387 resultados para Phasor angle monitoring
Resumo:
Embryonic stem (ES) cell-derived cardiomyocytes recapitulate cardiomyogenesis in vitro and are a potential source of cells for cardiac repair. However, this requires enrichment of mixed populations of differentiating ES cells into cardiomyocytes. Toward this goal, we have generated bicistronic vectors that express both the blasticidin S deaminase (bsd) gene and a fusion protein consisting of either myosin light chain (MLC)-3f or human alpha-actinin 2A and enhanced green fluorescent protein (EGFP) under the transcriptional control of the alpha-cardiac myosin heavy chain (alpha-MHC) promoter. Insertion of the DNase I-hypersensitive site (HS)-2 element from the beta-globin locus control region, which has been shown to reduce transgene silencing in other cell systems, upstream of the transgene promoter enhanced MLC3f-EGFP gene expression levels in mouse ES cell lines. The alpha-MHC-alpha-actinin-EGFP, but not the alpha-MHC-MLC3f-EGFP, construct resulted in the correct incorporation of the newly synthesized fusion protein at the Z-band of the sarcomeres in ES cell-derived cardiomyocytes. Exposure of embryoid bodies to blasticidin S selected for a relatively pure population of cardiomyocytes within 3 days. Myofibrillogenesis could be monitored by fluorescence microscopy in living cells due to sarcomeric epitope tagging. Therefore, this genetic system permits the rapid selection of a relatively pure population of developing cardiomyocytes from a heterogeneous population of differentiating ES cells, simultaneously allowing monitoring of early myofibrillogenesis in the selected myocytes
Resumo:
Non-invasive ambulatory blood pressure monitoring has proved to be very useful in evaluating hypertensive patients. However, most previous studies were performed in specialised centres. Here the results of two trials are presented in which private physicians used ambulatory BP monitoring to assess the efficacy of antihypertensive drugs. The results were very similar to those observed previously in specialised clinics. In the individual patient, the level of ambulatory recorded pressure could not be predicted based on BP readings taken at the doctor's office. Also, the BP response to antihypertensive therapy was more reproducible when evaluated by ambulatory BP monitoring than by the doctor. Thus, the use of noninvasive ambulatory BP monitoring is also very appropriate in everyday practice for the management of hypertensive patients.
Resumo:
In this study we propose an evaluation of the angular effects altering the spectral response of the land-cover over multi-angle remote sensing image acquisitions. The shift in the statistical distribution of the pixels observed in an in-track sequence of WorldView-2 images is analyzed by means of a kernel-based measure of distance between probability distributions. Afterwards, the portability of supervised classifiers across the sequence is investigated by looking at the evolution of the classification accuracy with respect to the changing observation angle. In this context, the efficiency of various physically and statistically based preprocessing methods in obtaining angle-invariant data spaces is compared and possible synergies are discussed.
Resumo:
Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4-L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4 degrees between readings at any individual position, and as high as 6 degrees between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs.
Resumo:
OBJECTIVE: To examine the compliance to medication among newly diagnosed hypertensive patients screened from the general population of the Seychelles, a rapidly developing country. METHODS: Among the 1067 participants to a population-based survey for cardiovascular risk factors, hypertension was discovered in 50 (previously unaware of having hypertension and having blood pressure > or = 160/95 mmHg over 3 visits). These 50 patients were placed on a daily one-pill regimen of medication (bendrofluazide, atenolol, or a combination of hydrochlorothiazide and atenolol) and compliance to the regimen was assessed over 12 months using electronic pill containers. Satisfactory compliance was defined as taking the medication on 6 or 7 days a week on average (which corresponds to a mean compliance level of > or = 86%). FINDINGS: In the first month, fewer than half (46%) of the new hypertension patients achieved satisfactory compliance, and only about one-quarter (26%) achieved this level by the twelfth month. Compliance was better among the 23 participants who regularly attended medical follow-up, with nearly three-quarters of these patients (74%) achieving satisfactory compliance during the first month and over one-half (55%) by the twelfth month. There was a direct association between mean 12-month compliance level and having a highly skilled occupation; having good health awareness; and regularly attending medical appointments. In contrast, there was an inverse relationship between mean compliance level and heavy drinking. CONCLUSION: The low proportion of people selected from the general population who were capable of sustaining satisfactory compliance to antihypertension medication may correspond to the maximum effectiveness of medication interventions based on a screening and treatment strategy in the general population. The results stress the need for both high-risk and population approaches to improve hypertension control.
Resumo:
The objective of this research was to determine whether the level of parental monitoring is associated with substance use among adolescents in Switzerland, and to assess whether this effect remains when these adolescents have consuming peers. For this purpose, we used a nationally representative sample from the Swiss participation in the 2007 European School Project on Alcohol and Other Drugs survey, which included 7,611 adolescents in public schools (8th-10th grades). Four levels of parental control were created and four substances (tobacco, alcohol, cannabis, and ecstasy) were analyzed. All significant variables at the bivariate level were included in the multivariate analysis. Most adolescents had a high level of parental monitoring and that was associated with younger age, females, high socioeconomic status, intact family structure, and satisfactory relationships with mother, father, and peers. Overall, substance use decreased as parental monitoring increased and high parental monitoring decreased as having consuming peers increased. Results remained essentially the same when the variable "having consuming peers" was added to the analysis. Conclusion: parental monitoring is associated to positive effects on adolescent substance use with a reduction of consumption and a lower probability of having consuming peers, which seems to protect adolescents against potentially negative peer influence. Encouraging parents to monitor their adolescents' activities and friendships by establishing rules about what is allowed or not is a way to limit the negative influence of consuming peers on adolescent substance use.
Resumo:
Patients admitted to the neurocritical care unit (NCCU) often have serious conditions that can be associated with high morbidity and mortality. Pharmacologic agents or neuroprotectants have disappointed in the clinical environment. Current NCCU management therefore is directed toward identification, prevention, and treatment of secondary cerebral insults that evolve over time and are known to aggravate outcome. This strategy is based on a variety of monitoring techniques including use of intraparenchymal monitors. This article reviews parenchymal brain oxygen monitors, including the available technologies, practical aspects of use, the physiologic rationale behind their use, and patient management based on brain oxygen.
Resumo:
Monitoring of a medical condition is the periodic measurement of one or several physiological or biological variables to detect a signal regarding its clinical progression or its response to treatment. We distinguish different medical situations between diagnostic, clinical and therapeutic process to apply monitoring. Many clinical, variables can be used for monitoring, once their intrinsic properties (normal range, critical difference, kinetics, reactivity) and external validity (pathophysiological importance, predictive power for clinical outcomes) are established. A formal conceptualization of monitoring is being developed and should support the rational development of monitoring strategies and their validation through appropriate clinical trials.
Resumo:
Aims: Plasma concentrations of imatinib differ largely between patients despite same dosage, owing to large inter-individual variability in pharmacokinetic (PK) parameters. As the drug concentration at the end of the dosage interval (Cmin) correlates with treatment response and tolerability, monitoring of Cmin is suggested for therapeutic drug monitoring (TDM) of imatinib. Due to logistic difficulties, random sampling during the dosage interval is however often performed in clinical practice, thus rendering the respective results not informative regarding Cmin values.Objectives: (I) To extrapolate randomly measured imatinib concentrations to more informative Cmin using classical Bayesian forecasting. (II) To extend the classical Bayesian method to account for correlation between PK parameters. (III) To evaluate the predictive performance of both methods.Methods: 31 paired blood samples (random and trough levels) were obtained from 19 cancer patients under imatinib. Two Bayesian maximum a posteriori (MAP) methods were implemented: (A) a classical method ignoring correlation between PK parameters, and (B) an extended one accounting for correlation. Both methods were applied to estimate individual PK parameters, conditional on random observations and covariate-adjusted priors from a population PK model. The PK parameter estimates were used to calculate trough levels. Relative prediction errors (PE) were analyzed to evaluate accuracy (one-sample t-test) and to compare precision between the methods (F-test to compare variances).Results: Both Bayesian MAP methods allowed non-biased predictions of individual Cmin compared to observations: (A) - 7% mean PE (CI95% - 18 to 4 %, p = 0.15) and (B) - 4% mean PE (CI95% - 18 to 10 %, p = 0.69). Relative standard deviations of actual observations from predictions were 22% (A) and 30% (B), i.e. comparable to the intraindividual variability reported. Precision was not improved by taking into account correlation between PK parameters (p = 0.22).Conclusion: Clinical interpretation of randomly measured imatinib concentrations can be assisted by Bayesian extrapolation to maximum likelihood Cmin. Classical Bayesian estimation can be applied for TDM without the need to include correlation between PK parameters. Both methods could be adapted in the future to evaluate other individual pharmacokinetic measures correlated to clinical outcomes, such as area under the curve(AUC).
Resumo:
OBJECTIVES: To determine the prevalence, predictors, and clinical significance of electrographic seizures (ESz) and other continuous electroencephalographic monitoring findings in critically ill patients with central nervous system infections. DESIGN: Retrospective cohort study. SETTING: Eighteen-bed neurocritical care unit. PATIENTS: We identified 42 consecutive patients with primary central nervous system infection (viral, 27 patients [64%]; bacterial, 8 patients [18%]; and fungal or parasitic, 7 patients [17%]) who underwent continuous electroencephalographic monitoring between January 1, 1996, and February 28, 2007. MAIN OUTCOME MEASURES: Presence of ESz or periodic epileptiform discharges (PEDs). RESULTS: Electrographic seizures were recorded in 14 patients (33%), and PEDs were recorded in 17 patients (40%). Twenty patients (48%) had either PEDs or ESz. Of the 14 patients with ESz, only 5 (36%) had a clinical correlate. Periodic epileptiform discharges (odds ratio=13.4; P=.001) and viral cause (odds ratio=13.0; P=.02) were independently associated with ESz. Both ESz (odds ratio=5.9; P=.02) and PEDs (odds ratio=6.1; P=.01) were independently associated with poor outcome at discharge (severe disability, vegetative state, or death). CONCLUSIONS: In patients with central nervous system infections undergoing continuous electroencephalographic monitoring, ESz and/or PEDs were frequent, occurring in 48% of our cohort. More than half of the ESz had no clinical correlate. Both ESz and PEDs were independently associated with poor outcome. Additional studies are needed to determine whether prevention or treatment of these electrographic findings improves outcome.