223 resultados para Digital protection
Resumo:
Manufactured nanoparticles are introduced into industrial processes, but they are suspected to cause similar negative health effects as ambient particles. The poor knowledge about the scale of this introduction did not allow global risk analysis so far. In 2006 a targeted telephone survey among Swiss companies (1) showed the usage of nanoparticles in a few selected companies but did not provide data to extrapolate on the totality of the Swiss workforce. To gain this kind of information a layered representative questionnaire survey among 1'626 Swiss companies was conducted in 2007. Data was collected about the number of potentially exposed persons in the companies and their protection strategy. The response rate was 58.3%. An expected number of 586 companies (95%−confidence interval 145 to 1'027) was shown by this study to use nanoparticles in Switzerland. Estimated 1'309 (1'073 to 1'545) workers do their job in the same room as a nanoparticle application. Personal protection was shown to be the predominant type of protection means. Companies starting productions with nanomaterials need to consider incorporating protection measures into the plans. This will not only benefit the workers' health, but will also likely increase the competitiveness of the companies. Technical and organisational protection means are not only more cost−effective on the long term, but are also easier to control. Guidelines may have to be designed specifically for different industrial applications, including fields outside nanotechnology, and adapted to all sizes of companies.
Resumo:
Previous studies have associated activating Killer cell Immunoglobulin-like Receptor (KIR) genes with protection from cytomegalovirus (CMV) replication after organ transplantation. Whether KIR-associated protection is operating in the context of primary infection, re-activation, or both, remains unknown. Here we correlated KIR genotype and CMV serostatus at the time of transplantation with rates of CMV viremia in 517 heart (n=57), kidney (n=223), liver (n=165) or lung (n=72) allograft recipients reported to the Swiss Transplant Cohort Study. Across the entire cohort we found B haplotypes-which in contrast to A haplotypes may contain multiple activating KIR genes-to be protective in the most immunosuppressed patients (receiving anti-thymocyte globulin induction and intensive maintenance immunosuppression) (hazard ratio after adjustment for covariates 0.46, 95% confidence interval 0.29-0.75, P=0.002). Notably, a significant protection was detected only in recipients who were CMV-seropositive at the time of transplantation (HR 0.45, 95% CI 0.26-0.77, P=0.004), but not in CMV seronegative recipients (HR 0.59, 95% CI 0.22-1.53, P=0.28). These data indicate a prominent role for KIR-and presumably natural killer (NK) cells-in the control of CMV replication in CMV seropositive organ transplant recipients treated with intense immunosuppression.
Resumo:
Objectives: The purpose of this study was to analyze the debris captured in the distal protection filters used during carotid artery stenting (CAS). Background: CAS is an option available to high-risk patients requiring revascularization. Filters are suggested for optimal stroke prevention during CAS. Methods: From May 2005 to June 2007, filters from 59 asymptomatic patients who underwent CAS were collected and sent to a specialized laboratory for light-microscope and histological analysis. Peri- and postprocedural outcomes were assessed during 1-year follow-up. Results: On the basis of biomedical imaging of the filter debris, the captured material could not be identified as embolized particles from the carotid plaque. On histological analysis the debris consisted mainly of red blood cell aggregates and/ or platelets, occasionally accompanied by granulocytes. We found no consistent histological evidence of embolized particles originating from atherosclerotic plaques. Post-procedure, three neurological events were reported: two (3.4%) transient ischemic attacks (TIA) and one (1.7%) ipsilateral minor stroke. Conclusion: The filters used during CAS in asymptomatic patients planned for cardiac surgery often remained empty. These findings may be explained by assuming that asymptomatic patients feature a different atherosclerotic plaque composition or stabilization through antiplatelet medication. Larger, randomized trials are clearly warranted, especially in the asymptomatic population. © 2012 Wiley Periodicals, Inc.
Resumo:
Le scandale de l'amiante, l'épidémie de suicides au travail ou bien encore le "karôshi" sont autant de faits qui invitent à une réflexion renouvelée sur les conditions de travail. Cette thèse part d'une volonté de revisiter, dans un monde professionnel bouleversé par les progrès constants de la technique et les pressions économiques, les liens entre santé et sécurité, telles que visées aux art. 328 CO, 6 LTr et 82 LAA. Il s'agit d'examiner l'articulation entre ces dispositions, sur la base d'une analyse historique et de l'apport actuel du système légal, et la pertinence de repenser celui-ci. En effet, le pluralisme des sources en la matière, hétérogènes de par leur nature (de droit public ou privé) et/ou de par leur objet (la santé ou la sécurité), et le manque d'harmonie entre elles ne sont pas sans créer difficultés d'application et doubles emplois. La présente thèse commence par quelques repères chronologiques sur la mise en place progressive et pragmatique de la législation sociale suisse. Suit un survol des lois protectrices et autres normativités extra-juridiques, qui laisse conclure à un foisonnement et à une hétérogénéité des sources applicables. Puis, les trois dispositions générales topiques, à savoir les articles 328 CO, 6 LTr et 82 LAA, font successivement l'objet d'un examen détaillé, en vue d'évaluer leur bien-fondé respectif et la pertinence d'une approche compartimentée de la santé et sécurité au travail. Et donc de conclure par une réflexion sur l'intérêt d'un changement, notamment par la suppression du dualisme LTr / LAA.
Resumo:
Assessment of image quality for digital x-ray mammography systems used in European screening programs relies mainly on contrast-detail CDMAM phantom scoring and requires the acquisition and analysis of many images in order to reduce variability in threshold detectability. Part II of this study proposes an alternative method based on the detectability index (d') calculated for a non-prewhitened model observer with an eye filter (NPWE). The detectability index was calculated from the normalized noise power spectrum and image contrast, both measured from an image of a 5 cm poly(methyl methacrylate) phantom containing a 0.2 mm thick aluminium square, and the pre-sampling modulation transfer function. This was performed as a function of air kerma at the detector for 11 different digital mammography systems. These calculated d' values were compared against threshold gold thickness (T) results measured with the CDMAM test object and against derived theoretical relationships. A simple relationship was found between T and d', as a function of detector air kerma; a linear relationship was found between d' and contrast-to-noise ratio. The values of threshold thickness used to specify acceptable performance in the European Guidelines for 0.10 and 0.25 mm diameter discs were equivalent to threshold calculated detectability indices of 1.05 and 6.30, respectively. The NPWE method is a validated alternative to CDMAM scoring for use in the image quality specification, quality control and optimization of digital x-ray systems for screening mammography.
Resumo:
PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.
Resumo:
Turtle Mountain in Alberta, Canada has become an important field laboratory for testing different techniques related to the characterization and monitoring of large slope mass movements as the stability of large portions of the eastern face of the mountain is still questionable. In order to better quantify the volumes potentially unstable and the most probable failure mechanisms and potential consequences, structural analysis and runout modeling were preformed. The structural features of the eastern face were investigated using a high resolution digital elevation model (HRDEM). According to displacement datasets and structural observations, potential failure mechanisms affecting different portions of the mountain have been assessed. The volumes of the different potentially unstable blocks have been calculated using the Sloping Local Base Level (SLBL) method. Based on the volume estimation, two and three dimensional dynamic runout analyses have been performed. Calibration of this analysis is based on the experience from the adjacent Frank Slide and other similar rock avalanches. The results will be used to improve the contingency plans within the hazard area.