265 resultados para pelvis radiography
Resumo:
Transarterial radioembolization consist in delivering small particles loaded with Yttrium90, a pure beta emitter, in order to treat primary and secondary liver tumors. This treatment needs precaution since inadequate delivery of these beads can lead to severe complications. Moreover, a precise radiation dosing is crucial to achieve a good clinical success and to avoid complications such as radioembolization-induced liver disease. This review describes all the precautions and highlights clinical and technical considerations that need to be taken to avoid complications.
Resumo:
OBJECTIVES: To determine inter-session and intra/inter-individual variations of the attenuations of aortic blood/myocardium with MDCT in the context of calcium scoring. To evaluate whether these variations are dependent on patients' characteristics. METHODS: Fifty-four volunteers were evaluated with calcium scoring non-enhanced CT. We measured attenuations (inter-individual variation) and standard deviations (SD, intra-individual variation) of the blood in the ascending aorta and of the myocardium of left ventricle. Every volunteer was examined twice to study the inter-session variation. The fat pad thickness at the sternum and noise (SD of air) were measured too. These values were correlated with the measured aortic/ventricular attenuations and their SDs (Pearson). Historically fixed thresholds (90 and 130 HU) were tested against different models based on attenuations of blood/ventricle. RESULTS: The mean attenuation was 46 HU (range, 17-84 HU) with mean SD 23 HU for the blood, and 39 HU (10-82 HU) with mean SD 18 HU for the myocardium. The attenuation/SD of the blood were significantly higher than those of the myocardium (p < 0.01). The inter-session variation was not significant. There was a poor correlation between SD of aortic blood/ventricle with fat thickness/noise. Based on existing models, 90 HU threshold offers a confidence interval of approximately 95% and 130 HU more than 99%. CONCLUSIONS: Historical thresholds offer high confidence intervals for exclusion of aortic blood/myocardium and by the way for detecting calcifications. Nevertheless, considering the large variations of blood/myocardium CT values and the influence of patient's characteristics, a better approach might be an adaptive threshold.
Resumo:
Adenosine deaminase-deficient severe combined immunodeficiency (ADA-SCID) is characterized by impaired T-, B- and NK-cell function. Affected children, in addition to early onset of infections, manifest non-immunologic symptoms including pulmonary dysfunction likely attributable to elevated systemic adenosine levels. Lung disease assessment has primarily employed repetitive radiography and effort-dependent functional studies. Through impulse oscillometry (IOS), which is effort-independent, we prospectively obtained objective measures of lung dysfunction in 10 children with ADA-SCID. These results support the use of IOS in the identification and monitoring of lung function abnormalities in children with primary immunodeficiencies.
Resumo:
Right ventricular (RV) rupture in cases of mediastinitis following cardiac surgery is a rare and dangerous complication. Bleeding from the right ventricle occurs mainly after sternal reopening, due to either iatrogenic manipulation (wire removal, lesions due to wiring maneuvers) or mechanical shearing forces, producing direct injury. We present a case of RV wall perforation due to infection in a recurrent postoperative mediastinitis with a closed chest. The current literature on treatment of postoperative mediastinitis is also reviewed.
Resumo:
UNLABELLED: Trabecular bone score (TBS) seems to provide additive value on BMD to identify individuals with prevalent fractures in T1D. TBS did not significantly differ between T1D patients and healthy controls, but TBS and HbA1c were independently associated with prevalent fractures in T1D. A TBS cutoff <1.42 reflected prevalent fractures with 91.7 % sensitivity and 43.2 % specificity. INTRODUCTION: Type 1 diabetes (T1D) increases the risk of osteoporotic fractures. TBS was recently proposed as an indirect measure of bone microarchitecture. This study aimed at investigating the TBS in T1D patients and healthy controls. Associations with prevalent fractures were tested. METHODS: One hundred nineteen T1D patients (59 males, 60 premenopausal females; mean age 43.4 ± 8.9 years) and 68 healthy controls matched for gender, age, and body mass index (BMI) were analyzed. The TBS was calculated in the lumbar region, based on two-dimensional (2D) projections of DXA assessments. RESULTS: TBS was 1.357 ± 0.129 in T1D patients and 1.389 ± 0.085 in controls (p = 0.075). T1D patients with prevalent fractures (n = 24) had a significantly lower TBS than T1D patients without fractures (1.309 ± 0.125 versus 1.370 ± 0.127, p = 0.04). The presence of fractures in T1D was associated with lower TBS (odds ratio = 0.024, 95 % confidence interval (CI) = 0.001-0.875; p = 0.042) but not with age or BMI. TBS and HbA1c were independently associated with fractures. The area-under-the curve (AUC) of TBS was similar to that of total hip BMD in discriminating T1D patients with or without prevalent fractures. In this set-up, a TBS cutoff <1.42 discriminated the presence of fractures with a sensitivity of 91.7 % and a specificity of 43.2 %. CONCLUSIONS: TBS values are lower in T1D patients with prevalent fractures, suggesting an alteration of bone strength in this subgroup of patients. Reliable TBS cutoffs for the prediction of fracture risk in T1D need to be determined in larger prospective studies.
Resumo:
Les interactions entre les systèmes de régulation du sodium et du calcium sont encore mal comprises et leur importance clinique mérite d'être étudiée plus en détail. Les études chez l'animal ont montré qu'il existe des relations entre le taux plasmatique d'hormone parathyroïdienne (PTH) et l'aldostérone ou l'activité de la rénine. Par ailleurs, il a été démontré chez l'animal et chez l'homme que le taux sanguin de PTH augmente rapidement après une injection de furosémide, un diurétique de l'anse ce qui fait penser qu'il existe un lien entre l'effet du furosémide sur le rein et la sécrétion de PTH. Toutefois, à ce jour, le(s) mécanisme(s) impliqués dans ce lien reste(nt) encore inconnu(s). Des résultats plus récents suggèrent que l'effet du furosemide est amoindri par l'administration préalable d'un calcimimétique agissant au niveau du récepteur sensible au calcium (calcium sensing receptor). Pour explorer chez l'homme, les mécanismes possibles du lien entre PTH et effet du furosemide sur le rein, nous avons planifié une étude randomisée croisée contre placebo réalisée chez 18 volontaires sains masculins. Le but principal était d'investiguer le rôle du système rénine-angiotensine et des calcium sensing receptors. L'étude s'est donc réalisée en 2 phases pour chaque sujet. Les participants ont ainsi reçu soit du cinacalcet (60mg) soit un placebo dans une première phase et le placebo ou du cinacalcet dans la 2° phase. Dans chaque phase d'évaluation, une injection de 20 mg de furosemide a été administrée par voie intraveineuse à l'équilibre soit 3 heures après la prise du placebo ou du cinacalcet. Des échantillons de plasma ont été prélevés toutes les 15 minutes pendant 1 heure puis toutes les heures pour le dosage de PTH intacte, calcium, sodium, potassium, magnésium, phosphate, activité de la rénine plasmatique et aldostérone jusqu'à 6h après l'injection de furosémide. L'excrétion urinaire de ces mêmes électrolytes a été mesurée aux mêmes intervalles.
Resumo:
NlmCategory="UNASSIGNED">A version of cascaded systems analysis was developed specifically with the aim of studying quantum noise propagation in x-ray detectors. Signal and quantum noise propagation was then modelled in four types of x-ray detectors used for digital mammography: four flat panel systems, one computed radiography and one slot-scan silicon wafer based photon counting device. As required inputs to the model, the two dimensional (2D) modulation transfer function (MTF), noise power spectra (NPS) and detective quantum efficiency (DQE) were measured for six mammography systems that utilized these different detectors. A new method to reconstruct anisotropic 2D presampling MTF matrices from 1D radial MTFs measured along different angular directions across the detector is described; an image of a sharp, circular disc was used for this purpose. The effective pixel fill factor for the FP systems was determined from the axial 1D presampling MTFs measured with a square sharp edge along the two orthogonal directions of the pixel lattice. Expectation MTFs were then calculated by averaging the radial MTFs over all possible phases and the 2D EMTF formed with the same reconstruction technique used for the 2D presampling MTF. The quantum NPS was then established by noise decomposition from homogenous images acquired as a function of detector air kerma. This was further decomposed into the correlated and uncorrelated quantum components by fitting the radially averaged quantum NPS with the radially averaged EMTF(2). This whole procedure allowed a detailed analysis of the influence of aliasing, signal and noise decorrelation, x-ray capture efficiency and global secondary gain on NPS and detector DQE. The influence of noise statistics, pixel fill factor and additional electronic and fixed pattern noises on the DQE was also studied. The 2D cascaded model and decompositions performed on the acquired images also enlightened the observed quantum NPS and DQE anisotropy.
Resumo:
BACKGROUND: Although the importance of accurate femoral reconstruction to achieve a good functional outcome is well documented, quantitative data on the effects of a displacement of the femoral center of rotation on moment arms are scarce. The purpose of this study was to calculate moment arms after nonanatomical femoral reconstruction. METHODS: Finite element models of 15 patients including the pelvis, the femur, and the gluteal muscles were developed. Moment arms were calculated within the native anatomy and compared to distinct displacement of the femoral center of rotation (leg lengthening of 10 mm, loss of femoral offset of 20%, anteversion ±10°, and fixed anteversion at 15°). Calculations were performed within the range of motion observed during a normal gait cycle. RESULTS: Although with all evaluated displacements of the femoral center of rotation, the abductor moment arm remained positive, some fibers initially contributing to extension became antagonists (flexors) and vice versa. A loss of 20% of femoral offset led to an average decrease of 15% of abductor moment. Femoral lengthening and changes in femoral anteversion (±10°, fixed at 15°) led to minimal changes in abductor moment arms (maximum change of 5%). Native femoral anteversion correlated with the changes in moment arms induced by the 5 variations of reconstruction. CONCLUSION: Accurate reconstruction of offset is important to maintaining abductor moment arms, while changes of femoral rotation had minimal effects. Patients with larger native femoral anteversion appear to be more susceptible to femoral head displacements.
Resumo:
BACKGROUND: The use of a robotic surgical system is claimed to allow precise traction and counter-traction, especially in a narrow pelvis. Whether this translates to improvement of the quality of the resected specimen is not yet clear. The aim of the study was to compare the quality of the TME and the short-term oncological outcome between robotic and laparoscopic rectal cancer resections. METHODS: 20 consecutive robotic TME performed in a single institution for rectal cancer (Rob group) were matched 1:2 to 40 laparoscopic resections (Lap group) for gender, body mass index (BMI), and distance from anal verge on rigid proctoscopy. The quality of TME was assessed by 2 blinded and independent pathologists and reported according to international standardized guidelines. RESULTS: Both samples were well matched for gender, BMI (median 25.9 vs. 24.2 kg/m(2), p = 0.24), and level of the tumor (4.1 vs. 4.8 cm, p = 0.20). The quality of the TME was better in the Robotic group (complete TME: 95 vs. 55 %; p = 0.0003, nearly complete TME 5 vs. 37 %; p = 0.04, incomplete TME 0 vs. 8 %, p = 0.09). A trend for lower positive circumferential margin was observed in the Robotic group (10 vs. 25 %, p = 0.1). CONCLUSIONS: These results suggest that robotic-assisted surgery improves the quality of TME for rectal cancer. Whether this translates to better oncological outcome needs to be further investigated.
Resumo:
BACKGROUND: Abdominoperineal resection (APR) following radiotherapy is associated with a high rate of perineal wound complications. The anterolateral thigh (ALT) flap, combined with the vastus lateralis (VL) muscle, can cover complex perineal and pelvic anteroposterior defects. This is used for the first time transabdominally through the pelvis and the perineum (TAPP) in the infero-posterior directions; this technique has been described and illustrated in this study. METHODS: Among over 90 patients who underwent perineal reconstruction between May 2004 and June 2011, six patients presented high-grade tumours invading perineum, pelvis and sacrum, thereby resulting in a continuous anteroposterior defect. ALT + VL TAPP reconstructions were performed after extended APR and, subsequently, sacrectomy. Patients were examined retrospectively to determine demographics, operative time, complications (general and flap-related), time to complete healing and length of hospital stay. Long-term flap coverage, flap volume stability and functional and aesthetic outcomes were assessed. RESULTS: Mean operating time of the reconstruction was 290 min. No deaths occurred. One patient presented partial flap necrosis. Another patient presented a novel wound dehiscence after flap healing, due to secondary skin dissemination of the primary tumour. Following volumetric flap analysis on serial post-operative CT scans, no significant flap atrophy was observed. All flaps fully covered the defects. No late complications such as fistulas or perineal hernias occurred. Donor-site recovery was uneventful with no functional deficits. CONCLUSIONS: The use of the ALT + VL flap transabdominally is an innovative method to reconstruct exceptionally complex perineal and pelvic defects extending up to the lower back. This flap guarantees superior bulk, obliterating all pelvic dead space, with the fascia lata (FL) supporting the pelvic floor.