293 resultados para magnetic marker


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have previously demonstrated that measurement of tissue concentration of the novel secretogranin II-derived peptide EM66 may help to discriminate between benign and malignant pheochromocytomas. The aim of the present study was to characterize EM66 in plasma and urine of healthy volunteers and pheochromocytoma patients, in order to further evaluate the usefulness of this peptide as a circulating marker for the management of the tumors. HPLC analysis of plasma and urine samples demonstrated that the EM66-immunoreactive material coeluted with the recombinant peptide. In healthy volunteers, plasma and urinary EM66 levels were, respectively, 2.6 (1.9-3.7) ng/ml and 2.9 (1.9-4.6) ng/ml. In patients with pheochromocytoma, plasma EM66 levels were 10-fold higher than those of healthy volunteers (26.9 (7.3-44) ng/ml), and returned to normal values after removal of the tumor. In contrast, urinary EM66 levels were not significantly different from those of healthy volunteers (3.2 (2.2-3.9) ng/ml). Measurement of total or free plasma metanephrines and 24 hr urinary metanephrines in our series of patients revealed that these tests, taken separately, are less sensitive than the EM66 determination. Pheochromocytes in primary culture secreted high levels of EM66, suggesting that the chromaffin tumor was actually responsible for the increased plasma peptide concentrations in the patients. These data indicate that EM66 is secreted in the general circulation and that elevated plasma EM66 levels are correlated with the occurrence of pheochromocytoma. Thus, EM66 is a sensitive plasma marker that should be considered as a complementary tool in the management of pheochromocytoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The EuroCMR registry sought to evaluate indications, image quality, safety and impact on patient management of clinical routine CMR in a multi-national European setting. Furthermore, interim analysis of the specific protocols should underscore the prognostic potential of CMR. METHODS: Multi-center registry with consecutive enrolment of patients in 57 centers in 15 countries. More than 27000 consecutive patients were enrolled. RESULTS: The most important indications were risk stratification in suspected CAD/Ischemia (34.2%), workup of myocarditis/cardiomyopathies (32.2%), as well as assessment of viability (14.6%). Image quality was diagnostic in more than 98% of cases. Severe complications occurred in 0.026%, always associated with stress testing. No patient died during or due to CMR. In 61.8% CMR findings impacted on patient management. Importantly, in nearly 8.7% the final diagnosis based on CMR was different to the diagnosis before CMR, leading to a complete change in management. Interim analysis of suspected CAD and risk stratification in HCM specific protocols revealed a low rate of adverse events for suspected CAD patients with normal stress CMR (1.0% per year), and for HCM patients without LGE (2.7% per year). CONCLUSION: The most important indications in Europe are risk stratification in suspected CAD/Ischemia, work-up of myocarditis and cardiomyopathies, as well as assessment of viability. CMR imaging is a safe procedure, has diagnostic image quality in more than 98% of cases, and its results have strong impact on patient management. Interim analyses of the specific protocols underscore the prognostic value of clinical routine CMR in CAD and HCM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion-weighting in magnetic resonance imaging (MRI) increases the sensitivity to molecular Brownian motion, providing insight in the micro-environment of the underlying tissue types and structures. At the same time, the diffusion weighting renders the scans sensitive to other motion, including bulk patient motion. Typically, several image volumes are needed to extract diffusion information, inducing also inter-volume motion susceptibility. Bulk motion is more likely during long acquisitions, as they appear in diffusion tensor, diffusion spectrum and q-ball imaging. Image registration methods are successfully used to correct for bulk motion in other MRI time series, but their performance in diffusion-weighted MRI is limited since diffusion weighting introduces strong signal and contrast changes between serial image volumes. In this work, we combine the capability of free induction decay (FID) navigators, providing information on object motion, with image registration methodology to prospectively--or optionally retrospectively--correct for motion in diffusion imaging of the human brain. Eight healthy subjects were instructed to perform small-scale voluntary head motion during clinical diffusion tensor imaging acquisitions. The implemented motion detection based on FID navigator signals is processed in real-time and provided an excellent detection performance of voluntary motion patterns even at a sub-millimetre scale (sensitivity≥92%, specificity>98%). Motion detection triggered an additional image volume acquisition with b=0 s/mm2 which was subsequently co-registered to a reference volume. In the prospective correction scenario, the calculated motion-parameters were applied to perform a real-time update of the gradient coordinate system to correct for the head movement. Quantitative analysis revealed that the motion correction implementation is capable to correct head motion in diffusion-weighted MRI to a level comparable to scans without voluntary head motion. The results indicate the potential of this method to improve image quality in diffusion-weighted MRI, a concept that can also be applied when highest diffusion weightings are performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The goal of this study was to characterize the performance of fluorine-19 ((19)F) cardiac magnetic resonance (CMR) for the specific detection of inflammatory cells in a mouse model of myocarditis. Intravenously administered perfluorocarbons are taken up by infiltrating inflammatory cells and can be detected by (19)F-CMR. (19)F-labeled cells should, therefore, generate an exclusive signal at the inflamed regions within the myocardium. METHODS AND RESULTS: Experimental autoimmune myocarditis was induced in BALB/c mice. After intravenous injection of 2×200 µL of a perfluorocarbon on day 19 and 20 (n=9) after immunization, in vivo (19)F-CMR was performed at the peak of myocardial inflammation (day 21). In 5 additional animals, perfluorocarbon combined with FITC (fluorescein isothiocyanate) was administered for postmortem immunofluorescence and flow-cytometry analyses. Control experiments were performed in 9 animals. In vivo (19)F-CMR detected myocardial inflammation in all experimental autoimmune myocarditis-positive animals. Its resolution was sufficient to identify even small inflammatory foci, that is, at the surface of the right ventricle. Postmortem immunohistochemistry and flow cytometry confirmed the presence of perfluorocarbon in macrophages, dendritic cells, and granulocytes, but not in lymphocytes. The myocardial volume of elevated (19)F signal (rs=0.96; P<0.001), the (19)F signal-to-noise ratio (rs=0.92; P<0.001), and the (19)F signal integral (rs=0.96; P<0.001) at day 21 correlated with the histological myocarditis severity score. CONCLUSIONS: In vivo (19)F-CMR was successfully used to visualize the inflammation specifically and robustly in experimental autoimmune myocarditis, and thus allowed for an unprecedented insight into the involvement of inflammatory cells in the disease process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: In the present study, the impact of the two different fat suppression techniques was investigated for free breathing 3D spiral coronary magnetic resonance angiography (MRA). As the coronary arteries are embedded in epicardial fat and are adjacent to myocardial tissue, magnetization preparation such as T(2)-preparation and fat suppression is essential for coronary discrimination. MATERIALS AND METHODS: Fat-signal suppression in three-dimensional (3D) thin- slab coronary MRA based on a spiral k-space data acquisition can either be achieved by signal pre-saturation using a spectrally selective inversion recovery pre-pulse or by spectral-spatial excitation. In the present study, the performance of the two different approaches was studied in healthy subjects. RESULTS: No significant objective or subjective difference was found between the two fat suppression approaches. CONCLUSION: Spectral pre-saturation seems preferred for coronary MRA applications due to the ease of implementation and the shorter cardiac acquisition window.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The susceptibility of blood changes after administration of a paramagnetic contrast agent that shortens T(1). Concomitantly, the resonance frequency of the blood vessels shifts in a geometry-dependent way. This frequency change may be exploited for incremental contrast generation by applying a frequency-selective saturation prepulse prior to the imaging sequence. The dual origin of vascular enhancement depending first on off-resonance and second on T(1) lowering was investigated in vitro, together with the geometry dependence of the signal at 3T. First results obtained in an in vivo rabbit model are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A. Costanza, K. Weber, S. Gandy, C. Bouras, P. R. Hof, P. Giannakopoulos and A. Canuto (2011) Neuropathology and Applied Neurobiology37, 570-584 Contact sport-related chronic traumatic encephalopathy in the elderly: clinical expression and structural substrates Professional boxers and other contact sport athletes are exposed to repetitive brain trauma that may affect motor functions, cognitive performance, emotional regulation and social awareness. The term of chronic traumatic encephalopathy (CTE) was recently introduced to regroup a wide spectrum of symptoms such as cerebellar, pyramidal and extrapyramidal syndromes, impairments in orientation, memory, language, attention, information processing and frontal executive functions, as well as personality changes and behavioural and psychiatric symptoms. Magnetic resonance imaging usually reveals hippocampal and vermis atrophy, a cavum septum pellucidum, signs of diffuse axonal injury, pituitary gland atrophy, dilated perivascular spaces and periventricular white matter disease. Given the partial overlapping of the clinical expression, epidemiology and pathogenesis of CTE and Alzheimer's disease (AD), as well as the close association between traumatic brain injuries (TBIs) and neurofibrillary tangle formation, a mixed pathology promoted by pathogenetic cascades resulting in either CTE or AD has been postulated. Molecular studies suggested that TBIs increase the neurotoxicity of the TAR DNA-binding protein 43 (TDP-43) that is a key pathological marker of ubiquitin-positive forms of frontotemporal dementia (FTLD-TDP) associated or not with motor neurone disease/amyotrophic lateral sclerosis (ALS). Similar patterns of immunoreactivity for TDP-43 in CTE, FTLD-TDP and ALS as well as epidemiological correlations support the presence of common pathogenetic mechanisms. The present review provides a critical update of the evolution of the concept of CTE with reference to its neuropathological definition together with an in-depth discussion of the differential diagnosis between this entity, AD and frontotemporal dementia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In spite of robust knowledge about underlying ischemic myocardial damage, acute coronary syndromes (ACS) with culprit-free angiograms raise diagnostic concerns. The present study aimed to evaluate the additional value of cardiac magnetic resonance (CMR) over commonly available non-CMR standard tests, for the differentiation of myocardial injury in patients with ACS and non-obstructed coronary arteries. MATERIAL/METHODS: Patients with ACS, elevated hs-TnT, and a culprit-free angiogram were prospectively enrolled into the study between January 2009 and July 2013. After initial evaluation with standard tests (ECG, echocardiography, hs-TnT) and provisional exclusion of acute myocardial infarction (AMI) in coronary angiogram, patients were referred for CMR with the suspicion of myocarditis or Takotsubo cardiomyopathy (TTC). According to the result of CMR, patients were reclassified as having myocarditis, AMI, TTC, or non-injured myocardium as assessed by late gadolinium enhancement. RESULTS: Out of 5110 patients admitted with ACS, 75 had normal coronary angiograms and entered the study; 69 of them (92%) were suspected for myocarditis and 6 (8%) for TTC. After CMR, 49 patients were finally diagnosed with myocarditis (65%), 3 with TTC (4%), 7 with AMI (9%), and 16 (21%) with non-injured myocardium. The provisional diagnosis was changed or excluded in 23 patients (31%), with a 9% rate of unrecognized AMI. CONCLUSIONS: The study results suggest that the evaluation of patients with ACS and culprit-free angiogram should be complemented by a CMR examination, if available, because the initial work-up with non-CMR tests leads to a significant proportion of misdiagnosed AMI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé de l'étude La surveillance de la prescription des antibiotiques en milieu hospitalier est une des mesures recommandées pour prévenir l'émergence de bactéries résistantes. La consommation d'antibiotiques est généralement exprimée en termes de DDD (defined daily dose) rapporté au taux d'occupation (jours patients). Cette mesure ne tient cependant pas compte de la variation de la casuistique d'un service au cours du temps. La consommation d'antibiotiques est influencée par l'incidence des infections, qui peut être saisonnière ou varier selon les circonstances épidémiologiques, ainsi que par les habitudes des médecins en termes de prescription. Une échelle de mesure adaptée à ces paramètres est donc capitale pour rendre compte de la consommation d'antibiotiques au sein d'un service et identifier de possibles dérivations dans les habitudes de prescriptions. Nous avons émis l'hypothèse que le nombre de demandes d'hémocultures pouvait servir d'indicateur de la charge infectieuse d'un service. Une analyse préliminaire a permis d'établir une bonne relation entre ce paramètre et l'incidence d'événements infectieux en comparaison à d'autres paramètres testés (nombre de prélèvements microbiologiques provenant de sites stériles ou nombre total de prélèvements microbiologiques). Sur la base de cette hypothèse, nous avons analysé la consommation d'antibiotiques d'une unité de médecine générale (Service de Médecine Interne du CHUV) sur seize trimestres consécutifs en comparant deux échelles de mesures : la méthode standard en DDD par jours patients et une échelle ajustée à la charge infectieuse (DDD par nombre de demandes d'hémocultures). L'échelle ajustée aux hémocultures a permis d'identifier trois trimestres avec une consommation anormalement élevée qui n'avaient pas été classés comme tels par l'échelle standard (consommation dans les normes en DDD par jours patients). Une analyse détaillée d'un de ces trimestres a confirmé une incidence d'infections moins élevée en comparaison à un trimestre de référence (proche de la norme selon les deux échelles), alors que la corrélation entre infections et demandes d'hémocultures était similaire pour les deux périodes. De même, l'échelle ajustée ä la charge infectieuse a démontré une consommation dans la norme pour un trimestre avec une consommation en apparence trop élevée selon l'échelle standard en raison d'une incidence d'infections plus élevée pour cette période. Cette étude a donc permis une identification plus performante et plus précise de périodes avec des dérivations dans la pratique de la prescription des antibiotiques en utilisant une échelle de mesure ajustée à la charge infectieuse d'un service au cours du temps. Nous avons démontré que le nombre d'hémocultures prélevées était un indicateur stable de la charge infectieuse dans un service de médecine générale. Ceci ne permet cependant pas de généraliser l'usage de cet indicateur pour tous les types de service. La pratique des hémocultures peut, en effet, varier d'une unité à l'autre, ou entres différentes institutions. ll convient donc de tester la validité de ce paramètre dans un service avant de l'appliquer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Conventional magnetic resonance imaging (MRI) techniques are highly sensitive to detect multiple sclerosis (MS) plaques, enabling a quantitative assessment of inflammatory activity and lesion load. In quantitative analyses of focal lesions, manual or semi-automated segmentations have been widely used to compute the total number of lesions and the total lesion volume. These techniques, however, are both challenging and time-consuming, being also prone to intra-observer and inter-observer variability.Aim: To develop an automated approach to segment brain tissues and MS lesions from brain MRI images. The goal is to reduce the user interaction and to provide an objective tool that eliminates the inter- and intra-observer variability.Methods: Based on the recent methods developed by Souplet et al. and de Boer et al., we propose a novel pipeline which includes the following steps: bias correction, skull stripping, atlas registration, tissue classification, and lesion segmentation. After the initial pre-processing steps, a MRI scan is automatically segmented into 4 classes: white matter (WM), grey matter (GM), cerebrospinal fluid (CSF) and partial volume. An expectation maximisation method which fits a multivariate Gaussian mixture model to T1-w, T2-w and PD-w images is used for this purpose. Based on the obtained tissue masks and using the estimated GM mean and variance, we apply an intensity threshold to the FLAIR image, which provides the lesion segmentation. With the aim of improving this initial result, spatial information coming from the neighbouring tissue labels is used to refine the final lesion segmentation.Results:The experimental evaluation was performed using real data sets of 1.5T and the corresponding ground truth annotations provided by expert radiologists. The following values were obtained: 64% of true positive (TP) fraction, 80% of false positive (FP) fraction, and an average surface distance of 7.89 mm. The results of our approach were quantitatively compared to our implementations of the works of Souplet et al. and de Boer et al., obtaining higher TP and lower FP values.Conclusion: Promising MS lesion segmentation results have been obtained in terms of TP. However, the high number of FP which is still a well-known problem of all the automated MS lesion segmentation approaches has to be improved in order to use them for the standard clinical practice. Our future work will focus on tackling this issue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this investigation, high-resolution, 1x1x1-mm(3) functional magnetic resonance imaging (fMRI) at 7 T is performed using a multichannel array head coil and a surface coil approach. Scan geometry was optimized for each coil separately to exploit the strengths of both coils. Acquisitions with the surface coil focused on partial brain coverage, while whole-brain coverage fMRI experiments were performed with the array head coil. BOLD sensitivity in the occipital lobe was found to be higher with the surface coil than with the head array, suggesting that restriction of signal detection to the area of interest may be beneficial for localized activation studies. Performing independent component analysis (ICA) decomposition of the fMRI data, we consistently detected BOLD signal changes and resting state networks. In the surface coil data, a small negative BOLD response could be detected in these resting state network areas. Also in the data acquired with the surface coil, two distinct components of the positive BOLD signal were consistently observed. These two components were tentatively assigned to tissue and venous signal changes.