296 resultados para Flow quantification
Resumo:
Previous studies have demonstrated that poultry house workers are exposed to very high levels of organic dust and consequently have an increased prevalence of adverse respiratory symptoms. However, the influence of the age of broilers on bioaerosol concentrations has not been investigated. To evaluate the evolution of bioaerosol concentration during the fattening period, bioaerosol parameters (inhalable dust, endotoxin and bacteria) were measured in 12 poultry confinement buildings in Switzerland, at three different stages of the birds' growth; samples of air taken from within the breathing zones of individual poultry house employees as they caught the chickens ready to be transported for slaughter were also analysed. Quantitative polymerase chain reaction (Q-PCR) was used to assess the quantity of total airborne bacteria and total airborne Staphylococcus species. Bioaerosol levels increased significantly during the fattening period of the chickens. During the task of catching mature birds, the mean inhalable dust concentration for a worker was 26 +/- 1.9 mg m(-3) and endotoxin concentration was 6198 +/- 2.3 EU m(-3) air, >6-fold higher than the Swiss occupational recommended value (1000 EU m(-3)). The mean exposure level of bird catchers to total bacteria and Staphylococcus species measured by Q-PCR is also very high, respectively, reaching values of 53 (+/-2.6) x 10(7) cells m(-3) air and 62 (+/-1.9) x 10(6) m(-3) air. It was concluded that in the absence of wearing protective breathing apparatus, chicken catchers in Switzerland risk exposure beyond recommended limits for all measured bioaerosol parameters. Moreover, the use of Q-PCR to estimate total and specific numbers of airborne bacteria is a promising tool for evaluating any modifications intended to improve the safety of current working practices
Resumo:
Mise en perspective Le rein est un organe vital dont la fonction dépend en grande partie d'une perfusion tissulaire adéquate. Les techniques actuellement utilisées pour étudier la microcirculation rénale sont soit invasives soit très dispendieuses. L'échographie de contraste est une nouvelle technologie, non invasive, facile à réaliser au lit du malade et pour laquelle certaines techniques récemment présentées semblent permettre de quantifier la perfusion d'un organe. Une telle technique pourrait avoir des applications dans l'étude de l'insuffisance rénale aiguë. Buts de l'étude Notre étude vise à tester le potentiel de l'échographie de contraste pour détecter des modifications de la perfusion rénale, corticale et médullaire chez l'être humain. Plan de l'étude Nous avons étudié la microcirculation rénale par échographie de contraste chez 12 sujets sains. Les mesures ont été réalisées en baseline puis sous perfusion de doses croissantes d'angiotensine II (un puissant et spécifique vasoconstricteur rénal) et enfin après la prise orale d'un comprimé de Captopril (un puissant vasodilatateur rénal). Les valeurs obtenues par échographie de contraste ont été comparées à la perfusion globale rénale évaluée par la clairance du PAH, qui constitue le gold standard en physiologie rénale. Résultats principaux Le protocole a pu être réalisé sans complication. Les perfusions vasoactives ainsi que les différentes administrations de Sonovue ont été parfaitement tolérées. Les séquences vidéos ont été analysées par deux lecteurs et une bonne concordance a été trouvée. Nous avons trouvé une diminution statistiquement significative et dose dépendante de l'index de perfusion rénale lors de la perfusion d'angiotensine II: -45% (p<0.02) entre baseline et Ang II faible dose et -65% (p<0.01) entre baseline et Ang II à haute dose. Enfin, nous avons observé une hausse significative de cet indice après administration orale de Captopril (+35%, p>0.2). Ces changements étaient parallèles aux changements de flux plasmatique rénal mesurés par calcul de la clairance du PAH. Une corrélation moyenne mais significative (r=0.57, p=0.002) a été observée entre ces deux mesures. Conclusions et perspectives L'échographie de contraste est capable de détecter des modifications dans la microcirculation rénale induites par une perfusion d'angiotensine et ou une administration de Captopril. Il s'agit d'une technique rapide sensible et fiable qui pourrait participer à l'évaluation des patients souffrant d'insuffisance rénale aiguë. D'autres études sont nécessaires pour démontrer son utilité dans un contexte clinique.
Resumo:
Tumour immunologists strive to develop efficient tumour vaccination and adoptive transfer therapies that enlarge the pool of tumour-specific and -reactive effector T-cells in vivo. To assess the efficiency of the various strategies, ex vivo assays are needed for the longitudinal monitoring of the patient's specific immune responses providing both quantitative and qualitative data. In particular, since tumour cell cytolysis is the end goal of tumour immunotherapy, routine immune monitoring protocols need to include a read-out for the cytolytic efficiency of Ag-specific cells. We propose to combine current immune monitoring techniques in a highly sensitive and reproducible multi-parametric flow cytometry based cytotoxicity assay that has been optimised to require low numbers of Ag-specific T-cells. The possibility of re-analysing those T-cells that have undergone lytic activity is illustrated by the concomitant detection of CD107a upregulation on the surface of degranulated T-cells. To date, the LiveCount Assay provides the only possibility of assessing the ex vivo cytolytic activity of low-frequency Ag-specific cytotoxic T-lymphocytes from patient material.
Resumo:
Purpose: Aqueous flow through trabeculectomy blebs has been suggested to influence filtration bleb survival. We investigated the relationship between the requirement to increase aqueous flow via adjustable suture removal and surgical outcomes following "safe trabeculectomy" with mitomycin C (MMC). Methods: 62 consecutive eyes of 53 patients underwent fornix based trabeculectomy with adjustable sutures, intraoperative MMC and intensive postoperative steroids. Subconjunctival antimetabolite injections and bleb needlings were administered according to bleb vascularity and IOP trends. Main outcome measures were: success rates (definition: IOP≤21mmHg and 20% IOP reduction); number of antimetabolite injections; bleb needlings; number of of eyes recommencing glaucoma medications and complications. Results: Mean age was 70.4±16.0 years (mean± SD); mean preoperative IOP was 24.5±9.1 mmHg and decreased to 12.3±8.9mmHg postoperatively. Mean number of sutures was 2.6 ± 0.7. Eyes were divided into 2 groups in relation to the number of sutures removed. The number of subconjunctival MMC injections required for those requiring 2 suture removals was significantly greater than those requiring 1 suture removal (p<0.05) The number of needlings and 5FU injections also increased but did not reach significance (p=0.09 and p=0.34 respectively). Least-squared linear regression analysis showed the number of needlings required had a statistically significant (p=0.05) trend with respect to time elapsed between surgery and first suture removal. No other interventions had significant trends. Mean time between surgery and suture removal was: 4.2±9.2 weeks (suture #1) and 5.7±9.7 weeks (suture#2). Antiglaucoma medication was restarted in only 5 eyes. Postoperative complications were infrequent: Seidel (3.2%), peripheral choroidal effusions at any time (3.2%), and shallow anterior chamber (1.6%). Conclusion: Eyes requiring a greater number of suture removals required a significantly greater number of antifibrosis interventions. The time elapsed before suture removal was inversely related to the number of postoperative needlings, suggesting these eyes may have decreased aqueous production and therefore require aggressive post-operative management to prevent bleb failure.
Resumo:
Here, we describe a case of an HIV-infected patient with right lower limb oedema that appeared after initiation of tenofovir and emtricitabine treatment. The patient was fully investigated by serial heart and vessel echo-Doppler examination. Oedema of the lower limb was attributed to a transient drug-induced fivefold increase in peripheral artery flow, which was induced by a reduction in peripheral arterial resistance. The possible mechanisms of disease are discussed.
Resumo:
Background. Anastomotic leak remains a common and potentially deleterious complication after esophagectomy. Preoperative embolization of the left gastric artery and splenic artery (PAE) has been suggested to lower anastomotic leak rates. We present the results of our 5-year experience with this technique.Methods. All patients undergoing PAE before esophagectomy since introduction of this technique in 2004 were compared in a 1: 2 matched-pair analysis with patients without PAE. Matching criteria were type of anastomosis, neoadjuvant treatment, comorbidity, and age. Data were derived from a retrospective chart review from 2000 to 2006 that was perpetuated as a prospective database up to date. Outcome measures were anastomotic leak, overall complications, and hospital stay.Results. Between 2000 and 2009, 102 patients underwent esophagectomy for cancer in our institution with an overall leak rate of 19% and a mortality of 8%. All 19 patients having PAE since 2004 were successfully matched 1: 2 to 38 control patients without PAE; both groups were similar regarding demographics and operation characteristics. Two PAE (11%) and 8 control patients (21%) had an anastomotic leak, but the difference was statistically not significant (p = 0.469). Overall and major complication rates for PAE and control group were 89% versus 79% (p = 0.469) and 37% versus 34% (p = 1.000), respectively. Median intensive care unit and hospital stay were 3 versus 3 days (p = 1.000) and 22 versus 17 days (p = 0.321), respectively.Conclusions. In our experience, PAE has no significant impact on complications and anastomotic leak in particular after esophagectomy. (Ann Thorac Surg 2011;91:1556-61) (C) 2011 by The Society of Thoracic Surgeons
Resumo:
Several definitions of paediatric abdominal obesity have been proposed but it is unclear whether they lead to similar results. We assessed the prevalence of abdominal obesity using five different waist circumference-based definitions and their agreement with total body fat (TBF) and abdominal fat (AF). Data from 190 girls and 162 boys (Ballabeina), and from 134 girls and 113 boys (Kinder-Sportstudie, KISS) aged 5-11 years were used. TBF was assessed by bioimpedance (Ballabeina) or dual energy X-ray absorption (KISS). On the basis of the definition used, the prevalence of abdominal obesity varied between 3.1 and 49.4% in boys, and 4.7 and 55.5% in girls (Ballabeina), and between 1.8 and 36.3% in boys and 4.5 and 37.3% in girls (KISS). Among children considered as abdominally obese by at least one definition, 32.0 (Ballabeina) and 44.7% (KISS) were considered as such by at least two (out of five possible) definitions. Using excess TBF or AF as reference, the areas under the receiver operating curve varied between 0.577 and 0.762 (Ballabeina), and 0.583 and 0.818 (KISS). We conclude that current definitions of abdominal obesity in children lead to wide prevalence estimates and should not be used until a standard definition can be proposed.
Resumo:
Rough a global coarse problem. Although these techniques are usually employed for problems in which the fine-scale processes are described by Darcy's law, they can also be applied to pore-scale simulations and used as a mathematical framework for hybrid methods that couples a Darcy and pore scales. In this work, we consider a pore-scale description of fine-scale processes. The Navier-Stokes equations are numerically solved in the pore geometry to compute the velocity field and obtain generalized permeabilities. In the case of two-phase flow, the dynamics of the phase interface is described by the volume of fluid method with the continuum surface force model. The MsFV method is employed to construct an algorithm that couples a Darcy macro-scale description with a pore-scale description at the fine scale. The hybrid simulations results presented are in good agreement with the fine-scale reference solutions. As the reconstruction of the fine-scale details can be done adaptively, the presented method offers a flexible framework for hybrid modeling.
Resumo:
Arterial Spin Labeling (ASL) is a method to measure perfusion using magnetically labeled blood water as an endogenous tracer. Being fully non-invasive, this technique is attractive for longitudinal studies of cerebral blood flow in healthy and diseased individuals, or as a surrogate marker of metabolism. So far, ASL has been restricted mostly to specialist centers due to a generally low SNR of the method and potential issues with user-dependent analysis needed to obtain quantitative measurement of cerebral blood flow (CBF). Here, we evaluated a particular implementation of ASL (called Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated and a total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing mean displacements of 1.87+/-0.95 mm and rotations of 1.56+/-0.66 degrees . Mean gray matter CBF was 47.4+/-7.5 [ml/100 g/min] with a between-subject standard variation SD(b)=5.5 [ml/100 g/min] and a within-subject standard deviation SD(w)=4.7 [ml/100 g/min]. The corresponding repeatability was 13.0 [ml/100 g/min] and was found to be within the range of previous studies.
Resumo:
BACKGROUND: This study validates the use of phycoerythrin (PE) and allophycocyanin (APC) for fluorescence energy transfer (FRET) analyzed by flow cytometry. METHODS: FRET was detected when a pair of antibody conjugates directed against two noncompetitive epitopes on the same CD8alpha chain was used. FRET was also detected between antibody conjugate pairs specific for the two chains of the heterodimeric alpha (4)beta(1) integrin. Similarly, the association of T-cell receptor (TCR) with a soluble antigen ligand was detected by FRET when anti-TCR antibody and MHC class I/peptide complexes (<<tetramers>>) were used. RESULTS: FRET efficiency was always less than 10%, probably because of steric effects associated with the size and structure of PE and APC. Some suggestions are given to take into account this and other effects (e.g., donor and acceptor concentrations) for a better interpretation of FRET results obtained with this pair of fluorochromes. CONCLUSIONS: We conclude that FRET assays can be carried out easily with commercially available antibodies and flow cytometers to study arrays of multimolecular complexes.
Resumo:
Neuropeptide Y (NPY) is a peptide with vasoconstrictor properties known to be present in the central nervous system as well as in sympathetic nerve endings and the adrenal medulla. The purposes of this study were to investigate in normotensive conscious rats the effects of nonpressor doses of NPY on cardiac output and regional blood flow distribution (using radiolabeled microspheres) as well as on plasma renin activity, plasma catecholamine and vasopressin levels. NPY (0.1 microgram/min) infused i.v. for 30 min modified neither blood pressure nor heart rate. Cardiac index was at comparable levels in NPY- as in vehicle-treated rats (17.7 +/- 1.6, n = 8, vs. 21.3 +/- 0.9 ml/min/100 g, n = 8, mean +/- S.E.M.). There was no significant difference in regional blood flow distribution between the two groups of rats, except for the large intestine (0.42 +/- 0.06 vs. 0.71 +/- 0.1 ml/min/g in NPY- and vehicle-treated rats, respectively, P less than .05). Basal plasma renin activity and catecholamine levels were not modified by NPY whereas plasma vasopressin levels were lower (P less than .05) in rats given NPY (0.76 +/- 0.3 pg/ml, n = 8) than in those having received the vehicle (2.2 +/- 0.4 pg/ml).(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
A total of 49 wastewater samples from 23 different wastewater treatment plants (WWTPs) were analyzed using real-time quantitative polymerase chain reaction for the presence and quantity of thermotolerant campylobacters. Thermotolerant campylobacters were detected in 87.5% (21/24) and 64% (16/25) of untreated and treated wastewater samples, respectively. Their concentration was sufficiently high to be quantified in 20.4% (10/49) of the samples. In these samples, the concentration ranged from 68 000 to 2292 000 cells/L in untreated wastewater and from 10 800 to 28 000 cells/L in treated water. We conclude that thermotolerant campylobacters present a health hazard for workers at WWTPs in Switzerland. [Authors]
Resumo:
PURPOSE: Visualization of coronary blood flow in the right and left coronary system in volunteers and patients by means of a modified inversion-prepared bright-blood coronary magnetic resonance angiography (cMRA) sequence. MATERIALS AND METHODS: cMRA was performed in 14 healthy volunteers and 19 patients on a 1.5 Tesla MR system using a free-breathing 3D balanced turbo field echo (b-TFE) sequence with radial k-space sampling. For magnetization preparation a slab selective and a 2D selective inversion pulse were used for the right and left coronary system, respectively. cMRA images were evaluated in terms of clinically relevant stenoses (< 50 %) and compared to conventional catheter angiography. Signal was measured in the coronary arteries (coro), the aorta (ao) and in the epicardial fat (fat) to determine SNR and CNR. In addition, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: The use of a selective inversion pre-pulse allowed direct visualization of the coronary blood flow in the right and left coronary system. The measured SNR and CNR, vessel length, and vessel sharpness in volunteers (SNR coro: 28.3 +/- 5.0; SNR ao: 37.6 +/- 8.4; CNR coro-fat: 25.3 +/- 4.5; LAD: 128.0 cm +/- 8.8; RCA: 74.6 cm +/- 12.4; Sharpness: 66.6 % +/- 4.8) were slightly increased compared to those in patients (SNR coro: 24.1 +/- 3.8; SNR ao: 33.8 +/- 11.4; CNR coro-fat: 19.9 +/- 3.3; LAD: 112.5 cm +/- 13.8; RCA: 69.6 cm +/- 16.6; Sharpness: 58.9 % +/- 7.9; n.s.). In the patient study the assessment of 42 coronary segments lead to correct identification of 10 clinically relevant stenoses. CONCLUSION: The modification of a previously published inversion-prepared cMRA sequence allowed direct visualization of the coronary blood flow in the right as well as in the left coronary system. In addition, this sequence proved to be highly sensitive regarding the assessment of clinically relevant stenotic lesions.
Resumo:
The use of herbicides in agriculture may lead to environmental problems, such as surface water pollution, with a potential risk for aquatic organisms. The herbicide glyphosate is the most used active ingredient in the world and in Switzerland. In the Lavaux vineyards it is nearly the only molecule applied. This work aimed at studying its fate in soils and its transfer to surface waters, using a multi-scale approach: from molecular (10-9 m) and microscopic scales (10-6 m), to macroscopic (m) and landscape ones (103 m). First of all, an analytical method was developed for the trace level quantification of this widely used herbicide and its main by-product, aminomethylphosphonic acid (AMPA). Due to their polar nature, their derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) was done prior to their concentration and purification by solid phase extraction. They were then analyzed by ultra performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS). The method was tested in different aqueous matrices with spiking tests and validated for the matrix effect correction in relevant environmental samples. Calibration curves established between 10 and 1000ng/l showed r2 values above 0.989, mean recoveries varied between 86 and 133% and limits of detection and quantification of the method were as low as 5 and 10ng/l respectively. At the parcel scale, two parcels of the Lavaux vineyard area, located near the Lutrive River at 6km to the east of Lausanne, were monitored to assess to which extent glyphosate and AMPA were retained in the soil or exported to surface waters. They were equipped at their bottom with porous ceramic cups and runoff collectors, which allowed retrieving water samples for the growing seasons 2010 and 2011. Results revealed that the mobility of glyphosate and AMPA in the unsaturated zone was likely driven by the precipitation regime and the soil characteristics, such as slope, porosity structure and layer permeability discrepancy. Elevated glyphosate and AMPA concentrations were measured at 60 and 80 cm depth at parcel bottoms, suggesting their infiltration in the upper parts of the parcels and the presence of preferential flow in the studied parcels. Indeed, the succession of rainy days induced the gradual saturation of the soil porosity, leading to rapid infiltration through macropores, as well as surface runoff formation. Furthermore, the presence of more impervious weathered marls at 100 cm depth induced throughflows, the importance of which for the lateral transport of the herbicide molecules was determined by the slope steepness. Important rainfall events (>10 mm/day) were clearly exporting molecules from the soil top layer, as indicated by important concentrations in runoff samples. A mass balance showed that total loss (10-20%) mainly occurred through surface runoff (96%) and, to a minor extent, by throughflows in soils (4%), with subsequent exfiltration to surface waters. Observations made in the Lutrive River revealed interesting details of glyphosate and AMPA dynamics in urbanized landscapes, such as the Lavaux vineyards. Indeed, besides their physical and chemical properties, herbicide dynamics at the catchment level strongly depend on application rates, precipitation regime, land use and also on the presence of drains or constructed channels. Elevated concentrations, up to 4970 ng/l, observed just after the application, confirmed the diffuse export of these compounds from the vineyard area by surface runoff during main rain events. From April to September 2011, a total load of 7.1 kg was calculated, with 85% coming from vineyards and minor urban sources and 15% from arable crops. Small vineyard surfaces could generate high concentrations of herbicides and contribute considerably to the total load calculated at the outlet, due to their steep slopes (~10%). The extrapolated total amount transferred yearly from the Lavaux vineyards to the Lake of Geneva was of 190kg. At the molecular scale, the possible involvement of dissolved organic matter (DOM) in glyphosate and copper transport was studied using UV/Vis fluorescence spectroscopy. Combined with parallel factor (PARAFAC) analysis, this technique allowed characterizing DOM of soil and surface water samples from the studied vineyard area. Glyphosate concentrations were linked to the fulvic-like spectroscopic signature of DOM in soil water samples, as well as to copper, suggesting the formation of ternary complexes. In surface water samples, its concentrations were also correlated to copper ones, but not in a significant way to the fulvic-like signature. Quenching experiments with standards confirmed field tendencies in the laboratory, with a stronger decrease in fluorescence intensity for fulvic-like fluorophore than for more aromatic ones. Lastly, based on maximum concentrations measured in the river, an environmental risk for these compounds was assessed, using laboratory tests and ecotoxicity data from the literature. In our case and with the methodology applied, the risk towards aquatic species was found negligible (RF<1).