258 resultados para free pulse


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Autologous blood transfusion (ABT) efficiently increases sport performance and is the most challenging doping method to detect. Current methods for detecting this practice center on the plasticizer di(2-ethlyhexyl) phthalate (DEHP), which enters the stored blood from blood bags. Quantification of this plasticizer and its metabolites in urine can detect the transfusion of autologous blood stored in these bags. However, DEHP-free blood bags are available on the market, including n-butyryl-tri-(n-hexyl)-citrate (BTHC) blood bags. Athletes may shift to using such bags to avoid the detection of urinary DEHP metabolites. STUDY DESIGN AND METHODS: A clinical randomized double-blinded two-phase study was conducted of healthy male volunteers who underwent ABT using DEHP-containing or BTHC blood bags. All subjects received a saline injection for the control phase and a blood donation followed by ABT 36 days later. Kinetic excretion of five urinary DEHP metabolites was quantified with liquid chromatography coupled with tandem mass spectrometry. RESULTS: Surprisingly, considerable levels of urinary DEHP metabolites were observed up to 1 day after blood transfusion with BTHC blood bags. The long-term metabolites mono-(2-ethyl-5-carboxypentyl) phthalate and mono-(2-carboxymethylhexyl) phthalate were the most sensitive biomarkers to detect ABT with BTHC blood bags. Levels of DEHP were high in BTHC bags (6.6%), the tubing in the transfusion kit (25.2%), and the white blood cell filter (22.3%). CONCLUSIONS: The BTHC bag contained DEHP, despite being labeled DEHP-free. Urinary DEHP metabolite measurement is a cost-effective way to detect ABT in the antidoping field even when BTHC bags are used for blood storage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Limited evidence exists to suggest that the ability to invade and escape protozoan host cell bactericidal activity extends to members of the Chlamydiaceae, intracellular pathogens of humans and animals and evolutionary descendants of amoeba-resisting Chlamydia-like organisms. PCR and microscopic analyses of Chlamydophila abortus infections of Acanthamoeba castellani revealed uptake of this chlamydial pathogen but, unlike the well-described inhabitant of A. castellani, Parachlamydia acanthamoebae, Cp. abortus did not appear to propagate and is likely digested by its amoebal host. These data raise doubts about the ability of free-living amoebae to serve as hosts and vectors of pathogenic members of the Chlamydiaceae but reveal opportunities, via comparative genomics, to understand virulence mechanisms used by Chlamydia-like organisms to avoid amoebal digestion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular disease is the leading cause of death worldwide. Within this subset, coronary artery disease (CAD) is the most prevalent. Magnetic resonance angiography (MRA) is an emerging technique that provides a safe, non-invasive way of assessing CAD progression. To generate contrast between tissues, MR images are weighted according to the magnetic properties of those tissues. In cardiac MRI, T2 contrast, which is governed by the rate of transverse signal loss, is often created through the use of a T2-Preparation module. T2-Preparation, or T2-Prep, is a magnetization preparation scheme used to improve blood/myocardium contrast in cardiac MRI. T2-Prep methods generally use a non-selective +90°, 180°, 180°, -90° train of radiofrequency (RF) pulses (or variant thereof), to tip magnetization into the transverse plane, allow it to evolve, and then to restore it to the longitudinal plane. A key feature in this process is the combination of a +90° and -90° RF pulse. By changing either one of these, a mismatch occurs between signal excitation and restoration. This feature can be exploited to provide additional spectral or spatial selectivity. In this work, both of these possibilities are explored. The first - spectral selectivity - has been examined as a method of improving fat saturation in coronary MRA. The second - spatial selectivity - has been examined as a means of reducing imaging time by decreasing the field of view, and as a method of reducing artefacts originating from the tissues surrounding the heart. Two additional applications, parallel imaging and self-navigation, are also presented. This thesis is thus composed of four sections. The first, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", was originally published in the journal Magnetic Resonance in Medicine (MRM) with co-authors Ruud B. van Heeswijk and Matthias Stuber. The second, "Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", again with co-authors Ruud van Heeswijk and Matthias Stuber, was also published in the journal MRM. The third, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA-accelerated image quality in MRA of the right coronary artery", written with co-authors Jerome Yerly and Matthias Stuber, has been submitted to the "Journal of Cardiovascular Magnetic Resonance", and the fourth, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", with co¬authors Jerome Chaptinel, Giulia Ginami, Gabriele Bonanno, Simone Coppo, Ruud van Heeswijk, Davide Piccini, and Matthias Stuber, is undergoing internal review prior to submission to the journal MRM. -- Les maladies cardiovasculaires sont la cause principale de décès dans le monde : parmi celles-ci, les maladies coronariennes sont les plus répandues. L'angiographie par résonance magnétique (ARM) est une technique émergente qui fournit une manière sûre, non invasive d'évaluer la progression de la coronaropathie. Pour obtenir un contraste entre les tissus, les images d'IRM sont pondérées en fonction des propriétés magnétiques de ces tissus. En IRM cardiaque, le contraste en T2, qui est lié à la décroissance du signal transversal, est souvent créé grâce à l'utilisàtion d'un module de préparation T2. La préparation T2, ou T2-Prep, est un système de préparation de l'aimantation qui est utilisé pour améliorer le contraste entre le sang et le myocarde lors d'une IRM cardiaque. Les méthodes de T2-Prep utilisent généralement une série non-sélective d'impulsions de radiofréquence (RF), typiquement [+ 90°, 180°, 180°, -90°] ou une variante, qui bascule l'aimantation dans le plan transversal, lui permet d'évoluer, puis la restaure dans le plan longitudinal. Un élément clé de ce processus est la combinaison des impulsions RF de +90° et -90°. En changeant l'une ou l'autre des impulsions, un décalage se produit entre l'excitation du signal et de la restauration. Cette fonction peut être exploitée pour fournir une sélectivité spectrale ou spatiale. Dans cette thèse, les deux possibilités sont explorées. La première - la sélectivité spectrale - a été examinée comme une méthode d'améliorer la saturation de la graisse dans l'IRM coronarienne. La deuxième - la sélectivité spatiale - a été étudiée comme un moyen de réduire le temps d'imagerie en diminuant le champ de vue, et comme une méthode de réduction des artefacts provenant des tissus entourant le coeur. Deux applications supplémentaires, l'imagerie parallèle et la self-navigation, sont également présentées. Cette thèse est ainsi composée de quatre sections. La première, "A Fat Signal Suppression for Coronary MRA at 3T using a Water-Selective Adiabatic T2-Preparation Technique", a été publiée dans la revue médicale Magnetic Resonance .in Medicine (MRM) avec les co-auteurs Ruud B. van Heeswijk et Matthias Stuber. La deuxième, Combined T2-Preparation and 2D Pencil Beam Inner Volume Selection", encore une fois avec les co-auteurs Ruud van Heeswijk et Matthias Stuber, a également été publiée dans le journal MRM. La troisième, "A cylindrical, inner volume selecting 2D-T2-Prep improves GRAPPA- accelerated image quality in MRA of the right coronary artery", écrite avec les co-auteurs Jérôme Yerly et Matthias Stuber, a été présentée au "Journal of Cardiovascular Magnetic Resonance", et la quatrième, "Combined respiratory self-navigation and 'pencil-beam' 2D-T2 -Prep for free-breathing, whole-heart coronary MRA", avec les co-auteurs Jérôme Chaptinel, Giulia Ginami, Gabriele Bonanno , Simone Coppo, Ruud van Heeswijk, Davide Piccini, et Matthias Stuber, subit un examen interne avant la soumission à la revue MRM.