311 resultados para mapping technique
Resumo:
Between 1995 and 2005, the number of aortic aneurysms treated annually using endovascular techniques (EVAR) increased from 0 to 50, including all aortic stages. Our organization includes a large team of surgeons, a stock of three complete families of endoprostheses (straight, conical and bifurcated), a mobile trolley with accessories (arterial introducer/introducer sheath, guide wire, catheters, balloons, etc.) and an appliance on wheels for intravascular ultrasound examination (IVUS). This appliance, together with a mobile fluoroscopy device (c-arm), allows endovascular aneurysms analysis of every operating room in our institution, usually without angiography or the use of contrast medium. In general, we are therefore not depending on substantial preoperative imaging in order to identify candidates for endovascular aneurysms repair and can treat abdominal and thoracic aortic ruptures without delay. For endovascular aortic aneurysms repair we distinguish between process steps on the one hand (determining indications, imaging of the access vessels, measurement using IVUS and road mapping via fluoroscopy, selection of implant, implant insertion, positioning, setting the implant, determining success, reconstruction of the access vessel and follow-up) and the level of competence on the other (assistant, senior and directing physicians). Our ultrasound supported technique for endovascular aneurysms repair has been successfully brought to other hospitals using an IVUS transporter and telementoring.
Resumo:
Prospective comparative evaluation of patent V blue, fluorescein and (99m)TC-nanocolloids for intraoperative sentinel lymph node (SLN) mapping during surgery for non-small cell lung cancer (NSCLC). Ten patients with peripherally localised clinical stage I NSCLC underwent thoracotomy and peritumoral subpleural injection of 2 ml of patent V blue dye, 1 ml of 10% fluorescein and 1ml of (99m)Tc-nanocolloids (0.4 mCi). The migration and spatial distribution pattern of the tracers was assessed by direct visualisation (patent V blue), visualisation of fluorescence signalling by a lamp of Wood (fluorescein) and radioactivity counting with a hand held gamma-probe ((99m)Tc-nanocolloids). Lymph nodes at interlobar (ATS 11), hilar (ATS 10) and mediastinal (right ATS 2,4,7; left ATS 5,6,7) levels were systematically assessed every 10 min up to 60 min after injection, followed by lobectomy and formal lymph node dissection. Successful migration from the peritumoral area to the mediastinum was observed for all three tracers up to 60 min after injection. The interlobar lympho-fatty tissue (station ATS 11) revealed an early and preferential accumulation of all three tracers for all tumours assessed and irrespective of the tumour localisation. However, no preferential accumulation in one or two distinct lymph nodes was observed up to 60 min after injection for all three tracers assessed. Intraoperative SLN mapping revealed successful migration of the tracers from the site of peritumoral injection to the mediastinum, but in a diffuse pattern without preferential accumulation in sentinel lymph nodes.
Resumo:
The objective of this study was to assess the efficiency of spiral CT (SCT) aortography for diagnosing acute aortic lesions in blunt thoracic trauma patients. Between October 1992 and June 1997, 487 SCT scans of the chest were performed on blunt thoracic trauma patients. To assess aortic injury, the following SCT criteria were considered: hemomediastinum, peri-aortic hematoma, irregular aspect of the aortic wall, aortic pseudodiverticulum, intimal flap and traumatic dissection. Aortic injury was diagnosed on 14 SCT examinations (2.9 %), five of the patients having had an additional digital aortography that confirmed the aortic trauma. Twelve subjects underwent surgical repair of the thoracic aorta, which in all but one case confirmed the aortic injury. Two patients died before surgery from severe brain lesions. The aortic blunt lesions were confirmed at autopsy. According to the follow-up of the other 473 patients, we are aware of no false-negative SCT examination. Our limited series shows a sensitivity of 100 % and specificity of 99.8 % of SCT aortography in the diagnosis of aortic injury. It is concluded that SCT aortagraphy is an accurate diagnostic method for the assessment of aortic injury in blunt thoracic trauma patients.
Resumo:
The paper deals with the development and application of the methodology for automatic mapping of pollution/contamination data. General Regression Neural Network (GRNN) is considered in detail and is proposed as an efficient tool to solve this problem. The automatic tuning of isotropic and an anisotropic GRNN model using cross-validation procedure is presented. Results are compared with k-nearest-neighbours interpolation algorithm using independent validation data set. Quality of mapping is controlled by the analysis of raw data and the residuals using variography. Maps of probabilities of exceeding a given decision level and ?thick? isoline visualization of the uncertainties are presented as examples of decision-oriented mapping. Real case study is based on mapping of radioactively contaminated territories.
Resumo:
Metallic foreign bodies are rarely found in the maxillary sinus, and usually they have a dental origin.Potential complications related to foreign bodies include recurrent sinusitis, rhinolith formation, cutaneous fistula,chemical poisoning, facial neuralgic pain and even malignancies.Two main surgical approaches are currently used for the removal of foreign bodies in the maxillary sinus: the bone flap and the endoscopic sinus techniques. We are reporting two unusual cases of large high-velocity foreign bodies removed by a modified maxillary lateral antrotomy,with free bone flap repositioning and fixation with a titanium miniplate.
Resumo:
β-blockers and β-agonists are primarily used to treat cardiovascular diseases. Inter-individual variability in response to both drug classes is well recognized, yet the identity and relative contribution of the genetic players involved are poorly understood. This work is the first genome-wide association study (GWAS) addressing the values and susceptibility of cardiovascular-related traits to a selective β(1)-blocker, Atenolol (ate), and a β-agonist, Isoproterenol (iso). The phenotypic dataset consisted of 27 highly heritable traits, each measured across 22 inbred mouse strains and four pharmacological conditions. The genotypic panel comprised 79922 informative SNPs of the mouse HapMap resource. Associations were mapped by Efficient Mixed Model Association (EMMA), a method that corrects for the population structure and genetic relatedness of the various strains. A total of 205 separate genome-wide scans were analyzed. The most significant hits include three candidate loci related to cardiac and body weight, three loci for electrocardiographic (ECG) values, two loci for the susceptibility of atrial weight index to iso, four loci for the susceptibility of systolic blood pressure (SBP) to perturbations of the β-adrenergic system, and one locus for the responsiveness of QTc (p<10(-8)). An additional 60 loci were suggestive for one or the other of the 27 traits, while 46 others were suggestive for one or the other drug effects (p<10(-6)). Most hits tagged unexpected regions, yet at least two loci for the susceptibility of SBP to β-adrenergic drugs pointed at members of the hypothalamic-pituitary-thyroid axis. Loci for cardiac-related traits were preferentially enriched in genes expressed in the heart, while 23% of the testable loci were replicated with datasets of the Mouse Phenome Database (MPD). Altogether these data and validation tests indicate that the mapped loci are relevant to the traits and responses studied.
Resumo:
Controversy exists about the best method to achieve bone fusion in four-corner arthrodesis. Thirty-five patients who underwent this procedure by our technique were included in the study. Surgical indications were stage II-III SLAC wrist, stage II SNAC wrist and severe traumatic midcarpal joint injury. Mean follow-up was 4.6 years. Mean active flexion and extension were 34 degrees and 30 degrees respectively; grip strength recovery was 79%. Radiological consolidation was achieved in all cases. The mean DASH score was 23 and the postoperative pain improvement by visual analogue scale was statistically significant. Return to work was possible at 4 months for the average patient. Complications were a capitate fracture in one patient and the need for hardware removal in four cases. Four-corner bone wrist arthrodesis by dorsal rectangular plating achieves an acceptable preservation of range of motion with good pain relief, an excellent consolidation rate and minimal complications.
Resumo:
Electrical Impedance Tomography (EIT) is an imaging method which enables a volume conductivity map of a subject to be produced from multiple impedance measurements. It has the potential to become a portable non-invasive imaging technique of particular use in imaging brain function. Accurate numerical forward models may be used to improve image reconstruction but, until now, have employed an assumption of isotropic tissue conductivity. This may be expected to introduce inaccuracy, as body tissues, especially those such as white matter and the skull in head imaging, are highly anisotropic. The purpose of this study was, for the first time, to develop a method for incorporating anisotropy in a forward numerical model for EIT of the head and assess the resulting improvement in image quality in the case of linear reconstruction of one example of the human head. A realistic Finite Element Model (FEM) of an adult human head with segments for the scalp, skull, CSF, and brain was produced from a structural MRI. Anisotropy of the brain was estimated from a diffusion tensor-MRI of the same subject and anisotropy of the skull was approximated from the structural information. A method for incorporation of anisotropy in the forward model and its use in image reconstruction was produced. The improvement in reconstructed image quality was assessed in computer simulation by producing forward data, and then linear reconstruction using a sensitivity matrix approach. The mean boundary data difference between anisotropic and isotropic forward models for a reference conductivity was 50%. Use of the correct anisotropic FEM in image reconstruction, as opposed to an isotropic one, corrected an error of 24 mm in imaging a 10% conductivity decrease located in the hippocampus, improved localisation for conductivity changes deep in the brain and due to epilepsy by 4-17 mm, and, overall, led to a substantial improvement on image quality. This suggests that incorporation of anisotropy in numerical models used for image reconstruction is likely to improve EIT image quality.
Resumo:
(Résumé de l'ouvrage) Qu'est-ce qui justifie l'emploi de rituels dans de nombreuses civilisations, anciennes ou contemporaines ? Sur quoi repose l'efficacité des rites ? Pour répondre à ces questions, ce livre propose une approche transdisciplinaire novatrice, qui rompt avec le cloisonnement en champs scientifiques étanches prévalant trop souvent dans l'exploration des pratiques rituelles. La réflexion autour des frontières et interactions entre les sphères socioculturelle, psychique et physiologique fait ressortir le caractère plastique et dynamique de celles-ci. Il s'agit notamment de souligner l'importance, dans de nombreuses cultures et à des épo-ques différentes, de techniques ou « orthopratiques » corporelles, psychologiques et sociales utilisées en vue de résultats pratiques spécifiques. Par ailleurs, les discours et les « représentations » propres aux systèmes institutionnels (science, médecine, philosophie, théologie) sur lesquels repose notre culture moderne se révèlent à même d'effectuer la « construction-réalisation » des objets mêmes qu'ils prétendent décrire. Ainsi, tant les « orthopratiques » appliquées, traitées dans la première partie du volume, que les pratiques émanant de nos systèmes institutionnels, traitées dans la seconde partie, tendent vers des objectifs transformationnels et opératoires. Alors que les unes opèrent dans un cadre magico-religieux, thérapeutique ou pédagogique, les autres se situent dans le contexte de la modernité. Mais elles se rejoignent en une dynamique dont les contribu-tions réunies ici viennent éclairer la nature et l'homme aux niveaux organique, psychique et historico-social. Ce qui revient, du même coup, à relancer l'interrogation philosophique qui porte sur la notion même de « réalité ».
Resumo:
Low energy x-ray fluorescence (LEXRF) detection was optimized for imaging cerebral glucose metabolism by mapping the fluorine LEXRF signal of 19 F in 19 FDG, trapped as intracellular 19 F-deoxyglucose-6-phosphate ( 19 FDG-6P) at 1μm spatial resolution from 3μm thick brain slices. 19 FDG metabolism was evaluated in brain structures closely resembling the general cerebral cytoarchitecture following formalin fixation of brain slices and their inclusion in an epon matrix. 2-dimensional distribution maps of 19 FDG-6P were placed in a cytoarchitectural and morphological context by simultaneous LEXRF mapping of N and O, and scanning transmission x-ray (STXM) imaging. A disproportionately high uptake and metabolism of glucose was found in neuropil relative to intracellular domains of the cell body of hypothalamic neurons, showing directly that neurons, like glial cells, also metabolize glucose. As 19 F-deoxyglucose-6P is structurally identical to 18 F-deoxyglucose-6P, LEXRF of subcellular 19 F provides a link to in vivo 18 FDG PET, forming a novel basis for understanding the physiological mechanisms underlying the 18 FDG PET image, and the contribution of neurons and glia to the PET signal.