291 resultados para Assessment of pain
Resumo:
Clinical experience and experimental data suggest that intradialytic hemodynamic profiles could be influenced by the characteristics of the dialysis membranes. Even within the worldwide used polysulfone family, intolerance to specific membranes was occasionally evoked. The aim of this study was to compare hemodynamically some of the commonly used polysulfone dialyzers in Switzerland. We performed an open-label, randomized, cross-over trial, including 25 hemodialysis patients. Four polysulfone dialyzers, A (Revaclear high-flux, Gambro, Stockholm, Sweden), B (Helixone high-flux, Fresenius), C (Xevonta high-flux, BBraun, Melsungen, Germany), and D (Helixone low-flux, Fresenius, Bad Homburg vor der Höhe, Germany), were compared. The hemodynamic profile was assessed and patients were asked to provide tolerance feedback. The mean score (±SD) subjectively assigned to dialysis quality on a 1-10 scale was A 8.4 ± 1.3, B 8.6 ± 1.3, C 8.5 ± 1.6, D 8.5 ± 1.5. Kt/V was A 1.58 ± 0.30, B 1.67 ± 0.33, C 1.62 ± 0.32, D 1.45 ± 0.31. The low- compared with the high-flux membranes, correlated to higher systolic (128.1 ± 13.1 vs. 125.6 ± 12.1 mmHg, P < 0.01) and diastolic (76.8 ± 8.7 vs. 75.3 ± 9.0 mmHg; P < 0.05) pressures, higher peripheral resistance (1.44 ± 0.19 vs. 1.40 ± 0.18 s × mmHg/mL; P < 0.05) and lower cardiac output (3.76 ± 0.62 vs. 3.82 ± 0.59 L/min; P < 0.05). Hypotension events (decrease in systolic blood pressure by >20 mmHg) were 70 with A, 87 with B, 73 with C, and 75 with D (P < 0.01 B vs. A, 0.05 B vs. C and 0.07 B vs. D). The low-flux membrane correlated to higher blood pressure levels compared with the high-flux ones. The Helixone high-flux membrane ensured the best efficiency. Unfortunately, the very same dialyzer correlated to a higher incidence of hypotensive episodes.
Resumo:
Main concepts : The Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) approach defines quality of evidence as confidence in effect estimates; this conceptualization can readily be applied to bodies of evidence estimating the risk of future of events (that is, prognosis) in broadly defined populations In the field of prognosis, a body of observational evidence (including single arms of randomized controlled trials) begins as high quality evidence. The five domains GRADE considers in rating down confidence in estimates of treatment effect-that is, risk of bias, imprecision, inconsistency, indirectness, and publication bias-as well as the GRADE criteria for rating up quality, also apply to estimates of the risk of future of events from a body of prognostic studies Applying these concepts to systematic reviews of prognostic studies provides a ful approach to determine confidence in estimates of overall prognosis in broad populations.
Resumo:
BACKGROUND: Pancreaticoduodenectomies (PD) still have a substantial mortality rate. Recently, different scores have been published to predict the mortality risk pre-operatively after PD. This retrospective study was designed to perform an external assessment of an Early Mortality Risk Score (EMRS). METHODS: From 2000 to 2012, all PD cases performed at our institution were documented. Only patients treated for pancreatic head adenocarcinomas were included. Survival time and EMRS (based on age, tumour size, tumour differentiation and comorbidities) were calculated for every patient. Relative risks (RR) of early death 9 and 12 months after PD were then calculated. RESULTS: Of 270 PD for various aetiologies, 120 PD for adenocarcinomas were included. The median follow-up was 37 months, and the overall median survival was 19 months. EMRS of 4 showed a mortality RR of 5.1 at 9 months (P = 0.048) and of 4.5 at 12 months (P = 0.020). CONCLUSIONS: EMRS of 4 is a predictor of tumour-related mortality at 9 and 12 months after PD for adenocarcinoma. The EMRS was externally assessed in our patient cohort and can be implemented in clinical practice. Clinical implications of this score still need to be studied.
Resumo:
BACKGROUND: Port-wine stains (PWS) are malformations of capillaries in 0.3% of newborn children. The treatment of choice is by pulsed dye LASER (PDL), and requires several sessions. The efficacy of this treatment is at present evaluated on the basis of clinical inspection and of digital photographs taken throughout the treatment. LASER-Doppler imaging (LDI) is a noninvasive method of imaging the perfusion of the tissues by the microcirculatory system (capillaries). The aim of this paper is to demonstrate that LDI allows a quantitative, numerical evaluation of the efficacy of the PDL treatment of PWS. METHOD: The PDL sessions were organized according to the usual scheme, every other month, from September 1, 2012, to September 30, 2013. LDI imaging was performed at the start and at the conclusion of the PDL treatment, and simultaneously on healthy skin in order to obtain reference values. The results evidenced by LDI were analyzed according to the "Wilcoxon signed-rank" test before and after each session, and in the intervals between the three PDL treatment sessions. RESULTS: Our prospective study is based on 20 new children. On average, the vascularization of the PWS was reduced by 56% after three laser sessions. Compared with healthy skin, initial vascularization of PWS was 62% higher than that of healthy skin at the start of treatment, and 6% higher after three sessions. During the 2 months between two sessions, vascularization of the capillary network increased by 27%. CONCLUSION: This study shows that LDI can demonstrate and measure the efficacy of PDL treatment of PWS in children. The figures obtained when measuring the results by LDI corroborate the clinical assessments and may allow us to refine, and perhaps even modify, our present use of PDL and thus improve the efficacy of the treatment.
Resumo:
Children with Wiskott-Aldrich syndrome (WAS) are often first diagnosed with immune thrombocytopenia (ITP), potentially leading to both inappropriate treatment and the delay of life-saving definitive therapy. WAS is traditionally differentiated from ITP based on the small size of WAS platelets. In practice, microthrombocytopenia is often not present or not appreciated in children with WAS. To develop an alternative method of differentiating WAS from ITP, we retrospectively reviewed all complete blood counts and measurements of immature platelet fraction (IPF) in 18 subjects with WAS and 38 subjects with a diagnosis of ITP treated at our hospital. Examination of peripheral blood smears revealed a wide range of platelet sizes in subjects with WAS. Mean platelet volume (MPV) was not reported in 26% of subjects, and subjects in whom MPV was not reported had lower platelet counts than did subjects in whom MPV was reported. Subjects with WAS had a lower IPF than would be expected for their level of thrombocytopenia, and the IPF in subjects with WAS was significantly lower than in subjects with a diagnosis of ITP. Using logistic regression, we developed and validated a rule based on platelet count and IPF that was more sensitive for the diagnosis of WAS than was the MPV, and was applicable regardless of the level of platelets or the availability of the MPV. Our observations demonstrate that MPV is often not available in severely thrombocytopenic subjects, which may hinder the diagnosis of WAS. In addition, subjects with WAS have a low IPF, which is consistent with the notion that a platelet production defect contributes to the thrombocytopenia of WAS. Knowledge of this detail of WAS pathophysiology allows to differentiate WAS from ITP with increased sensitivity, thereby allowing a physician to spare children with WAS from inappropriate treatment, and make definitive therapy available in a timely manner.
Resumo:
BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.
Resumo:
Regulation has in many cases been delegated to independent agencies, which has led to the question of how democratic accountability of these agencies is ensured. There are few empirical approaches to agency accountability. We offer such an approach, resting upon three propositions. First, we scrutinize agency accountability both de jure (accountability is ensured by formal rights of accountability 'fora' to receive information and impose consequences) and de facto (the capability of fora to use these rights depends on resources and decision costs that affect the credibility of their sanctioning capacity). Second, accountability must be evaluated separately at political, operational and managerial levels. And third, at each level accountability is enacted by a system of several (partially) interdependent fora, forming together an accountability regime. The proposed framework is applied to the case of the German Bundesnetzagentur's accountability regime, which shows its suitability for empirical purposes. Regulatory agencies are often considered as independent, yet accountable. This article provides a realistic framework for the study of accountability 'regimes' in which they are embedded. It emphasizes the need to identify the various actors (accountability fora) to which agencies are formally accountable (parliamentary committees, auditing bodies, courts, and so on) and to consider possible relationships between them. It argues that formal accountability 'on paper', as defined in official documents, does not fully account for de facto accountability, which depends on the resources possessed by the fora (mainly information-processing and decision-making capacities) and the credibility of their sanctioning capacities. The article applies this framework to the German Bundesnetzagentur.
Resumo:
INTRODUCTION: Two important risk factors for abnormal neurodevelopment are preterm birth and neonatal hypoxic ischemic encephalopathy. The new revisions of Griffiths Mental Development Scale (Griffiths-II, [1996]) and the Bayley Scales of Infant Development (BSID-II, [1993]) are two of the most frequently used developmental diagnostics tests. The Griffiths-II is divided into five subscales and a global development quotient (QD), and the BSID-II is divided into two scales, the Mental scale (MDI) and the Psychomotor scale (PDI). The main objective of this research was to establish the extent to which developmental diagnoses obtained using the new revisions of these two tests are comparable for a given child. MATERIAL AND METHODS: Retrospective study of 18-months-old high-risk children examined with both tests in the follow-up Unit of the Clinic of Neonatology of our tertiary care university Hospital between 2011 and 2012. To determine the concurrent validity of the two tests paired t-tests and Pearson product-moment correlation coefficients were computed. Using the BSID-II as a gold standard, the performance of the Griffiths-II was analyzed with receiver operating curves. RESULTS: 61 patients (80.3% preterm, 14.7% neonatal asphyxia) were examined. For the BSID-II the MDI mean was 96.21 (range 67-133) and the PDI mean was 87.72 (range 49-114). For the Griffiths-II, the QD mean was 96.95 (range 60-124), the locomotors subscale mean was 92.57 (range 49-119). The score of the Griffiths locomotors subscale was significantly higher than the PDI (p<0.001). Between the Griffiths-II QD and the BSID-II MDI no significant difference was found, and the area under the curve was 0.93, showing good validity. All correlations were high and significant with a Pearson product-moment correlation coefficient >0.8. CONCLUSIONS: The meaning of the results for a given child was the same for the two tests. Two scores were interchangeable, the Griffiths-II QD and the BSID-II MDI.
Resumo:
Background.- The main goals of the European Board of Physical and Rehabili-tation Medicine (EBPRM), founded in 1991 as the third speciality board of theUnion of European Medical Specialists (UEMS), are to harmonize pre-graduate,post-graduate and continuous medical education in physical and rehabilitationmedicine (PRM) all over Europe. The harmonization of curricula of the medi-cal specialities and the assessment of medical specialists has become one of thepriorities of the UEMS and its working groups to which the EBPRM contributes.Action.- The EBPRM will continue to promote a specific minimal undergraduatecurriculum on PRM including issues like disability, participation and handicapto be taught all over Europe as a basis for general medical practice. The EBPRMwill also expand the existing EBPRM postgraduate curriculum into a detailedcatalogue of learning objectives. This catalogue will serve as a tool to boostharmonization of the national curricula across Europe as well as to structurethe content of the MCQ examination. It would be a big step forward towardsharmonization of European PRM specialist training if an important number ofcountries would use the certifying MCQ examination of the Board as a part ofthe national assessments for PRM specialists.
Resumo:
PURPOSE: Iterative algorithms introduce new challenges in the field of image quality assessment. The purpose of this study is to use a mathematical model to evaluate objectively the low contrast detectability in CT. MATERIALS AND METHODS: A QRM 401 phantom containing 5 and 8 mm diameter spheres with a contrast level of 10 and 20 HU was used. The images were acquired at 120 kV with CTDIvol equal to 5, 10, 15, 20 mGy and reconstructed using the filtered back-projection (FBP), adaptive statistical iterative reconstruction 50% (ASIR 50%) and model-based iterative reconstruction (MBIR) algorithms. The model observer used is the Channelized Hotelling Observer (CHO). The channels are dense difference of Gaussian channels (D-DOG). The CHO performances were compared to the outcomes of six human observers having performed four alternative forced choice (4-AFC) tests. RESULTS: For the same CTDIvol level and according to CHO model, the MBIR algorithm gives the higher detectability index. The outcomes of human observers and results of CHO are highly correlated whatever the dose levels, the signals considered and the algorithms used when some noise is added to the CHO model. The Pearson coefficient between the human observers and the CHO is 0.93 for FBP and 0.98 for MBIR. CONCLUSION: The human observers' performances can be predicted by the CHO model. This opens the way for proposing, in parallel to the standard dose report, the level of low contrast detectability expected. The introduction of iterative reconstruction requires such an approach to ensure that dose reduction does not impair diagnostics.