387 resultados para CT ANGIOGRAPHY
Resumo:
RATIONALE AND OBJECTIVES: The purpose of this study was the investigation of the impact of real-time adaptive motion correction on image quality in navigator-gated, free-breathing, double-oblique three-dimensional (3D) submillimeter right coronary magnetic resonance angiography (MRA). MATERIALS AND METHODS: Free-breathing 3D right coronary MRA with real-time navigator technology was performed in 10 healthy adult subjects with an in-plane spatial resolution of 700 x 700 microm. Identical double-oblique coronary MR-angiograms were performed with navigator gating alone and combined navigator gating and real-time adaptive motion correction. Quantitative objective parameters of contrast-to-noise ratio (CNR) and vessel sharpness and subjective image quality scores were compared. RESULTS: Superior vessel sharpness, increased CNR, and superior image quality scores were found with combined navigator gating and real-time adaptive motion correction (vs. navigator gating alone; P < 0.01 for all comparisons). CONCLUSION: Real-time adaptive motion correction objectively and subjectively improves image quality in 3D navigator-gated free-breathing double-oblique submillimeter right coronary MRA.
Resumo:
Contexte¦Le PET/CT au 18Fluor (FDG) fait aujourd'hui partie intégrante des moyens diagnostiques¦à disposition pour la stadification des cancers suspectés ou connus. Il n'est pas rare de¦découvrir des lésions fortuites.¦Objectifs¦Notre but était de déterminer la fréquence des lésions tumorales ou non, cliniquement¦silencieuses (incidentalomes), chez des patients consécutifs non sélectionnés examinés¦par PET/CT au FDG pour un cancer connu ou supposé au sein du bassin populationnel¦du CHUV.¦Méthode¦Nous avons rétrospectivement lu les 1226 des rapports d'examens faits d'août 2009 à¦juillet 2010 pour toute indication oncologique et relevé les lésions de découverte¦fortuite et leur localisation, avant de rechercher leur investigation et leur prise en¦charge.¦Résultats¦Nous avons retenu 309 lésions fortuites chez 260 patients (25,2% des rapports lus),¦dont 141 chez 127 patients investiguées. Ont été relevés 31 patients présentant 32¦incidentalomes (2,6%), dont 6 étaient malins, 6 pré-malins et 20 bénins, soit un taux de¦1% pour les malins et pré-malins. Les sites les plus fréquents étaient les mêmes que¦dans la littérature, à savoir la thyroïde, le poumon, la sphère colorectale (lésions prémalignes¦uniquement) et les lymphomes. Pour ces trois derniers, les lésions étaient¦moins fréquentes que ce qui est rapporté. Tous ces foyers sont à investiguer¦soigneusement, afin de différencier une nouvelle atteinte d'une métastase.¦Conclusion¦En tant que première étude suisse sur le sujet, nous obtenons 1% d'incidentalomes¦(pré)malins, soit l'équivalent de la limite inférieure de la littérature, dans des sites¦similaires. Une amélioration serait possible en augmentant l'attention portée aux lésions¦jugées peu significatives. A l'instar de nombreuses autres études, nous sommes aussi¦confrontés au problème lié à l'interprétation des foyers de captation et à la nonspécificité¦du FDG.
Resumo:
This paper presents the segmentation of bilateral parotid glands in the Head and Neck (H&N) CT images using an active contour based atlas registration. We compare segmentation results from three atlas selection strategies: (i) selection of "single-most-similar" atlas for each image to be segmented, (ii) fusion of segmentation results from multiple atlases using STAPLE, and (iii) fusion of segmentation results using majority voting. Among these three approaches, fusion using majority voting provided the best results. Finally, we present a detailed evaluation on a dataset of eight images (provided as a part of H&N auto segmentation challenge conducted in conjunction with MICCAI-2010 conference) using majority voting strategy.
Resumo:
PURPOSE: This study analyzes CT examinations in Switzerland. MATERIALS AND METHODS: Using different sources (administrative data on the equipment, a 1998 nationwide inquiry into practices, and data provided by the Swiss University Hospitals of Basel, Zurich, and Lausanne), we determined the frequency of CT examinations (hospitals and private radiologists) in 1998 according to different descriptive variables and studied the progression in CT use over time. RESULTS: CT scanners increased by 7% between 1998 and 2004. The average annual number of CT examinations in 1998 was 46.3/1000 population, 3.4% of all radiological examinations in Switzerland in 1997-1998. The most frequent examination was CT of the skull (24%), while private radiology institutes perform more CTs of the spine. More CT examinations were performed for men than for women (sex ratio M/F=1.17). The average annual increase in CT in Swiss hospitals varied from 8% for Basel to 18% for Lausanne. Finally, the proportion of pediatric examinations was 5%; their numbers appear to be stabilizing. CONCLUSION: There is a significant increase in CT examinations. It is hoped that our study will heighten awareness among doctors of CT examinations in order to optimize their use.
Resumo:
The aims of this study were to determine whether responses in myocardial blood flow (MBF) to the cold pressor testing (CPT) method noninvasively with PET correlate with an established and validated index of flow-dependent coronary vasomotion on quantitative angiography. METHODS: Fifty-six patients (57 +/- 6 y; 16 with hypertension, 10 with hypercholesterolemia, 8 smokers, and 22 without coronary risk factors) with normal coronary angiograms were studied. Biplanar end-diastolic images of a selected proximal segment of the left anterior descending artery (LAD) (n = 27) or left circumflex artery (LCx) (n = 29) were evaluated with quantitative coronary angiography in order to determine the CPT-induced changes of epicardial luminal area (LA, mm(2)). Within 20 d of coronary angiography, MBF in the LAD, LCx, and right coronary artery territory was measured with (13)N-ammonia and PET at baseline and during CPT. RESULTS: CPT induced on both study days comparable percent changes in the rate x pressure product (%DeltaRPP, 37% +/- 13% and 40% +/- 17%; P = not significant [NS]). For the entire study group, the epicardial LA decreased from 5.07 +/- 1.02 to 4.88 +/- 1.04 mm(2) (DeltaLA, -0.20 +/- 0.89 mm(2)) or by -2.19% +/- 17%, while MBF in the corresponding epicardial vessel segment increased from 0.76 +/- 0.16 to 1.03 +/- 0.33 mL x min(-1) x g(-1) (DeltaMBF, 0.27 +/- 0.25 mL x min(-1) x g(-1)) or 36% +/- 31% (P <or= 0.0001). However, in normal controls without coronary risk factors (n = 22), the epicardial LA increased from 5.01 +/- 1.07 to 5.88 +/- 0.89 mm(2) (19.06% +/- 8.9%) and MBF increased from 0.77 +/- 0.16 to 1.34 +/- 0.34 mL x min(-1) x g(-1) (74.08% +/- 23.5%) during CPT, whereas patients with coronary risk factors (n = 34) revealed a decrease of epicardial LA from 5.13 +/- 1.48 to 4.24 +/- 1.12 mm(2) (-15.94% +/- 12.2%) and a diminished MBF increase (from 0.76 +/- 0.20 to 0.83 +/- 0.25 mL x min(-1) x g(-1) or 10.91% +/- 19.8%) as compared with controls (P < 0.0001, respectively), despite comparable changes in the RPP (P = NS). In addition, there was a significant correlation (r = 0.87; P <or= 0.0001) between CPT-related percent changes in LA on quantitative angiography and in MBF as measured with PET. CONCLUSION: The observed close correlation between an angiographically established parameter of flow-dependent and, most likely, endothelium-mediated coronary vasomotion and PET-measured MBF further supports the validity and value of MBF responses to CPT as a noninvasively available index of coronary circulatory function.
Resumo:
PURPOSE: Neurophysiological monitoring aims to improve the safety of pedicle screw placement, but few quantitative studies assess specificity and sensitivity. In this study, screw placement within the pedicle is measured (post-op CT scan, horizontal and vertical distance from the screw edge to the surface of the pedicle) and correlated with intraoperative neurophysiological stimulation thresholds. METHODS: A single surgeon placed 68 thoracic and 136 lumbar screws in 30 consecutive patients during instrumented fusion under EMG control. The female to male ratio was 1.6 and the average age was 61.3 years (SD 17.7). Radiological measurements, blinded to stimulation threshold, were done on reformatted CT reconstructions using OsiriX software. A standard deviation of the screw position of 2.8 mm was determined from pilot measurements, and a 1 mm of screw-pedicle edge distance was considered as a difference of interest (standardised difference of 0.35) leading to a power of the study of 75 % (significance level 0.05). RESULTS: Correct placement and stimulation thresholds above 10 mA were found in 71 % of screws. Twenty-two percent of screws caused cortical breach, 80 % of these had stimulation thresholds above 10 mA (sensitivity 20 %, specificity 90 %). True prediction of correct position of the screw was more frequent for lumbar than for thoracic screws. CONCLUSION: A screw stimulation threshold of >10 mA does not indicate correct pedicle screw placement. A hypothesised gradual decrease of screw stimulation thresholds was not observed as screw placement approaches the nerve root. Aside from a robust threshold of 2 mA indicating direct contact with nervous tissue, a secondary threshold appears to depend on patients' pathology and surgical conditions.
Resumo:
Purpose: To determine dose thresholds, in term of CTDIvol, where subtle anatomical structures of pediatric CT images becomes no more detectable and compare them to the most recent Reference Dose Levels (DRL) proposed in the UK, Germany and Switzerland. Materials and methods: A GE LightSpeed-Ultra scanner (MSCT 8 slices) was used to perform chest and abdomen acquisitions on 8 patients (age range 2 to 16 years old) to provide a set of gold standard images. Dose reductions were then simulated by introducing image noise on raw data to provide simulated CT images with CTDIvol ranging from 2 to 22 mGy. All images were reviewed and scored independently by four experienced radiologists using the VGA methodology (Visual Grading Analysis) to determine the dose threshold where a significant loss of normal anatomy conspicuity appeared. Data were analyzed with ANOVA and Tukey HSD tests, a p >0.05 was considered to be significant. Results: No significant difference in VGA scoring appeared for CTDIvol leading to image noise levels lower than 10 and 25 HU for respectively abdominal and chest acquisitions. These data can thus be used to set the AEC (automatic exposure control) system of units having similar noise properties than the GE LightSpeed-Ultra used in this study. The present DRLs proposed for pediatric CT acquisitions are compatible with an excellent image quality level. Conclusion: The differences of DRL values proposed in Europe for pediatric acquisitions are marginal and assure a very good image quality level. The results of this study allow to further optimize the acquisition protocol by giving Noise Index value to set the AEC device.
Resumo:
Objective: Integration of the radiotherapy technologist "know-how" in the Gamma Knife treatment processMaterials and Methods: Gamma Knife (GK) treatments started in July 2010 at the GK Center in C.H.U.V. with the Leksell Gamma KnifeR Perfexion?(Elekta AB, Sweden). The multidisciplinary GK team involves neurosurgeons, radio-oncologists, physicists, neuroradiologists, nurses and technologists, aiming at a full integration for optimal patient management.Results: Between July and December 2010, 60 patients have been treated. Required stereotactic imaging involves IRM, CT scan (and angiography for AVM). All the steps in the treatment process (Leksell coordinate frame fixation, imaging, planning, treatment) are supervised by the members of the multidisciplinary team. In our experience, radiotherapy technologist (RTT) have acquired an important role in the multidisciplinary team communication and integration. Specifically, the RTT are responsible of: supervision of the image acquisition, performing the Gamma Knife unit control tests, patient setup, and patient surveillance during treatment.Conclusion: RTT have a fundamental role in the communication within the team, between the team and the patient and also to assure the patient security. Our experience shows that it is possible and required to involve RTT in all steps of the GK treatment process, to guarantee the best GK treatment possible.
Resumo:
PURPOSE: To evaluate the diagnostic performance of abdominal radiography in the detection of illegal intracorporeal containers (hereafter, packets), with low-dose computed tomography (CT) as the reference standard. MATERIALS AND METHODS: This study was approved by the institutional ethical review board, with written informed consent. From July 2007 to July 2010, 330 people (296 men, 34 women; mean age, 32 years [range, 18-55 years]) suspected of having ingested drug packets underwent supine abdominal radiography and low-dose CT. The presence or absence of packets at abdominal radiography was reported, with low-dose CT as the reference standard. The density and number of packets (≤ 12 or >12) at low-dose CT were recorded and analyzed to determine whether those variables influence interpretation of results at abdominal radiography. RESULTS: Packets were detected at low-dose CT in 53 (16%) suspects. Sensitivity of abdominal radiography for depiction of packets was 0.77 (41 of 53), and specificity was 0.96 (267 of 277). The packets appeared isoattenuated to the bowel contents at low-dose CT in 16 (30%) of the 53 suspects with positive results. Nineteen (36%) of the 53 suspects with positive low-dose CT results had fewer than 12 packets. Packets that were isoattenuated at low-dose CT and a low number of packets (≤12) were both significantly associated with false-negative results at abdominal radiography (P = .004 and P = .016, respectively). CONCLUSION: Abdominal radiography is mainly limited by low sensitivity when compared with low-dose CT in the screening of people suspected of carrying drug packets. Low-dose CT is an effective imaging alternative to abdominal radiography.
Resumo:
Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.
Resumo:
OBJECTIVE: Our objective is to describe pouchography, CT, and MRI features of the J-shaped pouch, both normal and with pouch-related complications. CONCLUSION: Pouchography is performed before closure of the loop ileostomy to assess the integrity of the ileal pouch and anastomosis. CT and MRI can be performed when postoperative complications, such as small-bowel obstruction, pouchitis, leakage, abscess, intramural hematoma, desmoid tumor, or recurrent Crohn's disease, are suspected.
Resumo:
The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.