243 resultados para Fibre comparison


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Most patients miss occasional doses of antihypertensives. The use of 'forgiving' drugs (i.e. drugs with duration of action longer than the 24-h dosing interval) may allow an adequate blood pressure (BP) reduction to be maintained despite missed doses. Aim:To quantify the effects of adherence level and duration of action on estimated mean systolic BP (SBP) reduction and cardiovascular disease (CVD) risk. Method:For 1250 patients, we simulated 256-day dosing histories with realistically distributed drug holidays based on a study of electronically monitored dosing records. Adherence was set to the desired level by altering the proportion of doses missed. Mean office SBP-lowering effect (aliskiren 300 mg, -14.1 mmHg; irbesartan 300 mg, -13.3; ramipril 10 mg, -10.1 mmHg) and the rate of SBP increase after stopping treatment (off-rate; aliskiren, 1.0 mmHg/day; irbesartan, 3.6 mmHg/day; ramipril, 4.0 mmHg/day) were taken from the results of a randomised, double-blind trial. SBP was averaged over time and patient to estimate mean reductions in SBP and 10-year CVD risk (Framingham risk equation, baseline absolute 10-year CVD risk: 27%). Results:Predicted reductions in SBP and CVD risk with aliskiren were larger and less affected by imperfect adherence than the reductions with irbesartan or ramipril. For aliskiren, reducing adherence from 90% to 60% led to a predicted rise in SBP of 1.0 mmHg and three additional CVD events per 1000 treated patients; larger predicted differences were observed for irbesartan (2.5 mmHg; 7.5 events/1000 treated patients) and ramipril (2.2 mmHg; 6.7 events/1000 treated patients). Conclusion:To offset the effects of imperfect adherence, a common challenge with antihypertensives, for better BP management it may be prudent to prescribe 'forgiving' drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We performed an analysis of a substudy of the randomized Tamoxifen Exemestane Adjuvant Multinational trial to determine the effects of exemestane (EXE) and tamoxifen (TAM) adjuvant treatment on bone mineral density (BMD) measured by dual-energy X-ray absorptiometry compared with the trabecular bone score, a novel grey-level texture measurement that correlates with 3-dimensional parameters of bone texture in postmenopausal women with hormone receptor-positive breast cancer for the first time. In total, 36 women were randomized to receive TAM (n = 17) or EXE (n = 19). Patients receiving TAM showed a mean increase of BMD in lumbar spine from baseline of 1.0%, 1.5%, and 1.9% and in trabecular bone score of 2.2%, 3.5%, and 3.3% at 6-, 12-, and 24-mo treatment, respectively. Conversely, patients receiving EXE showed a mean decrease from baseline in lumbar spine BMD of -2.3%, -3.6%, and -5.3% and in trabecular bone score of -0.9%, -1.7%, and -2.3% at 6-, 12-, and 24-mo treatment, respectively. Changes in trabecular bone score from baseline at spine were also significantly different between EXE and TAM: p = 0.05, 0.007, and 0.006 at 6, 12, and 24mo, respectively. TAM induced an increase in BMD and bone texture analysis, whereas EXE resulted in decreases. The results were independent from each other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: TIDratio indirectly reflects myocardial ischemia and is correlated with cardiacprognosis. We aimed at comparing the influence of three different softwarepackages for the assessment of TID using Rb-82 cardiac PET/CT. Methods: Intotal, data of 30 patients were used based on normal myocardial perfusion(SSS<3 and SRS<3) and stress myocardial blood flow 2mL/min/g)assessed by Rb-82 cardiac PET/CT. After reconstruction using 2D OSEM (2Iterations, 28 subsets), 3-D filtering (Butterworth, order=10, ωc=0.5), data were automatically processed, and then manually processed fordefining identical basal and apical limits on both stress and rest images.TIDratio were determined with Myometrix®, ECToolbox® and QGS®software packages. Comparisons used ANOVA, Student t-tests and Lin concordancetest (ρc). Results: All of the 90 processings were successfullyperformed. TID ratio were not statistically different between software packageswhen data were processed automatically (P=0.2) or manually (P=0.17). There was a slight, butsignificant relative overestimation of TID with automatic processing incomparison to manual processing using ECToolbox® (1.07 ± 0.13 vs 1.0± 0.13, P=0.001)and Myometrix® (1.07 ± 0.15 vs 1.01 ± 0.11, P=0.003) but not using QGS®(1.02 ±0.12 vs 1.05 ± 0.11, P=0.16). The best concordance was achieved between ECToolbox®and Myometrix® manual (ρc=0.67) processing.Conclusion: Using automatic or manual mode TID estimation was not significantlyinfluenced by software type. Using Myometrix® or ECToolbox®TID was significantly different between automatic and manual processing, butnot using QGS®. Software package should be account for when definingTID normal reference limits, as well as when used in multicenter studies. QGS®software seemed to be the most operator-independent software package, whileECToolbox® and Myometrix® produced the closest results.