305 resultados para Body marks
Resumo:
BACKGROUND: Obesity is strongly associated with major depressive disorder (MDD) and various other diseases. Genome-wide association studies have identified multiple risk loci robustly associated with body mass index (BMI). In this study, we aimed to investigate whether a genetic risk score (GRS) combining multiple BMI risk loci might have utility in prediction of obesity in patients with MDD. METHODS: Linear and logistic regression models were conducted to predict BMI and obesity, respectively, in three independent large case-control studies of major depression (Radiant, GSK-Munich, PsyCoLaus). The analyses were first performed in the whole sample and then separately in depressed cases and controls. An unweighted GRS was calculated by summation of the number of risk alleles. A weighted GRS was calculated as the sum of risk alleles at each locus multiplied by their effect sizes. Receiver operating characteristic (ROC) analysis was used to compare the discriminatory ability of predictors of obesity. RESULTS: In the discovery phase, a total of 2,521 participants (1,895 depressed patients and 626 controls) were included from the Radiant study. Both unweighted and weighted GRS were highly associated with BMI (P <0.001) but explained only a modest amount of variance. Adding 'traditional' risk factors to GRS significantly improved the predictive ability with the area under the curve (AUC) in the ROC analysis, increasing from 0.58 to 0.66 (95% CI, 0.62-0.68; χ(2) = 27.68; P <0.0001). Although there was no formal evidence of interaction between depression status and GRS, there was further improvement in AUC in the ROC analysis when depression status was added to the model (AUC = 0.71; 95% CI, 0.68-0.73; χ(2) = 28.64; P <0.0001). We further found that the GRS accounted for more variance of BMI in depressed patients than in healthy controls. Again, GRS discriminated obesity better in depressed patients compared to healthy controls. We later replicated these analyses in two independent samples (GSK-Munich and PsyCoLaus) and found similar results. CONCLUSIONS: A GRS proved to be a highly significant predictor of obesity in people with MDD but accounted for only modest amount of variance. Nevertheless, as more risk loci are identified, combining a GRS approach with information on non-genetic risk factors could become a useful strategy in identifying MDD patients at higher risk of developing obesity.
Resumo:
We tested for interactions between body mass index (BMI) and common genetic variants affecting serum urate levels, genome-wide, in up to 42569 participants. Both stratified genome-wide association (GWAS) analyses, in lean, overweight and obese individuals, and regression-type analyses in a non BMI-stratified overall sample were performed. The former did not uncover any novel locus with a major main effect, but supported modulation of effects for some known and potentially new urate loci. The latter highlighted a SNP at RBFOX3 reaching genome-wide significant level (effect size 0.014, 95% CI 0.008-0.02, Pinter= 2.6 x 10-8). Two top loci in interaction term analyses, RBFOX3 and ERO1LB-EDARADD, also displayed suggestive differences in main effect size between the lean and obese strata. All top ranking loci for urate effect differences between BMI categories were novel and most had small magnitude but opposite direction effects between strata. They include the locus RBMS1-TANK (men, Pdifflean-overweight= 4.7 x 10-8), a region that has been associated with several obesity related traits, and TSPYL5 (men, Pdifflean-overweight= 9.1 x 10-8), regulating adipocytes-produced estradiol. The top-ranking known urate loci was ABCG2, the strongest known gout risk locus, with an effect halved in obese compared to lean men (Pdifflean-obese= 2 x 10-4). Finally, pathway analysis suggested a role for N-glycan biosynthesis as a prominent urate-associated pathway in the lean stratum. These results illustrate a potentially powerful way to monitor changes occurring in obesogenic environment.
Resumo:
La problématique des marquages corporels en tant que pratiques ancestrales s'insèrent dans des formes contemporaines d'inscription corporelle. Nous nous sommes permis d'essayer de savoir s'il s'agissait toujours d'une expression d'un malaise psychologique important ? Quelles peuvent en être les conséquences ? Pourquoi marquer le corps ? La mise en oeuvre de ce travail s'est articulée en deux phases, au départ, nous avons opéré par une pré-enquête d'envergure qui a regroupé 200 adolescents (10 filles et 190 garçons). Ensuite et dans un deuxième temps nous avons interrogé dix adolescents qui se marquent la peau dont trois garçons, âgés de quinze à dix-neuf ans. Grâce à une « tri approche » : Entretien clinique, tests du Rorschach et du TAT. Les résultats auxquels nous sommes parvenus peuvent être résumés comme suit : ces pratiques expriment une souffrance qui peine à trouver une voie d'expression symbolique autre que le corps, l'angoisse et la relation d'objet du type anaclitique, l'organisation défensive renseigneraient essentiellement sur des défenses narcissiques, centrées notamment autour du clivage et le retournement sur soi, une identité fragile marquée par une image du corps et représentation de soi fragiles et un sur (dés) investissement des limites. Il s'agit d'une emprise sur le corps et sur les marques mêmes, permettant de retrouver l'objet et le recréer. À partir des principaux résultats obtenus, nous envisageons de travailler, en filigrane sur les spécificités des types de marquages corporels existant en Algérie. En effet si le présent travail s'est étayé sur une analyse prônant la globalité, un comparatif entre les types de marquages, de même, l'établissement d'un lien entre la symbolique de certaines pratiques et les soubassements psychodynamiques qui l'entourent, serait d'un apport considérable dans la compréhension du fait étudié dans ses moindres « recoins ». -- The problem of the physical markings as ancestral practices fit into contemporary forms of physical registration. We allowed to try to know if it was always about an expression of an important psychological illness? What can be the consequences? Why to mark the body? The application of this work articulated in two phases, at first, we operated by a large-scale pre- inquiry which grouped together 200 teenagers (10 girls and 190 boys). Then and in the second time we interrogated ten teenagers who mark the skin among which three boys, from fifteen to nineteen years old. Thanks to one « sorting approaches »: clinical Interview, tests of Rorschach and TAT. The results which we reached can be summarized as follows: these practices express a suffering which has difficulty in finding a way of symbolic expression other one than the body, the fear and the relation of object of the type anaclitique, the defensive organization would inform essentially about narcissistic defences, centred notably around the cleavage and the reversal on one, a fragile identity marked by an image of the body and the representation of one fragile and one on investment of the limits. It is about an influence on the body and on the marks, allowing to find the object and to recreate it. From the main obtained results, we intend to work, between the lines on the specificities of the types of physical markings existing in Algeria. Indeed if the present work supported on an analysis lauding the global nature, a comparative degree between the types of markings, also, the establishment of a link between the symbolism of certain practices and the bases psychodynamiques who surround him, would be of a considerable contribution in the understanding of the fact studied in its slightest « hidden recesses ».
Resumo:
Indoleamine 2,3-dioxygenase 1 (IDO1) is an immunosuppressive molecule expressed in some subsets of normal and neoplastic cells. Mature human dendritic cells (DCs) have been shown to express IDO1, but little is known about its expression and function during DC differentiation from bone marrow hematopoietic stem/progenitor cells (HSPCs). Here, we show that during in vitro differentiation along the myeloid DC lineage, CD34(+) HSPCs acquire IDO1 expression, which acts in a tolerogenic manner by inducing a population of fully functional CD4(+)CD25(+) FOXP3(+) T-regulatory cells. Phenotypically, CD1a(+)CD14(-) HPSC-derived DCs expressed IDO1, langerin, CD11b, and CD1c. Cell-sorting experiments demonstrated that IDO1 expression is found in a subset of CD1a(+)CD14(-)langerin(+) cells, expressing CD103, which is capable of inducing T-regulatory cells in an IDO1-dependent manner. In conclusion, DC differentiation from CD34(+) HSPCs results in the expression of a functionally active IDO1 protein in CD1a(+)langerin(+), CD103-expressing DCs. These data point toward IDO1 expression as part of a tolerogenic signature during DC development.
Resumo:
OBJECTIVE: This study investigated the effectiveness of stereotactic body radiotherapy with helical TomoTherapy (T-SBRT) for treating medically inoperable primary and second-primary early stage non-small-cell lung neoplasm (SPLN) and evaluated whether the movement of organizing pneumonia (OP) within the irradiation field (IF) can be detected via analysis of radiological changes. METHODS: Patients (n = 16) treated for 1 year (2011-12) at our hospital by T-SBRT at a total dose of 60 Gy in five fractions were examined retrospectively. Outcome and toxicity were recorded and were separately described for SPLN. CT scans were reviewed by a single radiologist. RESULTS: Of the 16 patients, 5 (31.3%) had primary lung malignancies, 10 (62.5%) had SPLN, and 1 case (6.3%) had isolated mediastinal metastasis of lung neoplasm. Pathological evidence was obtained for 72.2% of all lesions. The median radiological follow-up was 11 months (10.5 months for SPLN). For all cases, the 6- and 12-month survival rates were 100% and 77.7% (100% and 71.4%, respectively, for SPLN), and the 6- and 12-month locoregional control rates were 100% in all cases. 2 (12.5%) of 16 patients developed grade 3 late transient radiation pneumonitis following steroid therapy and 1 (6.3%) presented asymptomatic infiltrates comparable to OP opacities. CONCLUSION: T-SBRT seems to be safe and effective. ADVANCES IN KNOWLEDGE: Mild OP is likely associated with radiation-induced anomalies in the IF, identification of migrating opacities can help discern relapse of radiation-induced opacities.
Resumo:
BACKGROUND: Visceral obesity (VO) increases technical difficulty in laparoscopic surgery. The body mass index (BMI) does not always correlate to intra-abdominal fat distribution. Our hypothesis was that simple anthropometric measures that reflect VO, could predict technical difficulty in laparoscopic colorectal surgery, as reflected by the operative time, more accurately than the BMI. METHODS: Charts of all consecutive patients who underwent laparoscopic left colon resection in our institution between 2007 and 2010 were reviewed retrospectively. On a preoperative CT scan, anthropometric measures were taken on an axial plane at the L4-L5 level. Demographic, operative and anthropometric CT measures were correlated with the operative time. Logistic regression analysis was performed to assess the value of anthropometric CT measures or BMI to predict the duration of the colectomy. RESULTS: 121 patients with elective left colon resection for benign (56%) or malignant disease (44%) were included. There were 74 sigmoid resections (61%), 21 left hemicolectomies (17%) and 26 low anterior resections (22%). A longer sagittal abdominal diameter (≥24.8 cm) was significantly associated with longer corrected operative time (248 vs. 228 min, p = 0.043). In multivariate analysis, greater sagittal abdominal diameter, sagittal internal diameter and abdominal perimeter were significantly associated with longer operative time. No significant association was found for the BMI neither in univariate nor in multivariate analysis. CONCLUSIONS: This study suggests that simple linear measures taken on a CT scan, such as sagittal abdominal diameter, sagittal internal diameter and abdominal perimeter, may predict longer operative time in laparoscopic left colonic resections more accurately than BMI.
Resumo:
BACKGROUND: Magnetic resonance imaging (MRI) of patients with conventional implantable cardioverter-defibrillators (ICD) is contraindicated. OBJECTIVES: This multicenter, randomized trial evaluated safety and efficacy of a novel ICD system specially designed for full-body MRI without restrictions on heart rate or pacing dependency. The primary safety objective was >90% freedom from MRI-related events composite endpoint within 30 days post-MRI. The primary efficacy endpoints were ventricular pacing capture threshold and ventricular sensing amplitude. METHODS: Subjects received either a single- or dual-chamber ICD. In a 2:1 randomization, subjects either underwent MRI at 1.5-T of the chest, cervical, and head regions to maximize radiofrequency exposure up to 2 W/kg specific absorption rate and gradient field exposure to 200 T/m/s per axis (MRI group, n = 175), or they underwent a 1-h waiting period without MRI (control group, n = 88). A subset of MRI patients underwent ventricular fibrillation induction testing post-MRI to characterize defibrillation function. RESULTS: In 42 centers, 275 patients were enrolled (76% male, age 60.4 ± 13.8 years). The safety endpoint was met with 100% freedom from the composite endpoint (p < 0.0001). Both efficacy endpoints were met with minimal differences in the proportion of MRI and control patients who demonstrated a ≤0.5 V increase in ventricular pacing capture threshold (100% MRI vs. 98.8% control, noninferiority p < 0.0001) or a ≤50% decrease in R-wave amplitude (99.3% MRI vs. 98.8% control, noninferiority p = 0.0001). A total of 34 ventricular tachyarrhythmia/ventricular fibrillation episodes (20 induced; 14 spontaneous) occurred in 24 subjects post-MRI, with no observed effect on sensing, detection, or treatment. CONCLUSIONS: This is the first randomized clinical study of an ICD system designed for full-body MRI at 1.5-T. These data support that the system is safe and the MRI scan does not adversely affect electrical performance or efficacy. (Confirmatory Clinical Trial of the Evera MRI System for Conditionally-Safe MRI Access; NCT02117414).
Resumo:
BACKGROUND AND OBJECTIVES: Obstructive sleep apnea is associated with significantly increased cardiovascular morbidity and mortality. Fluid overload may promote obstructive sleep apnea in patients with ESRD through an overnight fluid shift from the legs to the neck soft tissues. Body fluid shift and severity of obstructive sleep apnea before and after hemodialysis were compared in patients with ESRD. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Seventeen patients with hemodialysis and moderate to severe obstructive sleep apnea were included. Polysomnographies were performed the night before and after hemodialysis to assess obstructive sleep apnea, and bioimpedance was used to measure fluid overload and leg fluid volume. RESULTS: The mean overnight rostral fluid shift was 1.27±0.41 L prehemodialysis; it correlated positively with fluid overload volume (r=0.39; P=0.02) and was significantly lower posthemodialysis (0.78±0.38 L; P<0.001). There was no significant difference in the mean obstructive apnea-hypopnea index before and after hemodialysis (46.8±22.0 versus 42.1±18.6 per hour; P=0.21), but obstructive apnea-hypopnea index was significantly lower posthemodialysis (-10.1±10.8 per hour) in the group of 12 patients, with a concomitant reduction of fluid overload compared with participants without change in fluid overload (obstructive apnea-hypopnea index +8.2±16.1 per hour; P<0.01). A lower fluid overload after hemodialysis was significantly correlated (r=0.49; P=0.04) with a lower obstructive apnea-hypopnea index. Fluid overload-assessed by bioimpedance-was the best predictor of the change in obstructive apnea-hypopnea index observed after hemodialysis (standardized r=-0.68; P=0.01) in multivariate regression analysis. CONCLUSIONS: Fluid overload influences overnight rostral fluid shift and obstructive sleep apnea severity in patients with ESRD undergoing intermittent hemodialysis. Although no benefit of hemodialysis on obstructive sleep apnea severity was observed in the whole group, the change in obstructive apnea-hypopnea index was significantly correlated with the change in fluid overload after hemodialysis. Moreover, the subgroup with lower fluid overload posthemodialysis showed a significantly lower obstructive sleep apnea severity, which provides a strong incentive to further study whether optimizing fluid status in patients with obstructive sleep apnea and ESRD will improve the obstructive apnea-hypopnea index.
Resumo:
Au sein de la population générale, de plus en plus de personnes arborent des piercings, en particulier parmi les jeunes adultes. Hormis les réactions inflammatoires et les infections locales, les complications liées à ces piercings sont méconnues. Les personnes ne sont en général pas informées des risques avant de réaliser un piercing et leurs antécédents, traitements médicamenteux ou comorbidités éventuelles, sont largement négligés par les personnes qui réalisent le geste. Les complications sont le plus souvent locales et bénignes, mais des complications sérieuses et parfois mortelles ont été décrites dans la littérature. Cet article propose une revue des problématiques possibles auxquelles pourrait être confronté un médecin de premier recours, face à un patient qui souhaiterait réaliser un piercing ou présenterait des complications suite à la mise en place d'un tel dispositif. The trend of body piercing has grown in popularity in the past decade within the general population and especially among young adults. Complications of body piercing include local inflammation and infections, but severe complications are also possible and largely underestimated. People are usually not aware of the risks before making a piercing, and their medical history, medication and comorbidities are largely neglected by the people who realise the piercing. This article presents a review of the complications that a primary care physician may observe, for a patient who wishes to make a piercing, or presents complications due to the implementation of such a device.