60 resultados para Aneurysms
Resumo:
BACKGROUND: Pharmacotherapy may represent a potential means to limit the expansion rate of abdominal aortic aneurysms (AAAs). Studies evaluating the efficacy of different pharmacological agents to slow down human AAA-expansion rates have been performed, but they have never been systematically reviewed or summarized. METHODS AND FINDINGS: Two independent reviewers identified studies and selected randomized trials and prospective cohort studies comparing the growth rate of AAA in patients with pharmacotherapy vs. no pharmacotherapy. We extracted information on study interventions, baseline characteristics, methodological quality, and AAA growth rate differences (in mm/year). Fourteen prospective studies met eligibility criteria. Five cohort studies raised the possibility of benefit of beta-blockers [pooled growth rate difference: -0.62 mm/year, (95%CI, -1.00 to -0.24)], but this was not confirmed in three beta-blocker RCTs [pooled RCT growth rate difference: -0.05 mm/year (-0.16 to 0.05)]. Statins have been evaluated in two cohort studies that yield a pooled growth rate difference of -2.97 (-5.83 to -0.11). Doxycycline and roxithromycin have been evaluated in two RCTs that suggest possible benefit [pooled RCT growth rate difference: -1.32 mm/year (-2.89 to 0.25)]. Studies assessing NSAIDs, diuretics, calcium channel blockers and ACE inhibitors, meanwhile, did not find statistically significant differences. CONCLUSIONS: Beta-blockers do not appear to significantly reduce the growth rate of AAAs. Statins and other anti-inflammatory agents appear to hold promise for decreasing the expansion rate of AAA, but need further evaluation before definitive recommendations can be made.
Resumo:
OBJECTIVES: A straightforward original Chimney Graft (CG) protocol has been developed at our institution in selected cases of juxtarenal aortic aneurysm (JRAA). The aim of this study was to present our clinical experience of consecutive series with use of uncovered self-expanding stent (SES) as "Open Chimney" (OCh) in the endovascular repair (EVAR) of JRAA. METHODS: A standard endograft with suprarenal fixation struts is delivered with its proximal covered edge just below the highest RA in JRAA presenting the ostium of the two renal arteries at a different aortic level and the distance between the highest renal artery and the beginning of the aneurysm (improved landing zone) ≥10 mm. The low-lying renal artery is maintained patent by the OCh graft (standard SES) delivered from left brachial access (6 Fr). All clinical, anatomical, and operative data were prospectively collected and retrieved for the study analysis. RESULTS: From July 2010 to November 2012, OCh EVAR was offered to 22 consecutive patients considered unfit for JRAA open repair. All procedures were technically successful with aneurysm exclusion and patent OCh graft. One small perioperative type Ia endoleak spontaneously disappeared at the 3-month CT control. One patient died because of acute decompensated heart failure. One patient presented a left hemispheric stroke. The median follow-up of 18 months (range 7-35) showed aneurysm exclusion in all patients without type I and III endoleaks, SES stenosis, and/or renal impairment. CONCLUSIONS: OCh-EVAR is a straightforward technique that can be employed in selected cases of JRAA, avoiding the more complex and expensive fenestrated EVAR.
Resumo:
PURPOSE: Abdominal aortic aneurysms (AAAs) expand because of aortic wall destruction. Enrichment in Vascular Smooth Muscle Cells (VSMCs) stabilizes expanding AAAs in rats. Mesenchymal Stem Cells (MSCs) can differentiate into VSMCs. We have tested the hypothesis that bone marrow-derived MSCs (BM-MSCs) stabilizes AAAs in a rat model. MATERIAL AND METHODS: Rat Fischer 344 BM-MSCs were isolated by plastic adhesion and seeded endovascularly in experimental AAAs using xenograft obtained from guinea pig. Culture medium without cells was used as control group. The main criteria was the variation of the aortic diameter at one week and four weeks. We evaluated the impact of cells seeding on inflammatory response by immunohistochemistry combined with RT-PCR on MMP9 and TIMP1 at one week. We evaluated the healing process by immunohistochemistry at 4 weeks. RESULTS: The endovascular seeding of BM-MSCs decreased AAA diameter expansion more powerfully than VSMCs or culture medium infusion (6.5% ± 9.7, 25.5% ± 17.2 and 53.4% ± 14.4; p = .007, respectively). This result was sustained at 4 weeks. BM-MSCs decreased expression of MMP-9 and infiltration by macrophages (4.7 ± 2.3 vs. 14.6 ± 6.4 mm(2) respectively; p = .015), increased Tissue Inhibitor Metallo Proteinase-1 (TIMP-1), compared to culture medium infusion. BM-MSCs induced formation of a neo-aortic tissue rich in SM-alpha active positive cells (22.2 ± 2.7 vs. 115.6 ± 30.4 cells/surface units, p = .007) surrounded by a dense collagen and elastin network covered by luminal endothelial cells. CONCLUSIONS: We have shown in this rat model of AAA that BM-MSCs exert a specialized function in arterial regeneration that transcends that of mature mesenchymal cells. Our observation identifies a population of cells easy to isolate and to expand for therapeutic interventions based on catheter-driven cell therapy.
Resumo:
This paper describes a realistic simulator for the Computed Tomography (CT) scan process for motion analysis. In fact, we are currently developing a new framework to find small motion from the CT scan. In order to prove the fidelity of this framework, or potentially any other algorithm, we present in this paper a simulator to simulate the whole CT acquisition process with a priori known parameters. In other words, it is a digital phantom for the motion analysis that can be used to compare the results of any related algorithm with the ground-truth realistic analytical model. Such a simulator can be used by the community to test different algorithms in the biomedical imaging domain. The most important features of this simulator are its different considerations to simulate the best the real acquisition process and its generality.
Resumo:
Tuberous sclerosis complex (TSC) is a rare genetic disorder characterised by multiple hamartomas, caused by inactivating mutations of the TSC1/TSC2 tumour suppressor genes. Classical pulmonary involvement in tuberous sclerosis complex (TSC) consists of lymphangioleiomyomatosis and/or multiple micronodular pneumocyte hyperplasia (MMPH). Association of TSC with pulmonary artery aneurysm (PAA) has been only exceptionally described. We report here the first case of TSC with multiple PAA in combination with MMPH, cardiac rhabdomyomas and bone, skin and brain involvement.
Resumo:
PURPOSE: Acute limb ischemia after thrombosis of a popliteal aneurysm is a distinct and limb-threatening entity. Preoperative intra-arterial thrombolysis may improve the outcome in this challenging situation. This study retrospectively analyzed a consecutive series of patients treated with preoperative thrombolysis and subsequent revascularization. METHODS: Thirteen patients with acute limb ischemia caused by thrombosis of a popliteal aneurysm underwent catheter-directed intra-arterial thrombolysis with urokinase and subsequent vascular reconstruction. The angiographic and clinical outcome was analyzed and compared with that in the literature. RESULTS: Complete aneurysm thrombosis with absence of runoff was documented in 12 cases. Thrombolysis restored perfusion with patency of the popliteal artery and a one- or two-vessel runoff in 77% of cases (10/13). Early cumulative graft patency and limb salvage rates were 68% and 83%, respectively, with an ankle/brachial index of 0.8 +/- 0.2. Lytic failure followed by attempts at bypass grafting was present in three patients (23%) and resulted in above-knee amputation. Severe rhabdomyolysis and fatal pulmonary embolism were responsible for a 15% early mortality rate. CONCLUSION: Preoperative thrombolysis followed by bypass grafting is a valid treatment option for patients who can withstand an additional period of ischemia that does not require immediate revascularization and intraoperative lysis. Lytic failure identifies patients with a highly compromised runoff who are probably best treated by means of subsequent amputation, without any attempts at bypass grafting.
Resumo:
PURPOSE: To explore the use of telementoring for distant teaching and training in endovascular aortic aneurysm repair (EVAR). METHODS: According to a prospectively designed study protocol, 48 patients underwent EVAR: the first 12 patients (group A) were treated at a secondary care center by an experienced interventionist, who was training the local team; a further 12 patients (group B) were operated by the local team at their secondary center with telementoring by the experienced operator from an adjacent suite; and the last 24 patients (group C) were operated by the local team with remote telementoring support from the experienced interventionist at a tertiary care center. Telementoring was performed using 3 video sources; images were transmitted using 4 ISDN lines. EVAR was performed using intravascular ultrasound and simultaneous fluoroscopy to obtain road mapping of the abdominal aorta and its branches, as well as for identifying the origins of the renal arteries, assessing the aortic neck, and monitoring the attachment of the stent-graft proximally and distally. RESULTS: Average duration of telementoring was 2.1 hours during the first 12 patients (group B) and 1.2 hours for the remaining 24 patients (group C). There was no difference in procedural duration (127+/-59 minutes in group A, 120+/-4 minutes in group B, and 119+/-39 minutes in group C; p=0.94) or the mean time spent in the ICU (26+/-15 hours in group A, 22+/-2 hours in group B, and 22+/-11 hours for group C; p=0.95). The length of hospital stay (11+/-4 days in group A, 9+/-4 days in group B, and 7+/-1 days in group C; p=0.002) was significantly different only for group C versus A (p=0.002). Only 1 (8.3%) patient (in group A: EVAR performed by the experienced operator) required conversion to open surgery because of iliac artery rupture. This was the only conversion (and the only death) in the entire study group (1/12 in group A versus 0/36 in groups B + C, p=0.31). CONCLUSIONS: Telementoring for EVAR is feasible and shows promising results. It may serve as a model for development of similar projects for teaching other invasive procedures in cardiovascular medicine.
Resumo:
BACKGROUND AND PURPOSE: Unruptured anterior inferior cerebellar artery (AICA) aneurysms are rare but potentially lethal cerebellopontine angle (CPA) lesions that may be misdiagnosed as vestibular schwannomas when they present with vestibulo-cochlear symptoms. METHODS: We report two cases of unruptured but symptomatic AICA aneurysms initially referred to us as atypical vestibular schwannomas requiring surgery. Two discriminant MR features are described. RESULTS: One patient refused treatment. The other was successfully treated by coil occlusion. CONCLUSIONS: Caution is advised before suspecting a CPA mass to be a purely extra-canalicular schwannoma, given its extreme rarity. Deafness and cerebellar ischemia may be prevented if AICA aneurysms are correctly identified preoperatively. In the absence of specific arterial imaging, two MR features may distinguish them from vestibular schwannomas: (1) the absence of internal auditory canal enlargement and (2) the "blurry dot sign," representing blood flow artefacts on pre- and postcontrast studies.
Resumo:
OBJECT: In 1999 we reported that 94% of unruptured middle cerebral artery (MCA) aneurysms managed prospectively between 1993 and 1997, according to a protocol favoring endovascular coiling, were best treated by surgical clipping. The goal of the current study was to delineate the most appropriate treatment option for unruptured MCA aneurysms today, considering the technical advances in imaging and in endovascular treatment. METHODS: 35 consecutive patients harboring 40 unruptured MCA aneurysms were treated between 1997 and December 2000. Patients with unruptured cerebral aneurysms are managed prospectively according to the same protocol as reported previously [1]: the primary treatment recommendation is endovascular packing with Guglielmi detachable coils (GDCs). Surgical clipping is recommended after failed attempt at coil placement or in the presence of angioanatomical features that contraindicate that type of endovascular therapy. RESULTS: One unruptured MCA aneurysm was treated by endovascular embolization, 37 unruptured MCA aneurysms were clipped, whereas 2 unruptured MCA aneurysms were trapped with simultaneous extracranial-intracranial revascularization. Postoperative angiography revealed complete exclusion of all aneurysms. Preservation of vascular permeability was demonstrated in all clip-reconstructed aneurysms, despite arterial branches frequently originating from the aneurysmal base. Cerebral revascularization of the distal MCA was successful in the 2 patients with giant aneurysms. None of the patients presented permanent disabling complications from the treatment of the unruptured MCA aneurysm. CONCLUSION: Despite major technical advances in imaging and in endovascular treatment of cerebral aneurysms, surgical clipping still is the most efficient treatment for unruptured MCA aneurysms at the beginning of the new millennium.
Resumo:
Intracranial aneurysms are a common pathologic condition with a potential severe complication: rupture. Effective treatment options exist, neurosurgical clipping and endovascular techniques, but guidelines for treatment are unclear and focus mainly on patient age, aneurysm size, and localization. New criteria to define the risk of rupture are needed to refine these guidelines. One potential candidate is aneurysm wall motion, known to be associated with rupture but difficult to detect and quantify. We review what is known about the association between aneurysm wall motion and rupture, which structural changes may explain wall motion patterns, and available imaging techniques able to analyze wall motion.
Resumo:
BACKGROUND: To evaluate the effect of statins on the annual expansion rate (ER) of small infrarenal abdominal aortic aneurysms (AAA). PATIENTS AND METHODS: All patients under regular surveillance for small AAA between January 2000 and September 2007, in the Department of Angiology, Lausanne University Hospital, were included. Inclusion criteria were baseline abdominal aortic diameter between 25 and 55 mm, at least two measurements of AAA diameter and a minimum follow up of 6 months. Patients with Marfan disease, infectious or inflammatory AAA, and patients with prior AAA repair were excluded. The influence of statin use and other factors on ER were examined by bivariate and multivariate analysis. RESULTS: Among 589 patients who underwent an abdominal aorta evaluation, 94 patients (89 % men, mean age 69.1 years) were finally included in the analysis. Baseline AAA size was 39.9 ± 7.7 mm (mean±SE) and 48.7 ± 8.4 mm at end of follow-up. Patients had a regular aneurysm size assessment during 38.5 ± 27.7 months. Mean ER was 3.59 mm/y (± 2.81). The 50 patients who were treated with statin during the study period had a lower ER compared to the 44 controls (2.91 vs 4.37 mm/year, p = 0.01). CONCLUSIONS: This study confirms the considerable individual variations in the AAA expansion rate, and emphasizes the need for regular aortic diameter assessments. In this study, patients treated with statin demonstrate a significant decrease in the ER compared to controls. This finding need to be evaluated in prospective interventional studies powered to demonstrate the potential benefit of statin treatment.
Resumo:
We report an unusual case of congenital giant coronary aneurysm. A 23 year-old male with a history of acute myocardial infarction presented an abnormal shadow in the left cardiac border on routine X-ray. Electrocardiogram and physical examination were normal without any clinical signs of inflammation, but computed tomography (CT) scan and cardiac magnetic resonance imaging (MRI) revealed a giant (>50mm) coronary aneurysm. Coronary artery bypass grafting (CABG) with coronary artery aneurysm (CAA) resection resolved the CAA. Coronary artery aneurysms are entities of localised dilation and can be common events in chronic infectious disease as a result of the systemic inflammatory state; however, giant coronary aneurysms (measuring more than 50mm) are rare. This is especially true where the pathological aetiology was not clearly defined or was believed to be of congenital origin. To date only a few published case reports exist for this type of pathological entity.
Resumo:
Coronary MR imaging is a promising noninvasive technique for the combined assessment of coronary artery anatomy and function. Anomalous coronary arteries and aneurysms can reliably be assessed in clinical practice using coronary MR imaging and the presence of significant left main or proximal multivessel coronary artery disease detected. Technical challenges that need to be addressed are further improvements in motion suppression and abbreviated scanning times aimed at improving spatial resolution and patient comfort. The development of new and specific contrast agents, high-field MR imaging with improved spatial resolution, and continued progress in MR imaging methods development will undoubtedly lead to further progress toward the noninvasive and comprehensive assessment of coronary atherosclerotic disease.
Resumo:
Cerebral aneurysms and arteriovenous malformations (AVMs) are well-known sources of intracranial hemorrhage, but can also manifest as other clinical symptoms or remain clinically asymptomatic. The aim was to document and analyze cases of aneurysm or AVM with brain infarction. Survey on 4804 stroke patients treated at the Department of Neurology, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland between 1978 and 2000 using the Lausanne Stroke Registry. Twenty patients presented with cerebral aneurysm and 21 with cerebral AVM. Hemorrhage was present in 100% of the AVM and in 75% of the aneurysm patients; in one (5%) of the remaining aneurysm patients, aneurysm and infarction were located in different territories. Infarction associated with Sylvian artery aneurysm was found in three (15%), vertebrobasilar ischemia because of fusiform left vertebral artery aneurysm in one (5%), and dural fistula draining to the distal transversal and left sigmoid sinus associated with a stroke in the territory of the left anterior inferior cerebellar artery in one patient. Ischemic stroke is infrequent, but important, complication in unruptured intracranial aneurysms and AVMs. The early recognition and therapy of these vascular malformations in selected patients can avoid a major neurological deficit or death caused by their rupture.
Resumo:
Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.