342 resultados para image reconstruction
Resumo:
For radiotherapy treatment planning of retinoblastoma inchildhood, Computed Tomography (CT) represents thestandard method for tumor volume delineation, despitesome inherent limitations. CT scan is very useful inproviding information on physical density for dosecalculation and morphological volumetric information butpresents a low sensitivity in assessing the tumorviability. On the other hand, 3D ultrasound (US) allows ahigh accurate definition of the tumor volume thanks toits high spatial resolution but it is not currentlyintegrated in the treatment planning but used only fordiagnosis and follow-up. Our ultimate goal is anautomatic segmentation of gross tumor volume (GTV) in the3D US, the segmentation of the organs at risk (OAR) inthe CT and the registration of both. In this paper, wepresent some preliminary results in this direction. Wepresent 3D active contour-based segmentation of the eyeball and the lens in CT images; the presented approachincorporates the prior knowledge of the anatomy by usinga 3D geometrical eye model. The automated segmentationresults are validated by comparing with manualsegmentations. Then, for the fusion of 3D CT and USimages, we present two approaches: (i) landmark-basedtransformation, and (ii) object-based transformation thatmakes use of eye ball contour information on CT and USimages.
Resumo:
Partant de l'hypothèse qu'au cinéma, un plan travaillé à la manière d'un tableau engage non pas un arrêt du récit, mais un enrichissement de la logique narrative linéaire du film par une sémiotique tabulaire et des jeux de références intermédiales, cet article analyse le cas exemplaire et récurrent des plans qui reconstituent en « tableau vivant » La Cène de Léonard de Vinci. Christus (Giulio Antamoro, 1914-1916), Ben Hur, a tale of the Christ (Fred Niblo, 1925) ou Quo Vadis (Mervyn LeRoy, 1951) y sont explorés, ainsi que d'autres productions qui replacent la composition du Cenacolo à la fois en une « phase » et une « stase » dramatique et esthétique du récit christique. Des films tels que Viridiana (Luis Buñuel, 1961) sont aussi évoqués, qui font apparaître la composition comme une pause allégorique d'un récit contemporain, enrichi sur un plan énonciatif, symbolique et iconographique.
Resumo:
OBJECTIVES: To refine the classic definition of, and provide a working definition for, congenital high airway obstruction syndrome (CHAOS) and to discuss the various aspects of long-term airway reconstruction, including the range of laryngeal anomalies and the various techniques for reconstruction. DESIGN: Retrospective chart review. PATIENTS: Four children (age range, 2-8 years) with CHAOS who presented to a single tertiary care children's hospital for pediatric airway reconstruction between 1995 and 2000. CONCLUSIONS: To date, CHAOS remains poorly described in the otolaryngologic literature. We propose the following working definition for pediatric cases of CHAOS: any neonate who needs a surgical airway within 1 hour of birth owing to high upper airway (ie, glottic, subglottic, or upper tracheal) obstruction and who cannot be tracheally intubated other than through a persistent tracheoesophageal fistula. Therefore, CHAOS has 3 possible presentations: (1) complete laryngeal atresia without an esophageal fistula, (2) complete laryngeal atresia with a tracheoesophageal fistula, and (3) near-complete high upper airway obstruction. Management of the airway, particularly in regard to long-term reconstruction, in children with CHAOS is complex and challenging.
Resumo:
Biological integration of the tendon graft is a crucial prerequisite for successful ACL reconstruction. Histological studies showed that the human ACL remnants contain a cellular capacity for healing potential. The goal of this technical note is to describe an ACL reconstruction technique, using ACL remnants as a biological sleeve for the graft. In case of complete ACL rupture with a large remnant, the tibial tunnel was performed inside and through the ACL tibial stump by careful sequential drilling. Femoral tunnel placement was performed by an outside-in technique. The hamstring graft was kept attached to the tibia and routed through the ACL remnant to the femur. The aim of this technique is the preservation of the biological and mechanical properties of the ACL remnant. In order to preserve large remnants resulting in greater graft coverage, the best period to perform this reconstruction is during the first weeks after the injury.
Resumo:
Post-lobectomy bronchovascular fistula (BVF) associated with massive hemoptysis is a rare but life-threatening complication. Surgical options include completion pneumonectomy or BVF resection with end-to-end anastomosis of the airways and reconstruction of the pulmonary artery (PA) by interposition of an appropriate substitute. We report PA resection and successful reconstruction by interposition of an autologous reversed superficial femoral vein (SFV) segment for this purpose.
Resumo:
BACKGROUND: Laparoscopic enucleation for neuroendocrine pancreatic tumors has become a feasible technique, with a reported incidence of pancreatic fistula ranging from 13 to 29 %.1 (-) 3 This report describes the first successful case of laparoscopic pancreatic enucleation with resection of the main pancreatic duct followed by end-to-end anastomosis. METHODS: A 41-year-old woman was admitted to the authors' hospital for repeated syncope. Hypoglycemia also was noted. A contrast-enhanced computed tomography examination showed a highly enhanced tumor measuring 22 mm in diameter on the ventral side of the pancreatic body adjacent to the main pancreatic duct. The patient's blood insulin level was elevated, and her diagnosis was determined to be pancreatic insulinoma. Laparoscopic pancreatic enucleation was performed. Approximately 2 cm of the main pancreatic duct was segmentally resected, and a short stent (Silicone tube: Silastic, Dow Corning Corporation, Midland, MI) was inserted. The direct anastomosis of the main pancreatic duct was performed using four separate sutures with an absorbable monofilament (6-0 PDS). RESULTS: The operation time was 166 min, and the estimated blood loss was 100 mL. The postoperative course was uneventful, and the patient was discharged from hospital on postoperative day 7. The pathologic findings showed a well-differentiated insulinoma and a negative surgical margin. A computed tomography examination performed 1 month after the operation showed a successful anastomosis with a patent main pancreatic duct. CONCLUSIONS: Laparoscopic segmental resection of the main pancreatic duct and end-to-end anastomosis can be performed safely with the insertion of a short stent. This technique also can be used for a central pancreatectomy.
Resumo:
Remote sensing image processing is nowadays a mature research area. The techniques developed in the field allow many real-life applications with great societal value. For instance, urban monitoring, fire detection or flood prediction can have a great impact on economical and environmental issues. To attain such objectives, the remote sensing community has turned into a multidisciplinary field of science that embraces physics, signal theory, computer science, electronics, and communications. From a machine learning and signal/image processing point of view, all the applications are tackled under specific formalisms, such as classification and clustering, regression and function approximation, image coding, restoration and enhancement, source unmixing, data fusion or feature selection and extraction. This paper serves as a survey of methods and applications, and reviews the last methodological advances in remote sensing image processing.
Resumo:
La planification scanographique (3D) a démontré son utilité pour une reconstruction anatomique plus précise de la hanche (longueur du fémur, centre de rotation, offset, antéversion et rétroversion). Des études ont montré que lors de la planification 2D 50% seulement correspondaient à l'implant définitif du fémur alors que dans une autre étude ce taux s'élevait à 94% pour une planification 3D. Les erreurs étaient liées à l'agrandissement des radiographies. L'erreur sur la taille de la tige est liée à l'estimation inadéquate de la morphologie osseuse ainsi qu'à la densité osseuse. L'erreur de l'antéversion, augmentée par l'inclinaison du bassin, a pu être éliminée par la planification 3D et l'offset restauré dans 98%. Cette étude est basée sur une nouvelle technique de planification scanographique en trois dimensions pour une meilleure précision de la reconstruction de la hanche. Le but de cette étude est de comparer l'anatomie post-opératoire à celle préopératoire en comparant les tailles d'implant prévu lors de la planification 3D à celle réellement utilisée lors de l'opération afin de déterminer l'exactitude de la restauration anatomique avec étude des différents paramètres (centre de rotation, densité osseuse, L'offset fémoral, rotations des implants, longueur du membre) à l'aide du Logiciel HIP-PLAN (Symbios) avec évaluation de la reproductibilité de notre planification 3D dans une série prospective de 50 patients subissant une prothèse totale de hanche non cimentée primaire par voie antérieure. La planification pré-opératoire a été comparée à un CTscan postopératoire par fusion d'images. CONCLUSION ET PRESPECTIVE Les résultats obtenus sont les suivants : La taille de l'implant a été prédit correctement dans 100% des tiges, 94% des cupules et 88% des têtes (longueur). La différence entre le prévu et la longueur de la jambe postopératoire était de 0,3+2,3 mm. Les valeurs de décalage global, antéversion fémorale, inclinaison et antéversion de la cupule étaient 1,4 mm ± 3,1, 0,6 ± 3,3 0 -0,4 0 ± 5 et 6,9 ° ± 11,4, respectivement. Cette planification permet de prévoir la taille de l'implant précis. Position de la tige et de l'inclinaison de la cupule sont exactement reproductible. La planification scanographique préopératoire 3D permet une évaluation précise de l'anatomie individuelle des patients subissant une prothèse totale de hanche. La prédiction de la taille de l'implant est fiable et la précision du positionnement de la tige est excellente. Toutefois, aucun avantage n'est observée en termes d'orientation de la cupule par rapport aux études impliquant une planification 2D ou la navigation. De plus amples recherches comparant les différentes techniques de planification pré-opératoire à la navigation sont nécessaire.
Resumo:
PURPOSE OF REVIEW: The article reviews recent significant advances and current applications of the temporoparietal fascia flap (TPFF) in head and neck surgery. RECENT FINDINGS: The recent literature describes a wide span of new applications of the TPFF in many areas. Significant developments and refinements in the reconstruction of orbitomaxillary composite defects and orbital exenteration cavities are reported. The TPFF combined with alloplastic framework is gaining in importance in external ear reconstruction. Innovative prefabricated skin or soft-tissue grafts based on the TPFF are used to restore facial contour or in the reconstruction of complex facial defects. The free TPFF finds a role in laryngotracheal reconstruction as a vascular carrier to support cartilage grafts. SUMMARY: Owing to its reliability and unequalled structural properties, the TPFF still plays a central role in facial reconstruction. Future investigation will likely incorporate the free TPFF as a vascular carrier of bioengineered tissues, such as cartilage and mucosa, for various head and neck indications.