sequence with sevoflurane or halothane. Under steady-state conditions, cerebral blood flow velocity (systolic [V(s)], mean [V(mn)], and diastolic [VD]) were measured by a blinded investigator using transcranial pulsed Doppler ultrasonography. The anesthetic was then changed. CBFV measurements were repeated after washout of the first anesthetic and after steady-state of the second (equivalent minimal alveolar concentration to first anesthetic). The resistance index was calculated. VD and V(mn) were significantly lower during sevoflurane (V(mn) 1.35 m/s) than during halothane (V(mn) 1.50 m/s; P = 0.001), whereas V(s) was unchanged. The resistance index was lower during halothane (P < 0.001). Our results indicate lower vessel resistance and higher mean velocity during halothane than during sevoflurane. IMPLICATIONS: The mean cerebral blood flow velocity is significantly decreased in children during inhaled anesthesia with sevoflurane than during halothane. This might be relevant for the choice of anesthetic in children with risk of increased intracranial pressure, neurosurgery, or craniofacial osteotomies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

WHAT'S KNOWN ON THE SUBJECT? AND WHAT DOES THE STUDY ADD?: The AMS 800 urinary control system is the gold standard for the treatment of urinary incontinence due to sphincter insufficiency. Despite excellent functional outcome and latest technological improvements, the revision rate remains significant. To overcome the shortcomings of the current device, we developed a modern electromechanical artificial urinary sphincter. The results demonstrated that this new sphincter is effective and well tolerated up to 3 months. This preliminary study represents a first step in the clinical application of novel technologies and an alternative compression mechanism to the urethra. OBJECTIVES: To evaluate the effectiveness in continence achievement of a new electromechanical artificial urinary sphincter (emAUS) in an animal model. To assess urethral response and animal general response to short-term and mid-term activation of the emAUS. MATERIALS AND METHODS: The principle of the emAUS is electromechanical induction of alternating compression of successive segments of the urethra by a series of cuffs activated by artificial muscles. Between February 2009 and May 2010 the emAUS was implanted in 17 sheep divided into three groups. The first phase aimed to measure bladder leak point pressure during the activation of the device. The second and third phases aimed to assess tissue response to the presence of the device after 2-9 weeks and after 3 months respectively. Histopathological and immunohistochemistry evaluation of the urethra was performed. RESULTS: Bladder leak point pressure was measured at levels between 1091 ± 30.6 cmH2 O and 1244.1 ± 99 cmH2 O (mean ± standard deviation) depending on the number of cuffs used. At gross examination, the explanted urethra showed no sign of infection, atrophy or stricture. On microscopic examination no significant difference in structure was found between urethral structure surrounded by a cuff and control urethra. In the peripheral tissues, the implanted material elicited a chronic foreign body reaction. Apart from one case, specimens did not show significant presence of lymphocytes, polymorphonuclear leucocytes, necrosis or cell degeneration. Immunohistochemistry confirmed the absence of macrophages in the samples. CONCLUSIONS: This animal study shows that the emAUS can provide continence. This new electronic controlled sequential alternating compression mechanism can avoid damage to urethral vascularity, at least up to 3 months after implantation. After this positive proof of concept, long-term studies are needed before clinical application could be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In contrast to mammalian erythrocytes, which have lost their nucleus and mitochondria during maturation, the erythrocytes of almost all other vertebrate species are nucleated throughout their lifespan. Little research has been done however to test for the presence and functionality of mitochondria in these cells, especially for birds. Here, we investigated those two points in erythrocytes of one common avian model: the zebra finch (Taeniopygia guttata). RESULTS: Transmission electron microscopy showed the presence of mitochondria in erythrocytes of this small passerine bird, especially after removal of haemoglobin interferences. High-resolution respirometry revealed increased or decreased rates of oxygen consumption by erythrocytes in response to the addition of respiratory chain substrates or inhibitors, respectively. Fluorometric assays confirmed the production of mitochondrial superoxide by avian erythrocytes. Interestingly, measurements of plasmatic oxidative markers indicated lower oxidative stress in blood of the zebra finch compared to a size-matched mammalian model, the mouse. CONCLUSIONS: Altogether, those findings demonstrate that avian erythrocytes possess functional mitochondria in terms of respiratory activities and reactive oxygen species (ROS) production. Interestingly, since blood oxidative stress was lower for our avian model compared to a size-matched mammalian, our results also challenge the idea that mitochondrial ROS production could have been one actor leading to this loss during the course of evolution. Opportunities to assess mitochondrial functioning in avian erythrocytes open new perspectives in the use of birds as models for longitudinal studies of ageing via lifelong blood sampling of the same subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Half of the patients with end-stage heart failure suffer from persistent atrial fibrillation (AF). Atrial kick (AK) accounts for 10-15% of the ejection fraction. A device restoring AK should significantly improve cardiac output (CO) and possibly delay ventricular assist device (VAD) implantation. This study has been designed to assess the mechanical effects of a motorless pump on the right chambers of the heart in an animal model. METHODS: Atripump is a dome-shaped biometal actuator electrically driven by a pacemaker-like control unit. In eight sheep, the device was sutured onto the right atrium (RA). AF was simulated with rapid atrial pacing. RA ejection fraction (EF) was assessed with intracardiac ultrasound (ICUS) in baseline, AF and assisted-AF status. In two animals, the pump was left in place for 4 weeks and then explanted. Histology examination was carried out. The mean values for single measurement per animal with +/-SD were analysed. RESULTS: The contraction rate of the device was 60 per min. RA EF was 41% in baseline, 7% in AF and 21% in assisted-AF conditions. CO was 7+/-0.5 l min(-1) in baseline, 6.2+/-0.5 l min(-1) in AF and 6.7+/-0.5 l min(-1) in assisted-AF status (p<0.01). Histology of the atrium in the chronic group showed chronic tissue inflammation and no sign of tissue necrosis. CONCLUSIONS: The artificial muscle restores the AK and improves CO. In patients with end-stage cardiac failure and permanent AF, if implanted on both sides, it would improve CO and possibly delay or even avoid complex surgical treatment such as VAD implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The last twenty years has witnessed important changes in the field of obstetric analgesia and anesthesia. In 2007, we conducted a survey to obtain information regarding the clinical practice of obstetric anesthesia in our country. The main objective was to ascertain whether recent developments in obstetric anesthesia had been adequately implemented into current clinical practice. Methodology: A confidential questionnaire was sent to 391 identified wiss obstetric anesthetists. The questionnaire included 58 questions on 5 main topics: activity and organization of the obstetric unit, practice of labor analgesia, practice of anesthesia for caesarean section, prevention of aspiration syndrome, and pain treatment after cesarean section. Results: The response rate was 80% (311/391). 66% of the surveyed anesthetists worked in intermediate size obstetric units (500-1500 deliveries per year). An anesthetist was on site 24/24 hours in only 53% of the obstetric units. Epidural labor analgesia with low dose local anesthetics combined with opioids was used by 87% but only 30% used patient controlled epidural analgesia (PCEA). Spinal anesthesia was the first choice for elective and urgent cesarean section for 95% of the responders. Adequate prevention of aspiration syndrome was prescribed by 78%. After cesarean section, a multimodal analgesic regimen was prescribed by 74%. Conclusion: When comparing these results with those of the two previous Swiss surveys [1, 2], it clearly appears that Swiss obstetric anesthetists have progressively adapted their practice to current clinical recommendations. But this survey also revealed some insufficiencies: 1. Of the public health system: a. Insufficient number of obstetric anesthetists on site 24 hours/24. b. Lack of budget in some hospitals to purchase PCEA pumps. 2. Of individual medical practice: a. Frequent excessive dosage of hyperbaric bupivacaine during spinal anesthesia for cesarean section. b. Frequent use of cristalloid preload before spinal anesthesia for cesarean section. c. Frequent systematic use of opioids when inducing general anesthesia for cesarean section. d. Fentanyl as the first choice opioid during induction of general anesthesia for severe preeclampsia. In the future, wider and more systematic information campaigns by the mean of the Swiss Association of Obstetric Anesthesia (SAOA) should be able to correct these points.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(Résumé de l'ouvrage) Der Nutzen der Philosophie für das Leben wird oftmals in Frage gestellt. Kurt Weisshaupt hat verdeutlicht, dass Faszination für grosse theoretische Fragen und Praxisbezug Hand in Hand gehen können. "Gibt man zu, dass alles Reden von Ethik mit Wissenschaft nichts zu tun habe - weil Ethik selbst keine strenge Wissenschaft sei und die strengen Wissenschaften wertfrei verführen -, dann liefert man die Moral dem Belieben einzelner Subjekte aus. Man tut dann zwar so, als ob der Mensch in moralischer Hinsicht als autonomes (ein sich selber Gesetze gebendes) Wesen betrachtet werden müsse, bestreitet aber zugleich die Verbindlichkeit der so entstandenen Gesetze für andere."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A key feature differentiating cooperative animal societies Is the apportionment of reproduction among individuals. Only recently have studies started to focus on intraspecific variability in the distribution of reproduction within animal societies, and the available data suggest that this variability might be greater than previously suspected. How can one account for intra-and interspecific variability in partitioning of reproduction? This Is one of the most intriguing problems in the study of social behaviour, and understanding the factors underlying this variability is one of the keys to understanding the properties of complex animal societies.

Relevância:

20.00% 20.00%

Publicador: