255 resultados para reproducibility of calculated surfaces


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this study was to assess the effectiveness of a novel radiation-independent aiming device for distal locking of intramedullary nails in a human cadaver model. METHODS: A new targeting system was used in 25 intact human cadaver femora for the distal locking procedure after insertion of an intramedullary nail. The number of successful screw placements and the time needed for this locking procedure were recorded. The accuracy of the aiming process was evaluated by computed tomography. RESULTS: The duration of the distal locking process was 8.0 ± 1.8 minutes (mean ± SD; range, 4-11 minutes). None of the screw placements required fluoroscopic guidance. Computed tomography revealed high accuracy of the locking process. The incidence angle (α) of the locking screws through the distal locking holes of the nail was 86.8° ± 5.0° (mean ± SD; range, 80°-96°). Targeting failed in 1 static locking screw because of a material defect in the drilling sleeve. CONCLUSIONS: This cadaver study indicated that an aiming arm-based targeting device is highly reliable and accurate. The promising results suggest that it will help to decrease radiation exposure compared with the traditional "free-hand technique."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this investigation, high-resolution, 1x1x1-mm(3) functional magnetic resonance imaging (fMRI) at 7 T is performed using a multichannel array head coil and a surface coil approach. Scan geometry was optimized for each coil separately to exploit the strengths of both coils. Acquisitions with the surface coil focused on partial brain coverage, while whole-brain coverage fMRI experiments were performed with the array head coil. BOLD sensitivity in the occipital lobe was found to be higher with the surface coil than with the head array, suggesting that restriction of signal detection to the area of interest may be beneficial for localized activation studies. Performing independent component analysis (ICA) decomposition of the fMRI data, we consistently detected BOLD signal changes and resting state networks. In the surface coil data, a small negative BOLD response could be detected in these resting state network areas. Also in the data acquired with the surface coil, two distinct components of the positive BOLD signal were consistently observed. These two components were tentatively assigned to tissue and venous signal changes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: to assess the levels and determinants of interleukin (IL)-1ß, IL-6, tumour necrosis factor (TNF)-a and C-reactive protein (CRP) in a healthy Caucasian population.METHODS: population sample of 2884 men and 3201 women aged 35 to 75. IL-1ß, IL-6 and TNF-a were assessed by a multiplexed particle-based flow cytometric assay and CRP by an immunometric assay.RESULTS: Spearman rank correlations between duplicate cytokine measurements (N?=?80) ranged between 0.89 and 0.96; intra-class correlation coefficients ranged between 0.94 and 0.97, indicating good reproducibility. Among the 6085 participants, 2289 (37.6%), 451 (7.4%) and 43 (0.7%) had IL-1ß, IL-6 and TNF-a levels below detection limits, respectively. Median (interquartile range) for participants with detectable values were 1.17 (0.48-3.90) pg/ml for IL-1ß; 1.47 (0.71-3.53) pg/ml for IL-6; 2.89 (1.82-4.53) pg/ml for TNF-a and 1.3 (0.6-2.7) ng/ml for CRP. On multivariate analysis, greater age was the only factor inversely associated with IL-1ß levels. Male sex, increased BMI and smoking were associated with greater IL-6 levels, while no relationship was found for age and leisure-time PA. Male sex, greater age, increased BMI and current smoking were associated with greater TNF-a levels, while no relationship was found with leisure-time PA. CRP levels were positively related to age, BMI and smoking, and inversely to male sex and physical activity.CONCLUSION: Population-based levels of several cytokines were established. Increased age and BMI, and to a lesser degree sex and smoking, significantly and differentially impact cytokine levels, while leisure-time physical activity has little effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Imaging during a period of minimal myocardial motion is of paramount importance for coronary MR angiography (MRA). The objective of our study was to evaluate the utility of FREEZE, a custom-built automated tool for the identification of the period of minimal myocardial motion, in both a moving phantom at 1.5 T and 10 healthy adults (nine men, one woman; mean age, 24.9 years; age range, 21-32 years) at 3 T. CONCLUSION: Quantitative analysis of the moving phantom showed that dimension measurements approached those obtained in the static phantom when using FREEZE. In vitro, vessel sharpness, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were significantly improved when coronary MRA was performed during the software-prescribed period of minimal myocardial motion (p < 0.05). Consistent with these objective findings, image quality assessments by consensus review also improved significantly when using the automated prescription of the period of minimal myocardial motion. The use of FREEZE improves image quality of coronary MRA. Simultaneously, operator dependence can be minimized while the ease of use is improved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the combination of ultrasound (US) + fine-needle aspiration (FNA) in the assessment of salivary gland tumours in the hands of the otolaryngologist. DESIGN: A retrospective review of case notes was performed. SETTING: Two university teaching hospitals in Switzerland. PARTICIPANTS: One hundred and three patients with a total of 106 focal masses of the salivary glands were included. Clinician-operated US + FNA were the first line of investigation for these lesions. All patients underwent surgical excision of the lesion, which allowed for confirmation of diagnosis by histopathology in 104 lesions and by laboratory testing in two lesions. MAIN OUTCOME MEASURES: Primary--diagnostic accuracy in identifying true salivary gland neoplasms and detecting malignancy. Secondary--predicting an approximate and specific diagnosis in these tumours. RESULTS: The combination of US + FNA achieved a diagnostic accuracy of 99% in identifying and differentiating true salivary gland neoplasms from tumour-like lesions. In detecting malignancy, this combination permitted an accuracy of 98%. An approximate diagnosis was possible in 89%, and a specific diagnosis in 69% of our patients. CONCLUSIONS: Due to economic factors and a high diagnostic accuracy, the combination of US + FNA represents the investigation method of choice for most salivary gland tumours. We suggest that the otolaryngologist be employed in carrying out these procedures, as is already the rule in other medical specialties, while computed tomography and magnetic resonance imaging should be reserved to those few lesions, which cannot be delineated completely by sonography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The value of various indexes to characterize the stimulus-response curve of human motor nerves was assessed in 40 healthy subjects recruited from four European centers of investigation (Créteil, Lausanne, Liège, Marseille). Stimulus-response curves were established by stimulating the right median and ulnar motor nerves at the wrist, with stimulus durations of 0.05 and 0.5 ms. The following parameters were studied: the threshold intensity of stimulation to obtain 10% (I 10), 50% (I 50), and 90% (I 90) of the maximal compound muscle action potential, the ratios I 10/I 50, I 90/I 50, (I 90 - I 10)/I 10, (I 90-I 50)/I 50, and (I 50 - I 10)/I 10, and the slopes of the stimulus-response curves with or without normalization to I 50. For each parameter, within-center variability and reproducibility (in a test-retest study) were assessed and between-center comparisons were made. For most of the parameters, the results varied significantly within and between the centers. Within the centers, only the ratios I 10/I 50 and I 90/I 50 were found constant and reproducible. Between the centers, the absolute intensity thresholds (I 10, I 50, I 90) and the ratio I 90/I 50 did not show significant differences at stimulus duration of 0.5 ms, whatever the stimulated nerve. The reduced variability and good reproducibility of the ratios I 10/I 50 and I 90/I 50 open perspectives in neurophysiological practice for the use of these indexes of the stimulus-response curve, a rapid and noninvasive test.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arterial Spin Labeling (ASL) is a method to measure perfusion using magnetically labeled blood water as an endogenous tracer. Being fully non-invasive, this technique is attractive for longitudinal studies of cerebral blood flow in healthy and diseased individuals, or as a surrogate marker of metabolism. So far, ASL has been restricted mostly to specialist centers due to a generally low SNR of the method and potential issues with user-dependent analysis needed to obtain quantitative measurement of cerebral blood flow (CBF). Here, we evaluated a particular implementation of ASL (called Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated and a total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing mean displacements of 1.87+/-0.95 mm and rotations of 1.56+/-0.66 degrees . Mean gray matter CBF was 47.4+/-7.5 [ml/100 g/min] with a between-subject standard variation SD(b)=5.5 [ml/100 g/min] and a within-subject standard deviation SD(w)=4.7 [ml/100 g/min]. The corresponding repeatability was 13.0 [ml/100 g/min] and was found to be within the range of previous studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Smuggling dissolved drugs, especially cocaine, in bottled liquids is an ongoing problem at borders. Common fluoroscopy of packages at the border cannot detect contaminated liquids. The objective of our study was to develop an MDCT screening method to detect cocaine-containing vessels that are hidden between uncontaminated ones in a shipment. MATERIALS AND METHODS: Studies were performed on three wine bottles containing cocaine solutions that were confiscated at the Swiss border. Reference values were obtained by scans of different sorts of commercially available wine and aqueous solutions of dissolved sugar. All bottles were scanned using MDCT, and data evaluation was performed by measuring the mean peak of Hounsfield units. To verify the method, simulated testing was performed. RESULTS: Using measurements of the mean peak of Hounsfield units enables the detection of dissolved cocaine in wine bottles in a noninvasive and rapid fashion. Increasing opacity corresponds well with the concentration of dissolved cocaine. Simulated testing showed that it is possible to distinguish between cocaine-contaminated and uncontaminated wine bottles. CONCLUSION: The described method is an efficacious screening method to detect cocaine-contaminated bottles that are hidden between untreated bottles in cargo. The noninvasive examination of cargo allows a questionable delivery to be tracked without arousing the suspicion of the smugglers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Health-related quality of life (HRQoL) was evaluated in a sample of alcohol-dependent patients with the 36-item Medical Outcome Study Short-Form Health Survey (MOS-SF-36). The instrument was administered to 147 patients (77% males), aged 26-78, with a DSM-III-R diagnosis of alcohol dependence. The Hamilton Depression Scale (HDS), the Severity of Alcohol Dependence Questionnaire (SADQ), and the Addiction Severity Index (ASI) were also administered to the first 100 patients included in the study. The reliability and validity of the MOS-SF-36 were evaluated. Test-retest intraclass coefficients for a 10-day interval were in the range .65 to .79, whereas the Cronbach alpha coefficient indicated good internal consistency (range .70 to .89). Compared to scores observed in the general population, MOS-SF-36 scores for alcohol-dependent patients were relatively low (indicating worse perception of HRQoL), especially in the psychological and role dimensions (range 52/100 to 55/100), but were closer to populational values in the physical and functional dimensions (range 61/100 to 75/100)). The highest correlation between MOS-SF-36 dimensions and HDS was found in the MOS-SF-36 &quot;mental health&quot; dimension (r=-.56, p &lt; .001); this dimension was also correlated highly with the psychiatric dimension of the ASI (r=-.73, p &lt; .001). The eight dimensions of the MOS-SF-36 were 21% to 127% lower in patients with HDS greater than or equal to 16 (major depression) compared to those with HDS less than or equal to 7 (absence of depression). The MOS-SF-36 dimensions were 10% to 141% lower in patients with high &quot;ASI alcohol&quot; scores, indicating worse HRQoL profiles with a higher severity of alcohol dependence. The MOS-SF-36 presents good criteria for reliability and validity in alcohol-dependent patients. The results suggested that alcohol-dependent patients perceived their problems more as psychological than physical. The severity of alcohol dependence and depression seemed to influence the perception of HRQoL negatively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: A homozygous mutation in the H6 family homeobox 1 (HMX1) gene is responsible for a new oculoauricular defect leading to eye and auricular developmental abnormalities as well as early retinal degeneration (MIM 612109). However, the HMX1 pathway remains poorly understood, and in the first approach to better understand the pathway's function, we sought to identify the target genes. METHODS: We developed a predictive promoter model (PPM) approach using a comparative transcriptomic analysis in the retina at P15 of a mouse model lacking functional Hmx1 (dmbo mouse) and its respective wild-type. This PPM was based on the hypothesis that HMX1 binding site (HMX1-BS) clusters should be more represented in promoters of HMX1 target genes. The most differentially expressed genes in the microarray experiment that contained HMX1-BS clusters were used to generate the PPM, which was then statistically validated. Finally, we developed two genome-wide target prediction methods: one that focused on conserving PPM features in human and mouse and one that was based on the co-occurrence of HMX1-BS pairs fitting the PPM, in human or in mouse, independently. RESULTS: The PPM construction revealed that sarcoglycan, gamma (35kDa dystrophin-associated glycoprotein) (Sgcg), teashirt zinc finger homeobox 2 (Tshz2), and solute carrier family 6 (neurotransmitter transporter, glycine) (Slc6a9) genes represented Hmx1 targets in the mouse retina at P15. Moreover, the genome-wide target prediction revealed that mouse genes belonging to the retinal axon guidance pathway were targeted by Hmx1. Expression of these three genes was experimentally validated using a quantitative reverse transcription PCR approach. The inhibitory activity of Hmx1 on Sgcg, as well as protein tyrosine phosphatase, receptor type, O (Ptpro) and Sema3f, two targets identified by the PPM, were validated with luciferase assay. CONCLUSIONS: Gene expression analysis between wild-type and dmbo mice allowed us to develop a PPM that identified the first target genes of Hmx1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We sought to assess the feasibility and reproducibility of performing tissue-based immune characterization of the tumor microenvironment using CT-compatible needle biopsy material. Three independent biopsies were obtained intraoperatively from one metastatic epithelial ovarian cancer lesion of 7 consecutive patients undergoing surgical cytoreduction using a 16-gauge core biopsy needle. Core specimens were snap-frozen and subjected to immunohistochemistry (IHC) against human CD3, CD4, CD8, and FoxP3. A portion of the cores was used to isolate RNA for 1) real-time quantitative (q)PCR for CD3, CD4, CD8, FoxP3, IL-10 and TGF-beta, 2) multiplexed PCR-based T cell receptor (TCR) CDR3 Vβ region spectratyping, and 3) gene expression profiling. Pearson's correlations were examined for immunohistochemistry and PCR gene expression, as well as for gene expression array data obtained from different tumor biopsies. Needle biopsy yielded sufficient tissue for all assays in all patients. IHC was highly reproducible and informative. Significant correlations were seen between the frequency of CD3+, CD8+ and FoxP3+ T cells by IHC with CD3ε, CD8A, and FoxP3 gene expression, respectively, by qPCR (r=0.61, 0.86, and 0.89; all p< 0.05). CDR3 spectratyping was feasible and highly reproducible in each tumor, and indicated a restricted repertoire for specific TCR Vβ chains in tumor-infiltrating T cells. Microarray gene expression revealed strong correlation between different biopsies collected from the same tumor. Our results demonstrate a feasible and reproducible method of immune monitoring using CT-compatible needle biopsies from tumor tissue, thereby paving the way for sophisticated translational studies during tumor biological therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUME : Valganciclovir (Valcyte®) is an orally administered ester prodrug of the standard anticytomegalovirus (CMV) drug ganciclovir. This drug enabled an important reduction of the burden of CMV morbidity and mortality in solid organ transplant recipients. Prevention of CMV infection and treatment of CMV disease requires drug administration during many weeks. Oral drug administration is therefore convenient. Valganciclovir has been developed to overcome the poor oral availability of ganciclovir, which limits its concentration exposure after oral administration and thus its efficacy. This prodrug crosses efficiently the intestinal barrier, is then hydrolyzed into ganciclovir, providing exposure similar to intravenous ganciclovir. Valganciclovir is now preferred for the prophylaxis and treatment of CMV infection in solid organ transplant recipients. Nevertheless, adequate dosage adjustment is necessary to optimize its use, avoiding either insufficient or exaggerate exposure related to differences in its pharmacokinetic profile between patients. The main goal of this thesis was to better describe the pharmacokinetic and pharmacodynamic profile of valganciclovir in solid organ transplant recipients, to assess their reproducibility and their predictability, and thus to evaluate the current recommendations for valganciclovir dosage adjustment and the potential contribution of routine therapeutic drug monitoring (TDM) to patients' management. A total of 437 ganciclovir plasma concentration data from 65 transplant patients (41 kidney, 12 lung, 10 heart and 2 liver recipients, 58 under oral valganciclovir prophylaxis, 8 under oral valganciclovir treatment and 2 under intravenous ganciclovir) were measured using a validated chromatographic method (HPLC) developed for this study. The results were analyzed by non-linear mixed effect modeling (NONMEM). A two-compartment model with first-order absorption appropriately described the data. Systemic clearance was markedly influenced by GFR, with further differences between graft types and sex (CL/GFR = 1.7 in kidney, 0.9 in heart and 1.2 in lung and liver recipients) with interpatient variability (CV%) of 26% and interoccasion variability of 12%. Body weight and sex influenced central volume of distribution (V1 = 0.34 l/kg in males and 0.27 l/kg in females) with an interpatient variability of 20%. Residual intrapatient variability was 21 %. No significant drug interaction influenced GCV disposition. VGC prophylactic efficacy and tolerability were good, without detectable dependence on GCV profile. In conclusion, this analysis highlights the importance of thorough adjustment of VGC dosage to renal function and body weight. Considering the good predictability and reproducibility of GCV profile after oral VGC in solid organ transplant recipients, routine TDM does not appear to be clinically indicated. However, GCV plasma measurement may still be helpful in specific clinical situations such as documentation of appropriate exposure in patients with potentially compromised absorption, or lack of response to CMV disease treatment, or under renal replacement therapy. RESUME : Le valganciclovir (Valcyte®) est un promédicament oral du ganciclovir qui est un anti-infectieux de référence contre les infections à cytomegalovirus (CMV). Cet antiviral a permis de réduire les effets délétères de cette infection jusqu'ici responsable d'une importante morbidité et mortalité chez les transplantés d'organe. La prévention et le traitement de l'infection à CMV sont donc nécessaires mais requièrent l'administration d'un agent antiviral sur une longue période. Un médicament administré par voie orale représente donc un avantage évident. Le valganciclovir a été développé dans le but d'améliorer la faible absorption orale du ganciclovir, et donc son efficacité. Cet ester valylique du ganciclovir traverse plus facilement la barrière gastro-intestinale, puis est hydrolysé en ganciclovir dans la circulation sanguine, produisant une exposition comparable à celle d'une perfusion intraveineuse de ganciclovir. De ce fait, le valganciclovir est devenu largement utilisé pour la prophylaxie mais aussi le traitement de l'infection à CMV. Néanmoins une utilisation optimale de ce nouveau médicament nécessite de bonnes connaissances sur son profil pharmacocinétique afin d'établir un schéma de dose adapté pour éviter tant une surexposition qu'une sous-exposition résultant des différences d'élimination entre les patients. Le but de cette thèse a été d'étudier le profil pharmacocinétique et pharmacodynamique du valganciclovir chez les transplantés d'organe ainsi que sa reproductibilité et sa prédictibilité. Il s'agissait d'apprécier de manière critique le schéma actuellement recommandé pour l'adaptation des doses de valganciclovir, mais aussi la contribution éventuelle d'un suivi des concentrations sanguines en routine. Un total de 437 taux sanguins de ganciclovir ont été mesurés, provenant de 65 patients transplantés d'organe (41 rénaux, 12 pulmonaires, 10 cardiaques et 2 hépatiques, 58 sous une prophylaxie orale de valganciclovir, 8 sous un traitement de valganciclovir et 2 sous un traitement intraveineux). Une méthode de chromatographie liquide à haute performance a été développée et validée pour cette étude. Les résultats ont été ensuite analysés par modélisation non linéaire à effets mixtes (NONMEM). Un modèle à deux compartiments avec absorption de premier ordre a permis de décrire les données. La clairance systémique était principalement influencée par le débit de filtration glomérulaire (GFR), avec une différence entre les types de greffe et les sexes (CL/GFR = 1.7 chez les greffés rénaux, 0.9 pour les greffés cardiaques et 1.2 pour le groupe des greffés pulmonaires et hépatiques) avec un variabilité inter-individuelle de 26% (CV%) et une variabilité inter-occasion de 12%. Le poids corporel ainsi que le sexe avaient une influence sur le volume central de distribution (V1 = 0.34 l/kg chez les hommes et 0.27 l/kg chez les femmes) avec une variabilité inter-individuelle de 20%. La variabilité intra-individuelle résiduelle était de 21 %. Aucune interaction médicamenteuse n'a montré d'influence sur le profil du ganciclovir. La prophylaxie avec le valganciclovir s'est révélée efficace et bien tolérée. En conclusion, cette analyse souligne l'importance d'une adaptation de la dose du valganciclovir à la fonction rénale et au poids du patient. Au vu de la bonne reproductibilité et prédictibilité du profil pharmacocinétique du ganciclovir chez les patients transplantés recevant du valganciclovir, un suivi des concentrations sanguines en routine ne semble pas cliniquement indiqué. Néanmoins, la mesure des taux plasmatiques de ganciclovir peut être utile dans certaines situations particulières, comme la vérification d'une exposition appropriée chez des patients susceptibles d'absorption insuffisante, ou ne répondant pas au traitement d'une infection à CMV ou encore sous épuration extra-rénale. RESUME LARGE PUBLIC : Le valganciclovir est un précurseur capable de libérer du ganciclovir, récemment développé pour améliorer la faible absorption orale de ce dernier. Une fois le valganciclovir absorbé, le ganciclovir libéré dans la circulation sanguine devient efficace contre les infections à cytomégalovirus. Ce virus largement répandu est responsable de maladies insidieuses et parfois graves chez les personnes présentant une baisse des défenses immunitaires, comme les greffés d'organe recevant un traitement anti-rejet. Le ganciclovir est administré pendant plusieurs mois consécutifs soit pour prévenir une infection après la transplantation, soit pour traiter une infection déclarée. La facilité d'administration du valganciclovir par voie orale représente un avantage sur une administration du ganciclovir par perfusion, qui nécessite une hospitalisation. Toutefois, la voie orale peut être une source supplémentaire de variabilité chez les patients, avec un impact potentiel sur l'efficacité ou la toxicité du médicament. Le but de cette étude a été - de décrire le devenir de ce médicament dans le corps humain (dont l'étude relève de la discipline de la pharmacocinétique) - de définir les facteurs cliniques pouvant expliquer les différences de concentration sanguine observées entre les patients sous une posologie donnée - d'explorer les relations entre les concentrations du médicament dans le sang et son efficacité ou la survenue d'effets indésirables (dont l'étude relève de la discipline de la pharmacodynamie). Cette étude a nécessité le développement et la validation, d'une méthode d'analyse pour mesurer la concentration sanguine du ganciclovir, puis son application à 437 échantillons provenant de 65 patients transplantés d'organe solide (41 rénaux, 12 pulmonaires, 10 cardiaques et 2 hépatiques) recevant du valganciclovir. Les résultats des mesures effectuées ont été analysés à l'aide d'un outil mathématique afin d'élaborer un modèle du devenir du médicament dans le sang chez chaque patient et à chaque occasion. Cette étude a permis d'évaluer chez des patients recevant le valganciclovir, la vitesse à laquelle l'organisme absorbe, distribue, puis élimine le médicament. La vitesse d'élimination dépendait étroitement de la fonction rénale, du type de greffe et du sexe alors que la distribution dépendait du poids et du sexe du patient. La variabilité non expliquée par ces facteurs cliniques était modérée et vraisemblablement sans conséquence clinique évidente soit sur l'efficacité ou la tolérance, qui se révèlent très satisfaisantes chez les patients de l'étude. Les observations n'ont pas révélé de relation entre les concentrations de médicament et l'efficacité thérapeutique ou la survenue d'effets indésirables, confirmant que les doses relativement faibles utilisées dans notre collectif de patients suffisaient à produire une exposition reproductible à des concentrations adéquates. En conclusion, le profil (et par conséquent l'absorption) du valganciclovir chez les patients transplantés semble bien prédictible après une adaptation de la dose à la fonction rénale et au poids du patient. Un contrôle systématique des concentrations sanguines n'est probablement pas indiqué en routine, mais cette mesure peut présenter un intérêt dans certaines conditions particulières.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Gadolinium-enhanced pulmonary magnetic resonance angiography (MRA) can be an option in patients with a history of previous adverse reaction to iodinated contrast material and renal insufficiency. Radiation is also avoided. The aim of this study is to prospectively compare the diagnostic value of MRA with that of a diagnostic strategy, taking into account catheter angiography, computed tomography angiography (CTA), and lung scintigraphy [ventilation-perfusion (VQ)]. MATERIAL AND METHODS: Magnetic resonance angiography was done in 48 patients with clinically suspected pulmonary embolism (PE) using fast gradient echo coronal acquisition with gadolinium. Interpretation was done with native coronal images and multiplanar maximum intensity projection reconstructions. Results were compared to catheter angiography (n=15), CTA (n=34), VQ (n=45), as well as 6-12 months clinical follow-ups, according to a sequenced reference tree. RESULTS: The final diagnosis of PE was retained in 11 patients (23%). There were two false negatives and no false positive results with MRA. Computed tomography angiography resulted in no false negatives or false positives. Magnetic resonance angiography had a sensitivity of 82% and a specificity of 100%. CONCLUSION: In our study, pulmonary MRA had a sensitivity of 82% and a specificity of 100% for the diagnosis of PE, with slightly less sensitivity than CTA. In the diagnostic algorithm of PE, pulmonary MRA should be considered as an alternative to CTA when iodine contrast injection or radiation is a significant matter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last five years, Deep Brain Stimulation (DBS) has become the most popular and effective surgical technique for the treatent of Parkinson's disease (PD). The Subthalamic Nucleus (STN) is the usual target involved when applying DBS. Unfortunately, the STN is in general not visible in common medical imaging modalities. Therefore, atlas-based segmentation is commonly considered to locate it in the images. In this paper, we propose a scheme that allows both, to perform a comparison between different registration algorithms and to evaluate their ability to locate the STN automatically. Using this scheme we can evaluate the expert variability against the error of the algorithms and we demonstrate that automatic STN location is possible and as accurate as the methods currently used.