309 resultados para Inertial Measurement Unit
Resumo:
OBJECTIVE: Critically ill patients are at high risk of malnutrition. Insufficient nutritional support still remains a widespread problem despite guidelines. The aim of this study was to measure the clinical impact of a two-step interdisciplinary quality nutrition program. DESIGN: Prospective interventional study over three periods (A, baseline; B and C, intervention periods). SETTING: Mixed intensive care unit within a university hospital. PATIENTS: Five hundred seventy-two patients (age 59 ± 17 yrs) requiring >72 hrs of intensive care unit treatment. INTERVENTION: Two-step quality program: 1) bottom-up implementation of feeding guideline; and 2) additional presence of an intensive care unit dietitian. The nutrition protocol was based on the European guidelines. MEASUREMENTS AND MAIN RESULTS: Anthropometric data, intensive care unit severity scores, energy delivery, and cumulated energy balance (daily, day 7, and discharge), feeding route (enteral, parenteral, combined, none-oral), length of intensive care unit and hospital stay, and mortality were collected. Altogether 5800 intensive care unit days were analyzed. Patients in period A were healthier with lower Simplified Acute Physiologic Scale and proportion of "rapidly fatal" McCabe scores. Energy delivery and balance increased gradually: impact was particularly marked on cumulated energy deficit on day 7 which improved from -5870 kcal to -3950 kcal (p < .001). Feeding technique changed significantly with progressive increase of days with nutrition therapy (A: 59% days, B: 69%, C: 71%, p < .001), use of enteral nutrition increased from A to B (stable in C), and days on combined and parenteral nutrition increased progressively. Oral energy intakes were low (mean: 385 kcal*day, 6 kcal*kg*day ). Hospital mortality increased with severity of condition in periods B and C. CONCLUSION: A bottom-up protocol improved nutritional support. The presence of the intensive care unit dietitian provided significant additional progression, which were related to early introduction and route of feeding, and which achieved overall better early energy balance.
Resumo:
Ambulatory blood pressure monitoring (ABPM) has become indispensable for the diagnosis and control of hypertension. However, no consensus exists on how daytime and nighttime periods should be defined. OBJECTIVE: To compare daytime and nighttime blood pressure (BP) defined by an actigraph and by body position with BP resulting from arbitrary daytime and nighttime periods. PATIENTS AND METHOD: ABPM, sleeping periods and body position were recorded simultaneously using an actigraph (SenseWear Armband(®)) in patients referred for ABPM. BP results obtained with the actigraph (sleep and position) were compared to the results obtained with fixed daytime (7a.m.-10p.m.) and nighttime (10p.m.-7a.m.) periods. RESULTS: Data from 103 participants were available. More than half of them were taking antihypertensive drugs. Nocturnal BP was lower (systolic BP: 2.08±4.50mmHg; diastolic BP: 1.84±2.99mmHg, P<0.05) and dipping was more marked (systolic BP: 1.54±3.76%; diastolic BP: 2.27±3.48%, P<0.05) when nighttime was defined with the actigraph. Standing BP was higher (systolic BP 1.07±2.81mmHg; diastolic BP: 1.34±2.50mmHg) than daytime BP defined by a fixed period. CONCLUSION: Diurnal BP, nocturnal BP and dipping are influenced by the definition of daytime and nighttime periods. Studies evaluating the prognostic value of each method are needed to clarify which definition should be used.
Resumo:
THESIS ABSTRACT Garnets are one of the key metamorphic minerals used to study peak metamorphic conditions or crystallization ages. Equilibrium is typically assumed between the garnet and the matrix. This thesis attempts to understand garnet growth in the Zermatt-Saas Fee (ZSF) eclogites, and discusses consequences for Sm/Nd and Lu/Hf dating and the equilibrium assumption. All studied garnets from the ZSF eclogites are strongly zoned in Mn, Fe, Mg, and Ca. Methods based on chemical zoning patterns and on 3D spatial statistics indicate different growth mechanisms depending on the sample studied. Garnets from the Pfulwe area are grown in a system where surface kinetics likely dominated over intergranular diffusion kinetics. Garnets fram two other localities, Nuarsax and Lago di Cignana, seem to have grown in a system where intergranular diffusion kinetics were dominating over surface kinetics, at least during initial growth. Garnets reveal strong prograde REE+Y zoning. They contain narrow central peaks for Lu + Yb + Tm ± Er and at least one additional small peak towards the rim. The REE Sm + Eu + Gd + Tb ± Dy are depleted in the cores but show one prominent peak close to the rim. It is shown that these patterns cam be explained using a transient matrix diffusion model where REE uptake is limited by diffusion in the matrix surrounding the porphyroblast. The secondary peaks in the garnet profiles are interpreted to reflect thermally activated diffusion due to a temperature increase during prograde metamorphism. The model predicts anomalously low 176Lu/177Hf and 147Sm/144Nd ratios in garnets where growth rates are fast compared to diffusion of the REE, which decreases garnet isochron precisions. The sharp Lu zoning was further used to constrain maximum Lu volume diffusion rates in garnet. The modeled minimum pre-exponential diffusion coefficient which fits the measured central peak is in the order of Do = 5.7* 106 m2/s, taking an activation energy of 270 kJ/mol. The latter was chosen in agreement with experimentally determined values. This can be used to estimate a minimum closure temperature of around 630°C for the ZSF zone. Zoning of REE was combined with published Lu/Hf and Sm/Nd age information to redefine the prograde crystallization interval for Lago di Cignana UHP eclogites. Modeling revealed that a prograde growth interval in the order of 25 m.y. is needed to produce the measured spread in ages. RÉSUMÉ Le grenat est un minéral métamorphique clé pour déterminer les conditions du pic de métamorphisme ainsi que l'âge de cristallisation. L'équilibre entre le grenat et la matrice est requis. Cette étude a pour but de comprendre la croissance du grenat dans les éclogites de la zone de Zermatt-Saas Fee (ZSF) et d'examiner quelques conséquences sur les datations Sm/Nd et Lu/Hf. Tous les grenats des éclogites de ZSF étudiés sont fortement zonés en Mn, Fe, Mg et partiellement en Ca. Les différentes méthodes basées sur le modèle de zonation chimique ainsi que sur les statistiques de répartition spatiale en 3D indiquent un mécanisme de croissance différent en fonction de la localité d'échantillonnage. Les grenats provenant de la zone de Pfulwe ont probablement crû dans un système principalement dominé par la cinétique de surface au détriment de 1a cinétique de diffusion intergranulaire. Les grenats provenant de deux autres localités, Nuarsax et Lago di Cignana, semblent avoir cristallisé dans un système dominé par la diffusion intergranulaire, au moins durant les premiers stades de croissance. Les grenats montrent une forte zonation prograde en Terres Rares (REE) ainsi qu'en Y. Les profils présentent au coeur un pic étroit en Lu + Yb+ Tm ± Er et au moins un petit pic supplémentaire vers le bord. Les coeurs des grenats sont appauvris en Sm + Eu + Gd + Tb ± Dy, mais les bords sont marqués par un pic important de ces REE. Ces profils s'expliquent par un modèle de diffusion matricielle dans lequel l'apport en REE est limité par la diffusion dans la matrice environnant les porphyroblastes. Les pics secondaires en bordure de grain reflètent la diffusion activée par l'augmentation de la température lors du métamorphisme prograde. Ce modèle prédit des rapports 176Lu/177Hf et 147Sm/144Nd anormalement bas lorsque les taux de croissance sont plus rapides que la diffusion des REE, ce qui diminue la précision des isochrones impliquant le grenat. La zonation nette en Lu a permis de contraindre le maximum de diffusion volumique par une approche numérique. Le coefficient de diffusion minimum modélisé en adéquation avec les pics mesurés est de l'ordre de Do = 5.7*10-6 m2/s, en prenant une énergie d'activation ~270 kJ/mol déterminée expérimentalement. Ainsi, la température de clôture minimale est estimée aux alentours de 630°C pour la zone ZSF. Des nouvelles données de zonation de REE sont combinées aux âges obtenus avec les rapports Lu/Hf et Sm/Nd qui redéfissent l'intervalle de cristallisation prograde pour les éclogites UHP de Lago di Cignana. La modélisation permet d'attribuer au minimum un intervalle de croissance prograde de 25 Ma afin d'obtenir les âges préalablement mesurés. RESUME GRAND PUBLIC L'un des principaux buts du pétrologue .métamorphique est d'extraire des roches les informations sur l'évolution temporelle, thermique et barométrique qu'elles ont subi au cours de la formation d'une chaîne de montagne. Le grenat est l'un des minéraux clés dans une grande variété de roches métamorphiques. Il a fait l'objet de nombreuses études dans des terrains d'origines variées ou lors d'études expérimentales afin de comprendre ses domaines de stabilité, ses réactions et sa coexistence avec d'autres minéraux. Cela fait du grenat l'un des minéraux les plus attractifs pour la datation des roches. Cependant, lorsqu'on l'utilise pour la datation et/ou pour la géothermobarométrie, on suppose toujours que le grenat croît en équilibre avec les phases coexistantes de la matrice. Pourtant, la croissance d'un minéral est en général liée au processus de déséquilibre. Cette étude a pour but de comprendre comment croît le grenat dans les éclogites de Zermatt - Saas Fee et donc d'évaluer le degré de déséquilibre. Il s'agit aussi d'expliquer les différences d'âges obtenues grâce aux grenats dans les différentes localités de l'unité de Zermatt-Saas Fee. La principale question posée lors de l'étude des mécanismes de croissance du grenat est: Parmi les processus en jeu lors de la croissance du grenat (dissolution des anciens minéraux, transport des éléments vers le nouveau grenat, précipitation d'une nouvelle couche en surface du minéral), lequel est le plus lent et ainsi détermine le degré de déséquilibre? En effet, les grenats d'une des localités (Pfulwe) indiquent que le phénomène d'adhérence en surface est le plus lent, contrairement aux grenats des autres localités (Lago di Cignana, Nuarsax) dans lesquels ce sont les processus de transport qui sont les plus lents. Cela montre que les processus dominants sont variables, même dans des roches similaires de la même unité tectonique. Ceci implique que les processus doivent être déterminés individuellement pour chaque roche afin d'évaluer le degré de déséquilibre du grenat dans la roche. Tous les grenats analysés présentent au coeur une forte concentration de Terres Rares: Lu + Yb + Tm ± Er qui décroît vers le bord du grain. Inversement, les Terres Rares Sm + Eu + Gd + Tb ± Dy sont appauvries au coeur et se concentrent en bordure du grain. La modélisation révèle que ces profils sont-dus à des cinétiques lentes de transport des Terres Rares. De plus, les modèles prédisent des concentrations basses en éléments radiogéniques pères dans certaines roches, ce qui influence fortement sur la précision des âges obtenus par la méthode d'isochrone. Ceci signifie que les roches les plus adaptées pour les datations ne doivent contenir ni beaucoup de grenat ni de très gros cristaux, car dans ce cas, la compétition des éléments entre les cristaux limite à de faibles concentrations la quantité d'éléments pères dans chaque cristal.
Resumo:
We present the application of a real-time quantitative PCR assay, previously developed to measure relative telomere length in humans and mice, to two bird species, the zebra finch Taeniopygia guttata and the Alpine swift Apus melba. This technique is based on the PCR amplification of telomeric (TTAGGG)(n) sequences using specific oligonucleotide primers. Relative telomere length is expressed as the ratio (T/S) of telomere repeat copy number (T) to control single gene copy number (S). This method is particularly useful for comparisons of individuals within species, or where the same individuals are followed longitudinally. We used glyceraldehyde-3-phosphate dehydrogenase (GAPDH) as a single control gene. In both species, we validated our PCR measurements of relative telomere length against absolute measurements of telomere length determined by the conventional method of quantifying telomere terminal restriction fragment (TRF) lengths using both the traditional Southern blot analysis (Alpine swifts) and in gel hybridization (zebra finches). As found in humans and mice, telomere lengths in the same sample measured by TRF and PCR were well correlated in both the Alpine swift and the zebra finch.. Hence, this PCR assay for measurement of bird telomeres, which is fast and requires only small amounts of genomic DNA, should open new avenues in the study of environmental factors influencing variation in telomere length, and how this variation translates into variation in cellular and whole organism senescence.
Resumo:
PURPOSE OF REVIEW: Intensive insulin therapy titrated to restore and maintain blood glucose between 80 and 110 mg/dl (4.4-6.1 mmol/l) was found to improve survival of critically ill patients in one pioneering proof-of-concept study performed in a surgical intensive care unit. The external validity of these findings was investigated. RECENT FINDINGS: Six independent prospective randomized controlled trials, involving 9877 patients in total, were unable to confirm the survival benefit reported in the pioneering trial. Several hypotheses were proposed to explain this discrepancy, including the case-mix, the features of the usual care, the quality of glucose control and the risks associated with hypoglycemia. SUMMARY: Before a better understanding and delineation of the conditions associated with and improved outcome by tight glycemic control, the choice of an intermediate glycemic target appears as a safe and effective solution.
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Resumo:
Self-measurement of blood pressure at home is increasingly used in the diagnostic and therapeutic approach of hypertension. This technique allows multiple measurements of blood pressure away from the clinical setting, making it possible to improve the evaluation of cardiovascular risk. Recently new guidelines on the use of self-measured blood pressure have been made available by the European Society of Hypertension, as summarized in the present paper.
Resumo:
PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.
Resumo:
BACKGROUND AND PURPOSE: Knowledge of cerebral blood flow (CBF) alterations in cases of acute stroke could be valuable in the early management of these cases. Among imaging techniques affording evaluation of cerebral perfusion, perfusion CT studies involve sequential acquisition of cerebral CT sections obtained in an axial mode during the IV administration of iodinated contrast material. They are thus very easy to perform in emergency settings. Perfusion CT values of CBF have proved to be accurate in animals, and perfusion CT affords plausible values in humans. The purpose of this study was to validate perfusion CT studies of CBF by comparison with the results provided by stable xenon CT, which have been reported to be accurate, and to evaluate acquisition and processing modalities of CT data, notably the possible deconvolution methods and the selection of the reference artery. METHODS: Twelve stable xenon CT and perfusion CT cerebral examinations were performed within an interval of a few minutes in patients with various cerebrovascular diseases. CBF maps were obtained from perfusion CT data by deconvolution using singular value decomposition and least mean square methods. The CBF were compared with the stable xenon CT results in multiple regions of interest through linear regression analysis and bilateral t tests for matched variables. RESULTS: Linear regression analysis showed good correlation between perfusion CT and stable xenon CT CBF values (singular value decomposition method: R(2) = 0.79, slope = 0.87; least mean square method: R(2) = 0.67, slope = 0.83). Bilateral t tests for matched variables did not identify a significant difference between the two imaging methods (P >.1). Both deconvolution methods were equivalent (P >.1). The choice of the reference artery is a major concern and has a strong influence on the final perfusion CT CBF map. CONCLUSION: Perfusion CT studies of CBF achieved with adequate acquisition parameters and processing lead to accurate and reliable results.
Resumo:
Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.
Resumo:
Combining bacterial bioreporters with microfluidics systems holds great promise for in-field detection of chemical or toxicity targets. Recently we showed how Escherichia coli cells engineered to produce a variant of green fluorescent protein after contact to arsenite and arsenate can be encapsulated in agarose beads and incorporated into a microfluidic chip to create a device for in-field detection of arsenic, a contaminant of well known toxicity and carcinogenicity in potable water both in industrialized and developing countries. Cell-beads stored in the microfluidics chip at -20°C retained inducibility up to one month and we were able to reproducibly discriminate concentrations of 10 and 50 μg arsenite per L (the drinking water standards for European countries and the United States, and for the developing countries, respectively) from the blank in less than 200 minutes. We discuss here the reasons for decreasing bioreporter signal development upon increased storage of cell beads but also show how this decrease can be reduced, leading to a faster detection and a longer lifetime of the device.