261 resultados para subglottic stenosis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Coronary artery disease (CAD) continues to be one of the top public health burden. Perfusion cardiovascular magnetic resonance (CMR) is generally accepted to detect CAD, while data on its cost effectiveness are scarce. Therefore, the goal of the study was to compare the costs of a CMR-guided strategy vs two invasive strategies in a large CMR registry. METHODS: In 3'647 patients with suspected CAD of the EuroCMR-registry (59 centers/18 countries) costs were calculated for diagnostic examinations (CMR, X-ray coronary angiography (CXA) with/without FFR), revascularizations, and complications during a 1-year follow-up. Patients with ischemia-positive CMR underwent an invasive CXA and revascularization at the discretion of the treating physician (=CMR + CXA-strategy). In the hypothetical invasive arm, costs were calculated for an initial CXA and a FFR in vessels with ≥50 % stenoses (=CXA + FFR-strategy) and the same proportion of revascularizations and complications were applied as in the CMR + CXA-strategy. In the CXA-only strategy, costs included those for CXA and for revascularizations of all ≥50 % stenoses. To calculate the proportion of patients with ≥50 % stenoses, the stenosis-FFR relationship from the literature was used. Costs of the three strategies were determined based on a third payer perspective in 4 healthcare systems. RESULTS: Revascularizations were performed in 6.2 %, 4.5 %, and 12.9 % of all patients, patients with atypical chest pain (n = 1'786), and typical angina (n = 582), respectively; whereas complications (=all-cause death and non-fatal infarction) occurred in 1.3 %, 1.1 %, and 1.5 %, respectively. The CMR + CXA-strategy reduced costs by 14 %, 34 %, 27 %, and 24 % in the German, UK, Swiss, and US context, respectively, when compared to the CXA + FFR-strategy; and by 59 %, 52 %, 61 % and 71 %, respectively, versus the CXA-only strategy. In patients with typical angina, cost savings by CMR + CXA vs CXA + FFR were minimal in the German (2.3 %), intermediate in the US and Swiss (11.6 % and 12.8 %, respectively), and remained substantial in the UK (18.9 %) systems. Sensitivity analyses proved the robustness of results. CONCLUSIONS: A CMR + CXA-strategy for patients with suspected CAD provides substantial cost reduction compared to a hypothetical CXA + FFR-strategy in patients with low to intermediate disease prevalence. However, in the subgroup of patients with typical angina, cost savings were only minimal to moderate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

NlmCategory="UNASSIGNED">Rapid deployment aortic valve replacement (RDAVR) with the use of rapid deployment valve systems represents a smart alternative to the use of standard aortic bioprosthesis for aortic valve replacement. Nevertheless, its use is still debatable in patients with pure aortic valve regurgitation or true bicuspid aortic valve because of the risk of postoperative paravalvular leak. To address this issue, an optimal annulus-valve size match seems to be the ideal surgical strategy. This article describes a new technique developed to stabilize the aortic annulus and prevent paravalvular leak after RDAVR. To confirm the feasibility, this technique was performed in six patients with severe symptomatic aortic stenosis who were scheduled to undergo aortic valve replacement at our center. All patients survived surgery and were discharged from the hospital. There were no new intracardiac conduction system disturbances observed, and a permanent pacemaker implantation was not required in any of the patients. The intraoperative and postoperative echocardiogram confirmed successful positioning of the valve, and no paravalvular leak was observed. In this preliminary experience, RDAVR through a full sternotomy or an upper hemisternotomy approach with the use of aortic annulus stabilization technique was safe, and no leak was observed. Future studies on large series of patients are necessary to confirm the safety and effectiveness of this technique in preventing paravalvular leak in patients with true bicuspid aortic valves or pure aortic regurgitation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a retrospective study on 22 operations of exostosis of the external auditory canal in 20 patients. 8 patients were passionated by water sports. The most frequent indication for surgery (13 operations) was recurrent external otitis or ceruminal obstruction. In 7 cases the need for a wider access to the middle ear indicated surgery. Surgery was usually performed as an outpatient procedure, maximum hospitalization was 3 days. The mean healing period was 6 (3-10) weeks. Mean follow up was 43 (3-110) months. There were no severe intraoperative complications such as facial paresis, lesions of the ossicles or of the inner ear. As intraoperative complications we found 2 perforations of the tympanic membrane, 2 expositions of the capsule of the mandibular joint, one of which was followed by chronic pain. As postoperative complications we found an early soft tissue stenosis of the external auditory canal and one late soft tissue stenosis which recurred after revision surgery. No recurrence of exostosis was seen. We describe an up to now unknown complication: the appearance of bilateral petrositis caused by staphylococcus epidermidis after bilateral surgery in an otherwise healthy patient. This study confirms that severe complications are rare, minor ones however relatively common. And that also minor complications may have a troublesome follow. Therefore and because of the potential of severe complications indication for surgery must be made cautiously and risks of the operation must not be underestimated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since routine eubacterial 16S rRNA PCR does not amplify members of the Chlamydiales order, we tested all samples received in our laboratory during a 10 months period using a pan-Chlamydiales real-time PCR. 3 of 107 samples (2.8%) revealed to be positive, suggesting a role of some Chlamydiales in the pathogenesis of chronic bronchial stenosis or bronchial stenosis superinfection and as agents of orthopaedic prosthesis infections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Voluntary methadone administration for the purpose of sedation eventually resulting in the infant's death is extremely infrequent, though it has been observed. In this report, we describe an autopsy case pertaining to a 32-month-old infant who was repeatedly exposed to methadone by his parents. Autopsy revealed a coarctation of the aorta with a focal stenosis located at the junction of the distal aortic arch and the descending aorta. Left ventricular hypertrophy was also observed. Both these findings were considered to not have played a role in the child's death. Methadone was detected in the femoral blood (0.633 mg/l), urine (5.25 mg/l), bile (2.64 mg/l), and gastric contents (1.08 mg). A segmental hair analysis showed the presence of methadone and morphine in both the proximal and distal portion of the lock. Methadone was also detected in nail samples. A segmental hair analysis performed on the younger brother of the deceased revealed the presence of methadone and morphine in both the proximal and distal segments, as well as the presence of 6-monoacetylmorphine exclusively in the distal portion. Though the parents denied any involvement in methadone administration or exposure for the purpose of sedation, the manner of death was listed as homicide. The case emphasizes the usefulness of hair analysis to identify threatening situations for the children of drug-dependent parents and possibly support measures by the authorities to recognize and intervene in these potentially fatal situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Due to the high prevalence of renal failure in transcatheter aortic valve replacement (TAVR) candidates, a non-contrast MR technique is desirable for pre-procedural planning. We sought to evaluate the feasibility of a novel, non-contrast, free-breathing, self-navigated three-dimensional (SN3D) MR sequence for imaging the aorta from its root to the iliofemoral run-off in comparison to non-contrast two-dimensional-balanced steady-state free-precession (2D-bSSFP) imaging. METHODS: SN3D [field of view (FOV), 220-370 mm(3); slice thickness, 1.15 mm; repetition/echo time (TR/TE), 3.1/1.5 ms; and flip angle, 115°] and 2D-bSSFP acquisitions (FOV, 340 mm; slice thickness, 6 mm; TR/TE, 2.3/1.1 ms; flip angle, 77°) were performed in 10 healthy subjects (all male; mean age, 30.3 ± 4.3 yrs) using a 1.5-T MRI system. Aortic root measurements and qualitative image ratings (four-point Likert-scale) were compared. RESULTS: The mean effective aortic annulus diameter was similar for 2D-bSSFP and SN3D (26.7 ± 0.7 vs. 26.1 ± 0.9 mm, p = 0.23). The mean image quality of 2D-bSSFP (4; IQR 3-4) was rated slightly higher (p = 0.03) than SN3D (3; IQR 2-4). The mean total acquisition time for SN3D imaging was 12.8 ± 2.4 min. CONCLUSIONS: Our results suggest that a novel SN3D sequence allows rapid, free-breathing assessment of the aortic root and the aortoiliofemoral system without administration of contrast medium. KEY POINTS: • The prevalence of renal failure is high among TAVR candidates. • Non-contrast 3D MR angiography allows for TAVR procedure planning. • The self-navigated sequence provides a significantly reduced scanning time.