274 resultados para Ct Scans


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Patients with symptoms of semicircular canal dehiscence often undergo both CT and MR imaging. We assessed whether FIESTA can replace temporal bone CT in evaluating patients for SC dehiscence. MATERIALS AND METHODS: We retrospectively reviewed 112 consecutive patients (224 ears) with vestibulocochlear symptoms who underwent concurrent MR imaging and CT of the temporal bones between 2007 and 2009. MR imaging protocol included a FIESTA sequence covering the temporal bone (axial 0.8-mm section thickness, 0.4-mm spacing, coronal/oblique reformations; 41 patients at 1.5T, 71 patients at 3T). CT was performed on a 64-row multidetector row scanner (0.625-mm axial acquisition, with coronal/oblique reformations). Both ears of each patient were evaluated for dehiscence of the superior and posterior semicircular canals in consensual fashion by 2 neuroradiologists. Analysis of the FIESTA sequence and reformations was performed first for the MR imaging evaluation. CT evaluation was performed at least 2 weeks after the MR imaging review, resulting in a blinded comparison of CT with MR imaging. CT was used as the reference standard to evaluate the MR imaging results. RESULTS: For SSC dehiscence, MR imaging sensitivity was 100%, specificity was 96.5%, positive predictive value was 61.1%, and negative predictive value was 100% in comparison with CT. For PSC dehiscence, MR imaging sensitivity was 100%, specificity was 99.1%, positive predictive value was 33.3%, and negative predictive value was 100% in comparison with CT. CONCLUSIONS: MR imaging, with a sensitivity and negative predictive value of 100%, conclusively excludes SSC or PSC dehiscence. Negative findings on MR imaging preclude the need for CT to detect SC dehiscence. Only patients with positive findings on MR imaging should undergo CT evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the technical quality and the diagnostic performance of a protocol with use of low volumes of contrast medium (25 mL) at 64-detector spiral computed tomography (CT) in the diagnosis and management of adult, nontraumatic subarachnoid hemorrhage (SAH). MATERIALS AND METHODS: This study was performed outside the United States and was approved by the institutional review board. Intracranial CT angiography was performed in 73 consecutive patients with nontraumatic SAH diagnosed at nonenhanced CT. Image quality was evaluated by two observers using two criteria: degree of arterial enhancement and venous contamination. The two independent readers evaluated diagnostic performance (lesion detection and correct therapeutic decision-making process) by using rotational angiographic findings as the standard of reference. Sensitivity, specificity, and positive and negative predictive values were calculated for patients who underwent CT angiography and three-dimensional rotational angiography. The intraclass correlation coefficient was calculated to assess interobserver concordance concerning aneurysm measurements and therapeutic management. RESULTS: All aneurysms were detected, either ruptured or unruptured. Arterial opacification was excellent in 62 cases (85%), and venous contamination was absent or minor in 61 cases (84%). In 95% of cases, CT angiographic findings allowed optimal therapeutic management. The intraclass correlation coefficient ranged between 0.93 and 0.95, indicating excellent interobserver agreement. CONCLUSION: With only 25 mL of iodinated contrast medium focused on the arterial phase, 64-detector CT angiography allowed satisfactory diagnostic and therapeutic management of nontraumatic SAH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The goal of this study was to present the pathological and radiological patterns of "vulnerable" atherosclerotic plaques in cases of sudden cardiac death. Method. This retrospective study was performed on forensic cases for which the cause of death was attributed to coronary artery disease. A complete autopsy was performed in all cases, along with either post-mortem CT-angiography, toxicological analyses and/or biochemistry. Results. 89 cases were selected (mean age 55±11.6 years; 75 men and 14 women). In 96.6% of cases a CT-angiography was performed. Acute coronary lesions were found in 60 cases (mean age 53±11.1 years), which included plaque erosion in 26 cases (mean age 47±8.3 years) and ruptures or intraplaque hemorrhage in 33 cases (mean age 58±10.4 years). Erosions were most frequently found in the left ascending artery (61.5 %), while only 36% of ruptures were observed in this artery. Chronic coronary pathology was described in 30 cases (mean age 58±10.4 years). CT-angiographies performed prior to the autopsy enabled an initial evaluation of coronary artery perfusion. Conclusion. In the face of decreasing clinical autopsy rates, postmortem studies on forensic autopsies, including modern radiological examinations, allow for a more thorough understanding of the clinical picture of disease which can result in sudden cardiac death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain perfusion can be assessed by CT and MR. For CT, two major techniquesare used. First, Xenon CT is an equilibrium technique based on a freely diffusibletracer. First pass of iodinated contrast injected intravenously is a second method,more widely available. Both methods are proven to be robust and quantitative,thanks to the linear relationship between contrast concentration and x-ray attenuation.For the CT methods, concern regarding x-ray doses delivered to the patientsneed to be addressed. MR is also able to assess brain perfusion using the firstpass of gadolinium based contrast agent injected intravenously. This method hasto be considered as a semi-quantitative because of the non linear relationshipbetween contrast concentration and MR signal changes. Arterial spin labelingis another MR method assessing brain perfusion without injection of contrast. Insuch case, the blood flow in the carotids is magnetically labelled by an externalradiofrequency pulse and observed during its first pass through the brain. Eachof this various CT and MR techniques have advantages and limits that will be illustratedand summarised.Learning Objectives:1. To understand and compare the different techniques for brain perfusionimaging.2. To learn about the methods of acquisition and post-processing of brainperfusion by first pass of contrast agent for CT and MR.3. To learn about non contrast MR methods (arterial spin labelling).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To identify patients with spontaneous subarachnoid hemorrhage for whom CT angiography alone can exclude ruptured aneurysms. METHODS: An observational retrospective review was carried out of all consecutive patients with non-traumatic subarachnoid hemorrhage who underwent both CT angiography and catheter angiography to exclude an aneurysm. CT angiography negative cases (no aneurysm) were classified according to their CT hemorrhage pattern as "aneurismal", "perimesencephalic" or as "no-hemorrhage." RESULTS: Two hundred and forty-one patients were included. A CT angiography aneurysm detection sensitivity and specificity of 96.4% and 96.0% were observed. All 35 cases of perimesencephalic or no-hemorrhage out of 78 CT angiography negatives also had negative angiography findings. CONCLUSIONS: CT angiography is self-reliant to exclude ruptured aneurysms when either a perimesencephalic hemorrhage or no-hemorrhage pattern is identified on the CT within a week of symptom onset.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed at assessing the doses delivered in Switzerland to paediatric patients during computed tomography (CT) examinations of the brain, chest and abdomen, and at establishing diagnostic reference levels (DRLs) for various age groups. Forms were sent to the ten centres performing CT on children, addressing the demographics, the indication and the scanning parameters: number of series, kilovoltage, tube current, rotation time, reconstruction slice thickness and pitch, volume CT dose index (CTDI(vol)) and dose length product (DLP). Per age group, the proposed DRLs for brain, chest and abdomen are, respectively, in terms of CTDI(vol): 20, 30, 40, 60 mGy; 5, 8, 10, 12 mGy; 7, 9, 13, 16 mGy; and in terms of DLP: 270, 420, 560, 1,000 mGy cm; 110, 200, 220, 460 mGy cm; 130, 300, 380, 500 mGy cm. An optimisation process should be initiated to reduce the spread in dose recorded in this study. A major element of this process should be the use of DRLs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positron emission computed tomography (PET) is a functional, noninvasive method for imaging regional metabolic processes that is nowadays most often combined to morphological imaging with computed tomography (CT). Its use is based on the well-founded assumption that metabolic changes occur earlier in tumors than morphologic changes, adding another dimension to imaging. This article will review the established and investigational indications and radiopharmaceuticals for PET/CT imaging for prostate cancer, bladder cancer and testicular cancer, before presenting upcoming applications in radiation therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The Advisa MRI system is designed to safely undergo magnetic resonance imaging (MRI). Its influence on image quality is not well known. OBJECTIVE: To evaluate cardiac magnetic resonance (CMR) image quality and to characterize myocardial contraction patterns by using the Advisa MRI system. METHODS: In this international trial with 35 participating centers, an Advisa MRI system was implanted in 263 patients. Of those, 177 were randomized to the MRI group and 150 underwent MRI scans at the 9-12-week visit. Left ventricular (LV) and right ventricular (RV) cine long-axis steady-state free precession MR images were graded for quality. Signal loss along the implantable pulse generator and leads was measured. The tagging CMR data quality was assessed as the percentage of trackable tagging points on complementary spatial modulation of magnetization acquisitions (n=16) and segmental circumferential fiber shortening was quantified. RESULTS: Of all cine long-axis steady-state free precession acquisitions, 95% of LV and 98% of RV acquisitions were of diagnostic quality, with 84% and 93%, respectively, being of good or excellent quality. Tagging points were trackable from systole into early diastole (360-648 ms after the R-wave) in all segments. During RV pacing, tagging demonstrated a dyssynchronous contraction pattern, which was not observed in nonpaced (n = 4) and right atrial-paced (n = 8) patients. CONCLUSIONS: In the Advisa MRI study, high-quality CMR images for the assessment of cardiac anatomy and function were obtained in most patients with an implantable pacing system. In addition, this study demonstrated the feasibility of acquiring tagging data to study the LV function during pacing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: 1. To review Ct features suggestive of saprophytic aspergillosis (aspergilloma) and to correlate them with the final pathological results. 2. To illustrate the wide range of differential diagnosis. Methods and materials: The electronic database of our department from 1995 to 2007 revealed CT reports of 48 patients that had been considered very suggestive of aspergilloma. Two radiologists with 6 and 12 years experience in thoracic radiology jointly reviewed the corresponding CT features including ancillary findings and the underlying lung diseases and correlated them with the final pathological diagnosis. Results: Forty patients could be included in the study (12 women, mean age 52), while in 8 patients there was no adequate clinical follow-up. In 17 patients the diagnosis "mycetoma" due to aspergillus fumigatus infection was confirmed, either by surgery, biopsy or bronchoscopy. In 23 patients, differential diagnoses were found, such as cavitating bronchial carcinoma (n = 7), bacterial abscess (n = 3), typical (n = 2) and atypical (n = 2) tuberculosis, as well as inflammatory changes due to mucoviscidosis (n = 1), Wegener's disease (n = 1) or chronic obstructive pulmonary disease (n = 3). Fibromyxoide hamartoma, lung infarction and bronchomucocele were responsible for the typical CT feature in one patient each. Conclusion: 1. The typical CT feature suggesting mycetoma is softtissue proliferation within a pre-existing wall-thickened lung cavity, oten even considered "pathognomonic". However, this diagnosis was finally confirmed by surgery or laboratory findings in less than 50% of patients only. 2. Since differential diagnoses are very large, not only including cavitating lung cancer and tuberculosis, the individual underlying lung disease needs strongly being taken into account often giving the best clue for the correct diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Messages à retenir: Le scanner peut aider au diagnostic et la caractérisation des valvulopathies et des lésions associées (aorte, coronaires). Le scanner est un examen incontournable pour l'évaluation pré-thérapeutique des procédures TAVI (transfémorale ou transapicale). Le scanner peut être utile pour caractériser les insuffisances aortiques. Grâce aux développements récents dans les thérapies peu invasives et au progrès du CT, le rôle du radiologue est redevenu central dans la prise en charge de certaines valvulopathies aortiques. Résumé: Les valvulopathies aortiques sont des maladies fréquentes. Leur exploration repose largement sur l'échocardiographie et sur l'IRM. Les progrès technologiques en scanner cardiaque ont permis à ce dernier d'explorer la valve aortique et ses pathologies. Ce cours est principalement consacré aux méthodes d'acquisition et de traitement des images dédiées à l'exploration de la valve aortique (plan de coupes, planimétrie, scores...). Une attention particulière est réservée aux considérations anatomiques spécifiques à celle-ci (variantes anatomiques). Les indications du scanner cardiaque dans les valvulopathies seront résumées (sténoses, insuffisances, pathologie tumorale et pathologies inflammatoires). Dans la sténose de la valve, outre ses performances diagnostiques, le scanner plus ou moins couplé à l'exploration des vaisseaux périphériques, est devenu une méthode intournable dans le bilan pré-thérapeutique. La connaissance des paramètres à évaluer (taille de l'anneau, position des coronaires, orientation du plan de la valve...) et la standardisation des mesures sont un élément clé pour une prise en charge optimale. Dans les insuffisances aortiques, les méthodes de quantification (planimétrie) peuvent être utilisées pour les caractériser avec des performances comparables à celles obtenues par d'autres techniques.