230 resultados para balloon catheter


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The radial artery is routinely used as a graft for surgical arterial myocardial revascularization. The proximal radial artery anastomosis site remains unknown. In this study, we analyzed the short-term results and the operative risk determinants after having used four different common techniques for radial artery implantation. METHODS: From January 2000 to December 2004, 571 patients underwent coronary artery bypass grafting with radial arteries. Data were analyzed for the entire population and for subgroups following the proximal radial artery anastomosis site: 140 T-graft with the mammary artery (group A), 316 free-grafts with the proximal anastomosis to the ascending aorta (group B), 55 mammary arteries in situ elongated with the radial artery (group C) and 60 radial arteries elongated with a piece of mammary artery and anastomosed to the ascending aorta (group D). RESULTS: The mean age was 53.8 +/- 7.7 years; 55.5% of patients had a previous myocardial infarction and 73% presented with a satisfactory left ventricular function. A complete arterial myocardial revascularization was achieved in 532 cases (93.2%) and 90.2% of the procedures were performed under cardiopulmonary bypass and cardioplegic arrest. The operative mortality rate was 0.9%, a postoperative myocardial infarction was diagnosed in 19 patients (3.3%), an intra-aortic balloon pump was used in 10 patients (1.7%) and a mechanical circulatory device was implanted in 2 patients. The radial artery harvesting site remained always free from complications. The proximal radial artery anastomosis site was not a determinant of early hospital mortality. Group C showed a higher risk of postoperative myocardial infarction (p = 0.09), together with female gender (p = 0.003), hypertension (p = 0.059) and a longer cardiopulmonary bypass time. CONCLUSIONS: The radial artery and the mammary artery can guarantee multiple arterial revascularization also for patients with contraindications to double mammary artery use. The four most common techniques for proximal radial artery anastomosis are not related to a higher operative risk and they can be used alternatively to reach the best surgical results

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Our objective was to compare two state-of-the-art coronary MRI (CMRI) sequences with regard to image quality and diagnostic accuracy for the detection of coronary artery disease (CAD). SUBJECTS AND METHODS: Twenty patients with known CAD were examined with a navigator-gated and corrected free-breathing 3D segmented gradient-echo (turbo field-echo) CMRI sequence and a steady-state free precession sequence (balanced turbo field-echo). CMRI was performed in a transverse plane for the left coronary artery and a double-oblique plane for the right coronary artery system. Subjective image quality (1- to 4-point scale, with 1 indicating excellent quality) and objective image quality parameters were independently determined for both sequences. Sensitivity, specificity, and accuracy for the detection of significant (> or = 50% diameter) coronary artery stenoses were determined as defined in invasive catheter X-ray coronary angiography. RESULTS: Subjective image quality was superior for the balanced turbo field-echo approach (1.8 +/- 0.9 vs 2.3 +/- 1.0 for turbo field-echo; p < 0.001). Vessel sharpness, signal-to-noise ratio, and contrast-to-noise ratio were all superior for the balanced turbo field-echo approach (p < 0.01 for signal-to-noise ratio and contrast-to-noise ratio). Of the 103 segments, 18% of turbo field-echo segments and 9% of balanced turbo field-echo segments had to be excluded from disease evaluation because of insufficient image quality. Sensitivity, specificity, and accuracy for the detection of significant coronary artery stenoses in the evaluated segments were 92%, 67%, 85%, respectively, for turbo field-echo and 82%, 82%, 81%, respectively, for balanced turbo field-echo. CONCLUSION: Balanced turbo field-echo offers improved image quality with significantly fewer nondiagnostic segments when compared with turbo field-echo. For the detection of CAD, both sequences showed comparable accuracy for the visualized segments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our objective was to evaluate efficacy and patency of metallic stent placement for symptomatic Budd-Chiari syndrome (BCS) due to prothrombotic disorders. Eleven patients with proved BCS due to prothrombotic disorders were referred for endovascular treatment because of refractory ascites (n=9), abdominal pain (n=8), jaundice (n=6), and/or gastrointestinal bleeding (n=4). Stents were inserted for stenosed hepatic vein (n=7), inferior vena cava (n=2), or mesenterico-caval shunt (n=2). Clinical efficacy and stent patency was evaluated by clinical and Doppler follow-up. After a mean follow-up of 21 months, 6 patients had fully patent stents without reintervention (primary stent patency: 55%). Two patients with hepatic vein stenosis had stent thrombosis and died 4 months after procedure. Restenosis occurred in 3 cases (2 hepatic vein and 1 mesenterico-caval shunt stenosis) and were successfully treated by balloon angioplasty (n=2) and addition of new stents (n=1) leading to a 82% secondary stent patency. Of 9 patients with patent stent, 7 were asymptomatic (77%) at the end of the study. Stent placement is a safe and effective procedure to control of symptomatic BCS. Prothrombotic disorder does not seem to jeopardize patency in anticoagulated patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Surgical ablation procedures for treating atrial fibrillation have been shown to be highly successful. However, the ideal ablation pattern still remains to be determined. This article reports on a systematic study of the effectiveness of the performance of different ablation line patterns. METHODS AND RESULTS: This study of ablation line patterns was performed in a biophysical model of human atria by combining basic lines: (i) in the right atrium: isthmus line, line between vena cavae and appendage line and (ii) in the left atrium: several versions of pulmonary vein isolation, connection of pulmonary veins, isthmus line, and appendage line. Success rates and the presence of residual atrial flutter were documented. Basic patterns yielded conversion rates of only 10-25 and 10-55% in the right and the left atria, respectively. The best result for pulmonary vein isolation was obtained when a single closed line encompassed all veins (55%). Combination of lines in the right/left atrium only led to a success rate of 65/80%. Higher rates, up to 90-100%, could be obtained if right and left lines were combined. The inclusion of a left isthmus line was found to be essential for avoiding uncommon left atrial flutter. CONCLUSION: Some patterns studied achieved a high conversion rate, although using a smaller number of lines than those of the Maze III procedure. The biophysical atrial model is shown to be effective in the search for promising alternative ablation strategies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Gadolinium-enhanced pulmonary magnetic resonance angiography (MRA) can be an option in patients with a history of previous adverse reaction to iodinated contrast material and renal insufficiency. Radiation is also avoided. The aim of this study is to prospectively compare the diagnostic value of MRA with that of a diagnostic strategy, taking into account catheter angiography, computed tomography angiography (CTA), and lung scintigraphy [ventilation-perfusion (VQ)]. MATERIAL AND METHODS: Magnetic resonance angiography was done in 48 patients with clinically suspected pulmonary embolism (PE) using fast gradient echo coronal acquisition with gadolinium. Interpretation was done with native coronal images and multiplanar maximum intensity projection reconstructions. Results were compared to catheter angiography (n=15), CTA (n=34), VQ (n=45), as well as 6-12 months clinical follow-ups, according to a sequenced reference tree. RESULTS: The final diagnosis of PE was retained in 11 patients (23%). There were two false negatives and no false positive results with MRA. Computed tomography angiography resulted in no false negatives or false positives. Magnetic resonance angiography had a sensitivity of 82% and a specificity of 100%. CONCLUSION: In our study, pulmonary MRA had a sensitivity of 82% and a specificity of 100% for the diagnosis of PE, with slightly less sensitivity than CTA. In the diagnostic algorithm of PE, pulmonary MRA should be considered as an alternative to CTA when iodine contrast injection or radiation is a significant matter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Key factors of Fast Track (FT) programs are fluid restriction and epidural analgesia (EDA). We aimed to challenge the preconception that the combination of fluid restriction and EDA might induce hypotension and renal dysfunction. METHODS: A recent randomized trial (NCT00556790) showed reduced complications after colectomy in FT patients compared with standard care (SC). Patients with an effective EDA were compared with regard to hemodynamics and renal function. RESULTS: 61/76 FT patients and 59/75 patients in the SC group had an effective EDA. Both groups were comparable regarding demographics and surgery-related characteristics. FT patients received significantly less i.v. fluids intraoperatively (1900 mL [range 1100-4100] versus 2900 mL [1600-5900], P < 0.0001) and postoperatively (700 mL [400-1500] versus 2300 mL [1800-3800], P < 0.0001). Intraoperatively, 30 FT compared with 19 SC patients needed colloids or vasopressors, but this was statistically not significant (P = 0.066). Postoperative requirements were low in both groups (3 versus 5 patients; P = 0.487). Pre- and postoperative values for creatinine, hematocrit, sodium, and potassium were similar, and no patient developed renal dysfunction in either group. Only one of 82 patients having an EDA without a bladder catheter had urinary retention. Overall, FT patients had fewer postoperative complications (6 versus 20 patients; P = 0.002) and a shorter median hospital stay (5 [2-30] versus 9 d [6-30]; P< 0.0001) compared with the SC group. CONCLUSIONS: Fluid restriction and EDA in FT programs are not associated with clinically relevant hemodynamic instability or renal dysfunction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Acute limb ischemia after thrombosis of a popliteal aneurysm is a distinct and limb-threatening entity. Preoperative intra-arterial thrombolysis may improve the outcome in this challenging situation. This study retrospectively analyzed a consecutive series of patients treated with preoperative thrombolysis and subsequent revascularization. METHODS: Thirteen patients with acute limb ischemia caused by thrombosis of a popliteal aneurysm underwent catheter-directed intra-arterial thrombolysis with urokinase and subsequent vascular reconstruction. The angiographic and clinical outcome was analyzed and compared with that in the literature. RESULTS: Complete aneurysm thrombosis with absence of runoff was documented in 12 cases. Thrombolysis restored perfusion with patency of the popliteal artery and a one- or two-vessel runoff in 77% of cases (10/13). Early cumulative graft patency and limb salvage rates were 68% and 83%, respectively, with an ankle/brachial index of 0.8 +/- 0.2. Lytic failure followed by attempts at bypass grafting was present in three patients (23%) and resulted in above-knee amputation. Severe rhabdomyolysis and fatal pulmonary embolism were responsible for a 15% early mortality rate. CONCLUSION: Preoperative thrombolysis followed by bypass grafting is a valid treatment option for patients who can withstand an additional period of ischemia that does not require immediate revascularization and intraoperative lysis. Lytic failure identifies patients with a highly compromised runoff who are probably best treated by means of subsequent amputation, without any attempts at bypass grafting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: A hybrid intervention is a joint procedure involving the interventional cardiologist and the cardiac surgeon. At our institution we have opted for this type of approach in congenital heart disease since 2005. We report here our initial experience. Cases: 1. A 3 year old boy with double aortic arch and multiple muscular ventricular septal defects (VSD),was readdressed for pulmonary band (PAB) removal and residual VSD closure after previous palliation. After surgical removal of the PAB, the surgeon provided a minimal transventricular access for placement of a 6mm Amplatzer® muscular VSD occluder by the cardiologist under transoesophageal guidance. The patient was extubated the same day and discharged after 5 days. 2. An 8 year old girl with Williams syndrome was followed for two large VSDs and severe peripheral pulmonary arteries (PA) stenosis. The membranous VSD was closed surgically, the muscular VSD during the same operation by direct placement of a 12 mm Amplatzer® muscular VSD occluder. During rewarming, balloon angioplasty of peripheral PA stenosis was achieved under fluoroscopy. Patient was extubated the following day and discharged after 8 days. 3. A 9 year old boy post tetralogy of Fallot repair had severe distal stenosis of the right ventricular to PA conduit.With patient on partial cardiopulmonary bypass, an incision was made on the conduit and a CP 8 Zig 16 stent placed on the stenosis. The child passed on full bypass and the definitive placement of the stent achieved. The child was extubated at the end of the intervention and discharged after 6 days. 4. A newborn presented at 2 days life with complex aortic arch anatomy: left aortic arch and right descending thoracic aorta perfused directly from a right arterial duct and left PA atresia. The arterial duct was stented with a Genesis XD stent dilated at 7mm. Two days later the cardiac surgeon made banded the right PA. The child was extubated after the operation and discharged a week later. Conclusion: Hybrid approach opens new ways of correction or palliation in congenital heart disease with encouraging results and less morbidity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND AIM OF THE STUDY: Transapical transcatheter aortic valve replacement (TAVR) is a new minimally invasive technique with a known risk of unexpected intra-procedural complications. Nevertheless, the clinical results are good and the limited amount of procedural adverse events confirms the usefulness of a synergistic surgical/anesthesiological management in case of unexpected emergencies. METHODS: A review was made of the authors' four-year database and other available literature to identify major and minor intra-procedural complications occurring during transapical TAVR procedures. All implants were performed under general anesthesia with a balloon-expandable Edwards Sapien stent-valve, and followed international guidelines on indications and techniques. RESULTS: Procedural success rates ranged between 94% and 100%. Life-threatening apical bleeding occurred very rarely (0-5%), and its incidence decreased after the first series of implants. Stent-valve embolization was also rare, with a global incidence ranging from 0-2%, with evidence of improvement after the learning curve. Rates of valve malpositioning ranged from 0% to < 3%, whereas the risk of coronary obstruction ranged from 0% to 3.5%. Aortic root rupture and dissection were dramatic events reported in 0-2% of transapical cases. Stent-valve malfunction was rarely reported (1-2%), whereas the valve-in-valve bailout procedure for malpositioning, malfunctioning or severe paravalvular leak was reported in about 1.0-3.5% of cases. Sudden hemodynamic management and bailout procedures such as valve-in-valve rescue or cannulation for cardiopulmonary bypass were more effective when planned during the preoperative phase. CONCLUSION: Despite attempts to avoid pitfalls, complications during transapical aortic valve procedures still occur. Preoperative strategic planning, including hemodynamic status management, alternative cannulation sites and bailout procedures, are highly recommended, particularly during the learning curve of this technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Infection of an intervertebral disk is a serious condition. Diagnosis often is elusive and difficult. It is imperative to obtain appropriate microbiological specimens before initiation of treatment. The authors describe a 51-year-old woman with lumbar spondylodiscitis that was because of infection after the placement of an epidural catheter for postoperative analgesia. A spinal magnetic resonance imaging confirmed the diagnosis, but computed tomography-guided fine needle biopsy did not provide adequate material for a microbiologic diagnosis. Laparoscopic biopsies of the involved disk provided good specimens and a diagnosis of Propionibacterium acnes infection. The authors believe that this minimally invasive procedure should be performed when computed tomography-guided fine needle biopsy does not provide a microbiologic diagnosis in spondylodiscitis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Barrett's esophagus consists of the replacement of normal squamous epithelium by a specialised columnar lined epithelium referred to as intestinal metaplasia in the esophagus. It represents a premalignant lesion. The prevalence of Barrett's esophagus is around 1.6%. Esophageal adenocarcinoma results from the development of dysplasia progressing from low to high grade dysplasia and finally adenocarcinoma. Radiofrequency ablation currently represents the treatment of choice in eradicating Barrett's esophagus with associated dysplasia. The technique is based on the application of a radiofrequency current that enables the destruction of the superficial modified epithelium. This new approach presents a good security profile and, compared to other ablative techniques, shows superior results regarding Barrett's eradication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

pH monitoring has been used as a diagnostic tool in gastro-oesophageal reflux disease (GERD) for many years. Recent studies have shown that wireless capsule pH monitoring is better tolerated and interferes less with daily activities as compared to traditional catheter-based pH monitoring. Moreover, prolonged recording time (48 h instead of 24 h) is possible with wireless pH monitoring. The main secondary effect of wireless capsule pH monitoring is induction of thoracic discomfort in 10-65% of the patients, which can vary from mild foreign body sensation to severe chest pain. Sensitivity and specificity of wireless capsule monitoring is comparable to that of traditional pH monitoring. It has not been proven yet that better tolerability and a longer recording time increases the diagnostic yield of wireless capsule monitoring in GERD.

Relevância:

10.00% 10.00%

Publicador: