237 resultados para Radiation Sensitivity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Our retrospective, international study aimed at evaluating the activity and safety of eribulin mesylate (EM) in pretreated metastatic breast cancer (MBC) in a routine clinical setting. METHODS: Patients treated with EM for a locally advanced or MBC between March 2011 and January 2014 were included in the study. Clinical and biological assessment of toxicity was performed at each visit. Tumour response was assessed every 3 cycles of treatment. A database was created to collect clinical, pathological and treatment data. RESULTS: Two hundred and fifty-eight patients were included in the study. Median age was 59 years old. Tumours were Hormone Receptor (HR)-positive (73.3 %) HER2-positive (10.2 %), and triple negative (TN, 22.5 %). 86.4 % of the patients presented with visceral metastases, mainly in the liver (67.4 %). Median previous metastatic chemotherapies number was 4 [1-9]. Previous treatments included anthracyclines and/or taxanes (100 %) and capecitabine (90.7 %). Median number of EM cycles was 5 [1-19]. The relative dose intensity was 0.917. At the time of analysis (median follow-up of 13.9 months), 42.3 % of the patients were still alive. The objective response rate was 25.2 % (95 %CI: 20-31) with a 36.1 % clinical benefit rate (CBR). Median time to progression (TTP) and overall survival were 3.97 (95 %CI: 3.25-4.3) and 11.2 (95 %CI: 9.3-12.1) months, respectively. One- and 2-year survival rates were 45.5 and 8.5 %, respectively. In multivariate analysis, HER2 positivity (HR = 0.29), the presence of lung metastases (HR = 2.49) and primary taxanes resistance (HR = 2.36) were the only three independent CBR predictive factors, while HR positivity (HR = 0.67), the presence of lung metastases (HR = 1.52) and primary taxanes resistance (HR = 1.50) were the only three TTP independent prognostic factors. Treatment was globally well tolerated. Most common grade 3-4 toxicities were neutropenia (20.9 %), peripheral neuropathy (3.9 %), anaemia (1.6 %), liver dysfunction (0.8 %) and thrombocytopenia (0.4 %). Thirteen patients (5 %) developed febrile neutropenia. CONCLUSION: EM is an effective new option in heavily pretreated MBC, with a favourable efficacy/safety ratio in a clinical practice setting. Our results comfort the use of this new molecule and pledge for the evaluation of EM-trastuzumab combination in this setting. Tumour biology, primary taxanes sensitivity and metastatic sites could represent useful predictive and prognostic factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le cancer du poumon est la première cause de mortalité associée au cancer dans le monde. Le traitement curatif des tumeurs pulmonaires non-à-petites-cellules (NSCLC) diagnostiquées à un stade précoce se base sur une approche chirurgicale. Cependant, étant donné les comorbidités liées à la consommation de tabac, dont la bronchopneumopathie chronique occupe la première place, l'éligibilité chirurgicale pour ce type de cancer se trouve fréquemment limitée. Dans ce contexte, l'emploi de la radiothérapie stéréotaxique (SBRT) est une alternative valable chez les patients atteints d'un NSCLC primaire de stade précoce, et qui sont considérés inopérables à cause de leurs comorbidités. Depuis peu seulemement, le spectre de la SBRT a été élargi aux patients atteints d'un deuxième NSCLC primaire (SPLC), faisant suite à un premier NSCLC, traité avec un but curatif. Ils concernent donc des patients ayant déjà subits une intervention chirurgicale au préalable et qui présentent une réserve fonctionnelle pulmonaire extrêmement réduite. Le succès croissant de la SBRT résulte soit d'une efficacité thérapeutique comparables à la chirurgie, soit de sa toxicité qui semble limitée. À notre connaissance, seulement une étude a reporté des issues cliniques de patients affectés par des NSCLC primaires traités par SBRT. Cette dernière a utilisé la tomothérapie comme système d'irradiation (T-SBRT), sur un faible échantillon de patients (n = 27). Concernant l'irradiation des patients présentant des SPLC, la littérature disponible est pauvre et aucune publication a décrit l'utilisation de la T-SBRT. Ces éléments innovants ont donc motivé la rédaction d'un travail de thèse concernant les premières données cliniques de l'expérience faite au CHUV. Du point de vue des effets secondaires, si la pneumonie actinique précoce et tardive survenant au niveau du champ d'irradiation est désormais une complication iatrogène bien connue de la SBRT, une seule étude s'est intéressée à ce sujet dans le cadre de la T-SBRT. De plus, une entité bénigne et transitoire de pneumonie ( ?) a été reconnue depuis peu : la pneumonie organisée radio-induite (OP). Celle-ci semble se chevaucher comme un autre effet iatrogène à l'extérieur du champ d'irradiation. Originellement, cette dernière avait été rapportée dans les suites de la radiothérapie pour les cancer du sein. Elle a été décrite comme étant initialement limitée au champ d'irradiation et successivement pouvant s'étendre dynamiquement en dehors de celui-ci. Nous avons donc supposé que des infiltrats de OP peuvent être présents chez des patients asymptomatiques, et que ce dynamisme pourrait être identifié déjà au sein du champ d'irradiation. Notre étude a démontré que le traitement par T-SBRT garde des issues cliniques très encourageantes, aussi bien pour les tumeurs primaires que pour les SPLC. Entre autre, ce traitement semble avoir une toxicité limitée, et l'existence vraisemblable de la OP, déjà au sein du champ d'irradiation, peut aider les radiologues à différencier les infiltrats radio-induits d'une une récidive tumorale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(Matrix-assisted) laser desorption/ionization ((MA)LDI) mass spectrometry imaging (MSI) has been driven by remarkable technological developments in the last couple of years. Although molecular information of a wide range of molecules including peptides, lipids, metabolites, and xenobiotics can be mapped, (MA)LDI MSI only leads to the detection of the most abundant soluble molecules in the cells and, consequently, does not provide access to the least expressed species, which can be very informative in the scope of disease research. Within a short period of time, numerous protocols and concepts have been developed and introduced in order to increase MSI sensitivity, including in situ tissue chemistry and solvent-free matrix depositions. In this chapter, we will discuss some of the latest developments in the field of high-sensitivity MSI using solvent-free matrix depositions and will detail protocols of two methods with their capability of enriching molecular MSI signal as demonstrated within our laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of image quality (IQ) in Computed Tomography (CT) is important to ensure that diagnostic questions are correctly answered, whilst keeping radiation dose to the patient as low as is reasonably possible. The assessment of individual aspects of IQ is already a key component of routine quality control of medical x-ray devices. These values together with standard dose indicators can be used to give rise to 'figures of merit' (FOM) to characterise the dose efficiency of the CT scanners operating in certain modes. The demand for clinically relevant IQ characterisation has naturally increased with the development of CT technology (detectors efficiency, image reconstruction and processing), resulting in the adaptation and evolution of assessment methods. The purpose of this review is to present the spectrum of various methods that have been used to characterise image quality in CT: from objective measurements of physical parameters to clinically task-based approaches (i.e. model observer (MO) approach) including pure human observer approach. When combined together with a dose indicator, a generalised dose efficiency index can be explored in a framework of system and patient dose optimisation. We will focus on the IQ methodologies that are required for dealing with standard reconstruction, but also for iterative reconstruction algorithms. With this concept the previously used FOM will be presented with a proposal to update them in order to make them relevant and up to date with technological progress. The MO that objectively assesses IQ for clinically relevant tasks represents the most promising method in terms of radiologist sensitivity performance and therefore of most relevance in the clinical environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality at CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality of CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: There is now solid evidence for a relation between adverse life events (ALE) and psychotic symptoms in patients with psychosis and in the general population. A recent study has shown that this relation may be partially mediated by stress sensitivity, suggesting the influence of other factors. The aim of this study was to assess the mediation effect of emotion regulation strategies and stress sensitivity in the relation between ALE and attenuated positive psychotic symptoms (APPS) in the general population. METHODS: Hundred and twelve healthy volunteers were evaluated with measures of APPS, emotion regulation strategies, ALE and stress sensitivity. RESULTS: Results demonstrated that the relation between ALE, hallucination and delusion proneness was completely mediated by maladaptive emotion regulation strategies, but not by stress sensitivity. However, in addition to maladaptive emotion regulation strategies, stress sensitivity demonstrated a mediation effect between ALE and attenuated positive psychotic positive symptoms when positive psychotic symptoms were grouped together. CONCLUSIONS: There are probably several possible trajectories leading to the formation of positive psychotic symptoms and the results of the present study reveal that one such trajectory may involve the maladaptive regulation of negative emotions alongside a certain general vulnerability after experiencing ALE.