213 resultados para Ex vivo perfusion


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background:  Study in vivo characteristics of a polymethylmethacrylate (PMMA) implant compared to the standard cylindrical collagen implant for deep sclerectomy (DS). Design:  Six-month comparative study. Samples:  Twenty eyes of ten rabbits. Methods:  Eyes were randomized to have DS with PMMA implant in one eye and collagen implant in the opposite eye. The growth of the new subconjunctival drainage vessels was assessed by combined fluorescein and indocyanin green anterior segment angiography; intrascleral and subconjunctival blebs were imaged by ultrasound biomicroscopy (UBM). At six months, outflow facility (C) was measured by anterior chamber perfusion and portions of one side of the DS were compared to portions on the 180° opposite side and native sclera on histology. Results:  The mean IOP preoperatively and at one, four, twelve, and twenty-four weeks was comparable in both groups (P > 0.1). UBM showed a statistically insignificant quicker regression of the subconjunctival bleb as well as a durable intrascleral lake in the PMMA group (P > 0.05). New drainage vessels were initially observed one month after surgery; they were more numerous in the PMMA group on angiographic and histological findings at 6 months (P < 0.05). The mean C increased significantly after surgery compared to preoperative values (P < 0.05) and no difference was observed between the implants (0.24 ± 0.06 µl/min/mmHg [PMMA] and 0.23 ± 0.07 µl/min/mmHg [collagen implant]) (P = 0.39). Conclusions:  Deep sclerectomy performed with PMMA or collagen implants showed similar IOP lowering effects, outflow facility increase, and degree of inflammatory reaction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Il s'agit de comparer in vivo la sécurité et l'efficacité d'un implant en polyméthylméthacrylate (PMMA) avec un implant standard en collagène dans la sclérectomie profonde (SP) sur une durée de six mois. La population étudiée comprend vingt lapins, chaque lapin étant randomisé pour une SP avec implant en PMMA dans un oeil et implant de collagène dans l'autre oeil. Plusieurs éléments ont été pris en compte dans la comparaison : - la mesure de la pression intraoculaire - l'évolution de l'espace de drainage intrascléral et de la bulle de filtration sous-conjonctivale, suivie par ultrasonographic biomicroscopique (UBM) - la croissance de nouveaux vaisseaux de drainage sous-conjonctivaux, croissance quantifiée par angiographie du segment antérieur à la fluorescéine combinée au vert d'indocyanine - la facilité à l'écoulement de l'humeur aqueuse (C), mesurée à six mois par cannulation-perfusion de la chambre antérieur - la sclère au site de SP, histologiquement comparée à la sclère native opposée à 180°, également à six mois La pression intraoculaire moyenne préopératoire à une, quatre, douze et 24 semaines postopératoires est comparable dans les deux groupes (P>0.1). L'UBM montre une régression légèrement plus rapide (statistiquement non significative) de la bulle de filtration sous-conjonctivale et la persistance d'un espace de drainage intrascléral dans le groupe PMMA (P>0.05). De nouveaux vaisseaux de drainage sont observés à un mois de la chirurgie ; à six mois, ces vaisseaux sont plus nombreux dans le groupe PMMA, tant sur l'analyse angiographique que sur l'analyse histologique (P>0.05). La facilité moyenne à l'écoulement de l'humeur aqueuse est significativement plus élevées à six mois dans les deux groupes par rapport aux valeurs préopératoires (P>0.05), sans qu'il n'y ait de différence entre les deux implants (0.24 ± 0.06 μΙ/min/mmHg [PMMA] et 0.23 ± 0.07 μΙ/min/mmHg [implant en collagène]) (Ρ = 0.39). Cette étude a pu démontrer que la sclérectomie profonde avec implant en collagène ou en PMMA donne des résultats similaires en terme de diminution de l'IOP et d'augmentation de la facilité à l'écoulement de l'humeur aqueuse, sans différence sur le plan des réactions inflammatoires post-intervention.