45 resultados para 3-dimensional Solution Structure
Resumo:
OBJECTIVES: Lesion detection and characterization in multiple sclerosis (MS) are an essential part of its clinical diagnosis and an important research field. In this pilot study, we applied the recently introduced two inversion-contrast magnetization-prepared rapid gradient echo sequence (MP2RAGE) to patients with early-stage MS.¦MATERIALS AND METHODS: The MP2RAGE is a 3-dimensional (3D) magnetization-prepared rapid gradient echo derivative providing homogeneous T1 weighting and simultaneous T1 mapping. The MP2RAGE performance was compared with that of 2 clinical routine sequences (2D fluid-attenuated inversion recovery [FLAIR] and 3D magnetization-prepared rapid gradient echo [MP-RAGE]) and 2 state-of-the art clinical research sequences (the 3D FLAIR-SPACE [sampling perfection with application-optimized contrasts by using different flip-angle evolutions], a fluid-attenuated variable flip-angle fast spin echo technique, and the 3D double-inversion recovery SPACE). A cohort of 10 early-stage female MS patients (age, 31.6 ± 4.7 years; disease duration, 3.8 ± 1.9 years; median expanded disability status scale score, 1.75) and 10 age- and gender-matched controls were enrolled after approval of the local institutional review board was obtained. Multiple sclerosis lesions were identified and assigned to brain locations and tissue types by two experienced physicians in all 5 contrasts. Subsequently, lesions were manually delineated for comparison and statistical analysis of lesion count, volume and quantitative measures.¦RESULTS AND CONCLUSIONS: The results show that the 3D T1-weighted high-resolution MP2RAGE contrast provides a sensitive means for MS lesion assessment. The additional quantitative T1 relaxation time maps obtained with the MP2RAGE provide further potential diagnostic and prognostic information that could help (a) to better discriminate lesion subtypes and (b) to stage and predict the activity and the evolution of MS. Results also indicate that the T2-weighted double-inversion recovery and FLAIR-SPACE contrasts are attractive complements to the MP2RAGE for lesion detection.
Resumo:
PURPOSE: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. METHODS AND MATERIALS: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. RESULTS: Cross-validation revealed a dice similarity of 95% ± 2% for the sclera and cornea and 91% ± 2% for the lens. Overall, mean segmentation error was found to be 0.3 ± 0.1 mm. Average segmentation time was 14 ± 2 s on a standard personal computer. CONCLUSIONS: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.
Resumo:
Proteins of the RsmA/CsrA family are global translational regulators in many bacterial species. We have determined the solution structure of a complex formed between the RsmE protein, a member of this family from Pseudomonas fluorescens, and a target RNA encompassing the ribosome-binding site of the hcnA gene. The RsmE homodimer with its two RNA-binding sites makes optimal contact with an 5'-A/UCANGGANGU/A-3' sequence in the mRNA. When tightly gripped by RsmE, the ANGGAN core folds into a loop, favoring the formation of a 3-base-pair stem by flanking nucleotides. We validated these findings by in vivo and in vitro mutational analyses. The structure of the complex explains well how, by sequestering the Shine-Dalgarno sequence, the RsmA/CsrA proteins repress translation.
Resumo:
TWEAK (TNF homologue with weak apoptosis-inducing activity) and Fn14 (fibroblast growth factor-inducible protein 14) are members of the tumor necrosis factor (TNF) ligand and receptor super-families. Having observed that Xenopus Fn14 cross-reacts with human TWEAK, despite its relatively low sequence homology to human Fn14, we examined the conservation in tertiary fold and binding interfaces between the two species. Our results, combining NMR solution structure determination, binding assays, extensive site-directed mutagenesis and molecular modeling, reveal that, in addition to the known and previously characterized β-hairpin motif, the helix-loop-helix motif makes an essential contribution to the receptor/ligand binding interface. We further discuss the insight provided by the structural analyses regarding how the cysteine-rich domains of the TNF receptor super-family may have evolved over time. DATABASE: Structural data are available in the Protein Data Bank/BioMagResBank databases under the accession codes 2KMZ, 2KN0 and 2KN1 and 17237, 17247 and 17252. STRUCTURED DIGITAL ABSTRACT: TWEAK binds to hFn14 by surface plasmon resonance (View interaction) xeFn14 binds to TWEAK by enzyme linked immunosorbent assay (View interaction) TWEAK binds to xeFn14 by surface plasmon resonance (View interaction) hFn14 binds to TWEAK by enzyme linked immunosorbent assay (View interaction).
Resumo:
We analyzed the expression of glial hyaluronate-binding protein (GHAP), an integral component of the extracellular matrix, in aggregating brain cell cultures of fetal rat telencephalon using immunofluorescence. GHAP immunoreactivity appeared after 1 week in culture, simultaneous with the first deposits of myelin basic protein, and showed a development-dependent increase. Comparison of glia-enriched and neuron-enriched cultures showed that only glial cells express GHAP. Three peptide growth factors, epidermal growth factor, fibroblast growth factor and platelet-derived growth factor, which are known to stimulate the differentiation of glial cells, modulated the deposit of GHAP immunoreactivity. The 3-dimensional structure of aggregate cultures promoted GHAP deposition, suggesting that cell-cell interactions are required for extracellular matrix formation. Furthermore GHAP production seemed to depend on the developmental stage of the glial cells.
Resumo:
The aim of the present study is to determine the level of correlation between the 3-dimensional (3D) characteristics of trabecular bone microarchitecture, as evaluated using microcomputed tomography (μCT) reconstruction, and trabecular bone score (TBS), as evaluated using 2D projection images directly derived from 3D μCT reconstruction (TBSμCT). Moreover, we have evaluated the effects of image degradation (resolution and noise) and X-ray energy of projection on these correlations. Thirty human cadaveric vertebrae were acquired on a microscanner at an isotropic resolution of 93μm. The 3D microarchitecture parameters were obtained using MicroView (GE Healthcare, Wauwatosa, MI). The 2D projections of these 3D models were generated using the Beer-Lambert law at different X-ray energies. Degradation of image resolution was simulated (from 93 to 1488μm). Relationships between 3D microarchitecture parameters and TBSμCT at different resolutions were evaluated using linear regression analysis. Significant correlations were observed between TBSμCT and 3D microarchitecture parameters, regardless of the resolution. Correlations were detected that were strongly to intermediately positive for connectivity density (0.711≤r(2)≤0.752) and trabecular number (0.584≤r(2)≤0.648) and negative for trabecular space (-0.407 ≤r(2)≤-0.491), up to a pixel size of 1023μm. In addition, TBSμCT values were strongly correlated between each other (0.77≤r(2)≤0.96). Study results show that the correlations between TBSμCT at 93μm and 3D microarchitecture parameters are weakly impacted by the degradation of image resolution and the presence of noise.
Resumo:
The aim of this study was to evaluate the combination of abdominoplasty with liposuction of both flanks with regards to length of scar, complications, and patient's satisfaction. A retrospective analysis of 35 patients who underwent esthetic abdominoplasty at our institution between 2002 and 2004 was performed. Thirteen patients underwent abdominoplasty with liposuction of both flanks, 22 patients underwent conventional abdominoplasty. Liposuction of the flanks did not increase the rate of complications of the abdominoplasty procedures. We found a tendency toward shorter scars in patients who underwent abdominoplasty combined with liposuction of the flanks. Implementation of 3-dimensional laser surface scanning to objectify the postoperative outcomes, documented a comparable degree of flatness of the achieved body contouring in both procedures. 3-dimensional laser surface scanning can be a valuable tool to objectify assessment of postoperative results.
Resumo:
Despite the long tradition for asking about the negative social and health consequences of alcohol consumption in surveys, little is known about the dimensionality of these consequences. Analysing cross-sectional and longitudinal data from the Nordic Taxation Study collected for Sweden, Finland, and Denmark in two waves in 2003 and 2004 by means of an explorative principal component analysis for categorical data (CATPCA), it is tested whether consequences have a single underlying dimension across cultures. It further tests the reliability, replicability, concurrent and predictive validity of the consequence scales. A one-dimensional solution was commonly preferable. Whereas the two-dimensional solution was unable to distinguish clearly between different concepts of consequences, the one-dimensional solution resulted in interpretable, generally very stable scales within countries across different samples and time.
Resumo:
INTRODUCTION: Gamma Knife surgery (GKS) is a non-invasive neurosurgical stereotactic procedure, increasingly used as an alternative to open functional procedures. This includes targeting of the ventro-intermediate nucleus of the thalamus (e.g. Vim) for tremor. We currently perform an indirect targeting, as the Vim is not visible on current 3Tesla MRI acquisitions. Our objective was to enhance anatomic imaging (aiming at refining the precision of anatomic target selection by direct visualisation) in patients treated for tremor with Vim GKS, by using high field 7T MRI. MATERIALS AND METHODSH: Five young healthy subjects were scanned on 3 (T1-w and diffusion tensor imaging) and 7T (high-resolution susceptibility weighted images (SWI)) MRI in Lausanne. All images were further integrated for the first time into the Gamma Plan Software(®) (Elekta Instruments, AB, Sweden) and co-registered (with T1 was a reference). A simulation of targeting of the Vim was done using various methods on the 3T images. Furthermore, a correlation with the position of the found target with the 7T SWI was performed. The atlas of Morel et al. (Zurich, CH) was used to confirm the findings on a detailed analysis inside/outside the Gamma Plan. RESULTS: The use of SWI provided us with a superior resolution and an improved image contrast within the basal ganglia. This allowed visualization and direct delineation of some subgroups of thalamic nuclei in vivo, including the Vim. The position of the target, as assessed on 3T, perfectly matched with the supposed one of the Vim on the SWI. Furthermore, a 3-dimensional model of the Vim-target area was created on the basis of the obtained images. CONCLUSION: This is the first report of the integration of SWI high field MRI into the LGP, aiming at the improvement of targeting validation of the Vim in tremor. The anatomical correlation between the direct visualization on 7T and the current targeting methods on 3T (e.g. quadrilatere of Guyot, histological atlases) seems to show a very good anatomical matching. Further studies are needed to validate this technique, both by improving the accuracy of the targeting of the Vim (potentially also other thalamic nuclei) and to perform clinical assessment.
Resumo:
The integration of geophysical data into the subsurface characterization problem has been shown in many cases to significantly improve hydrological knowledge by providing information at spatial scales and locations that is unattainable using conventional hydrological measurement techniques. The investigation of exactly how much benefit can be brought by geophysical data in terms of its effect on hydrological predictions, however, has received considerably less attention in the literature. Here, we examine the potential hydrological benefits brought by a recently introduced simulated annealing (SA) conditional stochastic simulation method designed for the assimilation of diverse hydrogeophysical data sets. We consider the specific case of integrating crosshole ground-penetrating radar (GPR) and borehole porosity log data to characterize the porosity distribution in saturated heterogeneous aquifers. In many cases, porosity is linked to hydraulic conductivity and thus to flow and transport behavior. To perform our evaluation, we first generate a number of synthetic porosity fields exhibiting varying degrees of spatial continuity and structural complexity. Next, we simulate the collection of crosshole GPR data between several boreholes in these fields, and the collection of porosity log data at the borehole locations. The inverted GPR data, together with the porosity logs, are then used to reconstruct the porosity field using the SA-based method, along with a number of other more elementary approaches. Assuming that the grid-cell-scale relationship between porosity and hydraulic conductivity is unique and known, the porosity realizations are then used in groundwater flow and contaminant transport simulations to assess the benefits and limitations of the different approaches.
Resumo:
In this article we present a method to achieve tri-dimensional contouring of macroscopic objects. A modified reference wave speckle interferometer is used in conjunction with a source of reduced coherence. The depth signal is given by the envelope of the interference signal, directly determined by the coherence length of the source. Fringes are detected in the interferogram obtained by a single shot and are detected by means of adequate filtering. With the approach based on off-axis configuration, a contour line can be extracted from a single acquisition, thus allowing to use the system in harsh environment. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
HYPOTHESIS: The nonanatomical design of reverse shoulder prostheses induce medial displacement of the center of rotation, impingements and may reduce the mobility of the shoulder. The aim of this study is to test the hypothesis that during activities of daily living functional mobility of the shoulder can be restored by scapular compensation. MATERIAL AND METHODS: A numerical 3-dimensional model was developed to reproduce the movement of the scapula and humerus, during 4 activities of daily living measured experimentally. This hypothesis was tested in 4 configurations of the aequalis reverse prosthesis (standard 36-mm glenosphere, 42-mm glenosphere, lateralized 36-mm glenosphere, lateralized Bony Increased-Offset Reverse Shoulder Arthroplasty [BIO-RSA]), which were implanted in the virtual model. All impingement positions were evaluated, as the required scapular compensation to avoid impingements. RESULTS: With the 36-mm glenosphere, impingements occurred only for rest of hand to back-pocket positions. The 42-mm partly improved the mobility. The 2 lateralized glenospheres were free of impingement. When impingements occurred, the scapular compensation was less than 10°. CONCLUSION: Most reverse prostheses impingements reported in clinical and biomechanical studies can be avoided, either by scapular compensation or by a glenosphere lateralization. After reverse shoulder arthroplasty, a fraction of the mobility of the gleno-humeral is transferred to the scapulo-thoracic joint.
Resumo:
Ideally, reconstruction of lower extremity soft tissue defects includes not only an esthetically pleasing 3-dimensional shape and solid anchoring to the underlying structures to resist shear forces, but should also address the restoration of sensation. Therefore, we present a prospective study on defect reconstruction of the lower leg and ankle to evaluate the role of sensate free fasciocutaneous lateral arm flap and the impact of sensory nerve reconstruction. Thirty patients were allocated randomly to the study group (n = 15) that obtained end-to-side sensate coaptation using the lower lateral cutaneous brachial nerve to the tibial nerve using the epineural window technique, or to the control group reconstructed without nerve coaptation. At 1-year follow-up the patients were evaluated for pain sensation, thermal sensibility, static and moving 2-point discrimination, and Semmes-Weinstein monofilament tests. Data from both groups were compared and statistically analyzed with the Mann-Whitney U test and the Fisher exact test. Flaps of the study group reached a static and moving 2-point discrimination and Semmes-Weinstein monofilament tests nearly equal to the contralateral leg area and significantly better than flaps of the control group. Donor damage morbidity of the tibial nerve did not occur. To our point of view resensation should be carried out by end-to-side neurorrhaphy to the tibial nerve because of the superior restoration of sensibility.
Resumo:
Aggregate cultures are primary cell cultures prepared from dissociated fetal cells. In rotation-mediated culture under rigorously controlled conditions, the isolated cells are able to reaggregate spontaneously, and to form a large number of practically identical spheres. The three-dimensional cell structure in each aggregate provides a maximum of cell-cell interactions, and thus enables the cells to rearrange and to develop in an organotypic fashion. Relatively simple techniques are now available which permit the preparation of aggregate cultures from fetal brain and liver cells. Since they can be grown in a chemically defined medium, and because they mimic several morphogenetic events occurring in vivo, these cultures offer a unique model for developmental studies. Moreover, they may be used as well for routine testing, for example for screening purposes in toxicology, and thus contribute to the reduction of animal experiments.
Resumo:
Background: Variable definitions of outcome (Constant score, Simple Shoulder Test [SST]) have been used to assess outcome after shoulder treatment, although none has been accepted as the universal standard. Physicians lack an objective method to reliably assess the activity of their patients in dynamic conditions. Our purpose was to clinically validate the shoulder kinematic scores given by a portable movement analysis device, using the activities of daily living described in the SST as a reference. The secondary objective was to determine whether this device could be used to document the effectiveness of shoulder treatments (for glenohumeral osteoarthritis and rotator cuff disease) and detect early failures.Methods: A clinical trial including 34 patients and a control group of 31 subjects over an observation period of 1 year was set up. Evaluations were made at baseline and 3, 6, and 12 months after surgery by 2 independent observers. Miniature sensors (3-dimensional gyroscopes and accelerometers) allowed kinematic scores to be computed. They were compared with the regular outcome scores: SST; Disabilities of the Arm, Shoulder and Hand; American Shoulder and Elbow Surgeons; and Constant.Results: Good to excellent correlations (0.61-0.80) were found between kinematics and clinical scores. Significant differences were found at each follow-up in comparison with the baseline status for all the kinematic scores (P < .015). The kinematic scores were able to point out abnormal patient outcomes at the first postoperative follow-up.Conclusion: Kinematic scores add information to the regular outcome tools. They offer an effective way to measure the functional performance of patients with shoulder pathology and have the potential to detect early treatment failures.Level of evidence: Level II, Development of Diagnostic Criteria, Diagnostic Study. (C) 2011 Journal of Shoulder and Elbow Surgery Board of Trustees.