240 resultados para Carotid arteries
Resumo:
A 46-year-old woman with a severe polyradiculoneuropathy treated with high-dose intravenous immunoglobulin (IVIg) presented an encephalopathy with increased blood flow velocities of the middle cerebral arteries (MCAs) detected by transcranial Doppler (TCD) studies. The similitude between this observation and another case recently reported of a patient suffering from Guillain-Barré syndrome (GBS) and cerebral blood flow abnormalities after IVIg treatment prompted us to investigate the responsibility of the IVIg therapy in the genesis of these blood flow alterations. We studied therefore by TCD 10 consecutive patients who underwent this treatment for different reasons. In 1 case we observed an asymptomatic, spontaneously reversible increase in the blood flow velocities of the MCAs consistent with a vasospasm and occurring 3-10 days after completion of the therapy. Stroke and ischemic encephalopathy have been reported as possible complications of IVIg treatment. In the case under discussion, clinical events appeared shortly after the administration of the IVIg therapy and responded favorably to a treatment with nimodipine. Other etiopathogenic mechanisms, in particular a CNS vasculopathic process related to the GBS itself, have to be considered as well. Further studies, with a larger number of patients, are therefore needed to evaluate the underlying mechanisms of blood flow abnormalities occurring sometimes in GBS patients after IVIg treatment.
Resumo:
BACKGROUND: Atherosclerosis has been assessed in human immunodeficiency virus (HIV)-infected persons by using various methods. Peripheral arterial disease (PAD) has not been evaluated, however. We studied the cross-sectional prevalence of lower limb PAD in an HIV-infected population. METHODS: PAD was assessed using the Edinburgh Claudication Questionnaire and by measuring the systolic ankle-brachial blood pressure index (ABI) at rest and after exercise. Patients with PAD were further evaluated by duplex scan of lower limb arteries. RESULTS: Ninety-two consecutive HIV-infected patients were evaluated (23.9% women; mean age, 49.5 years; 61.9% current smokers). Claudication was reported by 15.2% of the patients. PAD was found in 20.7% of the patients: 9.8% had an abnormal ABI (<0.90) at rest, and 10.9% had normal ABI at rest but a >25% decrease after exercise. Of the patients with PAD, 84.2% were investigated with duplex scan, all of whom had atherosclerotic occlusions or stenoses of the iliac or femoral arteries. Age, diabetes, smoking, and low CD4+ T lymphocyte counts were identified as independent predictors of PAD. CONCLUSIONS: The prevalence of symptomatic and asymptomatic PAD is high in the HIV-infected population and is much higher than expected (prevalence in the general population, approximately 3% at 60 years). This study suggests the presence of an epidemic of PAD approximately 20 years earlier in the HIV-infected than in the general population. Larger epidemiological studies are needed to better define risk factors and to evaluate whether PAD is associated with increased mortality, as it is in the general population.
Resumo:
BACKGROUND: Temporal arteritis is a very serious form of vasculitis. Early treatment is essential to avoid blindness. Surgical biopsy of the temporal artery is the gold standard for the diagnosis, but facial nerve injuries may occur. OBJECTIVE: To describe a simple and safe procedure for temporal artery biopsy. METHODS: Case report. RESULTS: A 62-year-old-woman with presumed temporal arteritis was referred. Precise localization of temporal arteries and its branches was obtained with color duplex ultrasonography. Arterial wall thickening (halo sign) was observed in the affected arterial segments. A frontal branch was precisely localized and infiltrated with 1% lidocaine. About 1 cm was removed for histopathologic examination. Thirty minutes was required to perform this outpatient procedure. The diagnosis of temporal arteritis was confirmed, and the patient was rapidly and successfully treated with prednisone. CONCLUSIONS: Color duplex ultrasonography allows precise localization of temporal arteries and its branches. This echocardiography-guided surgical procedure is easy and safe. Most dermatologic surgeons can perform it.
Resumo:
Purpose: We evaluated the potential for hybrid PET/MRI devices to provide integrated metabolic, functional and anatomic characterisation of patients with suspected coronary artery disease.Methods and Materials: Ten patients (5 with suspected hibernating myocardium and 5 healthy volunteers) performed an imaging study using a hybrid PET/MRI (Philips). Viability assessed by 18F-FDG was performed in diseased patients along with MRI anatomic and functional study and reassessed within 30 minutes by conventional PET/CT. Non-contrast right coronary artery (RCA) targeted and whole heart 3D coronary angio-MRI using ECG-gating and respiratory navigator was performed in healthy volunteers with reconstruction performed using MPR and volume rendering. The extent of metabolic defect (MD) using PET/MRI and PET/CT was compared in patients and coronary territories (LAD, CX, RCA). Assessability of coronary lumen was judged as good, sub-optimal or non-assessable using a 16-segments coronary model.Results: Metabolic assessment was successful in all patients with MD being 19.2% vs 18.3% using PET/MRI and PET/CT, respectively (P=ns). The MD was 10.2%, 6 %, and 3 % vs 9.3%, 6 % and 3 % for LAD, CX and RCA territories, respectively (P= ns). Coronary angio-MRI was successful in all volunteers with 66 coronary segments visualised overall. The RCA was fully visualised in 4/5 volunteers and the left coronary arteries in 4/5 volunteers. Assessability in visualised segments was good, sub-optimal and non-assessable in 88 %, 2 % and 10 %, respectively.Conclusion: Hybrid PET/MRI devices may enable metabolic evaluation comparable to PET/CT with additional value owing to accurate functional and anatomical information including coronary assessment.
Resumo:
PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity.
Resumo:
Instead of standard rigid thoracoscopes, we used a modified gastroscope for video assistance during 12 minimally invasive left internal mammary harvesting. Flexibility and remote control of its last centimeters give to the gastroscope a total freedom of movements, and perfect positioning in every direction. The scope is equipped with cold light, a suction canal and an irrigation canal, which allow for in situ washing without needing to remove it from the thoracic cavity. Thanks to these advantages, vision and lighting are always perfect.
Resumo:
OBJECTIVES: The goal was to test 2 hypotheses: first, that coronary endothelial function can be measured noninvasively and abnormal function detected using clinical 3.0-T magnetic resonance imaging (MRI); and second, that the extent of local coronary artery disease (CAD), in a given patient, is related to the degree of local abnormal coronary endothelial function. BACKGROUND: Abnormal endothelial function mediates the initiation and progression of atherosclerosis and predicts cardiovascular events. However, direct measures of coronary endothelial function have required invasive assessment. METHODS: The MRI was performed in 20 healthy adults and 17 patients with CAD. Cross-sectional coronary area and blood flow were quantified before and during isometric handgrip exercise, an endothelial-dependent stressor. In 10 severe, single-vessel CAD patients, paired endothelial function was measured in the artery with severe stenosis and the contralateral artery with minimal disease. RESULTS: In healthy adults, coronary arteries dilated and flow increased with stress. In CAD patients, coronary artery area and blood flow decreased with stress (both p </= 0.02). In the paired study, coronary artery area and blood flow failed to increase during exercise in the mildly diseased vessel, but both area (p = 0.01) and blood flow (p = 0.02) decreased significantly in the severely diseased, contralateral artery. CONCLUSIONS: Endothelial-dependent coronary artery dilation and increased blood flow in healthy subjects, and their absence in CAD patients, can now be directly visualized and quantified noninvasively. Local coronary endothelial function differs between severely and mildly diseased arteries in a given CAD patient. This novel, safe method may offer new insights regarding the importance of local coronary endothelial function and improved risk stratification in patients at risk for and with known CAD.
Resumo:
OBJECTIVE: Absent or reverse end-diastolic flow (Doppler II/III) in umbilical artery is correlated with poor perinatal outcome, particularly in intrauterine growth restricted (IUGR) fetuses. The optimal timing of delivery is still controversial. We studied the short- and long-term morbidity and mortality among these children associated with our defined management. STUDY DESIGN: Sixty-nine IUGR fetuses with umbilical Doppler II/III were divided into three groups; Group 1, severe early IUGR, no therapeutic intervention (n = 7); Group 2, fetuses with pathological biophysical profile, immediate delivery (n = 35); Group 3, fetuses for which expectant management had been decided (n = 27). RESULTS: In Group 1, stillbirth was observed after a mean delay of 6.3 days. Group 2 delivered at an average of 31.6 weeks and two died in the neonatal period (6%). In Group 3 after a mean delay of 8 days, average gestational age at delivery was 31.7 weeks; two intra uterine and four perinatal deaths were observed (22%). Long-term follow-up revealed no sequelae in 25/31 (81%) and 15/18 (83%), and major handicap occurred in 1 (3%) and 2 patients (11%), respectively, for Groups 2 and 3. CONCLUSION: Fetal mortality was observed in 22% of this high risk group. After a mean period of follow-up of 5 years, 82% of infants showed no sequelae. According to our management, IUGR associated with umbilical Doppler II or III does not show any benefit from an expectant management in term of long-term morbidity.
Resumo:
INTRODUCTION: Cerebrovascular changes are rarely discussed in patients with hemimegalencephaly. These alterations have previously been associated with epileptical activity. CASE: We report the case of a 36-week gestation neonate presenting with total right hemimegalencephaly, as demonstrated by a magnetic resonance imaging (MRI) performed in the first days of life. Perfusion-weighted imaging displayed a clear hypervascularization of the right hemisphere. Diffusion-tensor imaging showed an arrangement of white matter fibers concentrically around the ventricle on the right hemisphere. AngioMRI showed an obvious asymmetry in the size of the middle cerebral arteries, with the right middle cerebral artery being prominent. The baby was free of clinical seizures during his first week of life. An electroencephalogram at that time displayed an asymmetric background activity, but no electrical seizures. CONCLUSION: Perfusion anomalies in hemimegalencephaly may not necessarily be related to epileptical activity, but may be related to vessel alterations.
Resumo:
Although it has been clearly demonstrated that venous thromboembolism is associated with an increased risk of subsequent overt cancer and arterial cardiovascular events in comparison with control populations, whether this association also applies to patients with isolated (ie, without concomitant involvement of the deep vein system) superficial vein thrombosis (SVT) in the legs is unknown. In 737 consecutive patients with isolated SVT not involving the sapheno-femoral junction, we conducted a retrospective investigation to assess the rate of cancer and that of arterial cardiovascular events occurring during follow-up. The event rates were compared with those occurring in 1438 controls having comparable characteristics. Both cases and controls were followed-up for an average period of 26 ± 8 months (range, 3-45). Malignancy was diagnosed in 26 cases (3.5%) and 56 controls (3.9%), leading to a hazard ratio of 0.86 (95% confidence interval, 0.55%-1.35%). Arterial cardiovascular events occurred in 32 cases (4.3%) and 63 controls (4.4%), leading to a hazard ratio of 0.97 (95% confidence interval, 0.63%-1.50%). We conclude that the occurrence of isolated SVT in the legs does not place patients at an increased risk of malignancies or arterial cardiovascular events. Whether this conclusion also applies to patients whose thrombosis involves the sapheno-femoral junction remains to be demonstrated.
Resumo:
To enhance the clinical value of coronary magnetic resonance angiography (MRA), high-relaxivity contrast agents have recently been used at 3T. Here we examine a uniform bilateral shadowing artifact observed along the coronary arteries in MRA images collected using such a contrast agent. Simulations were performed to characterize this artifact, including its origin, to determine how best to mitigate this effect, and to optimize a data acquisition/injection scheme. An intraluminal contrast agent concentration model was used to simulate various acquisition strategies with two profile orders for a slow-infusion of a high-relaxivity contrast agent. Filtering effects from temporally variable weighting in k-space are prominent when a centric, radial (CR) profile order is applied during contrast infusion, resulting in decreased signal enhancement and underestimation of vessel width, while both pre- and postinfusion steady-state acquisitions result in overestimation of the vessel width. Acquisition during the brief postinfusion steady-state produces the greatest signal enhancement and minimizes k-space filtering artifacts.
Resumo:
The acquisition duration of most three-dimensional (3D) coronary magnetic resonance angiography (MRA) techniques is considerably prolonged, thereby precluding breathholding as a mechanism to suppress respiratory motion artifacts. Splitting the acquired 3D volume into multiple subvolumes or slabs serves to shorten individual breathhold duration. Still, problems associated with misregistration due to inconsistent depths of expiration and diaphragmatic drift during sustained respiration remain to be resolved. We propose the combination of an ultrafast 3D coronary MRA imaging sequence with prospective real-time navigator technology, which allows correction of the measured volume position. 3D volume splitting using prospective real-time navigator technology, was successfully applied for 3D coronary MRA in five healthy individuals. An ultrafast 3D interleaved hybrid gradient-echoplanar imaging sequence, including T2Prep for contrast enhancement, was used with the navigator localized at the basal anterior wall of the left ventricle. A 9-cm-thick volume, with in-plane spatial resolution of 1.1 x 2.2 mm, was acquired during five breathholds of 15-sec duration each. Consistently, no evidence of misregistration was observed in the images. Extensive contiguous segments of the left anterior descending coronary artery (48 +/- 18 mm) and the right coronary artery (75 +/- 5 mm) could be visualized. This technique has the potential for screening for anomalous coronary arteries, making it well suited as part of a larger clinical MR examination. In addition, this technique may also be applied as a scout scan, which allows an accurate definition of imaging planes for subsequent high-resolution coronary MRA.
Resumo:
PURPOSE OF REVIEW: To present the practical aspects of transcranial Doppler (TCD) and provide evidence supporting its use for the management of traumatic brain injury (TBI) patients. RECENT FINDINGS: TCD measures systolic, mean, and diastolic cerebral blood flow (CBF) velocities and calculates the pulsatility index from basal intracranial arteries. These variables reflect the brain circulation, provided there is control of potential confounding factors. TCD can be useful in patients with severe TBI to detect low CBF, for example, during intracranial hypertension, and to assess cerebral autoregulation. In the emergency room, TCD might complement brain computed tomography (CT) scan and clinical examination to screen patients at risk for further neurological deterioration after mild-to-moderate TBI. SUMMARY: The diagnostic value of TCD should be incorporated into other findings from multimodal brain monitoring and CT scan to optimize the bedside management of patients with TBI and help guide the choice of appropriate therapies.
Resumo:
Subarachnoid haemorrhage (SAH) is a form of stroke that is associated with substantial morbidity, often as a result of cerebral ischaemia that occurs in the following days. These delayed deficits in blood flow have been traditionally attributed to cerebral vasospasm (the narrowing of large arteries), which can lead to cerebral infarction and poor neurological outcome. Data from recent studies, however, show that treatment of vasospasm in patients with SAH, using targeted medication, does not translate to better neurological outcomes, and argue against vasospasm being the sole cause of the delayed ischaemic complications. Cerebral autoregulation-a mechanism that maintains stability of cerebral blood flow in response to changes in cerebral perfusion pressure-has been reported to fail after SAH, often before vasospasm becomes apparent. Failure of autoregulation, therefore, has been implicated in development of delayed cerebral ischaemia. In this Review, we summarize current knowledge about the clinical effect of disturbed cerebral autoregulation following aneurysmal SAH, with emphasis on development of delayed cerebral ischaemia and clinical outcome, and provide a critical assessment of studies of cerebral autoregulation in SAH with respect to the method of blood-flow measurement. Better understanding of cerebral autoregulation following SAH could reveal mechanisms of blood-flow regulation that could be therapeutically targeted to improve patient outcome.