213 resultados para Radial glia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

NlmCategory="UNASSIGNED">A version of cascaded systems analysis was developed specifically with the aim of studying quantum noise propagation in x-ray detectors. Signal and quantum noise propagation was then modelled in four types of x-ray detectors used for digital mammography: four flat panel systems, one computed radiography and one slot-scan silicon wafer based photon counting device. As required inputs to the model, the two dimensional (2D) modulation transfer function (MTF), noise power spectra (NPS) and detective quantum efficiency (DQE) were measured for six mammography systems that utilized these different detectors. A new method to reconstruct anisotropic 2D presampling MTF matrices from 1D radial MTFs measured along different angular directions across the detector is described; an image of a sharp, circular disc was used for this purpose. The effective pixel fill factor for the FP systems was determined from the axial 1D presampling MTFs measured with a square sharp edge along the two orthogonal directions of the pixel lattice. Expectation MTFs were then calculated by averaging the radial MTFs over all possible phases and the 2D EMTF formed with the same reconstruction technique used for the 2D presampling MTF. The quantum NPS was then established by noise decomposition from homogenous images acquired as a function of detector air kerma. This was further decomposed into the correlated and uncorrelated quantum components by fitting the radially averaged quantum NPS with the radially averaged EMTF(2). This whole procedure allowed a detailed analysis of the influence of aliasing, signal and noise decorrelation, x-ray capture efficiency and global secondary gain on NPS and detector DQE. The influence of noise statistics, pixel fill factor and additional electronic and fixed pattern noises on the DQE was also studied. The 2D cascaded model and decompositions performed on the acquired images also enlightened the observed quantum NPS and DQE anisotropy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Focal epilepsy is increasingly recognized as the result of an altered brain network, both on the structural and functional levels and the characterization of these widespread brain alterations is crucial for our understanding of the clinical manifestation of seizure and cognitive deficits as well as for the management of candidates to epilepsy surgery. Tractography based on Diffusion Tensor Imaging allows non-invasive mapping of white matter tracts in vivo. Recently, diffusion spectrum imaging (DSI), based on an increased number of diffusion directions and intensities, has improved the sensitivity of tractography, notably with respect to the problem of fiber crossing and recent developments allow acquisition times compatible with clinical application. We used DSI and parcellation of the gray matter in regions of interest to build whole-brain connectivity matrices describing the mutual connections between cortical and subcortical regions in patients with focal epilepsy and healthy controls. In addition, the high angular and radial resolution of DSI allowed us to evaluate also some of the biophysical compartment models, to better understand the cause of the changes in diffusion anisotropy. Global connectivity, hub architecture and regional connectivity patterns were altered in TLE patients and showed different characteristics in RTLE vs LTLE with stronger abnormalities in RTLE. The microstructural analysis suggested that disturbed axonal density contributed more than fiber orientation to the connectivity changes affecting the temporal lobes whereas fiber orientation changes were more involved in extratemporal lobe changes. Our study provides further structural evidence that RTLE and LTLE are not symmetrical entities and DSI-based imaging could help investigate the microstructural correlate of these imaging abnormalities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction La stratégie de reperfusion coronarienne par voie percutanée (PCI: percutaneous coronary intervention) est considérée comme étant la méthode de choix dans la prise en charge urgente des STEMI(H). Actuellement, les deux accès artériels principaux pour les PCI sont l'artère fémorale et l'artère radiale. La voie radiale est préconisée en première intention par les guidelines actuelles car elle serait associée à moins de complications hémorragiques. Objectif L'objectif de cette étude était de comparer la voie d'abord radiale à la voie fémorale, chez les patients admis pour un STEMI, en analysant le succès de la procédure de revascularisation, l'évolution clinique et les complications. Méthode Il s'agit d'une étude observationnelle, comprenant 268 patients admis au CHUV entre le 1er janvier et le 31 décembre 2013, avec le diagnostic de STEMI. Le choix de la voie d'accès artériel (fémorale ou radiale) était laissé au cardiologue interventionnel, sans randomisation. Les patients ont été séparés en 2 groupes, selon la voie d'abord vasculaire choisie au début de la procédure de revascularisation (intention to treat). Les endpoints primaires étaient les saignements majeurs (≥ 3 selon BARC)(A), et le door to balloon time(B). Les endpoints secondaires étaient les MACE(C), les saignements mineurs(A), le taux succès des procédures(D), le temps de fluoroscopie, la quantité de produit de contraste, et le taux de crossover(E) Résultats 268 patients en STEMI ont été inclus dans cette étude, pour un geste de revascularisation en urgence. La moyenne d'âge était de 64.3 ans, avec 73.1% d'hommes. 3 cas de saignements majeurs(A) ont lieu avec la voie radiale (3.4%), et 10 avec la voie fémorale (5.6%), p=0.44. Le door to balloon time ne diffère pas de manière significative selon la voie d'accès employée : 42 min (34-57) pour le groupe radial, et 48 min (31-61) pour le groupe fémoral, p=0.09. Les taux de MACE étaient de 8.0% avec la voie radiale, et de 6.7% avec la voie fémorale, p=0.7. Le taux de crossover était de 4.5% avec la voie radiale, et 0.6% avec la voie fémorale, p=0.02. Le temps de fluoroscopie était de 7min 28sec (5min 9 sec - 12min 25) pour la voie fémorale, contre 12min 22sec (9min 30 sec - 16min 19sec) pour la voie radiale, p < 0.05. La quantité de produit de contraste nécessaire était de 120 ml (100-160) pour le groupe fémoral, et de 170 ml (140-210) pour le groupe radial, p < 0.05. Le taux de succès était comparable entres les 2 groupes : 97.7% pour le groupe radial et 96.0% pour le groupe fémoral, p=0.47. 5.7% des patients du groupe radial sont décédés, contre 5.7% du groupe fémoral, p=0.97. Conclusion Notre étude démontre que la prise en charge d'un STEMI par voie radiale est possible, puisqu'elle n'allonge pas le « door to balloon time », qu'elle n'augmente pas le taux de MACE ni les saignements majeurs, que soit au point de ponction ou non. Par contre la voie radiale augmente la quantité de produit de contraste nécessaire, et allonge le temps de fluoroscopie de manière non négligeable. De futures études permettront peut-être de mieux définir les groupes de patients qui pourraient bénéficier le plus d'une approche radiale.